Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹14.6 Cr
EMD Value
₹8.8 L
Closing Date
12 Jan 2026, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Yes (up to 2 members)
No
Two Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
SOUTH
14 conditions · 2 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N OR 'V' Whichever is less; where. V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per ANNEXURE-XXXIII, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
a)The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i)Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii)Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii)One similar work costing not less than the amount equal to 60% of advertised value of the tender.
Defination of Similar Work :- "Work of Supply, Installation & Commissioning Of DAC." OR "Any Signalling work involving Supply, Installation & Commissioning of DAC."
7 conditions
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Tender document, Scope of work & GCC 2022 are attached with the tender.
Replacement of aged and wornout Motor type AC track circuits in Chhatrapati Shivaji Maharaj Terminus-Panvel, Kurla - Kalyan and Kalyan-Igatpuri - Lonavala sections of Mumbai Division.
CR-BB-SNT-SOUTH-2025-62~CR
CR-BB-SNT-SOUTH-2025-62
Open
Works - General
12 Months
Mumbai, Maharashtra
₹0
₹8.8 L
12 Jan 2026
11 Dec 2025
29 Dec 2025
122 items across 3 schedules · ₹7,08,48,630.89 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| 1 | Supply of Relay Rack Assembly complete with scaffolding, fixtures and accessories including MS Bars for fixing of relay plug board, string rods, fuse strips with bracket, 11 Way Bus Bars with cover and mounting brackets, runway for cable/wires, frame, base assembly etc. Siemens type & as per extant practice on C. Rly. Typical part list and Rack arrangement as per Sketch no SK- 727 and Rack plan as approved by Engineer in charge.(Inspection Agency-Consignee) | Set | 20.00 | 35,301.04 | 7,06,020.8 |
| 2 | Supply of Tag Blocks 200/160/120 way with polycarbonate cover as per IRS S 77- 2006(Rev.1) RDSO DRG. No. SA 24751, SA 24752 & SA 24753. Requirement of each type shall be specified by Engineer-in- charge.(Inspection Agency-Consignee) | Numbers | 250.00 | 1,414.88 | 3,53,720 |
| 3 | Supply of Main Cable Termination rack complete with scaffolding, fixtures & accessories including square bars for mounting 8-way terminal blocks, ladder, string rods, frame, base assembly, insulators, J bolt, nut/bolts & fasteners, backelite sheet, etc. Siemens type and as per extant practice on Central Railway. Typical part list and rack arrangement shall be as per sketch No. SK-727 with latest alterations.(Inspection Agency-Consignee) | Set | 10.00 | 30,404 | 3,04,040 |
| 4 | Supply of PVC Indoor Cable 1x60x0.6mm dia Colour coding of insulation of inner core shall be in six colour viz Blue, Red, Grey, Green, Brown & Black conforming to IRS 76/89 (Amd.3) or latest.(Inspection Agency- Consignee) | Kilometre | 5.00 | 3,00,675.81 | 15,03,379.05 |
| 5 | Supply of PVC Indoor Cable 1x40x0.6mm dia Colour coding of insulation of inner core shall be in eight colour viz Blue, Red, Grey, Green, Brown, Black, Yellow & White conforming to IRS 76/89 (Amd.3) or latest.(Inspection Agency-Consignee) | Kilometre | 5.00 | 1,97,250.4 | 9,86,252 |
| 6 | Supply of PVC Indoor Cable 1 x 24 x 1 mm dia Colour coding of insulation of inner conductor shall be in eight colour viz Blue, Red, Grey, Green, Brown, Black, Yellow & White conforming to IRS 76/89 (Amd.3) or latest.(Inspection Agency-Consignee) | Kilometre | 8.00 | 2,92,637.78 | 23,41,102.24 |
| 7 | Supply of Indoor Jumper Wire of various colour as per Railways standard practice of type ATC 1 x 0.6 mm dia.conforming to IRS 76/89 (Amd.3) or latest.(Inspection Agency- Consignee) | Kilometre | 30.00 | 8,647.71 | 2,59,431.3 |
| 8 | Supply of Indoor Jumper Wire ATC 1 x 1 mm dia. conforming to IRS 76/89 (Amd.3) or latest.(Inspection Agency-Consignee) | Kilometre | 20.00 | 13,093.54 | 2,61,870.8 |
| 9 | Supply of PVC flexible copper cable single core multistrand 1 x 2.5 Sq.mm (50 conductor each diameter 0.25 +/- 0.01) as p e r IS 694/2010 with latest amendment if any.with insulation thickness of 0.70mm nominal conductor resistance 7.98 ohms/Km and test parameters are as per IRS (S)76/89 (Amd.3).(Inspection Agency-Consignee) | Kilometre | 18.00 | 44,575.65 | 8,02,361.7 |
| 10 | Supply of PVC flexible copper cable single core multistrand 1 x 10 Sq.mm (80 conductor each diameter 0.40 +/- 0.01) as p e r IS 694/2010 with latest amendment if any.with insulation thickness of 1.0mm nominal conductor resistance 1.91 ohms/Km and test parameters are as per IRS (S)76/89 (Amd.3).(Inspection Agency-Consignee) | Kilometre | 3.00 | 1,41,059.3 | 4,23,177.9 |
| 11 | Supply of PVC flexible copper cable single core multistrand 1 x 16 Sq.mm (126 conductor each diameter 0.40 +/- 0.01) as per IS 2465/1984 & IS:694/2010 with latest amendment if any with insulation thickness of 1.0mm nominal conductor resistance 1.121 ohms/Km and test parameters are as per IRS (S)76/89 (Amd.3).(Inspection Agency-Consignee) | Kilometre | 3.00 | 2,09,928.3 | 6,29,784.9 |
| 12 | Supply of PVC flexible copper cable single core multistrand 1 x 25 Sq.mm (196 conductor each diameter 0.40 +/- 0.01) as per IS 2465/1984 & IS:694/2010 with latest amendment if any with insulation thickness of 1.2mm nominal conductor resistance 0.780 ohms/Km and test parameters are as per IRS (S)76/89 (Amd.3).(Inspection Agency-Consignee) | Kilometre | 6.00 | 3,26,216.47 | 19,57,298.82 |
| 13 | Supply of wire 16/0.2 (Blue, Red, Grey, yellow, Brown, Black, White as per site engineer instruction) finolex/polycab/delton make. IRS S-76/89 (Amd.3), BS: 4808 Part-2. Wire to be procured from RDSO approved vender.(Inspection Agency-Consignee) | Kilometre | 30.00 | 6,445.17 | 1,93,355.1 |
| 14 | Supply of low maintenance Lead Acid Secondary Cells 2V 80 AH as per spec. IRS 88/2004 with latest amendments.(Inspection Agency-RDSO) | Numbers | 600.00 | 1,997.16 | 11,98,296 |
| 15 | Supply of Track Feed Transformer 230V/110V-130V Single Phase 3 KVA single phase as per spec. IRS S-72/88 (Amd.2) with latest amendments.(Inspection Agency- RDSO) | Numbers | 30.00 | 13,802.29 | 4,14,068.7 |
| 16 | Supply of Rubber Mat 5mm thick for use in signalling installation.(Inspection Agency- Consignee) | Kg | 400.00 | 129.53 | 51,812 |
| 17 | Supply of 63 A rating, 4 pole changeover switch disconnector with dual shaft position & staggered terminals with sheet steel enclosure and extended handle of Siemens/ L&T/ HAVELLS/ LEGRAND make.(Inspection Agency-Consignee) | Numbers | 30.00 | 7,604.64 | 2,28,139.2 |
| 18 | Supply of QSPA1 relay, 24VDC, slow to pick up, 8F-4B, along with plug board, retaining clip and connectors conforming to BRS:933A, IRS : S60, IRS:S34 & IRS:S23(Inspection Agency-RDSO) | Numbers | 350.00 | 4,414.93 | 15,45,225.5 |
| 19 | Supply of QTA2 AC immunised track relay, 9 Ohm, 2F.1B, along with plug board, retaining clip and connectors conforming to BRS:939A, 966 & Appendix F2, IRS:S34 & IRS:S23(Inspection Agency-RDSO) | Numbers | 300.00 | 3,859.82 | 11,57,946 |
| 20 | Supply of QBAT track Relay, AC immunised, 2F-2B contacts, 9 ohms. complete with plug board, retaining clip & connectors as per RDSO / SPN/84 Ver 2.0 or latest.(Inspection Agency-RDSO) | Numbers | 50.00 | 6,603.79 | 3,30,189.5 |
| 21 | Supply of INDICATIVE TYPE OF FUSE INSERTS. IRS S:78-92 With holder 1.6 A (System, Rapid or Malnad make).(Inspection Agency-Consignee) | Numbers | 800.00 | 79.92 | 63,936 |
| 22 | Supply of INDICATIVE TYPE OF FUSE INSERTS. IRS S:78-92 With holder 0.6 A (System, Rapid or Malnad make).(Inspection Agency-Consignee) | Numbers | 800.00 | 77.19 | 61,752 |
| 23 | Supply of INDICATIVE TYPE OF FUSE INSERTS. IRS S:78-92 With holder 6 A/10A ( D-Type Bharat Linder, L&T or HEVELLS Make).(Inspection Agency-Consignee) | Numbers | 100.00 | 270.59 | 27,059 |
| 24 | Supply of INDICATIVE TYPE OF FUSE INSERTS. IRS S:78-92 Without holder 1.6 A (System, Rapid or Malnad Make).(Inspection Agency-Consignee) | Numbers | 800.00 | 23.02 | 18,416 |
| 25 | Supply of INDICATIVE TYPE OF FUSE INSERTS. IRS S:78-92 Without holder 0.6 A (System, Rapid or Malnad Make).(Inspection Agency-Consignee) | Numbers | 800.00 | 23.02 | 18,416 |
| 26 | Supply of INDICATIVE TYPE OF FUSE INSERTS. IRS S:78-92 Without holder 6A/10A (D-type Bharat Linder, L&T or HEVELLS Make). (Inspection Agency-Consignee) | Numbers | 200.00 | 95.7 | 19,140 |
| 27 | Supply of PPTC Fuse GP 60-185 UL-94 certification (1.6 Amps) for internal/external current. Make: LITTLEFUSE, FUZETEC, TYCO, BOURN, RAYCHEM etc.(Inspection Agency- Consignee) | Numbers | 1000.00 | 10.14 | 10,140 |
| 28 | Supply of PPTC Fuse GP 60-400 UL-94 certification (12V/4A) TF, TR Circuit. Make: LITTLEFUSE, FUZETEC, TYCO, BOURN, RAYCHEM etc.(Inspection Agency-Consignee) | Numbers | 1000.00 | 8.56 | 8,560 |
| 29 | Supply of PPTC Fuse GP 30-100 (24V/1.4A) TPR, Circuit. Make: LITTLEFUSE, FUZETEC, TYCO, BOURN, RAYCHEM etc.(Inspection Agency-Consignee) | Numbers | 1000.00 | 8.56 | 8,560 |
| 30 | Supply of PPTC Fuse GP 250-185UL-94 certification (24V/4A) 110V AC for track chargers. Make: LITTLEFUSE, FUZETEC, TYCO, BOURN, RAYCHEM etc.(Inspection Agency-Consignee) | Numbers | 1000.00 | 8.56 | 8,560 |
| 31 | Resin cored wire as per specification No. IS:1921-1975 with Alloying element percentage as 63% SN (Tin) and / 37% Pb (Lead) with percentage of various impurities not exceeding the values Sb (Antimony) 0.2% maximum , Cu (Copper) 0.1% maximum, As (Arsenic) 0.05% maximum, Fe (Iron) 0.02% maximum & other impurities mainly Al, Zn & Cd shall be limited. The flux shall be free from corrosive action as per clause 5.2 & flux percentage may be used as per requirement.(Inspection Agency- Consignee) | Kg | 80.00 | 1,252.58 | 1,00,206.4 |
| 32 | Lacing thread rolls, black, wax coated (100 mtrs).(Inspection Agency-Consignee) | Numbers | 200.00 | 66.15 | 13,230 |
| 33 | Fabrication and supply of Board made of White sunmica sheet over 12 mm thick particle/laminated/ wooden board covered with 5 mm thick perspex transparent sheet in aluminium/ steel frame and Painting of SWR/Track insulation plan etc.(Inspection Agency-Consignee) (UNIT NUMBER SHOULD BE READ AS Per Sq mtr. ) | Numbers | 20.00 | 7,303.52 | 1,46,070.4 |
| 34 | Design, fabrication and supply of Fuse Auto Changeover System for 32 Nos. of external non-deteriorating type fuses or 'G' type fuses from 0.6A Amp to 4A Amp capacities used in signalling circuits. System shall have 8 cards with monitoring arrangement of 4 fuses in one card. As per RDSO Spec. RDSO/SPN/209/2012 Ver.2.0 or latest amendment if any.(Inspection Agency- Consignee) (UNIT NUMBER SHOULD BE READ AS No. of Modules ) | Numbers | 30.00 | 26,760.23 | 8,02,806.9 |
| 35 | Design, fabrication and supply of Fuse Auto Changeover System for 24 Nos. of external non-deteriorating type or 'G' type fuses from 4 A to 10 Amp capacities generally used for point operaton circuits. System shall have 6 cards with monitoring of 4 fuses in one card. As per RDSO Spec. RDSO/SPN/209/2012 Ver.2.0 or latest amendment if any. (Inspection Agency-Consignee) (UNIT NUMBER SHOULD BE READ AS No. of Modules ) | Numbers | 10.00 | 40,513.38 | 4,05,133.8 |
| 36 | Supply of Phenolic 10mm thick sheet, grade P3 in standard size of 1.22X1.22 Mtr as per spec. No IS 2036 of 1995.(Inspection Agency-Consignee) | Numbers | 50.00 | 5,250.48 | 2,62,524 |
| 37 | Supply of FIBRE GLASS INSULATING FIRE RETARDENT SHEET OF 10 MM THICKNESS AS PER ISO:10192-1982, Dielectric strength- 25KV/mm with glass content 25 to 34% in standard size of 1.10x1.10 Mtr. as per Spec. No. IS:10192-1982.(Inspection Agency- Consignee) | Numbers | 100.00 | 5,300 | 5,30,000 |
| 38 | Supply of ARA Terminal blocks with links made of PBT Specn No.IRS/75/2006(Rev-2) with latest amendments and RDSO Drg.No.SA-23741A Alt.4, SA-23745 Alt.5, SA- 23746, SA-23748 Alt.4 & SA-23756A Alt.3. (Inspection Agency-RDSO) | Numbers | 8000.00 | 72.61 | 5,80,880 |
| 39 | Supply of cartridge fuse block made of PBT as per RDSO Drg No SA-23748 Alt 4, SA- 23749 & Spec No IRS S 75/2006 with latest amendment. Fuse block shall be suitable for round head type voltage fuses.(Inspection Agency-RDSO) | Numbers | 500.00 | 162.94 | 81,470 |
| 40 | Supply of round head type non detoriating type low voltage cartridge fuse as per Specn No IRS/S/78/92 with latest amendments 2A/4A/6A capacity(Inspection Agency-RDSO) | Numbers | 500.00 | 70.13 | 35,065 |
| 41 | Supply of Tik-tak, piano type switches,5 A (as per IS Specification).(Inspection Agency- Consignee) | Numbers | 200.00 | 33.41 | 6,682 |
| 42 | Supply of three pole plug and socket 5 Amp (as per IS Specification).(Inspection Agency- Consignee) | Numbers | 200.00 | 230.86 | 46,172 |
| 43 | Supply of Lamp 110V/24W, 2 Pin for Loc. (Inspection Agency-Consignee) | Numbers | 200.00 | 22.73 | 4,546 |
| 44 | Supply of earth electrode assembly as per Drg.No. CR/S&T/SK-815(Inspection Agency- Consignee) | Numbers | 150.00 | 1,078.08 | 1,61,712 |
| 45 | "Maintenance Free Earth as per RDSO/SPN.197/ 2008 or latest consisting of : 1) Copper bond steel electrode 3 Mtr long 17mm dia with copper bonding thickness of min. 250 micron & UL listed & marked-01 No. 2) Earth enhancement compound RDSO Approved in sealed bag of 10 Kgs - 03 No. 3) Copper strip 150 x 25 x 6mm - 02 No. 4) Copper strip 300 x 25 x 6mm - 01 No. 5) 35 Sqmm Copper Cable to connect earth electrode to MEEB - 15 Mtr Approx. (Inspection Agency-RDSO)" | Set | 120.00 | 17,786.33 | 21,34,359.6 |
| 46 | Supply of 35 Sq.mm Multistrand Single Core PVC Insulated Copper for connecting earth bus bar to earth electrode.(Inspection Agency-Consignee) | Metre | 1000.00 | 406.33 | 4,06,330 |
| 47 | Supply of Copper Tape 25x6 mm (Bonding ring conductor) mounted on insulated standoff (1 round).(Inspection Agency- Consignee) | Metre | 100.00 | 795.4 | 79,540 |
| 48 | Supply of 300x25x6 mm Cu Equipotential Bus Bar.(Inspection Agency-Consignee) | Numbers | 20.00 | 1,334.85 | 26,697 |
| 49 | Supply of Track Lead Juction Boxes as per C.Rly Drg. No.RST 11509 made from fiiber glass alongwith terminal blocks.(Inspection Agency-Consignee) | Numbers | 500.00 | 1,047.98 | 5,23,990 |
| 50 | Supply of B type choke to specn.No.IRS.S.65/83 (Amd.3) with latest amendments.(Inspection Agency-RDSO) | Numbers | 400.00 | 3,666.35 | 14,66,540 |
| 51 | Supply of adjustable Track Feed Resistance disc type 7.5/15/30 ohms as per RDSO Drg. No. SA 20161-66/M (Adv) with latest amendments (with Phenolic moulded base). (Inspection Agency-RDSO) | Numbers | 500.00 | 1,288.14 | 6,44,070 |
| 52 | Supply of Track feed battery chargers, 110V AC input 2, 4 to 6 V DC Output to Specn.No.IRS.89/2013 Ver.1.0 with latest amendments. Charger shall be suitable for charging 80 AH battery.(Inspection Agency- RDSO) | Numbers | 350.00 | 2,430.3 | 8,50,605 |
| 53 | Supply of Channel Pins single groove, galvanised, 7 mm suitable for 4mm dia bonding wire as per spec No. IRS: S 17-75 Revision 3.(Inspection Agency-Consignee) | Numbers | 4000.00 | 2.01 | 8,040 |
| 54 | Supply of PVC jacketed wire rope for Track Lead connections. PVC jacketed wire rope should be of Galvanised steel wire rope 6 mm dia (6x19 stranded wire with steel core of 6 mm dia) sheathed with PVC 2mm wall thickness, overall thickness being 10 mm. PVC sheath should be made of type 6 compound as per IS 5831 of 1984 Reaffirmed 2001 and steel wire rope as per IS: 2266:2019. Reclaimed or recycled material should not be used.(Inspection Agency-Consignee) | Metre | 12000.00 | 52.29 | 6,27,480 |
| 55 | Supply of 8 SWG GI wire (4mm dia) suitable for track circuit rail bonding. As per IRS Specification S:13 - 62 (Inspection Agency- Consignee) | Kg | 8000.00 | 86.82 | 6,94,560 |
| 56 | Supply of Hydrometer, Exide make or similar for measuring specific gravity of Battery Graded acid with mounting stand in location Boxes.Consignee inspection under manufacturer certificate.(Inspection Agency- Consignee) | Numbers | 80.00 | 283.64 | 22,691.2 |
| 57 | Supply, installation, testing and commissioning of Track Battery Charger Monitoring System for 2V/4V/6V/8V batteries with accessories at nominated stations. General Scheme to be approved by Engineer incharge.(Inspection Agency-Consignee) | Numbers | 400.00 | 1,667.01 | 6,66,804 |
| 58 | Supply of DWC HDPE pipe with one snap fit coupler and 'O' ring fire resistant, anti rodent, in 6 meter length of size 120 mm outer dia as per RDSO/SPN/204/2011 Ver. 1.1 with Amd.1 or latest. (Inspection Agency- Consignee) | Metre | 2000.00 | 321.43 | 6,42,860 |
| 59 | Supply of RCC Trunking with capping. Size 250mm x 200mm. Drg.No.RST/C/291/A(Inspection Agency- Consignee) | Metre | 200.00 | 873.72 | 1,74,744 |
| 60 | Supply of RCC Trunking with capping. Size 150mm x 150mm. Drg.No.RST/C/291/A(Inspection Agency- Consignee) | Metre | 200.00 | 818.16 | 1,63,632 |
| 61 | Supply of RCC pipes half round of size 150mm dia outer and 100 mm dia internal 1 mtr long matching to IS No. 458/2003 amendment-1 with Rev.4.(Inspection Agency-Consignee) | Numbers | 200.00 | 206.14 | 41,228 |
| 62 | Supply of Modular terminal block of 2.5 sq.mm 2 in 2 out type disconnect type terminal along with as per RDSO/SPN/189/2004 Rev 3.0. The current capacity of 16 Amps and more. The terminal should have marking at centre to view description from front. Material to be procured from RDSO approved firms only. (Inspection Agency-Consignee) | Numbers | 5000.00 | 117.12 | 5,85,600 |
| 63 | Supply of DIN Channel for the terminals 1 Mtrs each.(Inspection Agency-Consignee) | Numbers | 180.00 | 216.73 | 39,011.4 |
| 64 | Supply of End plates for modular terminal block.(Inspection Agency-Consignee) | Numbers | 1000.00 | 23.39 | 23,390 |
| 65 | Supply of End Clamp for modular terminal block.(Inspection Agency-Consignee) | Numbers | 1000.00 | 16.81 | 16,810 |
| 66 | Supply of Marker Card as per customer spec. (10x10)(Inspection Agency-Consignee) | Numbers | 1000.00 | 83.81 | 83,810 |
| 67 | Fuse terminal block with LED indication upto 2.5 sq.mm screw type one in one out (suitable for (400 mA, 630mA, 1A. 1.6A, 2A, 4A, 6.3A & 10A) as per RDSO/SPN/189/2004. (without fuse)(Inspection Agency-Consignee) | Numbers | 400.00 | 181.85 | 72,740 |
| 68 | End plate for through terminal block with LED indication.(Inspection Agency- Consignee) | Numbers | 1000.00 | 13.62 | 13,620 |
| 69 | Fuse links of (400 mA, 630mA, 1A. 1.6A, 2A, 4A, 6.3A & 10A) (Inspection Agency- Consignee) | Numbers | 500.00 | 43.14 | 21,570 |
| 70 | Shorting link insulated Grey in colour. (Inspection Agency-Consignee) | Numbers | 5000.00 | 14.75 | 73,750 |
| 71 | Operating tool (operating tool, screw driver & stripper) as per Annexure-XIX.(Inspection Agency-Consignee) | Numbers | 20.00 | 8,660.2 | 1,73,204 |
| 72 | Supply of Thermo shrink Cable Jointing kit (Reinforced) TSF-2 type generally conforming to RDSO specification RDSO/SPN/TC/57/2015 Rev 1 with modified kit contents as per CSTE's Specification No.CR/SPN/TC/57(A)/2015 Dt. 06.01.2015(Table-A) to be suitable for jointing both 10/20/50 pair PIJF and 4/6 Quad cables along with sub-kit (Table-B) for armour continuity.(Inspection Agency- Consignee) | Numbers | 20.00 | 2,991.97 | 59,839.4 |
| Schedule total | ₹2,94,06,024.61 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .