Loading…
Loading…
Tender Value
₹89.7 L
EMD Value
₹1.6 L
Closing Date
8 Oct 2026, 6:00 pm
Sh Rakesh Jha, IDSE, SE, CWE
HQ CWE Bikaner Bikaner Military Station
Special repair to Toilets and Bathroom (T-46 and T-47 of Adm Camp), Toilets block (T-40 of Cul-2) and Bathrooms (T-114 to T-121 of Cul -3) and Offr living Brk (T-32 of Adm Camp) of East Camp, MFFR under AGE (I) MFFR
2026_MES_788766_1
CA No CWE BKN-Token No 43/2026-2027
Open Tender
Civil Works
Item Rate
270 days
MFFR
Please refer tender documents
7 documents required · 7 mandatory
₹1,000
AGE (I) MFFR
₹1.6 L
Yes
10 Sept 2026
10 Sept 2026
15 Oct 2026
10 Sept 2026
8 Oct 2026
1 Oct 2026
10 Sept 2026 - 24 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Dismantling of Wall and ceiling boards or insulation boards with Frame Of Mild Steel , any thickness,any description, including cover fillets complete all as specified and as directed. | 480 | Sqm | 100 | ₹48,000 |
| 2 | S &F Gl frame work for seamless ceiling comprising of Glperimeter channnel 0.55 mm thick with two unequal flangesof 20 and 30 mm and web of27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre tocentre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended fromsoffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediatechannel with connecting clips across the intermediate channel at 457 mm centre to centre complete all as specified and as directed. | 480 | Sqm | 101 | ₹48,480 |
| 3 | S&F 4mm thick HPSC ( High pressure steam cured preprimed textured designer board, water resistant, be placed in the grid system complete all as specified and as directed. | 480 | Sqm | 104 | ₹49,920 |
| 4 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames) of size exc 1.5 Sqm but not exc 4.0 Sqm each complete all as specified and as directed by Engineer-in-Charge. | 25 | Each | 108 | ₹2,700 |
| 5 | Taking down shutters of any description, area exc 1.00 sqm and n.exc 2.00 sqm each complete all as specified and as directed by Engineer-in-Charge. | 45 | Per Leaf | 104 | ₹4,680 |
| 6 | Taking down old rusted and demaged steel window/vent incl. guard bar and grill where exist of size not exc 1.5 sqm each complete all as specified and as directed by Engineer-in-Charge. | 70 | Each | 108 | ₹7,560 |
| 7 | Supply and fixing factory made uPVC white colour Three track three panels sliding shutter with fly proof S.S. wire mesh (Two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 82 mm both having wall thickness of 2.3 + 0.2 mm and single glazing bead/ double glazing bead of appropriate dimension. (Area of door above 2.00 sqm upto 5.00 sqm) comprising of uPVC chambered frame, with in-built roller track and sash extruded profiles duly reinforced with 1.60 + 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension uPVC extruded glazing beads, uPVC extruded interlock and uPVC extruded Inline sash adaptor (if required), EPDM gasket, wool pile, zinc alloy (white powder coated) handle with key on one side of extreme panels along with zinc plated mild steel multi point locking having transmission gear with keeps, zinc alloy (white powder coated) cresent lock (if required).stainless steel (SS 304 grade) body with adjustabledouble nylon rollers (weight bearing capacity to be 120 kg), G.I fastener 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, complete all as specified and as directed by Engineer-in-Charge. (Glass or wiremesh shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. | 5.4 | Sqm | 108 | ₹583.2 |
| 8 | M&L for Anodised aluminium powder coated window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and as directed by Engineer-in-Charge. | 26 | Sqm | 108 | ₹2,808 |
| 9 | M&L for Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed by Engineer-in-Charge. | 150 | Kg | 108 | ₹16,200 |
| 10 | Hacking out old broken glass (any thickness, size, quality or description) from wooden/steel frames or stone or concrete or bricks surrounds glazesd with putty complete all as specified and as directed by Engineer-in-Charge. | 15 | Sqm | 108 | ₹1,620 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.27 MB
Tender43.pdf
Tender Documents • 1.60 MB
BOQ_884141.xls
BOQ • 0.46 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .