Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹86.3 LAccepted-Finance 10 A 1 JAHURA BAZAR LANE KASBA KOLKATA 700042 | KOLKATA | KOLKATA | WEST BENGAL | 700042 | ₹86.3 L | L1 | Accepted-Finance ACCEPTED |
| 2 | L2₹86.5 LRejected-Finance | ₹86.5 L | L2 | Rejected-Finance REJECTED |
| 3 | L3₹86.9 LRejected-Finance 2 102A SREE COLONY KOLKATA 700092 | KOLKATA | KOLKATA | WEST BENGAL | 700092 | ₹86.9 L | L3 | Rejected-Finance REJECTED |
| 4 | L4₹88.7 LRejected-Finance | ₹88.7 L | L4 | Rejected-Finance REJECTED |
| 5 | L5₹89.5 LRejected-Finance 1ST FR LP 13 4 749 ANANDA PUR KOLKATA WEST BENGAL PIN 700107 | KOLKATA | KOLKATA | WEST BENGAL | 700107 | ₹89.5 L | L5 | Rejected-Finance REJECTED |
Tender Value
₹86.9 L
EMD Value
₹1.7 L
Closing Date
3 Dec 2025, 3:00 pmClosed
Executive Engineer -I Alipore Division PWD
Executive Engineer_I Alipore Division PWD 2nd and 3rd Floor 32_Belvedere Road Alipore Kolkata_700027
R and Mtc of Outside and Common Area of Block J K L O and P including Plinth Protection and Drain Anglo Indian WC Replacement of Soil and West Water line Cons of Inspection pit for west water line Incld Roof treatment work at Block J K L and P with
2025_WBPWD_944641_1
WBPWDEEIALI/NIET44ASDIII/25-26
Open Tender
CIVIL WORKS
90 days
ALIPORE
Please refer Tender documents.
4 documents required · 4 mandatory
₹1.7 L
Yes
15 May 2026
11 Nov 2025
5 Dec 2025
11 Nov 2025
3 Dec 2025
11 Nov 2025
Dismantling R.C. floor, roof, beams etc. including cutting rods and removing rubbish as directed within a lead of 75 m. including stacking of steel bars.
1st floor
2nd floor
Dismantling artificial stone flooring upto 50 mm. thick by carefully chiselling without damaging the base and removing rubbish as directed within a lead of 75 m. Ground floor
1st floor
2nd floor
Taking out old damaged tarfelt from the roof, parapet etc. preparing the roof surfaces by removing all spoils, blisters, moss etc. from the working site and disposal of the same beyond the compound and cleaning the site in all respect as per direction of Engineer-in-Charge.
Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. upto 150 mm. thick In 2nd Floor Including Roof
In 3rd Floor Including Roof
Cutting chase upto 125 x 150 mm. and subsequent mending of damages. In brick wall [Cement-3.6 Kg/Mtr]
Cleaning the concrete surface by removing dirt and debris, marking defective locations and removing loose concrete by careful stripping untill hard surface is exposed, cutting the concrete to regular shape, wire brushing the exposed surface and removing debris from site complete as per direction of the Engineer - in - Charge.
Applying 2 coats of Non-Toxic Acrylic Polymer modified Paint having adhesive & waterproofing properties by mixing in proportion (1 liquid: 4 cementitious material) or as per manufacturer's specification for water proofing layer in water tank etc. (No Departmental Cement is required)
Supplying & laying 3mm thick pre-fabricated water proofing membrane conforming to EN 12311-1 & ASTMD 5147, manufactured with atactic poly propylene (APP) modified premium grade asphalt, specially reinforced with non-woven polyester core with polyester reinforcement @160 gms per sqm & both faces covered with thermo-fusible polyethylene film /MineraL on top face over a coat of primer @ 0.40 lit/sqm of manufacturer's specification on smooth,clean dry surface prepared wherever required.Lap joint shall be provided of 75 mm in longitudinal & 100 mm in transverse direction and fused using LPG/ Propane torch employing extra care ensuring full bondage, complete removal of entrapped air and sealing edges into grooves in appropriate manner as per direction of Engineer -in-charge all complete including materials,labour and applicable taxes. (Payment shall be made on the basis of finished surface area.). Membrane Property: Softening Point > 150 deg C, Cold Flexibility < -6 deg C, Tensile Strength, N/cm : 600 (longitudinal), 450 (transverse),
Making one set of scaffolding only for replacing glass panels, painting, uprooting plant and another repairing works of building and S&P works for external works only with 10 cm. dia bamboo as main posts at the rate of 1 metre centre to centre and 7.5 cm. dia bamboo ties @ 0.75 metre apart fitting and fixing with necessary coir, nails etc. as per direction of the Engineer-incharge. (This item should be executed only after prior approval of the Engineer-incharge). Firstly, one number to be paid and then labour rate for shifting up to further nineteenth (19) times @ 10% each time to be considered. If necessary further after twenty times of total use, another one number new and labour rate for shifting to be considered accordingly. Making Scaffolding of 10.95 M High
Shifting of 10.95 M High Scaffolding
Uprooting and removing plants from the surface of walls parapet etc and making good damages. (Repairing of damages to be paid separately). Small plant of girth of exposed stem upto 75 mm. lift upto 6 mtr.
125 mm. thick brick work with 1st class bricks in cement mortar (1:4). In First Floor
In Second Floor
125 mm. thick brick work with 1st class bricks in cement mortar (1:3). In Ground Floor
Brick work with 1st class bricks in cement mortar (1:6) In foundation and plinth In Ground Floor
Extra for using approved H.B netting in every third layer of 125 mm thick brick work in any floor.
Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity).
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes. Pakur Variety
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. Pakur Variety In Ground Floor including Roof
1st floor
2nd floor
3rd floor
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) (When the height of a particular floor is more than 4 m the equivalent floor height shall be taken as 4 m and extra for works beyond the initial 4 m ht. shall be allowed under 12 (e) for every 4 m or part hereof) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge. In Ground Floor including Roof
1st floor
2nd floor
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. Tor steel/Mild Steel SAIL/ TATA/RINL Ground floor
1st floor
2nd floor
Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. Floor With Sand Cement Mortar (1:4) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. Area of each tile upto 0.09 Sq.m Coloured decorative In Ground Floor
1st floor
2nd floor
Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. In ground floor. 3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement). Using grey cement. 35 mm. thick In Ground Floor
In First Floor
In 2nd Floor
M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr. In Ground Floor
In First Floor
In 2nd Floor
In 3rd Floor
Supplying 1.5mm thick M.S. sheet fitted and fixed on one or both faces of M.S./ W.I. gate etc. with point welding at not more than 150mm apart complete in all respect as per design including cost of all labour and materials. In Ground Floor
Supplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized (with required film thickness and specified colour / natural) matt finished conforming to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - In- Charge. (Payment will be made on finished length of the work). In 10-12 Micron thickness Annodizing film Natural white a) 2- track sliding window i) Bottom frame
a) 2- track sliding window ii) Top and side frame.
b) 3- track sliding window i) Bottom frame
b) 3- track sliding window ii) Top and side frame.
d) Shutter for all track sliding window. i) Bottom & Top member.
d) Shutter for all track sliding window. ii) Style side member.
d) Shutter for all track sliding window. iii) Interlock member.
g) Fixed glazing. i) Top, bottom and side member.
g) Fixed glazing. ii) Mullion.
g) Fixed glazing. iii) Glazing clip.
h) Louvered window. i) Top, bottom and side member.
h) Louvered window. ii) Louvered Section.
h) Louvered window. iii) Cleat angle ( Non-annodized).
Labour charge for fabrication and installation of composite door, window, partitions made from annodized extruded alloy aluminium sections for the following units:- (A) Glazed aluminium sliding windows made of extruded and annodized alloy aluminium sectios, fabrications, including cutting to proper shape and size, drilling and aligning of window shutter frame fitted with in built locking arrangements, sliding rollers and other necessary fittings, fixture, adhesives and joineries along with extruded neoprine or EPDM gasketing in between window frame and masonry work (walls, column, beam.lintels etc.) as well as between glass and shutter frame for fixing glass and Polysulphide sealant and in between shutter and window frame where necessary including cutting to requisite size and fixing glass as per drawing, specification and direction of EIC. The rate includes the hire charge of all tools and plants, including all incidental charges, adhesive, joineries such as screw, cleat angle etc. but excluding the cost of extruded aluminium sections, glass, neoprene / EPDM gasket, locking arrangement and rollers. i ) 2 track sliding window.
ii ) 3 /4 track sliding window.
iv ) Fixed glazing.
Supplying PVC rollers for sliding windows as per direction of Engineer in charge
Supplying maruti lock (100mm)
Supplying EPDM gusket of approved make and brand as per direction of Engineer in charge. i) For sliding windows a) 'T' shaped EPDM gasket for frames.
i) For sliding windows b) 'U' shaped EPDM gasket for frames.
Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987. 4mm thick coloured / tinted / smoke glass.
Supplying best Indian sheet glass panes set in putty and fitted and fixed with nails and putty complete. (In all floors for internal wall & upto 6 m height for external wall) 4 mm thick
Labour for taking out door and window frame including shutter for repair or replacement of different parts of the frame & refixing the same including mending good all damaes complete. (Concrete and brick work for mending damage will be paid separately) Upto area 2.5 Sq.m
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary. [Excluding cost of chipping over concrete surface] With 1:6 cement mortar 20 mm thick plaster In Ground Floor.
In 1st Floor.
In 2nd Floor.
In 3rd Floor.
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary. [Excluding cost of chipping over concrete surface] With 1:6 cement mortar 15 mm thick plaster In Ground Floor.
In First Floor.
In 2nd Floor.
In 3rd Floor.
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary. [Excluding cost of chipping over concrete surface] With 1:4 cement mortar 10 mm thick plaster In Ground Floor.
In First Floor.
In 2nd Floor.
In 3rd Floor.
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary. [Excluding cost of chipping over concrete surface] With 1:4 cement mortar 15 mm thick plaster In Ground Floor.
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary. [Excluding cost of chipping over concrete surface]. With 1:4 cement mortar. 20 mm thick plaster. In 2nd Floor.
In 3rd Floor.
Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc. NOTE:Cement 0.152 cu.m per 100 sq.m.
Stripping off worn out plaster and raking out joints of walls, celings etc. upto any height and in any floor including removing rubbish within a lead of 75m as directed.
Cement concrete (1:1.5:3) with graded stone chips 5.6 mm size with hexagonal square mesh wire netting, I.R.C. fabric mesh or X.P.M. fitted and fixed after tying the existing reinforcement on concrete without distributing the same and with proper scarping and cleaning the reinforcement anddisturbed concrete with wire brush etc. after applying a coat of cement including the cost of wire netting I.R.C or X. P. M. & cost of all handling and scaffolding complete as per direction of Engineer-in -charge. 37.5mm thick
Cleaning the concrete surface by removing dirt and debris, marking defective locations and removing loose concrete by careful stripping untill hard surface is exposed, cutting the concrete to regular shape, wire brushing the exposed surface and removing debris from site complete as per direction of the Engineer - in - Charge.
Applying 2 coats of bonding agent with synthetic multi functional rubber emulsion having adhesive and water proofing properties by mixing with water in proportion (1 bonding agent : 4 water : 6 cement) as per Manufacturer's specification [Cement to be supplied by the Department]
Cleaning the exposed reinforcement preferably upto full diameter by wire brush, applying two coats of polymer based rust removing compound left for 24 hours, removing the coating and then applying two (2) coats of polymer modified anti corrosive protective coating formulated to inhibit the corrosion of reinforcement as per manufacturer's specification] [Mode of measurement:The affected surface area of reinforcement shall be considered for payment]
Removal of rubbish,earth etc. from the working site and disposal
of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge
Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) : (Two coats) Luxury Quality
In First Floor.
In 2nd Floor.
In 3rd Floor.
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. One Coat In Ground Floor.
In First Floor.
In 2nd Floor.
In 3rd Floor.
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. In Ground floor (Two Coat) Premium 100% Acrylic Emulsion In Ground Floor
Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : On timber or plastered surface : With super gloss (hi-gloss) - Two coats (with any shade except white)
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : On steel or other metal surface : With super gloss (hi-gloss) - Two coats (with any shade except white)
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 (A) (i) Single Socketed 3 Meter Length (a) 75 mm
(A) (i) Single Socketed 3 Meter Length (b) 110 mm
(B) Fittings (iii) Door Tee (b) 110 mm
(B) Fittings x) Bend 87.5º (b) 110 mm
(B) Fittings xi) Door Bend (T.S.) (b) 110 mm
(B) Fittings xiv) Cross Tee with Door (b) 110 mm
(B) Fittings xv) Vent Cowl (b) 110 mm
(B) Fittings xxi) 110 X 110 P Trap 75 mm
(B) Fittings xxvi) Reducer 110 X 75 mm 75 mm
(B) Fittings Li) Nahani Trap 90 mm
Labour for fitting and fixing U.P.V.C.pipes for above ground work including cost of jointing materials etc. fitting and fixing all necessary specials, cutting pipes, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the Engineerin- charge. (Payment will be made on centre line measurement of the total pipeline including specials. (A) Above ground (i) 75 mm dia.
(A) Above ground (ii) 110 mm dia.
Supplying & laying Double Wall Corrugated (with external annular corrugation and smooth internal walls) High Density Polyethelene Pipes conforming to IS 16098 (Part-II):2013 having Stiffness Class of SN 8 with Ring Stiffness not less than 8.00 KN/Sqm. and Impact Resistance TIR value not more than 10% including necessary jointing materials for nonpressure underground Drainage, Sewerage & Cross drainage application. 200mm internal dia.
Constructing Inspection pit of inside measurement 600mm X 600mm X upto 600mm (depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides, bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling, 15 mm thick (1:4) cement plaster to inside walls and out-side walls upto G.L. and 20 mm.thick (1:4) plaster to bottom of the pit, providing necessary invert with cement concrete (1:3:6) with stone chips as per direction, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcements upto 1% and shuttering including 6 mm thick cement plaster (1:4) in all external surfaces of the slab and excluding one 560 mm dia. R.C.C. manhole cover of approved make supplied, fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials. i) With Pakur variety. (SAIL/TATA/RINL)
Supplying, fitting and fixing in position reinforced cement polymer concrete manhole /gully pit cover with matching frame.As per I.S-12592(M.D) 5 MT load bearing capacity gully pit cover with frame and hinge arrangement for opening of size Cover: 470 mm X 420 mm X 80 mm Frame: 590 mm X 550 mm X 170 mm opening: 380mm x 305mm Weight: 100 kg (approx)
Supplying, fitting and fixing in position R.C.C. Manhole/ pit cover of approved make with rim of approved make (Heavy type) 560 mm dia.
Cleaning silt of inspection pit.
Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) For Exposed Work PVC Pipes 15 mm Dia
20 mm Dia
25 mm Dia
32 mm Dia
40 mm Dia
50 mm Dia
Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) For Exposed Work PVC Pipes 15 mm Dia
20 mm Dia
25 mm Dia
32 mm Dia
40 mm Dia
Labour for dismantling G.I. pipe with fittings. 15 mm Dia
Supplying, fitting and fixing gunmetal wheel valve of approved brand and make tested to 21 kg per sq. cm. (for water lines only). 40 mm dia
Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer 2000 litre capacity
Labour for hoisting plastic water storage tank. Above 1500 litre upto 5000 litre capacity. Upto 4th story from G.L.
Lowering G.I. tank (upto and including 1812 litre capacity). From 4th story to G.L.
Labour for punching hole in plastic water storage tank upto 50 mm dia.
Supplying, fitting and fixing Anglo-Indian W.C. in white glazed vitreous china ware of approved make complete in position with necessary bolts, nuts etc. With 'P' trap (with vent)
Supplying, fitting and fixing Closet seat of approved make with lid and C.P. hinges, rubber buffer and brass screws complete. Anglo Indian Plastic (hallow type) white
Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specification with P.V.C. fittings complete,C.I. brackets including two coats of painting to bracket etc.
Supplying, fitting and fixing shower of approved brand and make. Polythene overhead shower of approved make 15 mm X 125 mm
Supplying, fitting and fixing bib cock or stop cock. Polythene Bib Cock / Stop Cock (HD) with metal inlet (EMCO / ATLAS or equivalent) 15 mm
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.29 MB
Tendernotice_2.pdf
PDF • 0.42 MB
BOQ_2243009.xls
BOQ • 0.44 MB
Download all tender documents and submit your bid