Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹37.8 LAccepted-AOC AT PO KALAMCHHUIN DIST ANGUL PIN 759103 | KALAMCHHUIN | ANGUL | ODISHA | 759103 | L-1 | Accepted-AOC ACCEPTED AND AWARDED BY COMPETENT AUTHORITY | |
| 2 | L-2₹32.8 L+₹69,800.09 (2.17%)Rejected-Finance AT PO REMUAN TALCHER DIST ANGUL ODISHA 759100 | TALCHER | ANGUL | ODISHA | 759100 | L-2 | Rejected-Finance SINCE THE BIDDER IS NOT L-1 | |
| 3 | Rejected-Technical AT PO SURYA NAGAR HATATOTA TALCHER DIST ANGUL ODISHA PIN 759100 | TALCHER | ANGUL | ODISHA | 759100 | - | Rejected-Technical DOCUMENTS NOT COMPLIED ASPER NIT |
Tender Value
₹34.5 L
EMD Value
₹43,200
Closing Date
26 Jun 2023, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SO EnM LINGARAJ AREA
OFFICE OF THE GENERAL MANAGER, LINGARAJ AREA, AT/PO- DEULBERA COLLIERY, DIST- ANGUL, ODISHA, 759102
Diversion work of 33KV OH Line ( F-1 and F-2) of Lingaraj Area near Bharatpur Quarry to ashpond area of Jagannath Colliery
2023_MCL_281450_1
GM/LA/SO/EnM/e-Ten/23-24/14 DT-13.06.23
Open Tender
Electrical and Maintenance Works
Item Rate
60 days
LINGARAJ AREA
AS PER NIT
4 documents required · 4 mandatory
₹43,200
4 Oct 2023
13 Jun 2023
27 Jun 2023
14 Jun 2023
26 Jun 2023
14 Jun 2023
14 Jun 2023 - 19 Jun 2023
Amount
Erection of Metallic pole of following length in cement concrete 1:3:6( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc as required. Above 11 mtrs. And upto 13 mtrs.
Supply and erection of galvanized stay set for 33KV overhead lines complete with 19/20 mm dia x 1.8 mtr long stay rod ,anchor plate of size 45 cm x 45cm x7.5mm thick, thimble ,stay clamps , turn buckle(20mm x 600mm), 7/4.00mm dia G.I. stay wire and 33KV strain insulator etc in cement concrete 1:3:6(1 cement:3 coarse sand : 6 grade stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required.
Supply of two lengths of channel iron 100mm x 50mm x6mm(9.56kg/mtr.) double pole cross arm for three wire 33KV OH line conductors complete with through bolts & nuts for clamping to the poles, 50mmx 6mm M.S flats welded on one side to the channel iron and with bolts & nuts on other side for tying the cross arms together , including drilling holes for insulator pins/fittings, bolts,nuts & washers and painting with primer and finish paint as required.
Erection of double pole 03 wire cross arm for 11/22/33 KV O/H line etc. as required.
Supply and erection of a set of cross bracing frame work for 33kv OH line double pole structure having four members fabricated out of 65mm x 65mm x 6mm angle iron to to form a rectangle of minimum size 2400mm x 2800mm height complete with 50mmx 6mm flat iron clamps , bolts & nuts including drilling holes for insulator pin bolts, nuts, washers etc. and painting with primer & finish paint as required.
Supply of 8 SWG G.I wire.
Erection of G.I wire 8 SWG including binding etc as required.
Supply and erection of 33KV pin insulator complete with large steel head G.I., pin, nuts, washers etc as required.
Supply and erection of a set of three 33KV disc insulator for 33KV overhead lines with galvanised insulator fittings ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required
Erection of ACSR conductor of 7/3.35mm to 7/4.00mm Dia and above including binding etc.
Erection of disc insulator for 11KV over head lines
Trimming of trees of 33KV power feeder for one day
Dismantling of over head lines comprising of copper/ alluminium OHL conductor, G.I. wire, cross arms, insulators etc. as required.
Supply of clamps with M.S. nut, bolts and washers as required.
Supply of channel iron 100mm x 50mm x6mm(9.56kg/mtr.) v shape cross arm for two 33KV OH line conductors complete with 50mm x 6mm M.S flat iron clamps , bolts and nuts including drilliing holes for insulator pins bolts nuts, washers etc and painting with primer and finish paints as required.
Supply of channel iron 100mm x 50mm x6mm(9.56kg/mtr.) pole top bracket/ cross arm for single 33KV OH line conductors complete with 50mm x 6mm M.S flat iron clamps , bolts, nuts, including drilling holes for insulator pins, bolts , and nuts etc and painting with primer and finish paints as required.
Erection of pole top/straight two wire v shape two wire angle iron/channel iron cross arm on steel tubular/rail/P.C.C for 11/22/33 KV etc. as required.
Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required.
Dismantling of stay set embendded in cement concrete1:3:6 ( 1 cement: 3 Coarse sand: 6 graded stone aggregate 40mm nominal size ) foundation including excavation and refilling etc. as required.
Erection of stay set complete ( galvanized ) in cement concrete 1:3:6(1 cement:3 coarse sand : 6 grade stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required.
Total impact of GST plus Labour Cess [@ 1 % (BOCW Cess to be deducted from the RA bill as per the value of the work progress)] for the purpose of CTC
TRISHAKTI ENGINEERING
MESSERS UTKAL ELECTRICALS
stage.html
html • 0.04 MB
techsummary_291424.pdf
PDF • 0.21 MB
finsummary_291424.pdf
PDF • 0.21 MB
LOA140001.pdf
PDF • 0.31 MB
finance_291424.pdf
PDF • 0.19 MB
BOQ Comparative Chart
xlsx • 0.01 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .