| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.7 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder. | |
| 2 | L2₹35.4 L+₹1.6 L (4.80%)Rejected-Finance | L2 | Rejected-Finance Not Lowest. | |
| 3 | L3₹35.4 L+₹1.7 L (5.01%)Rejected-Finance | L3 | Rejected-Finance Not Lowest. |
Tender Value
₹30.8 L
EMD Value
₹61,600
Closing Date
13 Dec 2021, 6:00 pmClosed
GE Kamptee
Garrison Engineer, Kamptee Cantt - 441 001
SPECIAL REPAIRS TO BLDG NO 75 OR MD ACCN AT R LINES AND PROVN OF 57 GEYSERS OF 25 LTR CAPACITY ALONG WITH ALLIED FITTINGS FOR 44 MD AND 13 OTM ACCN OF 414 ASC BN MKTG TA AT KAMPTEE
2021_MES_474086_3
8323/E8
Open Tender
Civil Works
Item Rate
120 days
Kamptee
Class D, Cat a (i)
7 documents required · 7 mandatory
₹500
Yes
GE Kamptee
₹61,600
Yes
30 Dec 2021
20 Nov 2021
15 Dec 2021
20 Nov 2021
13 Dec 2021
1 Dec 2021
Amount
Dismantling of asbestos cement (Corrugated, semi corrugated etc) of any thickness including ridges hips valleys as in roof covering complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar beddeing (but not backing), removing serviceable tiles to store and debris complete all as specified and as directed.
Dismantling mild steel work of any description not otherwise provided for complete all as specified and directed.
M&L for 0.50mm thick prepainted galvalume aluminium zinc coating G.I. based corrugated steel sheet of any colour having tensile strength of 550 MPA as in roof covering, fixed with and including self tapping brass screw as per manufacturer instructions complete all as specified and directed.
S&F mild steel work such as roof trusses (framed), trussed, purlins and heavy bracket framing (Beam, Tee, angle, Channel or flat section) including distance pieces, cleat etc Fe 410-W Gde E-250 quality-A complete all as specified and directed.
M&L for non-skid ceramic tiles 7 to 8mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over 15mm thick screed bed of cement mortar (1:6) complete all as specified and directed.
All as per item No 6 above but as in skirting with 10mm backing in cement mortar (1:4) complete all as specified and directed.
M&L for coloured non skid ceramic tiles 7 to 8mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc set and jointed in neat cement slurry and pointed with white or coloured cement to match over and including 15mm thick screed bed of cement mortar (1:6) etc complete all as specified and as directed.
M&L for glazed ceramic coloured tiles 300mm x 450mm, on vertical surface such as skirtings/ dados set and jointed in neat cement slurry and pointed in coloured cement to match and including 10mm thick backing coat in CM (1:4) finished even and fair complete all as specified and directed.
Taking down existing water proofing treatment including screed bed and disposal of rubbish outside of MD land and hacking for key, scrubbing down with water complete all as specified and directed.
M&L for provision of water proofing treatment by using APP torch on mineral/ slate finished membrrance over roof and vertical surfaces including preparation of surfaces and applying oil based bituminous primer coat @ 0.30 ltr per sqm on clean and dry surface and then providing APP membrane having non woven polyster film reinforcement with 3mm thick and weight not less than 3.00 kg/sqm and finished on top with mineral/ slate finished torch on system laid with 100mm & 150mm over lap on side & end laps resepectely all as per manufacturers instructions over and including rendering 20mm thick in cement mortar (1:4) including WPC on concrete surfaces complete all as specified and directed. Note:- WPT shall be carried out through authorized applicator.
Supply only liquid integral water proofing admixture of make Pidilite or its equivalent complete all as specified and directed.
Demolition of RCC in suspended work and disposal of unserviceable materials, debris and rubbish to a distance not exceeding 100 m complete all as specified and directed.
M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed.
M&L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs not exc 20 cm wide complete all as specified and directed.
M&L for RCC (1:2:4) type B1 (using 20mm graded stone aggragate) for slab supported on walls, beams and coloumns in floors roofs, landings, balconies, canopies, deck slab and in shelves and the like complete all as specified and directed.
S&F mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending and binding with mild steel (anneal) wire not less than 0.90mm dia complete all as specified and directed.
Dismantling stone slabs and tiles of any description or thickness in floors, aprons etc complete all as specified and directed.
M&L for machine cut kota stone slab flooring 20-25 mm thick over cement screed base 20mm thick in CM (1:4) laid and jointed wih grey cement slurry mixed with pigments to match the shade of the slab including rubbing and mirror polishing as required by E-in-C complete all as specified and directed.
M&L for machine cut kota stone slab 18-25 mm thick in riser of steps, skirting, dado and pillar 10mm thck back plaster in CM (1:4) laid and jointed wih grey cement slurry mixed with pigments to match the shade of the slab complete all as specified and directed.
S&F pre-polished granite 20mm thick fixed on platform/ shelves over 20mm thick screed bed in cement mortar (1:4) including necessary moulding etc complete all as specified and directed.
Demolition of un-reinforced cement concrete in ground floors and pavings not exceeding 15cm thickness, (Below or above ground level) and disposal of unserviceable materials, debris and rubbish to a distance not exceeding 100 m complete all as specified and directed.
M&L for 75mm thick PCC (1:3:6) type C1 (using 20 mm graded stone aggregate), as in plinth protection/ path and finishing surfaces even & smooth without using extra cement including mist filling in the joint complete all as specified and directed.
M&L for PCC type D2 (1:4:8) (using 40mm graded stone aggreate) as in foundation, filling and mass concrete complete all as specified and directed.
M&L for chequered tiles 300 x 300 x 25 mm thick, rubber pressed glossy, rubber finished, set jointed and pointed in neat and cement slurry in floors with grey cement and pigment including screed bed or bedding layer of mortar 15mm thick for laying floor finishes in cement mortar (1:6) complete all as specified and directed.
M&L for machine pressed precast conctete interlocking paver block, rubber finished any shape and size confirming to IS 15658-2006 of 60mm thickness, with grey cement and pigment M-35 Grade etc complete all as specified and directed.
M&L for providing, cement concrete in roof kerbs or mud stops, rounded or chamfered on edges as in chajjas type B1 (1:2:4) (using 20mm graded stone aggregates) complete all as specified and directed.
Demolition of brick work, built in cement mortar or cement lime mortar including all quoins, pillars etc and disposal of unserviceable materials, debris and rubbish to a distance not exceeding 50m as complete all as specified and directed.
M&L for brick with fly ash brick old size straight of curved on plan exc 6m mean radius built in CM (1:6) complete all as specified and directed.
All as per item No 29 above but half brick thick wall in CM (1:4) complete all as specified and directed.
Taking down cement plaster on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water, etc including removal of debris, complete all as specified and directed.
M&L for rendering 10mm thick on brick work or concrete surfaces with CM (1:6) finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick in CM (1:4) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 5mm thick on surfaces of ceiling in cement mortar (1:4) and finished fair and even complete all as specified and as directed.
M&L for preparing newly plastered walls surfaces and applying three coats white wash over wall surfaces complete all as specified and directed.
M&L for prepartion of new plastered surface and applying two coats of oil bound distemper over a coat of cement primer and wall care putty complete all as specified and directed.
M&L for complete removal of existing treatment and applying two coats of oil bound distemper over a coat of cement primer and wall care putty complete all as specified and directed.
M&L for preparation of old plastered surfaces of wall and applying two coats of white wash complete all as specified and directed.
M&L for preparation of old decorated wall surfaces and applying two coats of exterior grade emulsion paint over a coat of primer complete including scaffoldings etc complete all as specified and directed.
M&L for preparation of new wall surfaces and applying two coats of exterior grade plastic emulsion paint over a coat of primer complete including scaffoldings etc complete all as specified and directed.
Taking down chowkat or frame with shutter (without taking off shutter from the frame) not exc. 1.5 sqm each, making good disturbed surfaces and removing materials from site of work complete all as specified and directed.
All as per item No 41 above but of size exc 1.5 Sqm and not exc 4 Sqm each complete all as specified and directed.
Taking down shutter of any description exc 1 Sqm but not exc. 2 Sqm each and removing from site complete all as specified and directed.
M&L for MS framed work of Fe-290 (Gde E-165) as in doors or gates of angle or other section with gusset plates, rails, braces, MS Plates etc, complete, drilled for fixing of steel sheeting or other covering. doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed.
S&F 30mm thick factory made flush shutters solid core construction with block board core and plywood face panels commercial type on both sides complete all as specified and directed.
S&F 30mm thick 2nd class hard wood factory made glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a), kiln seasoned and chemically pressure treated complete all as specified and as directed.
S&F anodised aluminium frame coloured powder coated for windows, ventilators, partitions with one or more rebates including joining cleat for fixing etc complete all as specified and directed.
Supply, Fabrication and fixing anodised coloured powder coated aluminium windows, ventilators shutters, sliding type without sash bars, alumiium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber gasket, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 No) hinges type B-21, 100mm long (2 No) suitable handle (1 No) complete all as specified and directed. Note:- Glazing/ gauzing shall be measured and paid for separately under respective items.
S&F in repairs 5.5mm thick tinted sheet glass ordinary quality and glazing with Al glazing clips & EPDM beading in square exc 0.5 sqm in each pane complete all as specified and directed.
S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or galvanised wire staples complete all as specified and directed.
S&F 4mm thick sheet glass ordinary quality, glazing with oil putty and glazing pin and wood bid in square not exc. 0.5 sqm in each pane complete all as specified and directed.
M&L for framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
S&F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S square tube, suppling and fixing in opening as per specification complete all as specified and directed.
S&F factory made solid PVC moulded door shutter, 28 to 30mm thick (stiles), with 4mm thick moulded laminated PVC sheet on the front face & 4mm plain colour PVC sheet on back face, with wood free EPS supplying & fixing in frame at site as per specification & drawing complete all as specified and directed.
S&F butt hinges stainless steel (ISI Marked) of 100mm size complete all as specified and as directed.
S&F 150mm aluminium anodised barrel tower bolts of extruded section complete all as specified and as directed.
S&F 125 mm aluminium handles, cast type, anodised complete all as specified and directed.
S&F 250mm aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast-aluminium alloy and fixed complete all as specified and directed.
S&F in repairs 150mm aluminium anodised barrel tower bolts of extruded section complete all as specified and as directed.
S&F in repairs 125 mm Aluminium handles, cast type, anodised complete all as specified and directed.
S&F in repairs 250 mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast-aluminium alloy and fixed complete all as specified and directed.
M&L for preparation of new wooden surface of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M&L for applying one coat of synthetic enamel paint to old painted wooden surfaces of any description, not oterwise described, over 10 cm width or girth including preparaton of surfaces complete all as specified and directed.
M&L for preparation of new steel surfaces of any description not otherwise described, exc 10 cm width or girth & applying with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for preparation of old steel surfaces of any description not otherwise described, exc 10 cm width or girth & applying with one coats of synthetic enamel paint complete all as specified and directed.
Cutting chases for concealed water tubing or concealed conduit wiring, etc and making good, cutting not exc 10 cm girth in cement mortar (1:3) complete all as specified and directed.
Taking up or down 15mm steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed.
Taking up or down 20mm steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed.
S&F GI tubing 15 mm bore medium grade with all fittings and fixed to wall and connection complete all as specified and directed.
S&F GI tubing 20 mm bore medium grade with all fittings and fixed to wall and connection complete all as specified and directed.
Refixing old steel tubing and connections 15mm bore in new or old position (Walls, ceiling, floors, etc.) complete all as specified and directed.
S&F in repairs vitreous china white squatting pan "Orissa Pattern" size 580 x 440mm, with integrated foot rest (excluding flushing sistern, flush pipe etc) including making good to floor complete all as specified and directed.
S&F in repairs Wash Hand basin (flat back or angle back) of size 550 x 400mm, white including vitreous china pedestal waste pipe, chain and plug, porcelain stopper including for & pinning in ends of brackets including supply & fixing of waste pipe complete all as specified and directed.
S&F in repairs 10 ltr capacity PVC valve less symphonic action type flushing cistern low level, white with inlet ball valve float and handle including bracket etc complete all as specified and directed. Make:- Prayag Cat No 501 or equivalent.
S&F in repair bib tap 15mm dia cast copper alloy with crutch or butter fly handle screwd for iron pipe or for brass ferrule and fixed complete all as specified and directed.
S&F in repairs chromium plated shower rose with or without swivel joints of 125mm dia including fixing to 15mm bore of pipe complete all as specified and directed.
S&F in repairs pillar tap 15mm dia, cast copper alloy, with capstan heads, chromium plated screwed down high pressure with or without lettered Hot or Cold with scrwed shanks and fly nuts, screwed for iron pipe and fixed complete all as specified and directed.
S&F in repair long shank and cup (concealed type) stop valve 15 mm dia chromium plated fancy type, high pressure with crutch or butter fly handle screwd for iron pipe or union and fixed complete all as specified and directed.
S&F in repair PVC connection 15 mm dia, 450 mm long including PTMT check nut complete all as specified and directed.
S&F in repairs stop valve /angle valve 15mm dia cast copper alloy chromium plated fancy typehigh pressure with crutch or butter fly handle screwd for iron pipe or union and fixed complete all as specified and directed.
S&F in repairs 25mm dia stainless steel curtain rod of approved quality including cutting and fixing to curtain brackets complete all as specified and directed.
S&F for fancy type curtain brackets of approved quality fixed to wall with screws complete all as specified and directed.
S&F in repairs towel rail 20mm dia of chromium plated fixed with and including chromium plated brass screws and wooden/ plastic cleats complete all as specified and directed.
S&F in repair 100 mm dia PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed.
S&F sinks made of stainless steel, 1mm thick for kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified and directed.
S&F waste fitting, 40mm brass, chromium plated for sink, basin, etc with long screwed shank and fly nut complete all as specified and directed.
S&F in repairs 40mm bore of pipe low density polyethylene pipe (LDPE) of pressure rating 6kg/cm fixed complete all as specified and directed.
S&F PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed.
S&F in repair 110mm bore PVC (SWR) pipe, single socketed in any length with rubber ring joints, fixed to walls with stack clamp every one mtr apart complete all as specified and as directed.
S&F in repair 75mm bore PVC (SWR) pipe, single socketed in any length with rubber ring joints, fixed to walls with stack clamp every one mtr apart complete all as specified and as directed.
S&F in repairs PVC (SWR) bends of 75mm dia complete all as specified and directed.
S&F in repairs PVC (SWR) bends of 110mm dia complete all as specified and directed.
Dismantling water tank of capacity exc 250 ltr & not exc 500 ltrs and removing to store of any description complete all as specified and directed.
S&F 500 ltrs capacity rotational moulded triple layer anti bacterial HDPE polyethylene water storage tanks (Cylindrical vertical with closed top) hoisted and fixed in position including connections including 20mm bore PTMT float valve complete all as specified and directed.
M&L for gun-metal, globe or gate valves, 15mm bore with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
M&L for gun-metal, globe or gate valves, 20mm bore with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
Dismantling boarding, any description, fixed in any position with nails complete all as specified and directed.
S&F 0.8mm mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred complete all as specified and directed.
S&F 1.00 mm mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred complete all as specified and directed.
M&L for mild steel Mortice lock, vertical type, size 100 mm 4 levers complete all as specified and directed.
Removing building materials etc to a distance of 1500m or under, beyond the lead included in the rates, including loading, unloading and stacking at the destination complete all as specified and directed.
Demolition of cement concrete bed in hauching and breaking up drain pipes SGSW set in cement mortar of the 150mm dia complete all as specified and directed.
Dismantling cast iron pipe of 100mm dia jointed in cement mortar and taking out trenches, if required complete all as specified and directed.
M&L for PCC (1:4:8) type D2 (using 40mm graded stone aggregate) as in bed to drain pipe 100mm bore including packing under and hauching against the sides of pipe after they are laid and tested complete all as specified and directed.
M&L for 150mm bore SGSW drain pipe grade A laid in trenches and jointed in CM (1:1) complete all as specified and directed.
S&F to wall, cast iron soil waste and vent pipes, 100mm dia in any length with or without ears with cement joints complete all as specified and directed.
Fixing and testing of electric water heater, grouting bolts and nuts in wall as required including provision and connection of flexible pipes with pipeline and testing for flow of hot and cold water properly and making good to surface complete all as specified and directed. Note:- Geysers will be supplied from AGE E/M stores under Sch 'B' items under contractor arrangement to carry at site without damage.
Cutting existing steel tubing for alterations or additions, insertion of tee, bends etc of water pipe for geyser inlet complete all as specified and directed.
S&F GI tubing medium grade with all fittings to wall or laid in floors complete all as specified for 15mm bore complete all as specified and directed.
S&F stop valves fancy type chromium plated, high pressure, screwed both end for iron pipe or for union and fixed of size 15mm bore complete all as specified and directed.
S&F bib taps, fancy type chromium plated, screwed for iron pipe or for brass ferrule and fix bore dia of pipe 15mm complete all as specified and directed.
Taking down point wiring with aluminum conductor cable of light point fan & socket light & power complete including light fittings any type switches, sockets, ceiling rose, switch boards, bell/buzzer, bell push, tube light fitting, regulator etc, and making good to the disturbed surfaces of walls/ floor etc to match with existing surfaces including white washing/ colour washing/ distemper to match with existing wall/ floor/ ceiling finishes complete all as specified and directed.
Taking down sheet metal enclosure DB, MCB, main switch etc and making good disturbed surfaces to match with existing surfaces complete all as specified and directed.
Taking down sub main wiring of any size/ capacity complete all as specified and making good disturbed surfaces to match with the existing surfaces complete all as specified and directed.
M&L for point wiring 1100 volt grade single core FRLSH PVC insulated and unsheathed cable with multistranded copper conductor 2.50 sqmm drawn in and including electrical grade PVC conduit not less than 20mm dia with IS 9537 (Part-III) 1983 marked medium grade/PVC caping casing on surface of wall/ ceiling including FRLSH PVC insulated unsheathed earth wire with multistranded copper conductor of size 2.50 sqmm pressed steel modular boxes sunk on wall for mounting of modular switches, switch sockets, fan regulator etc including modular cover with frame any size complete all as specified and making good disturbed surfaces for one power point controlled by one switch. Note:- Cost of cable provided from sub main DB to respective switch board in rooms shall be included in the quoted point wiring rate. All switches, fan, sockets, ceiling roses and holders shall be connected to common earth dolly.
M&L for point wiring 1100 volt grade single core FRLSH PVC insulated and unsheathed cable with multistranded copper conductor 1.50 sqmm drawn in and including electrical grade PVC conduit not less than 20mm dia with IS 9537 (Part-III) 1983 marked medium grade concealed on surface of wall/ ceiling including FRLSH PVC insulated unsheathed earth wire with multistranded copper conductor of size 1.50 sqmm pressed steel modular boxes sunk on wall for mounting of modular switches, switch sockets, fan regulator etc including modular cover with frame any size complete all as specified and making good disturbed surfaces for one light point controlled by one, one way switch. Note:- Cost of cable provided from sub main DB to respective switch board in rooms shall be included in the quoted point wiring rate. All switches, fan, sockets, ceiling roses and holders shall be connected to common earth dolly.
All as per item No 116 above but one ceiling /exhaust fan point controlled by one switch and regulator complete all as specified and directed.
All as per item No 116 above but one 3 pin 5 amp socket out point on the same board with other switches complete all as specified and directed.
All as per item No 116 above but one 3 pin 5 amps socket out let point on independent board complete all as specified and directed.
All as per item No 116 above but one bell/buzzer point controlled by one bell push complete all as specified and directed.
All as per item No 116 above but wiring with 2.5 sqmm multi stranded cable and earth wire with copper conductor of size 2.5 sqmm for 15 amps power point complete all as specified and directed.
M&L for sub main wiring with two single core PVC FR LSH insulated unsheathed stranded copper conductor and earth wire 1100 volt grade and drawing into PVC conduit not less than 20 mm medium grade concealed in wall of size 2x4.0 Sqmm with earth wire of 1x4.0 Sqmm complete all as specified and directed. Note :- Accessories for point/sub main wiring like PVC junction box, bend, Tee, elbow shall be of same make. Two run of 4 sqmm & one run of 4 sqmm & one run of PVC conduit shall be measured in one unit length.
S&F ceiling rose surface type 2/3 terminal 5 amps complete all as specified and directed.
S&F Bell ding dong, AC 230 volts, single phase complete all as specified and directed.
S&F lamp holder insulated body with back plate for angle/ batten fitting complete all as specified and directed.
S&F modular switch one way, 6A, 1 module complete all as specified and directed.
S&F modular switch one way 16A, 1 module complete all as specified and directed.
S&F modular bell push 6A, 1 module complete all as specified and directed.
S&F modular socket 6A, 2/3 pin combined, 2 module complete all as specified and directed.
S&F modular socket 6A/ 16A, 2/3 pin combined, 2 module complete all as specified and directed.
S&F modular fan step regulator, 120 watt 2 module complete all as specified and directed.
S&F highly durable surface mounted 18/20 watts LED batten/surface constructed of fire retardant engineering grade extruded aluminium body 100 lumen per watt, min 2000 lumen and decorative end cap complete with driver including 3 core 1.0 sqmm copper conductor cable for connection and accessories complete all as specified and directed. Make:- CG cat No LDL-20-CDL or in Bajaj/ Philips / Luker / Halonix / Shakti.
S&F light fitting 9W bulk head luminaries with lamp holders etc with all accessories and including connecting up with twin core twisted flexible cable suitable size of 230V, 50HZ complete all as specified and directed. Make:- CG cat No LBHP-10-CDL or in Philips/ Wipro/ Luker/ Halonix / Shakti.
S&F building security light LED 25W with Lumen O/P 1800 with driver with rated voltage 240 V, 50Hz, including mounting GI (made out of 25 mm dia light grade pipe 0.8 m bent two shape including FI clamps nut bolts etc) complete all as specified and directed. Make:- CG cat No LSTS-25-CDL-M or in Philips/ Wipro/ Luker / Shakti.
S&F sheet metal enclosure single pole & neutral for 240 volts 8 way with 200 Amp rated bus bar flush /surface mounting double door complete all as specified and directed.
S&F sheet metal enclosure single pole & neutral for 240 volts 4/6 way with 200 Amp rated bus bar flush /surface mounting double door complete all as specified and directed.
S&F MCB single pole 240 volt 6 to 40 amps 10 KA breaking capacity, 'C' series complete all as specified and directed.
S&F MCB single pole and neutral 240 volt 6 to 40 amps 10 KA breaking capacity, 'C' series complete all as specified and directed.
S&F MCCB triple pole and neutral 415 volt 40 to 60 amps 10 KA in enclosure connecting with DB including 10sqmm X 4 core FRLSH wire complete all as specified and directed.
S&F MCB triple pole and neutral 415 volt 40 to 60 amps 10 Ka complete all as specified and directed.
S&F in repairs energy meter boxes single phase weather proof fitted with glass and bakellite sheet recess mounting size 270 x 225 x 130mm fixing and connecting eletronic meter up to 40 Amps complete all as specified and directed.
M&L for earthing complete with galvanized street earth plate electrode 600 x 600 x 6mm thick buried directly in ground (earth plate not less than 2.25mtr deep below normal ground level) with top edge of the plate not less then 1.50 mtr below the normal ground level connected to galvanized earth lead wire 4.00 mm dia by means of bolts nuts check nuts & washer of galvanized iron or steel all as shown in electrical plate No 5 connected to earthing test point all as specified and testing on completion including the material and labour for:- (a) Excavation and earth work or drilling hole for electrode in any type of soil. (b) PCC pit in cement concrete (1:2:4) type B-1. (c) Pre cast RCC cover with suitable handle 40mm thick in PCC (1:2:4) reinforced with welded steel wire fabric weighting not less than 1.87 Kg/sqmm. (d) Funnel with watering pipe of GI 20mm nominal bore medium grade and Aluminum lugs etc all as specified. (e) 15mm nominal bore medium grade GI protection pipe up to 7.50 meter long for protection of earthing lead. (f) Requisite quantity of charcoal and common salt. (g) Connection to earthing test point and testing on completion.
Fixing only exhaust fan complete with frame and louvers including grouting bolts etc in wall or frame and necessary connections complete all as specified and directed. Note :- Exhaust fans will be provided as Sch 'B' items form AGE E/M yard and to be transported to location without damage under contractor's arrangement.
NOTE:- SCHEDULE OF CREDIT (Amount shall be deducted offline from the total quoted amount to workout the net contract sum to be considered for acceptance.) [(-) Rs.43,939.00]
M/s B S Jain
M/s M.G. Hargunani
Bidder Name
M/s B S Jain
M/s Jagdish Staioners and General Stores
M/s M.G. Hargunani
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .