Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.7 LAccepted-AOC 44B CIRCULAR GARDEN REACH ROAD KOLKATA 700 023 | KOLKATA | WEST BENGAL | 700023 | ₹35.7 L Quoted ₹36.9 L | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹39.1 LRejected-Finance GC ROAD ABDUL LATIF ROAD PO TITAGARH PS KHARDAH DIST NORTH 24 PARGANAS KOLKATA 700119 | 24 PARAGANAS NORTH | WEST BENGAL | 700119 | ₹39.1 L | L2 | Rejected-Finance HIGHER THEN L1 BIDDER |
| 3 | L3₹41.4 LRejected-Finance 3 IBRAHIM ROAD KHIDDERPORE KOLKATA 700023 | KOLKATA | WEST BENGAL | 700023 | ₹41.4 L | L3 | Rejected-Finance HIGHER THEN L1 BIDDER |
| 4 | Rejected-Technical 106 1 RAJA RAMMOHAN SARANI KOLKATA 700 009 | KOLKATA | WEST BENGAL | 700009 | - | - | Rejected-Technical REJECTED DUE TO NOT ENLISTED IN APPROPRIATE CATEGORY |
| 5 | Rejected-Technical | - | - | Rejected-Technical REJECTED DUE TO NOT ENLISTED IN APPROPRIATE CATEGORY |
| Sl No | Description | Qty | Unit | KWALITY CONSTRUCTION L2 | EASTERN REFRIGERATION AND ELECTRICAL CO L3 | INDIA ELECTRICAL EQUIPMENTS L1 |
|---|---|---|---|---|---|---|
| 1.00 | Taking down carefully Window Type / Split Type / Tower Type Air Conditioner 1/1.50 / 2.00/3 Ton capacity, from its location and removing dirt and dust from interior and exterior of the Air Conditioner and washing the condensor and evaporator with varmi clean solution and other areas by soap solution, spraying pressurised water on condensor and evaportor with proper protection of electrical fixtures and connection, drying by blowing air, and placing in same position complete all as directed. | 134 | Each Job | 1,400 ₹1.9 L | 1,325 ₹1.8 L | 770 ₹1.0 L |
| 2.00 | Taking down unserviceable Rotary/reciprocatory Compressor from Air Conditioner Window Type / Split type 2 Ton capacity of any make & type and Supply and Fixing reconditioned sealed compressor suitable for 2.0 TR window/split type Air conditioner including vacumminishing, initial charging of oil along with new foundation rubber pads, nut and bolts including testing on full load complete all as directed
Note: Cost of charging of gas is not included in this item and will be paid under Appropriate item of schedule. | 2 | Each Job | 15,800 ₹31,600 | 15,900 ₹31,800 | 16,200 ₹32,400 |
| 3.00 | All as per serial item No. 2.00 mentioned here-in-before but for air conditioner of window Type / Split type 1/1.5 Ton capacity | 10 | Each Job | 16,100 ₹1.6 L | 15,150 ₹1.5 L | 15,850 ₹1.6 L |
| 4.00 | Taking down unserviceable Rotary/reciprocatory Compressor from Air Conditioner Window Type / Split type 2.0 Ton capacity of any make & type and Supply and Fixing new sealed rotary type compressor suitable for 2.0TR window type/split type Air conditioner including vacumminishing, commissioning ,testing and initial charging of oil of air conditioner along with new foundation rubber pads, nut and bolts including testing on full load complete all as directed
Note: Cost of charging of gas is not included in this item and will be paid under Appropriate item of schedule. | 2 | Each | 15,500 ₹31,000 | 15,600 ₹31,200 | 16,200 ₹32,400 |
| 5.00 | All as per serial item No. 4.00 above but for air conditioner of window Type / Split type 1/1.5 Ton capacity.
Note: Cost of charging of gas is not included in this item and will be paid under Appropriate item of schedule. | 10 | Each | 15,100 ₹1.5 L | 15,140 ₹1.5 L | 15,850 ₹1.6 L |
| 6.00 | All as per serial item No. 4.00 above but for inverter AC of window / Split type of capacity 2.0 ton.
Note: Cost of charging of gas is not included in this item and will be paid under Appropriate item of schedule. | 1 | Each | 16,450 ₹16,450 | 16,580 ₹16,580 | 16,200 ₹16,200 |
| 7.00 | All as per serial item No. 4.00 above but for inverter AC of window / Split type of capacity1.5 ton.
Note: Cost of charging of gas is not included in this item and will be paid under Appropriate item of schedule. | 1 | Each | 15,990 ₹15,990 | 15,998 ₹15,998 | 15,850 ₹15,850 |
| 8.00 | Supply and Fixing in repair compressor as per existing make suitable for 1.5 TR Chiller including vacumminishing, commissioning ,testing and initial charging of oil complete all as directed including taking down old unserviceable one complete.
Note: Cost of charging of gas is not included in this item and will be paid under Appropriate item of schedule. | 1 | Each | 9,500 ₹9,500 | 9,558 ₹9,558 | 18,200 ₹18,200 |
| 9.00 | Supply and fixing in repair compressor 2.5 TR per existing make 3 phase including vacumminishing, commissioning ,testing and initial charging of oil complete all as directed including taking down old unserviceable one complete.
Note: Cost of charging of gas is not included in this item and will be paid under Appropriate item of schedule. | 1 | Each | 10,000 ₹10,000 | 10,090 ₹10,090 | 23,800 ₹23,800 |
| 10.00 | Supply & fixing of new strainer including testing including taking down old unserviceable one complete all as specified and directed . | 2 | Each | 260 ₹520 | 265 ₹530 | 198 ₹396 |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
8 Dec 2025, 6:00 pmClosed
SHRI RAKESH KUMAR
GARRISON ENGINEER (CENTRAL) KOLKATA NAPIER ROAD HASTINGS 700022
REPAIR TO COOLING APPLIANCES LIKE REFRIGERATOR, WATER COOLERS, CENTRAL/SPLIT TYPE ACS AND CERTAIN E/M MAIN WORKS AT DGQA, IGS, HASTINGS, OD ALIPORE, SAHAPUR MIL CAMP, RASPUNJA MIL CAMP UNDER GE (C) KOLKATA
2025_MES_740134_1
8872/E8
Open Tender
Miscellaneous Works
270 days
Kolkata
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE(CENTRAL) KOLKATA
₹70,000
Yes
9 Feb 2026
17 Nov 2025
9 Dec 2025
17 Nov 2025
8 Dec 2025
2 Dec 2025
17 Nov 2025 - 1 Dec 2025
Amount
Taking down carefully Window Type / Split Type / Tower Type Air Conditioner 1/1.50 / 2.00/3 Ton capacity, from its location and removing dirt and dust from interior and exterior of the Air Conditioner and washing the condensor and evaporator with varmi clean solution and other areas by soap solution, spraying pressurised water on condensor and evaportor with proper protection of electrical fixtures and connection, drying by blowing air, and placing in same position complete all as directed.
Taking down unserviceable Rotary/reciprocatory Compressor from Air Conditioner Window Type / Split type 2 Ton capacity of any make & type and Supply and Fixing reconditioned sealed compressor suitable for 2.0 TR window/split type Air conditioner including vacumminishing, initial charging of oil along with new foundation rubber pads, nut and bolts including testing on full load complete all as directed Note: Cost of charging of gas is not included in this item and will be paid under Appropriate item of schedule.
All as per serial item No. 2.00 mentioned here-in-before but for air conditioner of window Type / Split type 1/1.5 Ton capacity
Taking down unserviceable Rotary/reciprocatory Compressor from Air Conditioner Window Type / Split type 2.0 Ton capacity of any make & type and Supply and Fixing new sealed rotary type compressor suitable for 2.0TR window type/split type Air conditioner including vacumminishing, commissioning ,testing and initial charging of oil of air conditioner along with new foundation rubber pads, nut and bolts including testing on full load complete all as directed Note: Cost of charging of gas is not included in this item and will be paid under Appropriate item of schedule.
All as per serial item No. 4.00 above but for air conditioner of window Type / Split type 1/1.5 Ton capacity. Note: Cost of charging of gas is not included in this item and will be paid under Appropriate item of schedule.
All as per serial item No. 4.00 above but for inverter AC of window / Split type of capacity 2.0 ton. Note: Cost of charging of gas is not included in this item and will be paid under Appropriate item of schedule.
All as per serial item No. 4.00 above but for inverter AC of window / Split type of capacity1.5 ton. Note: Cost of charging of gas is not included in this item and will be paid under Appropriate item of schedule.
Supply and Fixing in repair compressor as per existing make suitable for 1.5 TR Chiller including vacumminishing, commissioning ,testing and initial charging of oil complete all as directed including taking down old unserviceable one complete. Note: Cost of charging of gas is not included in this item and will be paid under Appropriate item of schedule.
Supply and fixing in repair compressor 2.5 TR per existing make 3 phase including vacumminishing, commissioning ,testing and initial charging of oil complete all as directed including taking down old unserviceable one complete. Note: Cost of charging of gas is not included in this item and will be paid under Appropriate item of schedule.
Supply & fixing of new strainer including testing including taking down old unserviceable one complete all as specified and directed .
S&F copper capillary tube with filter of appropriate quality and size to match in existing including jointing, brazing and testing suitable for window/split type AC's of 1/1.5/2.0 TR capacity including taking down old unserviceable one complete all as directed.
S&F capacitor of 2.5 to 10 MFD capacity, AC 240 volts and 50 Hz including taking down of old unserviceable capacitor complete all a specified and directed.
S&F capacitor of 25 to 60mfd capacity AC 240 volt and 50 Hz including taking down of old unserviceable capacitor complete all as specified and directed .
M & L for providing new wooden frame of size 50mmx50mm including removing old one and reinstalling existing AC and making electrical connection including all connected items complete all as specified and directedby
S&F in repair ply wood board of 6 mm thick cut into sizes as required at site for AC with and including support for fixing of ply wood and painting with one coats of synthetic enamel paint over a coat of pink primer complete all as directed by Engineer-in-Charge.
Supply and Fixing in replacement old unservicable chassis body of window AC unit made out of MS sheet alongwith new cabinet cover as per same size suitable for 1/1.5/2.0 Ton AC duly spray painted with two coats of synthietic enamel paint (shade of colour as approved by Engineer-in- Charge) ,suitable for installing evaporator coil, condenser coil ,copper wounded fan motor, blower and fan blade and suitable front grill etc, remote sensing unit and wiring complete all as directed
S&F in repair Plastic Front Grill assembly alongwith PVC filter complete suitable for any make of window type 1.5 / 2.0 tone Air Conditioner complete all as directed by Engineer-in-charge.
S&F of Air filter for AC window/split type for 1/1.5/2 TR capacity including taking down old unserviceable one complete all as specified and directed.
S&F in repair Evaporator cooling coil and fins made out of copper tubing at appropriate spacing complete in all respects suitable for Window Type of capacity 1/1.5/2.0 Ton including brazing/welding etc. complete all as directed. Note: (i) Cost of charging of gas is not included in this item and will be paid under Appropriate item of schedule. (ii) Cost of new foundation rubber pads, nut and bolts including testing on full load complete is included in this item
S&F in repair Condensor cooling coil and fins made out of copper tubing at appropriate spacing complete in all respects suitable for Window Type of capacity 1/1.5/2.0 Ton including brazing/welding etc. complete all as directed Note: (i) Cost of charging of gas is not included in this item and will be paid under Appropriate item of schedule. (ii) Cost of new foundation rubber pads, nut and bolts including testing on full load complete is icluded in this item
S & F fan motor double spindle for window AC1/1.5/2 TR with appropriate gauge of super enameled copper conductor to match with the existing design including heat varnishing, overhauling, testing and re-fixing the same after taking down the old unserviceable one complete all as specified and directed.
S&F in repair Fan blower suitable for Window Type Air Conditioner as per existing of capacity 1TR/1.5 Ton / 2.0 Ton complete all as directed.
S&F in repair Fan Blade suitable for Window Type / Split Type Air Conditioner outdoor unit of capacity 1/1.5 Ton / 2.0 Ton complete all as directed.
S & F in repair base tray for window AC made of sheet metal complete all as specified and directed.
S&F of drain pipe with drain cap of window& split type AC 230 volt, single phase for (1/1.5/2.0 TR ) including taking down old unserviceable one complete all as specified and directed.
S&F in repair thermostat used for sensing and temperature control suitable for Window Type/ split type Air Conditioner 1/1.5 Ton / 2.0 Ton complete all as specified and directed
Taking out unserviceable Blower motor from the indoor unit split Type Air Conditioner of any make / type / capacity and supply and fixing new Blower motor of same make / type / capacity including nut and bolts if required complete all as directed by Engr-in-Charge.
Dismantling of unserviceable motor from the Air conditioner of 2.0/1.5/1.0 Tonne capacity and re-winding of fan motor with appropriate gauge of super enameled copper conductor to match with the existing design including heat varnishing, overhauling, testing and re-fixing the same complete all as specified and directed .
S & F fan motor of outdoor unit of Split AC of 1/1.5/2TR capacity with appropriate gauge of super enameled copper conductor to match with the existing design including heat varnishing, overhauling, testing and re-fixing the same after taking down the old unserviceable one complete all as specified and directed.
S&F in repair PCB including Remote Control for remote sensing and operation suitable for Window Type / Split Type Air Conditioner 1.5 Ton / 2.0 Ton make as approved by Engineer-in-charge.
M & L for reparing PCB board of AC 1/1.5/2.0 TR capacity of suitable for window/Split AC including taking down old unserviceable one complete all as specified and directed.
S&F in repair PCB board for inverter type AC 1.5/2.0TR suitable for window / split AC with remote including taking down old UNSV one complete all as specified and directed
S & F sensor of AC 1/1.5/2.0 TR capacity of suitable for window/Split AC including taking down old unserviceable one complete all as specified and directed.
Supply and filling refrigerant gas R-22 for AC complete including testing all as specified and directedby Engr-in-Charge.
Supply and filling refrigerant gas R-32 for AC complete including testing all as specified and directedby Engr-in-Charge.
S & F bush bearing of blower fan motor for window/split type AC, including taking down old unserviceable one complete all as specified and directed .
M&L for flushing out the condensate from gas system by creating vacuum, leakage testing of the system, injecting CTC solution for demoistureing the system and gas charging by R-22/R-134/R-32/R-410/R-600 upto the required pressure for 1.5 / 2.0 Ton Window Type / Split Type Air Conditioner complete all as specified and directed by Engineer-in-charge. Note :- (i)The cost of gas is included in this item and nothing extra shall be paid on this account. (ii) The cost of capillary/drier/flare nut if required is included in this item item and nothing will be paid extra on this account
S & F in repair inner unit bracket / wall stand of inner unit of split type AC of capacity 1/1.5/2 TR including taking down old unserviceable ones complete all as specified and directed.
S&F in repair Evaporator cooling coil and fins made out of copper tubing at appropriate spacing complete in all respects suitable for indoor unit of split Type of capacity 1.5/2.0 Ton including brazing/welding etc. complete all as directed. Note: (i) Cost of charging of gas is not included in this item and will be paid under Appropriate item of schedule. (ii) Cost of new foundation rubber pads, nut and bolts including testing on full load complete is included in this item
S & F in repair blower/runner of Inner unit including bush of AC of capacity 1/1.5/2 TR including taking down old unserviceable ones complete all as specified and directed. complete all as specified and directed.
M & L for PVC copper cable for min. 2.5 sqmm 3 core core for connecting the indoor and outdoor unit of split type ACs complete all as specifed and directed.
M & L for PVC copper cable for min. 2.5 sqmm 4 core for connecting the indoor and outdoor unit of split type ACs complete all as specifed and directed.
S&F in replacement of blower fan by taking down of the outer unit of split AC of capacity 1/1.5 TR testing complete all as specified and directed by Engr-in-charge .
S&F in repair Condensor cooling coil and fins made out of copper tubing at appropriate spacing complete in all respects suitable for split Type of capacity 1.5/2.0 Ton including brazing/welding etc. complete all as directed Note: (i) Cost of charging of gas is not included in this item and will be paid under Appropriate item of schedule. (ii) Cost of new foundation rubber pads, nut and bolts including testing on full load complete is icluded in this item
S & F in repairs flare nut with dead cap suitable suitable for split Type of capacity 1.5/2.0 Ton complete all as directed
S & F in Replacement of valves of size 1/2", 1/4", 3/8",5/8" for split Type of capacity 1.5/2.0 Ton complete all as directed
S&F in repair Copper pipe with insulation 1/2" dia, superior quality suitable for refrigeration of split ACs, drawn through/fixed to walls or roof complete all as directed
S&F in repair Copper pipe with insulation 3/8"" dia, superior quality suitable for refrigeration of split ACs, drawn through/fixed to walls or roof complete all as directed
S&F in repair Copper pipe with insulation 5/8"" dia, superior quality suitable for refrigeration of split ACs, drawn through/fixed to walls or roof complete all as directed
S&F in repair Copper pipe with insulation 1/4" dia, superior quality suitable for refrigeration of split ACs, drawn through/fixed to walls or roof complete all as directed
Supply of remote control unit of window/split AC as per original make of AC or compatibility of ACs.
Supply of universal remote control unit of window/split AC as per original make of AC or compatibility of ACs.
S &F MS Bracket heavy duty for outdoor unit of AC including taking down old unserviceable one and necesarry PCC work for bldg upto G+4 complete all as specified and directed.
S&F of contactor assembly for 2.0 /1.5/1TR split type AC single phase 230 volt condensing unit of any make including taking down old unserviceable one complete all as specified and directedby Engr-in-Charge.
Taking out unserviceable unit and Supply and install window AC unit complete of capacity 1.5 TR with 3 star rating and connection complete including drain pipe complete all as directed. Make - Voltas/LG/Hitachi or equivalent
Taking out unserviceable indoor unit and supply and install indoor unit of split AC unit complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality of capacity 1.5 TR with 3 star rating ,connecting pipe with complete insulation and coooneting with outdoor unit complete all as specified and directed. Make - Voltas/LG/Hitachi or equivalent
Taking out unserviceable outdoor unit and supply and install outdoor unit of split AC unit complete of capacity 1.5 TR with 3 star rating and connecting pipe with complete insulation. Make - Voltas/LG/Hitachi or equivalent .
Taking out unserviceable refrigerator and supply and install refrigerator min 184L min 2 star single door complete all as specified and directed. Make - LG/Samsung or equivalent
Taking out of existing unserviceable compressor sealed unit from refrigerator of 165/190L and Repairing of compressor servicing, flashing refixing the after leakage testing, vaccummision the system gas charging complete all as specified and directed by Engr-in-Charge. Note: Refrigerant measured separately
Taking out of unserviceable compressor sealed unit from refrigerator of capacity 286/300/320 ltrs or deepfreezer 400L and Repairing of compressor servicing, flashing refixing the repaired compressor after leakage testing, vaccummision the system gas charging complete all as specified and directed. Note: Cost of charging of gas is not included in this item and will be paid under Appropriate item of schedule.
S&F of new compressor of capacity 286/300/320 ltrs for refrigerator or deepfreezer 400L after testing complete all as specified and directed including taking down old unserviceable one complete. Note: Cost of charging of gas is not included in this item and will be paid under Appropriate item of schedule.
S&F of new compressor of capacity 165/190 ltrs for refrigerator after testing complete all as specified and directed including taking down old unserviceable one complete. Note: Cost of charging of gas is not included in this item and will be paid under Appropriate item of schedule.
S&F of new compressor of capacity inverter refrigerator upto 320L after testing complete all as specified and directed including taking down old unserviceable one complete. Note: Cost of charging of gas is not included in this item and will be paid under Appropriate item of schedule.
S&F in repair Starting Relay Assembly with Over Load Protector any model complete all as directed.
Taking out of unserviceable thermostat switch & supply and fixing of thermostat for refrigerator of 165 to 310 Lts capacity complete all as specified and directed by Engr-in-Charge.
Taking out of unserviceable lamp holder including lamp case and S & F of new pigmy lamp holder and lamp case to match with the existing, suitable for refrigerators of any capacity complete all as specified and directed by Engr-in-Charge.
Supply only Refrigerant - (R-134A) complete all as specified and directed by Engr-in-Charge.
Taking out of old unserviceable strainer of refrigerators of any capacity including supplying and fixing of new strainer of approved quality to match with the existing complete all as specified and directed by Engr-in-Charge.
Taking out of old unserviceable door lock of refrigerator of any capacity & Supply and fixing of new door lock to match with the existing size complete all as specified and directed.
Taking out unserviceable cooling coil and Supply and Fixing cooling coil with condenser assembly for refrigerator of any capacity as per existing samples complete all as specified and directed.
S&F Adjustable shelves for refrigerator of any capacity as per existing samples complete all as specified and directed by Engr-in-Charge.
S&F Bottle retainer/shelves for refrigerator of any capacity as per existing samples including taking down old unserviceable one complete all as specified and directed.
S&F door handle for refrigerator of any capacity as per existing samples including taking down old unserviceable one complete all as specified and directed.
S&F freezer door as per sample including taking down old unserviceable one complete all as specified and directed.
S&F chill tray of any type/ capacity/ make as per sample including taking down old unserviceable one complete all as specified and directed.
S&F vegetable tray of any type/ capacity/ make as per sample including taking down old unserviceable one complete all as specified and directed.
S&F ICE tray of any type/ capacity/ make as per sample including taking down old unserviceable one complete all as specified and directed.
S&F Capillary tube size with filter to any type of refrigerators complete all as specified and directed by Engr-in-Charge. .
S & F heater of refrigerator upto capacity 320 ltr complete all as specified and directed by Engr-in-Charge. .
S & F magnetic gasket of refrigerator door complete all as specified and directed by Engr-in-Charge. .
S & F timer for defrost of refrigerator complete all as specified and directed by Engr-in-Charge. .
S & F condenser coil of refrigerator capacity 320 ltr complete all as specified and directed by Engr-in-Charge. .
Dismantling of worn out outer body of refrigerator and repairing by replacement to worn out portion of the body by welding/fabricating with approved quality and MS Sheet/PVC sheet to match with the existing shape including, refixing of all the dismantled enclosures of the refrigerator in position including testing, painting and commissioning complete all as specified and directed .
Taking out Water cooler upto 150L/150L capacity from the existing place for repairing of compressor, servicing, and refixing the repaired compressor, leakage testing, vaccummision the system gas charging completely complete all as specified and directed. Note: Refrigerant measured separately.
S&F Bush of fan motor for water cooler of capacity upto 150/150L including taking down old unserviceable one complete all as specified and directed.
Taking out unserviceable relay from water cooler of capacity upto 150/150L Ltrs capacity (for 1/3 HP compressor) and S&F of new relay to match with the existing complete all as specified and directed.
Taking out of unserviceable thermostat switch & S/F of new thermostat switch to the water cooler of any capacity complete all as specified and directed.
S & F copper capillary tube for water coolers including taking out of old unserviceable tubes complete all as specified and directed.
Dismantling of worn out outer body of water cooler and repairing by replacement to worn out portion of the sheet metal body by welding/fabricating with approved quality and MS Sheet to match with the existing shape including, refixing of all the dismantled enclosures of the water cooler in position including testing, painting and commissioning complete all as specified and directed.
Taking out of existing worn out and perished rubber gasket of water cooler tank cover and S & F of new gasket as per existing sample for any capacity of water cooler complete all as specified and directed.
Taking out of existing worn out and unserviceable water faucets of any type 15 mm bore and S & F of cast copper alloy chromium plated push type / lift tap water faucets of 15mm bore complete all as specified and directed.
Taking out of existing worn out and unserviceable float valve 15mm bore of any type and S & F of ball valve of 15mm dia including inlet nipple and connecting unions etc complete all as specified and directed.
Taking out of worn out drain pipe including drain tray and repair the same and drain pipes to match with the existing for any capacity of water coolers complete all as specified and directed.
Taking out of old unserviceable top cover lock of water cooler of any capacity and S&F of new top cover lock to match with the existing complete all as specified and directed.
Servicing and maintenance of Bry- Air Dehumidifier, Bed drive system, Model FLi - 2000 including electrical panel, ducts, filter properly complete all as specified and directed. Note: Spares as required will be measured and paid separately.
Supply and fix Display card . 12 v.FLI / FLP / FLC (J) parts for Bry Air De-humidifier Model FLI- 2000 complete all as specified and directed
Supply and fix Filter. 340x370x50 mm for Bry Air De-humidifier Model FLI- 2000 complete all as specified and directed
Supply and fix Filter.610x610x50 mm for Bry Air De-humidifier Model FLI- 2000 complete all as specified and directed
Supply and fix Hinge. Zinc Die Cast . CD - 38X34 for Bry Air De-humidifier Model FLI- 2000 complete all as specified and directed
Supply and fix Latch. T -Type Comp. CD- 33MM for Bry Air De-humidifier Model FLI- 2000 complete all as specified and directed
Supply and fix Sensor RTD 4X150mm 3.5m LPT 100 for Bry Air De-humidifier Model FLI- 2000 complete all as specified and directed
Supply and fix Thermostat Panel Mount (Non-UL) for Bry Air De-humidifier Model FLI- 2000 complete all as specified and directed
Supply and fix Sprkt Driver 12T 1/2" P 12mm for Bry Air De-humidifier Model FLI- 2000 complete all as specified and directed
Supply and fix Heater Tube Type, 4kw, FL- 2000, 230 for Bry Air De-humidifier Model FLI- 2000 complete all as specified and directed
Supply and fix Gear box for Bry Air De-humidifier Model FLI- 2000 complete all as specified and directed
Supply and fix in repair Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 130 V to 295 V with output voltage stabilized at 230 V with accuracy of ± 2.5% LED Display wall mounted and of capacity 1 KVA complete all as specified and directed Note- Old US Voltage stablizer to be deposited to MES store.
S&F in repair Sub main wiring with two single core cable PVC insulated unsheathed of copper multi stranded conductor FRLS cable of size 4 sqmm, 1100 votls grade drawing through and including conduit 25 mm dia medium duty including acessories such as Tee, bend, Elbow etc, ISI marked with and including PVC insulated 4 sqmm unsheathed multistranded FRLS copper conductor cable for earth continuity and connected to common earth dolly etc complete all as specified and directed by Engineer-in-charge including taking down old unserviceable submain wiring. Note:- (i)Three length of 4 Sqmm cable and one length of PVC conduit will be measured as one length.
S&F A C starter unit consisting of one 25 Amp capacity starter, one 240 V 25 Amps 10 KA SPN MCB, one 25 Amps socket and one 25 Amps plug top prewired and 6M modular box, frame and cover plate including taking town of old unserviceable one of complete all as specified and directed
Taking down unserviceable ceiling fans and supplying and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete with all the connection as directed.
Taking down unserviceable wall fans and supply and fixing wall fans 400mm sweep power input 60Watts min speed 1350RPM min air delivery 85 CMM 240V 50Hz complete with electrical connection including making good to disturbed wall surface as per existing finish complete all as specified and directed including taking down old unserviceable one complete all as specified and directed.
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300mm including making good to disturbed wall surface as per existing finish complete all as specified and directed including taking down old unserviceable one complete all as specified and directed.
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm including including making good to disturbed wall surface as per existing finish complete all as specified and directed including taking down old unserviceable one complete all as specified and directed.
Supply and fix exhaust fan made of steel complete blade fan motor with louvers , voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300mm including making good to disturbed wall surface as per existing finish complete all as specified and directed including taking down old unserviceable one complete all as specified and directed.
S&F 5 star rated water heater (geyser) storage type plastic body with MS inner tank with glass line coating and heating element upto 2KW, capacity 25 ltrs energy effieceint, BEE 5 star rated with complete with stainless steel threaded geyser connection pipe length not less than 60cm including washers for incoming & outgoing hot & cold water connections as specified and directed including connecting upwater heater/geyser including required hold fast 10 cm long with washers and accessories , complete all as specified and as directed.
Dis-assembling carefully ceiling fans (any make) of 1200/1400mm sweep, cutting & removing old copper winding wire and rewinding the same with new super enameled copper wire of suitable size / gauge including providing insulation by varnishing, oiling and greasing, replacing bearing and gun metal shaft required and reassembling back including testing complete. Note :- (i) Cost of bearings provided shall be measured in this item and nothing will be paid extra on this account. (ii) Working space if required, will be provided to the contractor for carrying out necessary rewinding/repair with in AGE E/M store yard premises (iii) If winded fan found unserviceable within six month of rewinding,contractor will repair the same without any extra cost. (iv)Cost of Machining work in body of ceiling fan by taking out worn out bearing, boring hole to accommodate ball bearings is included in this item and nothing shall be paid extra on this account. (v) Cost of carrying ceiling fan from site to the workshop and refixing of the same after repair is included in this item and all T&P and vehicle cost will be born by the contractor in this regard (vi) Cost of shaft will be paid under appropriate item of Schedule.
Dis-assembling of exhaust fan of size 250mm/ 300mm/400mm AC 230 Volts, 50 Hz 900/1400 RPM for repair, removing existing burnt winding wire, bearing/bushes, flexible wire, shaft, check nuts, frame and rewinding with super enameled copper windings wire of suitable size / gauge and replacement of bushes, bearings, shafts, check nuts, bolts and washers, greasing, varnishing and reassembling back including testing complete. Note :- (i) Cost of bushes/bearings, provided shall be measured and paid in this item and nothing extra shall be paid on this account. (ii) Working space if required,will be provided to the contractor for carrying out necessary rewinding/repair with in AGE E/M store yard premises. (iii) If winded exhaust fan found unserviceable within six month of rewinding,contractor will repair the same without any extra cost. (iv)Cost of Machining work in body of exhaust fan by taking out worn out bush, boring hole to accommodate ball bearings is included in this item and nothing shall be paid extra on this account. (v) Cost of carrying exhaust fan from site to the workshop and refixing of the same after repair is included in this item and all T&P and vehicle cost will be born by the contractor in this regard. (vi) Cost of shaft will be paid under appropriate item of Schedule.
Supply only capacitor 2.5 mfd to 3.15 mfd dry type for Ceiling fan complete all as specified and directed.
Supply only capacitor 4 mfd to 6 mfd dry type for exhaust fan complete all as specified and directed.
M&L for Preparation of old painted surfaces of the body, blades, down rod etc of ceiling fans of size 1200/1400mm sweep (any make) complete by rubbing with amery paper and filing in cavities with approved filler and applying one coat of spray painting with synthetic enamel paint (Glossy white/ pale cream) on the body, blades, down rods and writing MES /Fan no with black synthetic enamel paint complete all as specified & directed.
M&L for Preparation of old painted surfaces of the body and blades, of exhaust fans of size 250/300mm sweep (any make) complete by rubbing with amery paper and filing in cavities with approved filler and applying one coat of spray painting with synthetic enamel paint (Glossy white/ pale cream) on the body, blades, down rods and writing MES /Exhaust no with black synthetic enamel paint complete all as specified & directed.
Supply only rubber bush complete with spring, nut bolt, fork hook and spilt pin, washer suitable for existing ceiling fan 1200mm/1400mm sweep complete all as specified and directed.
Supply and fix in replacement Ceiling fan stator 48 inch sweep 12 mm copper winding including ,thick steel bolt with double nuts and locking pins and high quality rubber bushing to reduce vibration complete all as specified and directed.
Supply and fix in replacement rotor complete suitable for 48 inch sweep ceiling fan all as specified and directed.
Supply & Fix in repair ceiling fan mild steel body set (upper & lower) with two set of bearings for ceiling fans of sweep 1200mm duly painted and any make and fixing in position complete all as specified and directed.
Supply only PVC canopy set (upper & lower) for ceiling fans with of size 1200mm to 1400 mm sweep and any make and fixing in position complete.
Supply only of aluminium blades with fan blade screws of ceiling fan for any sweep( 1200mm to 1400 mm) & make complete.
Supply and fix MS heavy duty down rod of 15mm dia and min 8m length duly painted with white colour to produce glossy finish with necessary cutting / drilling holes and PVC connector including taking down of old unserviceable one along with taking down and fixing of ceiling fan complete all as specified and directed.
S&F MS heavy duty down rod of 15mm dia & min 600mm length duly painted with white colour to produce glossy finish with necessary cutting / drilling holes and PVC connector including taking down of old unsv one alongwith taking down and fixing of ceiling fan complete all as specified and directed
Supply and fix in replacement PVC flexible 2 core cable with copper con-ductor of size 23/0.76 mm from ceiling rose to ceiling fan including taking down of old unserviceable one complete all as specified and directed.
Supply and fix in repair PVC Cable of size 2.5 sqmm 3 core copper conductor round type. All as specified and directed by Enge in charge.
M&L for brazing/gas welding of inner container copper of 25 ltrs /50 ltrs capacity and any make and making leak proof including taking down and refixing the geysers complete all as directed.
S & F heating element 2KW as per existing make of geyser complete including taking down of old unserviceable one complete all as specified and directed by Engr-in-charge.
S & F Thermostate for suitable existing geyser of 25/50 litrs capacity complete including taking down of old unserviceable one complete all as specified and directed by Engr-in-charge.
S & F stainless steel threaded geyser connection pipe of length not less than 60cm including washers for incoming & outgoing hot & cold water connections as specified and directed by Engr-in-charge
S & F Apparatus plate assembly complete for geyser of capacity 25/50 litrs capacity complete including taking down of old unserviceable one complete all as specified and directed by Engr-in-charge.
S & F Outer casing made out of MS sheet suitable for geyser of capacity 25 litrs complete including taking down of old unserviceable one complete all as specified and directed by Engr-in-charge.
S & F Storage tank fabricated from MS sheet gauge suitable for geyser of capacity 25 ltrs of make as specified and approved complete including taking down of old unserviceable one complete all as specified and directed by Engr-in-charge.
S & F Split plate bottom cover made suitable for 25 litrs capacity geyser complete including taking down of old unserviceable one complete all as specified and directed by Engr-in-charge.
S & F top cover complete including taking down of old unserviceable one complete all as specified and directed by Engr-in-charge.
S & F insulating material glass wool complete including taking down of old unserviceable one complete all as specified and directed by Engr-in-charge.
S & F Element holding brass stud complete including taking down of old unserviceable one complete all as specified and directed by Engr-in-charge.
S & F clamp with anchor fastener bolt complete including taking down of old unserviceable one and taking down and refixing the geyser complete all as specified and directed by Engr-in-charge.
S & F Fusible metal plug complete including taking down of old unserviceable one complete all as specified and directed by Engr-in-charge.
S & F Neon lamp round/square with connection lead complete including taking down of old unserviceable one complete all as specified and directed by Engr-in-charge.
S & F Non return valve for geyser inlet complete including taking down of old unserviceable one complete all as specified and directed by Engr-in-charge.
Supply and fix in replacement of louvers iron with shutters suitable for existing exhaust fan of any size and shape at site upto bldg of G+4 storey complete all as specified and directed by Engg-in-charge
Supply and fixing in repair LED lights fitting 1x 20W, 220V,AC wall mounted LED batten with polycarbonate extruded polycarbonate housing & integrated electronic driver with efficacy of 100lumen/W connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engr-in-Charge. .
Supply and fixing in repair LED lights fitting 1x 10W, 220V,AC wall mounted LED batten with polycarbonate extruded polycarbonate housing & integrated electronic driver with efficacy of 100lumen/W connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engr-in-Charge. .
KWALITY CONSTRUCTION (BID ID -3489032)
EASTERN REFRIGERATION AND ELECTRICAL CO (BID ID -3492030)
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.39 MB
TENDER8872.pdf
Tender Documents • 1.41 MB
BOQ_828764.xls
BOQ • 0.39 MB
Download all tender documents and submit your bid