| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.8 LAccepted-AOC | ₹28.8 L Quoted ₹28.9 L | L1 | Accepted-AOC L1 |
| 2 | L2₹31.8 L+₹3.0 L (10.2%)Rejected-AOC | ₹31.8 L+₹3.0 L (10.2%) | L2 | Rejected-AOC L2 |
| 3 | L3₹33.5 L+₹4.6 L (16.0%)Rejected-AOC KTA ROAD LAMBA LINE JUNGLIGHAT PO PORT BLAIR 744103 | PORT BLAIR | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | ₹33.5 L+₹4.6 L (16.0%) | L3 | Rejected-AOC L3 |
| 4 | L4₹38.1 L+₹9.3 L (32.1%)Rejected-AOC | ₹38.1 L+₹9.3 L (32.1%) | L4 | Rejected-AOC L4 |
| 5 | L5₹56.4 L+₹27.5 L (95.3%)Rejected-AOC | ₹56.4 L+₹27.5 L (95.3%) | L5 | Rejected-AOC L5 |
Tender Value
₹27.5 L
EMD Value
₹55,000
Closing Date
10 Jun 2020, 6:00 pmClosed
GE (I) Campbell Bay
Garrison Engineer (I), Military Engineer Services, Army Land, Great Nicobar Islands, Campbell Bay, Pin 744 302.
PROVISION OF CERTAIN E/M WORKS IN CGDHQ-10 UNDER GE (I) CAMPBELL BAY.
2020_MES_345597_1
8672/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Campbell Bay
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (I) Campbell Bay
₹55,000
Yes
29 Jun 2020
26 May 2020
12 Jun 2020
26 May 2020
10 Jun 2020
28 May 2020
Amount
Supply & Install Hybrid Solar LED Street Light 40Watt LED Efficacy 144 lumen/watt @350mA , 5000 lumen, System Efficacy of Luminaire >100lumens/watt High power LED Driver efficiency > ~ 92% aluminum Housing IP-65 Charge Controller MPPT+ HYBRID Optimized for Lithium battery chemistry Rating 12.75V,5 Amps Efficiency > ~ 95% Motion sensor based lighting control stage high efficiency charging algorithm Stringent battery charging set points optimized High efficiency DC-DC drive >92% Soft start LED driver Hot plugging electronic protection for LED Fused short circuit protection for LED Electronic no load shutdown Battery overcharge and deep discharge protection Reverse current flow back protection Optional timer based LED dimming Complete system information by status indication Automatic operation control from dusk to dawn Electronics encapsulated/coated prevents moisture based degradation Unique auto power save mode in case of low battery state of charge in bad weather conditions with indicator.
Motion sensor indication during normal operation All aluminum alloy construction Light output region protected by tough clear cover BIS approved premium Li-ion cells used in the battery IP 65 protection Charging, low battery and other indications externally visible in systemIEC 62093 - balance of system components for solar photo voltaic systems - design qualification natural environments IEC 61347-2-13 - led driver safety IEC 62384 - led driver performance IEC 62509 - solar charge controllers performance and functioning IEC 62124 - stand alone systems design verification IEC61000-4-2 electrostatic discharge IEC61000-4-3 radio frequency field IEC 61547- EMC immunity CISPR 15 conducted emissions Large cross section wire acceptance with ease Inbuilt sensor with Detection distance >10 Meters Detection range Horizontal X Vertical-102°X92° Solar Panel Capacity 100Wp Solar cells Crystalline silicon MNRE approved make. Battery Capacity 44.2V(fully charged),13Ah, Lithium-ion. Make - CROMPTON Cat Part No CSADSPI40CDL or Equivalent in CG/Phillips/GE Note: Price including earth cutting, Digging, RCC foundation works for pole using cement concrete for the entire completion of Job all as specified and as directed by Engineer-in-charge.
Supply and install SP-22 type 410 (9.0 Mtr Long) Steel tubular swaged poles complete with cast iron base plate, final taper plug, bolts, nuts and screws as specified with and including material and labour for making Excavation and PCC (1:4:8) type C2 (using 40 mm graded stone aggregate) for foundation and PCC (1:2:4) type C1 (using 20 mm graded stone aggregate) for coping, Returning Filling, removal including painting of poles with two coats of aluminum paint over one coat of priming and numbering of poles etc, entire completion all as specified and directed.
Supply fixing 90Watt LED street light with pressure die cast aluminum housing & toughened glass with IP-66 degree of protection, Individual LED's must have peanut lenses for better throw across & along the road ,with luminaire efficiency of greater than 85 Lumen/Watt (Minimum lumen output of luminaire should be 3800Lumens ), color rendering (CRI) of ≥ 75 and co-related colour temperature (CCT ) of 5700K (± 500K) , The luminaire should have 5KV surge protection, PF ≥ 0.95, and total harmonic distortion of THD ≤ 10% , voltage range of 140-280V should be provided. Luminaire should have top maintainable driver compartment for easy access to driver during maintenance. The Driver used must be a constant current driver with efficiency of ≥ 85%. The manufacturers LOGO must be Embossed/ Engraved in the housing of the luminaire including bracket for street light fittings made out of 40 mm dia GI pipe of light grade 1.5 m long each bent to shape & size required & fixed to pole with and including flat iron clamps 02 Nos made out of 40 x 5 mm flat iron including GI Nuts, bolts and washers and painting with two coats of aluminum paint over one coat of priming of clamps ,entire completion all as specified and directed. Make : CG LSTP-90-CDL-M or equivalent in Wipro/ Philips.
Supply laying and testing of XLPE cable of size 10.0 sq mm 2 core, Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor complete all as specified and directed.
Excavation in trenches in hard/dense soil not exceeding 1.5 meter wide and not exceeding 1.5M in depth for laying of cables and getting out of excavated material complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick each, excavated soil in trenches after the pipes have been laid and tested complete all as specified and directed.
Removing excavated soil to a distance not exceeding 50 meter and depositing where directed at a level not exceeding 1.50 meter above the starting point complete all as specified and directed.
Supply & Fix HDPE double wall corrugated pipes conforming to IS-14930 Part-II with IP Protection of IP-67 having outer dia 50 mm and inner dia of 38 mm with necessary couplers, bends etc for protection of LT cable all as specified and directed.
Supply and fix thermoplastic cable junction boxes IP 55/IP 65 with metric knockout for cable entry with terminal of size 200x160x98 mm on pole with MS clamps, nut bolts, washers and glands suitable for 16 sq mm 04 core cable complete all as specified and directed . Make Hansel Cat No K 9255 or Equivalent in Similar Make.
Supply and fix 2 core 1.5 sqmm PVC insulated PVC sheathed weather proof multistranded copper conductor cable 1100 volts grade drawn through in GI conduit, pole etc with MS clamps from junction box to street light fitting all as specified and directed. Note- GI tube shall be measured and paid separately
Supply and fix 15 mm dia GI tubes light grade with all fitting from looping box to street light fittings with clamps, nuts & bolts complete all as specified and as directed
Supply and fixing 1.5 TR 5 Star rated split air conditioning units indoor and outdoor complete with 100% copper condenser inverter model of BEE 2018 rating, cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality complete all as specified and directed. Make: Voltas, Blue Star, Samsung.
Supply and fix SPN enclosure with a two pole and earth plug and socket complete with one single MCB of rating 20 Amps, 240 Volts complete all as specified and directed. Make: Havells /Standard/Bajaj/L&T/GEC/Indo Asian.
Material & Labour for submain wiring alongwith earth wire with 2 x 4.0 Sqmm + 1 x 4 Sqmm FRLS PVC insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core, drawn through and including PVC Casing and Caping and its all accessories of suitable size on wall/roof surfaces complete all as specified and directed by Engineer-in-Charge. Note: Two runs of 4.0 Sqmm, one run of 4 Sqmm copper cable and one run of PVC Casing and Caping shall be measured as one unit length.
bansal construction
kakolil trade agencies
M/S RAJBUILDERS
M/s Pintu Furniture
M/s Kamal Electrical
M/s Bismi Builders & Enterprises
S K ENTERPRISES
RS ENGINEERING WORK
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .