Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.5 LAccepted-AOC 7 2 HARI MOHAN ROY L ANE CAL 15 700015 | KOLKATA | WEST BENGAL | 700015 | ₹2.5 L | L1 | Accepted-AOC 1ST LOWEST |
| 2 | L2₹2.6 L+₹2,148 (0.85%)Rejected-Finance 1087 LASKARHAT KOLKATA 700039 | KOLKATA | WEST BENGAL | 700039 | ₹2.6 L+₹2,148 (0.85%) | L2 | Rejected-Finance 2ND LOWEST |
| 3 | L3₹2.6 L+₹5,447 (2.15%)Rejected-Finance 15A PALMER BAZAR ROA D CAL 15 700015 | KOLKATA | WEST BENGAL | 700015 | ₹2.6 L+₹5,447 (2.15%) | L3 | Rejected-Finance 3RD LOWEST |
| Sl No | Description | Qty | Unit | S R ENTERPRISE L2 | S S ENTERPRISES L1 | M/S S S UDYOG L3 |
|---|---|---|---|---|---|---|
| 1.00 | DRAWING OUT OF THE EXISTING TRANSFORMER OIL FROM
INSIDE THE TANSFORMER TANK AND PRESERVING THE SAME IN THE REQUIRED NUMBER OF 200 LTRS. CAPACITY BARREL. | 2 | ONE ITEM | 14,800 ₹29,600 | 14,729 ₹29,458 Lowest | 14,910 ₹29,820 |
| 2.00 | OPENING THE TOP COVER OF THE TRANSFORMER AND
DISCONNECTION THE HV & LV CONNECTION FROM THE
BUSHING, THE CORE & COIL ASSEMBLY TO BE LIFTED FROM
TRANSFORMER TANK AND TO BE KEPT ON THE PROPER
PLACE WITH THE HELP OF A CHAINPULLEY BLOCK FOR
THOROUGH CLEANING. | 2 | ONE ITEM | 18,560 ₹37,120 | 18,413 ₹36,826 Lowest | 18,688 ₹37,376 |
| 3.00 | THOROUGH CLEANING AND REMOVING OF SLUDG FROM THE TRANSFORMER TANK, CORE & COIL ASSEMBLY BY HOT
TRANSFORMER OIL AS PER DIRECTION AND SPECIFICATION
OF ENGINEER - IN - CHARGE. | 2 | ONE ITEM | 16,700 ₹33,400 | 16,694 ₹33,388 Lowest | 16,850 ₹33,700 |
| 4.00 | RE-FIXING THE TRANSFORMER CORE & COIL ASSEMBLY IN
THE TANK AND RE-CONNECTION OF THE BOTH HV & LV
WINDINGS AS PER DIRECTION OF ENGINEER - IN - CHARGE. | 2 | ONE ITEM | 10,750 ₹21,500 | 10,741 ₹21,482 Lowest | 10,800 ₹21,600 |
| 5.00 | SUPPLY OF TRANSFORMER OIL (ELECTRO BRAND) FOR
TOPPING UP OF TRANSFORMER.. | 150 | LITER | 240 ₹36,000 | 232 ₹34,800 Lowest | 255 ₹38,250 |
| 6.00 | HIRE CHARGES OF TRANSFORMER OIL FILTRATION M/C. | 3 | DAYS | 2,780 ₹8,340 | 2,776 ₹8,328 | 2,775 ₹8,325 Lowest |
| 7.00 | HIRE CHARGES OF TRANSFORMER OIL BDV TESTING
MACHINE. | 2 | DAYS | 700 ₹1,400 | 693 ₹1,386 Lowest | 712 ₹1,424 |
| 8.00 | SUPPLY OF NEW GASKET & PETROLEUM JELLY. | 2 | ONE ITEM | 4,350 ₹8,700 | 4,339 ₹8,678 Lowest | 4,361 ₹8,722 |
| 9.00 | FOLLOWING TESTS HAVE TO BE CARRIED OUT FOR THE
CONSERVER TANK INCLUDING OIL LEVEL GLASS ETC. AS
REQUIRED.
A) RATIO TEST, B) HIGH VOLTAGE TEST (10KV DC FOR 1 MIN.),
C) WINDING RESISTANCE TEST, D) INSULATION RESISTANCE
TEST. | 2 | ONE ITEM | 18,499 ₹36,998 | 18,460 ₹36,920 Lowest | 18,550 ₹37,100 |
| 10.00 | ACIDITY TESTING OF THE TRANSFORMER OIL BY AN
AUTHORISED AND REPUTED AGENCY AND TEST RESULT IN
DUPLICATE TO BE SUBMITTED TO THE DEPARTMENT. | 2 | ONE ITEM | 1,910 ₹3,820 | 1,841 ₹3,682 Lowest | 1,915 ₹3,830 |
Tender Value
Refer Docs
EMD Value
₹5,075
Closing Date
25 Feb 2026, 2:00 pmClosed
EXECUTIVE ENGINEER (GRWW)
OFFICE OF THE EXECUTIVE ENGINEER (WATER SUPPLY) GARDEN REACH WATER WORKS, BIDHANGARH, KOL-66
REPAIRING, OVERHAULING, DE-HYDRATION, TESTING AND COMMISSIONING TWO NOS OF 630 KVA, 6KV /415V TRANSFORMER AT SUB-STATION OF CWPS-III,GRWW.
2026_KMC_1001953_1
KMC/EE/WS/GRWW/25-26/PH-II/53
Open Tender
Electrical Work/ Equipment
Item Rate
10 days
CWPS-III OF GARDEN REACH WATER WORKS
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
₹5,075
22 Aug 2026
9 Feb 2026
27 Feb 2026
9 Feb 2026
25 Feb 2026
9 Feb 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | DRAWING OUT OF THE EXISTING TRANSFORMER OIL FROM
INSIDE THE TANSFORMER TANK AND PRESERVING THE SAME IN THE REQUIRED NUMBER OF 200 LTRS. CAPACITY BARREL. | 2 | ONE ITEM | - | - |
| 2 | OPENING THE TOP COVER OF THE TRANSFORMER AND
DISCONNECTION THE HV & LV CONNECTION FROM THE
BUSHING, THE CORE & COIL ASSEMBLY TO BE LIFTED FROM
TRANSFORMER TANK AND TO BE KEPT ON THE PROPER
PLACE WITH THE HELP OF A CHAINPULLEY BLOCK FOR
THOROUGH CLEANING. | 2 | ONE ITEM | - | - |
| 3 | THOROUGH CLEANING AND REMOVING OF SLUDG FROM THE TRANSFORMER TANK, CORE & COIL ASSEMBLY BY HOT
TRANSFORMER OIL AS PER DIRECTION AND SPECIFICATION
OF ENGINEER - IN - CHARGE. | 2 | ONE ITEM | - | - |
| 4 | RE-FIXING THE TRANSFORMER CORE & COIL ASSEMBLY IN
THE TANK AND RE-CONNECTION OF THE BOTH HV & LV
WINDINGS AS PER DIRECTION OF ENGINEER - IN - CHARGE. | 2 | ONE ITEM | - | - |
| 5 | SUPPLY OF TRANSFORMER OIL (ELECTRO BRAND) FOR
TOPPING UP OF TRANSFORMER.. | 150 | LITER | - | - |
| 6 | HIRE CHARGES OF TRANSFORMER OIL FILTRATION M/C. | 3 | DAYS | - | - |
| 7 | HIRE CHARGES OF TRANSFORMER OIL BDV TESTING
MACHINE. | 2 | DAYS | - | - |
| 8 | SUPPLY OF NEW GASKET & PETROLEUM JELLY. | 2 | ONE ITEM | - | - |
| 9 | FOLLOWING TESTS HAVE TO BE CARRIED OUT FOR THE
CONSERVER TANK INCLUDING OIL LEVEL GLASS ETC. AS
REQUIRED.
A) RATIO TEST, B) HIGH VOLTAGE TEST (10KV DC FOR 1 MIN.),
C) WINDING RESISTANCE TEST, D) INSULATION RESISTANCE
TEST. | 2 | ONE ITEM | - | - |
| 10 | ACIDITY TESTING OF THE TRANSFORMER OIL BY AN
AUTHORISED AND REPUTED AGENCY AND TEST RESULT IN
DUPLICATE TO BE SUBMITTED TO THE DEPARTMENT. | 2 | ONE ITEM | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.93 MB
TECH53.pdf
Tender Documents • 0.44 MB
OIDDETAILS.pdf
Additional Documents • 0.33 MB
BOQ_2455429.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .