Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.5 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹40.7 L+₹1.9 L (5.03%)Rejected-AOC OPP CCS GARACHARMA PORT BLAIR 744105 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744105 | L2 | Rejected-AOC Not L1 | |
| 3 | L3₹42.9 L+₹4.1 L (10.6%)Rejected-AOC | L3 | Rejected-AOC Not L1 | |
| 4 | L4₹43.3 L+₹4.6 L (11.8%)Rejected-AOC ATR MAIN ROAD GARACHARMA II OPP MAHINDRA JADWET SHOWROOM SRI VIJAYA PURAM 744105 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744105 | L4 | Rejected-AOC Not L1 | |
| 5 | L5₹44.5 L+₹5.7 L (14.7%)Rejected-AOC | L5 | Rejected-AOC Not L1 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
30 Aug 2021, 6:00 pmClosed
GE Brichgunj
GE Brichgunj Port Blair
PROVN OF REAR GATE ALONG WITH SENTRY POST AND URINAL POINT AT WKSP KLP OF 262 FD WORK SHOP SPECIAL REPAIRS TO BLDG NO P-59/A2, ADDN ALTN TO ROOM NEAR BDE CONFRANCE HALL AT BRICHGUNJ MIL STATION PORT BLAIR
2021_MES_466130_1
GE8146A
Open Tender
Civil Works
Item Rate
180 days
Brichgunj
as per tender documents
8 documents required · 8 mandatory
₹500
GE Brichgunj
₹80,000
Yes
8 Oct 2021
7 Aug 2021
1 Sept 2021
7 Aug 2021
30 Aug 2021
23 Aug 2021
7 Aug 2021 - 21 Aug 2021
Amount
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft / loose soil all as specified and directed
Excavation in trenches n. exc. 1.5 m wide and not exceeding 1.5 m in depth, for foundation, etc or for shafts, walls, cesspits, manholes, pier holes, etc getting out in any type of soil, complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft to loose soil.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point
Material and labour Hard Core of gauge n.exc. 63mm deposited spread and levelled in layers n.exc. 15 cm thick watered and rolled/ rammed to a true surfce.
Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specified complete all as directed.
Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing the rubbish off the premises.
Taking down cement plaster on Brick / Concrete surfaces incl raking out joints, hacking for key scrubbing down with water and Removing Rubbish outside of the MD Land all as directed by Engineer-in-Charge.
Taking down chowkats or frames not exceeding 1.5 SqM with shutters (Without taking off shutters & Grill from the frame).
Taking down chowkats or frames exceeding exc 1.5 sq. m but n exc 4 sq. m each (Without taking off shutters & Grill from the frame).
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition)
Material and labour 25mm thick PCC 1:2:4 Type B-0 using 12.5 mm graded stone aggregate as in flooring finished fair and even without using extra cement complete all as specified and directed.
Material and labour for providing 100mm thick cement concrete 1:4:8 Type D2 using 40mm graded stonne aggregate as in sub base of flooring complete all as specified and directed.
Material and labour for PCC 1:3:6 Type C1 using 20mm graded aggregate of 75mm thick as in Plinth Protection, surface finished even and smooth without using Extra cement, laid in panels n.exc 3 mtr long and joints shall be filled with the mixture of bitumen and sand in (1:3) by weight complete all nas specified and directed
Material and labour for PCC 1:2:4 Type B2, using 40mm graded stone aggregate of 100mm thick as in hard standing and footpath complete all as specified and directed.
Material and labour for Damp proof course PCC 1:2:4 Type B0,(using 12.50mm graded stone aggregate) 40 mm thick to horizontal surfaces including necessary formwork complete all as specified and directed.
Material and labour Precast Cement Concrete Block Masonry with Solid Block, exc 10cm in width in Type C-1, 1:3:6 (using 20mm graded stone aggregate) set in CM (1:6) complete all as specified and directed.
Material and labour for Plain cement concrete 1:4:8 Type D2 using 40mm graded stone aggregate as in foundation filling complete all as specified and directed.
Material and labour for precast man holes cover slab with 1:2:4 Type B1 using 20mm graded stone aggregate set in CM 1:4 incl cost of use and waste of clean sawn wooden form work but excl cost of reinforcement all as specified
Material and labour PCC 1:2:4 Type B1 using 20mm graded stone aggregate as in surface channel / benching incl cost of use and waste of clean sawn wooden form work complete all as specified and directed.
Extra for forming fair finished drain or channel 30CM inner girth in cement concrete, using extra cement, including forms, moulds, mited/stopped ends etc
Material and Labour for PCC 1:3:6 Type C1 using 20mm graded stone aggregate as in coping including necessary formwork complete all as specified and as directed.
Material and labour RCC- M-30 (Design Mix) using 20mm graded aggregate For Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete as Mass Concrete complete all as specified and as directed.
Material and labour RCC- M-30 (Design Mix) using 20mm graded aggregate for Facias complete all as specified and as directed.
Material and Labour for Reinforced cement concrete M-30 (Design mix) using 20mm graded stone aggregates as Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like and like that complete all as specified and as directed.
Material and labour for RCC- M -30 Design Mix as in columns, pillars, piers,posts and struts complete all as specified and directed.
Material and labour RCC- M-30 (Design Mix) using 20mm graded aggregate for GF Lintel Beam and lintel, roof Beam complete all as specified and as directed.
Use & Waste formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and as directed.
Use and waste of form work to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and as directed.
use & waste Form work for rough finished surfaces of concrete measured flat for GF Lintel Beam and lintel, roof Beam complete all as specified and directed.
use and waste Form work for rough finished surfaces of concrete measured flat for Facias complete all as specified and directed.
use and waste formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) flat surfaces complete all as specified and as directed.
Material and Labour for TMT bars 10mm dia and over dia cut to length, bent to shape required, including cranking, bending, hooking ends and binding with MS wire (annealed) not less than 9mm dia or securing with clips complete all as specified and as directed.
All as per item No 33 but 5mm dia and over up to and including 10mm dia as in stirrups, spacers, binders and the like
Material and labour Rendering 10mm thick on internal sides wall of Brick / Concrete Surfaces in CM (1:6) finished even & smooth without using extra cement.
Material and labour Rendering 15mm thick in two coat ie. 10mm thick under coat in CM 1:4 and 5mm thick finishing coat in CM 1:4 finished even & smooth without using extra cement and using WPC of both coth as vper Manufacturer Instruction
Material and labour Rendering 10mm thick on concrete surfaces such as sofit of slab, chajja etc in CM (1:3) finished even & smooth without using extra cement,.
Supply only water proofing Compound
Material and labour Preparation of newly plastered surface and applying three coat of whitewash on Ceiling all as specified and directed.
Preparation of newly plastered surface and two coats of oil bound distemper over a coat of primer over one coat of Birla White Care Putty on walls all as specified and directed.
Material and labour Preparation of Newly plastered surfaces of Wall and applying two coats of Cement Base paint over a coat of putty all as specified and directed.
Material and labour for preparing new steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces.
Material and labour for oil bound distempering two coats over a coat of alkali resistant priming paint including preparation of new plastered or unplastered surfaces of wall complete all as specified and directed by Engineer - in -Charge.
All as per item No 43 above but on ceiling
Material and labour for Complete removal of existing treatment and preparing old surfaces for applying two coat of oil bound distemper on one coat of primer over a coat of putty on walls all as specified and directed.
All as per item No 45 above but on ceiling
Preparation of old external surfaces of walls, Facias, cornices etc and applying one coat of weather proof anti-fungal paint (Apex - ultima) over a coat of external wall care putty all as per manufacturer instruction and as directed by Engineer-in-Charge.
Material and labour for two coat of weather proof exterior acrylic emulsion paint with anti-fungal property over a coat of primer and a coat of external wall care putty on newly plastered wall surfaces including preparation of surfaces etc complete all as specified and as directed by Engineer-in-Charge.(Make Apex Ultima)
Material and labour for applying one coat epoxy bonding agent @ 2.6 sqm/lit or as per manufactures instruction to old concrete surfaces of columns, beams and similar structural members complete all as specified and as per directed by Engineer-in-Charge. Make Nitobond EP of Fosroc or equivalent
Material and labour for spraying curing compound as per manufactures instruction on freshly cast concrete surfaces all as specified. Make: Concure WB white of Fosroc.
Supply and fix Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment etc and fixed by riveting or welding or with nut and bolts (including nuts and bolts) conforming to Fe-410-W grade E250 Quality B complete all as specified and directed.
Supply and fix Mild steel Bolts Exceeding 12mm n. exceeding 20mm dia, purpose made with Hexagonal or Square head one end and screwed the other, or Screw both ends, each screwed end to be fitted with Washers and one hexagonal or Square nut, Exceeding 30 cm long all as specified and directed.
Supply and fix Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc as in Fe-410-W(Gde-E-250)quality-B all as specified and directed by engineer in charge.
Supply and fix Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete of Fe-410-W (grade E-250) Quality B
Supply and fix Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; handmade sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165
Supply and fix MS Steel work in tubular trusses and tubular posts/ purlins including special shaped washers etc., complete using ERW or induction butt welded tubes conforming to IS :1161-1979 grade st-240 including notching, drilling, fitting, riveting and/or welding or connecting with bed plate, bolt and nuts complete all as specified and as directed
Material and labour for false ceiling with aluminium grid work (Size of grid 600x600 mm) with 35 x 25 x 1.5 mm main tee and 25 x 25 x 1.4 mm cross tee and wall angle and suspended with 2mm dia GI wire hooked to roof with needful adjustment bolts at an interval of 1.20 m centre to centre staggered and board with Eco board decorative type size 600 x 600 x 4 mm thick finished with two coats of oil bound distemper over a coat of primer on exposed surfaces all as specified and directed by Engineer-in-Charge.
Supply and fix 0.50 mm thick pre painted galvalume aluminium zinc coating GI based corrugated steel sheet of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self taping screws as specified.
Supply and fix 0.50 mm thick pre painted galvalume aluminium zinc coating GI based plain steel sheet of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self taping screws as specified.
Material and labour for Dark coloured vitrified tiles 8 to 10 mm thick (square/rectangular) polished, area of each tiles n exc. 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed with coloured or white cement to match including screed bed 15mm thick 1:4, complete all as specified and as directed by Engineer-in-Charge.
All as per item No 60 here in before, but on vertical surfaces including 10mm thick CM 1:3 as in backing coat of dado/Skirting
Material and labour Coloured Non-Skid Ceramic tiles 7 to 8mm thick (square/rectangular) area of each tiles exceeding 0.06 Sqm but not exceeding 0.11 Sqm in floor etc,set and jointed in neat cement sluryy and pointed in coloured cement to match as in floor over 20mm thick screed bed in CM (1:6).
Material and labour Glazed Ceramic Coloured tiles 300 x200x 7mm thick as in Dado/Skirting/Steps etc set and jointed in neat cement slurry and pointed in coloured cement to match over and including backing coat of 10mm thick CM (1:3) all as specified and directed.
Material and labour non-skid ceramic tiles 7 to10mm thick (Square/rectangular) area of each tile exceeding 0.18 Sqm and not exceeding 0.38 Sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the coloured tiles over 15mm thick screed bed in CM 1:4
All as per item No 64 here in before, but on vertical surfaces incl 10mm thick CM 1:3 as in baking coat of dado/skirting
Material and labour for coloured glazed ceramic tiles, (450 x 300mm) x 7mm thick on vertical surfaces set and jointed in neat cement slurry and pointed in white or colour cement to match the colour of tile over and including rendering 10mm thick in CM 1:3 complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and including 20 mm Thick Screed bed or bedding layer of mortar CM(1:4) complete
Material and labour Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with coloured / White Cement in match as in Skirting portion of wall surfaces over 10mm thick backing coat of CM 1:6
Material and labour for 20mm thick Granite of any type work table rubbed and polished in steps, jambs , pillars, cooking platforms and the like including pointing with white cement 1:2 using marble dust with admixture of pigment to match with shade of granite including Screed bed of coat 20mm thick CM (1:4) complete
Material and labour for 20 mm thick granite (of any type) work (table rubbed and polished) for wall lining (veneering to wall) 12 mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed.
Material and labour Chequered cement concrete tiles, with grey cement and pigment 30cm x30cm x20mm thick set, jointed and pointed in neat cement slurry in floors including 15mm thick screed bed in Cm 1:4 all as specified and directed.
Material and labour for 60mm thick coloured machine pressed precast concrete interlocking paver block glossy finished any size and shape conforming to IS 15658-2006 , M-35 Grade with grey cement and pigment over sand filling complete all as directed. (Rate including cost of sand filling)
Material and Labour for apply water proofing treatment with the following specifications complete all as specified and as per manufacturer’s instructions:- (i) Rendering 10mm thick in CM 1:4 on concrete surfaces mixed with water proofing compound @ 3% by weight of cement as leveling course (ii) Apply a coat of hot blown bitumen 85/25 @ 1.20 kg/sqm over a coat of bituminous primer @ 0.3 ltr per sqm. (iii) Laying APP membrane (STP Aquashield or equivalent) weighing not less than 3.5Kg/sqm, reinforced with polyster non woven fabric (weighing not less than 150 gms/sqm) with 100mm over laps both longitudinally and transversally and overlaps shall be sealed by torch, membrane shall be taken to the parapet through fillet and shall be tucked in inside after a height of 300 mm. (iv) Apply one coat of hot blown bitumen 85/25 @ 1.2 kg/sqm over the membrane. Note:- Water proofing compound shall be measured and paid separately)
Supply and fix Aluminium anodised (minimum anodisation is 15 microns) Door / window / Ventilator/partition frames and shutters (02 Nos glazed & gauzed), side hung type, without sash bars, standard aluminium grills, necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, handles, locking arrangements etc., complete with standard aluminium sections, complete all as specified and as directed by Engineer-in-charge.(Aluminium section shall be of make Jindal/Hindalco/ Indalco). (Note:- Weight of various Aluminium sections handles and locking arrangements shall only be considered for measurement for payment. However cost of rubber packing given in the item shall be deemed to be included in the rate quoted. Glass panels, prelaminated particle boards, aluminium wire cloth as applicable will be measured and paid separately as supplied only).
Supply and fix Solid PVC door frame of size 50mmx47mm made out of 5mm wooden grain printed PVC sheet, edges will be painted to match with printed sheet, reinforced with MS square tube & fixing in opening.
Supply and fix Factory made solid panel PVC door shutter 30mm thick (stiles) consisting of frame made out of MS Tubes for top & bottom rails, MS frame shall be covered with heat moulded wooden grain printed PVC sheet and 5mm thick x 15mm wide PVC sheet beading used inside stiles & rails and decorative PVC beading of 10mmx10mm used instead of exposed portion of PVC sheet beading.
Supply only 4 mm thick sheet figured glass and glazing with rubber packing around the glass, in squares exceeding 0.50 sqm in each pane complete all as specified and as directed.
Supply only Aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples complete all as specified and as directed by Engineer-in-Charge.
Supply and fix 100 Butt hinges extruded aluminium alloy, anodised with galvanished mild steel hinge pin , anodised and fixed type B-21
Supply and fix 200mm Aluminium anodised barrel tower bolts of extruded sections.
Supply and fix 150mm Extruded aluminium alloy handles, fabricated type, anodised.
Supply and fix in repair aluminium composite panel sheet of 3mm to 4mm thick, fixed on existing aluminium frame work with plastic strips (double sided sticker) of suitable size of varying thickness of 10mm to 30mm including aluminium frame work, applying adhesive over aluminium sections for fixing composite panel and fixed with screws. The joints of panels shall be filled with weather proof sealant. The board shall be stuck with a layer of any colour high intensity reflective grade polymer sticker installed using epoxy adhesive, complete all as specified and as directed.
Supply and fix 15mm Bore Stop Valves / Angle Cock Fancy Type Chromium plated cast copper alloy screwed down high pressure with crutch or butterfly handles screwed both ends.
Supply and fix in Repair looking mirror Bevelled Edge 600mmx450mm mounted on 6mm thick AC building board or commercial ply wood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed by the Engineer -in- charge..
Supply and fix 2 Way Bib Cock Double handle with flange 15 mm bore cast copper alloy Chromium plated with wall flange, screwed down, screwed for pipes. (Make:- Prayag Cat No -8312 or Equivalent)
Supply and fix Gun Metal Gate valves 20 mm dia with iron wheel head screwed both ends for iron pipes complete all as specified and as directed.
Supply and fix Chromium Plated Steel Grating of 100mm size complete all as specified and as directed.
Supply and fix Vitreous China Wash hand basin, white flat back size 550x400 mm including brackets(including Pillar Tap 15 mm bore Chromium plated cast copper alloy with capstan heads, 32 mm waste coupling brass chromium plated suitable for wash hand basins, with long screwed shanks and fly nuts & PVC waste pipe) all as specified & directed by Engineer-in-charge.
Supply and fix PVC flexible connections 15 mm dia 450 mm long with brass check nuts.
Supply and fix 100 mm CI Floor trap with grating incl jointing to waste pipe fixed in cement concrete type B1 (1:2:4).
Supply and fix in repairs Aluminium anodised chromium plated tubular towel rail, 20mm dia, D type, 60cm long, between flanges including suitable bracket complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repairs stainless steel gratings 125mm dia, complete all as specified and as directed
Supply and fix in repairs Bib tap long body cast copper alloy chromium plated 15mm dia with fancy type screwed down screwed for iron pipe or brass ferule etc complete all as specified and as directed by Engineer-in-Charge
Supply and fix in repairs sink with drainage board made up of stainless steel 1mm thick for kitchen or laboratory with plug washers and waste fittings including bedding in CM 1:3 into dwarf wall or cantilever brackets and connecting union to pipe overall size 915mm x 460mm, bowl size 410 x 330 x 160mm etc complete all as specified and as directed by Engineer-in-Charge
Supply and fix 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to walls heights up to3.5M or laid in floor.
Taking up or down, 20mm dia bore, GI tubing, medium grade, including cleaning for refixing or removing from site, complete all as specified and as directed by Engineer-in-Charge.
Taking up or down, 15mm dia bore, GI tubing, medium grade, including cleaning for refixing or removing from site, complete all as specified and as directed by Engineer-in-Charge.
Supply and fix UPVC 25mm bore pipes of pressure rating 10 Kgf/Sqcm fixed with all fittings and fixed to walls and ceillings or laid in floors etc complete all as specified and as directed.
Supply and fix UPVC 20mm bore pipes of pressure rating 10 Kgf/Sqcm fixed with all fittings and fixed to walls and ceilings or laid in floors etc complete all as specified and as directed.
Supply and fix of CPVC pipes Outer diameter in 20 mm, SDR 11 & Plain CPVC SDR 11 fittings fixed to walls and ceilings or laid in floors complete all as specified.
All as per item No 100 above but Outer diameter of pipe in 25 mm
Cutting chases, pinning in, making good to facings for concealed water tubing and pointing in CM 1:3, cutting not exc 10 cm girth.
Material and labour for cutting existing 50mm GI line and making branch connection of 25 mm dia GI line complete all as specified and directed
Supply and fix in repairs Rotational mould polyethylene water storage tanks 1000ltr double layer (cylindrical vertical with closed top) including float valve hoisted and fixed in position including removing /dismantling of old water tank
Supply and fix 25 mm bore GI tubing medium grade laid in trenches / floor or fixed to wall in any length with screwed and socket joints together with all galvanised GI fitting such as sockets, bends, elbows, tees, reducers, unions, jointing materials etc and pressure testing, washing out complete all as specified and directed
Supply and fix 25 mm dia ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed, complete all as specified and as directed
Supply and fix 25 mm bore Gun Metal gate valve with iron wheel head ISI Marked screwed both ends suitable for GI tubing complete all as specified and directed
Taking down carefully, copper/aluminium point wiring (Light, fan, socket or power) complete, including fittings and fixtures such as switches, ceiling roses, regulators, sockets etc., and making good disturbed surfaces of walls floors, etc., complete all as specified and as directed by Engineer-in-Charge.
Material and labour for point wiring complete with single core multi stranded Copper conductor FRLS cable of size 1.5 sqmm PVC insulated unsheathed 1100 volt grade in and including PVC conduit suitable size including Tee junction bends etc concealed in wall/fixed on ceiling and PVC switch board hylam sheet of 3mm thick including M.S. sunken boards of suitable size for housing switched sockets etc including 1.5 sqmm. green PVC insulated wire for earth continuity. including Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills sunshades, shelves, lintels, etc.; and cutting chases for concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth in brick wall for One light point/Exhaust fan point controlled by one switch complete all as specified and as directed by Engineer-in-Charge
All as per item No 109 here in before One fan point controlled by one switch and one regulator
All as per item No 109 here in before One 3 pin switch socket outlet point 5 amps on same board with other switches.
All as per item No 109 here in before One 3 pin switch socket outlet point 5 amps on independent board.
All as per item at sl No.109 here in before but with copper conductor cable for one 3 pin socket outlet, 15 amps independent, with cable 4 Sqmm size and 4 Sqmm earth continuity conductor, complete all as specified and as directed by Engineer-in-Charge.
Material and labour Point wiring complete with 1.5 sqmm single core FRLS PVC insulated and unsheathed cable 1100 volts grade with multistranded copper conductor drawn through and including PVC casing and caping and all accessories fixed to walls / roofs / floors / ceiling etc. and including provision of 1.5 sqmm copper cable as earth continuity conductor and connected to common earth dolly, including fabricated steel terminal box made out of 1.60mm thick MS sheet concealed in walls, with 3mm thick laminated sheet top cover/Pre moulded PVC switch board for housing the switches, socket outlets, fan regulators etc., all as specified and as directed for One light point controlled by one way switch
All as per item No 114 here in before One 3 pin switch socket outlet point 5 amps on independent board.
Supply and fix in replacement of switch piano flush type single pole one way 5 Amp all as specified and directed.
Supply and fix switch piano flush type single pole one way 5 amps, complete all as specified and as directed by Engineer-in-Charge
Supply and fix switch socket outlet 3 & 2 pin (multi pin) 5 amps flush/box type, complete all as specified and as directed by Engineer-in-Charge
Supply and fix switch socket outlet, 2 in 1, 3 pin 15 and 5 amps, controlled by one switch flush/box type complete all as specified and as directed by Engineer-in-Charge.
Supply and fix ceiling rose surface Bakelite 65 x 50 mm 3 terminal, complete all as specified and as directed by Engineer-in-Charge
Supply and fix lamp holder(angle type) PVC body with back plate suitable for batten fittings, complete all as specified and as directed Engineer-in-Charge
Supply and fix fan speed regulator, electronic suitable for single phase AC, 240 volts, 50 Hz,100 watts, complete all as specified and as directed by Engineer-in-Charge
Taking down and refixing ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified and as directed.
Taking down and refixing old serviceable exhaust fan and connecting up including providing of cable from ceiling rose/connector to fan complete all as specified and as directed.
Supply and fix energy efficient LED Smart bright batten 22 watt fitting 4ft in length nano diffuser technology to ensure minimum loss in light transmitted, long life of over 30000 hours including lamp and connecting with twin core sheathed cable from fitting to ceiling rose all as specified and as directed.
Supply and fix 25W New generation energy saving & environmental friendly long life versatile pressure dia cast aluminium IP65 road way luminaire with high power LEDs as light and electronic driver complete with necessary brackets (made out of 25 mm bore GI light grade pipe approx. 0.6 M long) nuts, bolts etc to be fixed as on walls complete as directed.
Supply & fix in repair LED holder type non dimmable bulb 10 watt complete all as specified and as directed by Engineer-in-Charge.
Supply and fix smart bright floods light 30w Led connecting with twin core sheathed cable from fitting to ceiling rose
Supply and fix Post top decorative gate light complete all as specified and as directed by Engineer-in-Charge
Supply and fix sheet metal enclosures Loadline distribution board TPN, 4 ways 415 volts, with 200 amps rated bus bar, with IP 42 protection and double door, suitable for mounting MCBs and in and including 63A MCCB as incoming complete all as specified and as directed including taking down old MCB DBs complete.
Supply and fix metal enclosure distribution board SPN, 2 way 240 volts, with 200 amps rated bus bar, with IP 42 protection and double door, suitable for mounting MCBs, complete all as specified and as directed by Engineer-in-Charge . Note:- Incoming & Outgoing connections from the DB shall be provided with proper lugs/thimbles etc...
Supply and fix in repair metal enclosure distribution board SPN, 8 way 240 volts, with 200 amps rated bus bar, with IP 42 protection and double door, suitable for mounting MCBs, including taking down old MCB/DB, complete all as specified and as directed.
Supply and fix MCB single pole, 240 volts, 5 to 32 Amps, all as specified and as directed.
Supply and fix MCB SPN 240 volts, 5 to 32 Amps, all as specified and as directed.
Supply and fix Wall mounting fan electric driven single phase 230 volts, oscillating type, 400 mm sweep, high quality with high speed motor and balanced blades and three leafed with 3 core copper cable of suitable size, complete all as per specified.
Material and labour for sub main wiring complete with two runs of 6 Sqmm FRLS single core PVC insulated in sheathed single core cable 1100 volts grade, multistranded with copper conductor (ISI Marked) drawn through and including PVC conduit suitable size including Tee junction bends etc concealed in wall/fixed on ceiling and PVC switch board hylam sheet of 3mm thick including M.S. sunken boards of suitable size for housing switched sockets etc including 1.5 sqmm. green PVC insulated wire for earth continuity. including Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills sunshades, shelves, lintels, etc.; and cutting chases for concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth in brick wall complete all as specified and as directed by Engineer-in-Charge. Note : (1) Two runs of cable one run of conduit & one run of earth continuity conductor shall be measured as one running metre.
Material and labour for earthing complete with galvanised steel earth plate electrode 60 x 60 cm x 6 mm thick buried directly in ground ( earth pit not less than 2.25 M deep below ground level) with top edge of the plate not less than 1.5 Meter below normal ground level connected to GI wire 4 mm dia by means of bolts, nuts , check nuts and washers of GI and GI tubing 20 mm bore light grade for earth lead protection up to main earth test point and including concrete pit in PCC (1:3:6) type C1 pre cast RCC (1:2:4) type B1 cover slab 54 x 54 x 5 cm with one handle for lifting made out of 8 mm dia MS bar, wire mesh, 20 mm bore GI tubing (LG) for watering, charcoal or coal and salt in alternate layers including excavation earth work complete all as specified and directed electrical plate No. 3 of SSR part - I
Supply, lay, test and commissioning underground XLPE insulated and PVC sheathed, armoured heavy duty UG cable, suitable for earthed system, laying in trenches/duct sleeving through pipe in duct, ISI marked with aluminium stranded conductor 1100 volt grade of cross section area 3.5 Core 25 sq mm
Supply, lay, test and commissioning underground XLPE insulated and PVC sheathed, armoured heavy duty underground cable, suitable for earthed system, laying in trenches/duct sleeving through pipe in duct, ISI marked with aluminium stranded conductor 1100 volt grade of cross section area 2 C x 6sq mm
Supply and lay cable protection pipe of HDPE double wall corrugated (DWC) including couplers, bends etc of size 50mm OD and ID 38 mm confirming to IS 14930 -II and ISI Marked all specified and directed
Demolition of brick work built in cement mortar or lime mortar complete all as specified and as directed.
DEEPAK AGENCIES
ANITA VARMA ENTERPRISES
RPG AND COMPANY
Nirman Construction Company
RADHA GOVIND CONSTRUCTION
M/s S U Enterprises
M/s Bismi Builders & Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .