REPAIR/MAINT OF SOLAR LIGHT, GARDEN LIGHT AND OTHER ALLIED WORKS AT VARIOUS ZONES AT MILITARY STATION TALBEHAT
2023_MES_586949_1
AGE(I)/TBT/TOK-04/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
335 days
AGE I TALBEHAT
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
AGE I TALBEHAT
₹19,980
Yes
11 May 2023
24 Mar 2023
24 Apr 2023
31 Mar 2023
22 Apr 2023
7 Apr 2023
Amount
Taking down old unserviceable light fitting of any type and wattage.
Supply, fixing and testing high performance LED Street Light fittings of 70 Watts, energy saving and environment friendly long life pressure die -cast aluminium hosing high power LED as lighting source and lens embedded PC cover having TOP OPENING separate driver compartment with IP-66 Protection and impact resistance of IK07 with 10KV Built-in-Surge Protection Device suitable for pole dia 54 mm complete all as specified and directed
Supply, fixing and testing high performance LED Street Light fittings of 90 Watts, energy saving and environment friendly long life pressure die -cast aluminium hosing high power LED as lighting source and lens embedded PC cover having TOP OPENING separate driver compartment with IP-66 Protection and impact resistance of IK07 with 10KV Built-in-Surge Protection Device suitable for pole dia 54 mm complete all as specified and directed
Supply, fixing and testing in replacement High performance LED Flood light fitting/luminaires of 170 watt power consumption, made out of die cast aluminium housing, hermitically sealed to achieve IP 66 ingress protection, optical compartment shall be provided with heat resistant toughened glass, while control gear shall be provided with die cast aluminium cover for safety including multistage current constant voltage topology driver suitable to operate in input voltage range of 150V to 270V (nominal rated voltage-240V) with minimum 3KV surge protection. Power factor greater than 0.90 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire complete all as specified and directed.
Repair only LED Solar street light fitting all-in-one type 09 to 12 Watt,12 volt DC IP 65, cleaning of panels, and wiring as required complete all as specified and directed.
Replacement of 12 V inbuilt battery, lithium ferro phosphate for solar street light
Supply and fixing in replacement of LED Solar street light fitting 11/12 Watt 12 volt DC IP 65, including inbuilt 12V battery and auto lighting time sensor complete all as specified and directed.
Supply and fixing AC & DC Power Pack Box with inbuilt rechargeable battery, input AC volt 110V-220V and output DC 110 volt complete all as specified and directed.
Supply and fixing Solar light Panel 12 volt 50 watt complete all as specified and directed.
Supply, fixing and testing ALL-IN-ONE Solar street light with high efficiency mono crystalline solar PV module, Lithium Ferro phosphate battery with inbuilt BMS technology, high efficacy LED of 12 watts, MPPT solar charge controller & aluminium extruded body, with progressive intelligent dimming, backup for 02 days including mounting pole 6.0 m long, 50 mm dia med grade GI pipe with MS clamp and nut bolts and PCC complete all as specified and directed by Engineer-in-Charge
Supply and fixing LED driver 90 watt for street lights complete all as specified and directed.
Supply and fixing in replacement, street light bracket on RCC/Steel tubular pole made out of 40 mm dia bore G I Pipe light grade of length not less than 1.5 mtr bend to required shape for holding the fitting with providing the clamp nut, bolt and washer etc. of required size and 02 nos mild steel supporting clamps shall be made out of flat iron of suitable size of requisite length mild steel work shall be painted with two coat of aluminium paint over a coat of red oxide primer complete all as specified and directed by Engr-In-Charge. Make of GI Pipe:- JINDAL, PRAKASH, TATA.
S&F LED post top, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source and RUBY (CLEAR)-IP-65 protection of 40 watt, 6000K, 240 volt, 50Hz.
Repair of glow shine board on LED lights letters including taking down letters from glow shine board and refixing after repair and replacement of driver as required complete all as specified and directed by Engr-In-Charge. Note:- Repair of each letter will be measured separately
Repair of LED lights letters under item No. 14.00 and refixing the same as specified and directed
Supply and fixing rain proof LED driver 12 volt 200 watt complete all as specified and directed. Make CE RoHS cat No WCCEL- NF-12V-200W
Supply and fixing mount sturdy LED Bollard 1.0 mtr height with excellent light out put through its PMMA widow ensuring maximum illumination aspect in surrounding garden light 10 Watt, inbuilt driver, IP 65, 230 Volt, complete connection with PVC insulated multi stranded copper flexible wire twin core of suitable size from nearest source complete all as specified and as directed by Engineer-in-Charge.
Excavation in trenches not exceeding 1.5mtrs wide & not exceeding 1.5mtr in depth as in soft/ loose soil & getting out complete all as spfd & directed.
Returning , filling in spreading, leveling, watering & well Ramming in layers not exc 25cm thick complete all as spfd & directed.
Removing excavated material not exc 50mtr & deposited where directed at a level not exc 1.5mtr above the starting point complete all as specified and directed by EIC.
M&L for bricks common burnt sub class B designation for protection of cable complete all as spfd & directed.
Supply and laying m-sand for cushioning to underground cable in layers of 23 cm (8 cm deep before laying of cable and 15cm deep over the cable) after laying the cable in trenches including punning thickness up to 18 cm , complete all as specified and directed.
M&L in replacement of insulated heavy duty electric cables with Stranded aluminium conductor, 1100 volts grade, passing through trenches/ducts/pipes and climbing on poles/walls including fixing with proper size of aluminium lugs. For the following sizes. NOTE:- 1. Excavation and earth work to be measured and paid separately.
10 sqmm 2 core
10 sqmm 4 core
Supply and laying or fixing in replacement GI tubes light grade, on place of rusted GI pipe in support of cables, on pole/wall/laid in floor/in trenches of following size.
40 mm dia
25 mm dia
Note :- Debris obtained from all items should be removed in low lying areas as directed by Engr-in-charge out of MOD Land. (Rates quoted for items are deemed to be included for this, where removal of debris in the items is not considered.)
M/s Dinesh Kumar
M/S SHIVA TRADERS
HARNAM SINGH ANIL SINGH
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .