HQ CWE (AF) Gurgaon, Old Palam Road, Delhi Cantt-10
PROVN OF FIRE HYDRANTS AND AUTOMATED FIRE ALARM SYSTEM IN TECH AREA AT MCC AF STN BASANT NAGAR UNDER GE (AF) FARIDABAD
2023_MES_632994_4
CWE/GGN/FT-23/2023-24
Open Tender
Electrical and Maintenance Works
Lump-sum
180 days
AF Stn Basant Nagar
As per NIT
8 documents required · 8 mandatory
₹500
GE AF Faridabad
₹89,280
Yes
25 Jun 2024
12 Apr 2024
8 May 2024
12 Apr 2024
6 May 2024
20 Apr 2024
12 Apr 2024 - 19 Apr 2024
Amount
Sch 'A' Section I to III under Srl No. 2.0 to 4.0 These schedules are pre-priced by MES. Details of section I to III are given in Tender Documents
Lump sum price worked out by the contractor for 'Building Works' as listed in Sch 'A' Section-I (refer prepriced shedule attached seperately)
Lump sum price worked out by the contractor for SITE CLEARANCE as listed in Sch 'A' Section-II (refer prepriced shedule attached seperately)
Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY FOR FIRE HYDRANT as listed in Sch 'A' Section-III (refer prepriced shedule attached seperately)
MISCELLANEOUS ITEMS under Sch 'A' Section-IV are not prepriced by MES and item Rate to be quoted by contractor for each item.
Supply and fix MS cabinet (approx 750mm x 600mm x 450mm) to encl fire brigade inlet connections fabricated from 16 gauge sheet with full front glass door and locking arrangement painted and mounted on masonry platform complete all as specified and directed
Supply, installing testing and commissioning of factory made and tested (Including CPRI test cetified) indoor type floor mounted LT panel board, cubical type suitable for 415 Volts 3 phase, 4 wire 50Hz, Ac supply system having busbar chember with insulated AL busbar of rating 300 A for phase installed on porcelin/ SMC insulators. The panel shall be dust and vermin proof IP-54 class protection and made out of 2.00 mm thick CRCA MS sheet and angle iron frame 40x 40x 6mm thick frame work, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coat of red oxide primer, front and back opening type with aproaches for cable entry with double door shutter and locking arrangements including internal wiring with PVC insulated stranded copper conductor cable FRLS confirming to IS:694, sheathed 1100V grade of appropriate size The panel shall be comprising of following:-
Supplying, installation, testing & commissioning of 1, 2, 4 and 8 loop Analogue Addressable Fire Alarm Control Panel expandable via plug-in loop driver boards, loop current minimum 500mA per loop, dual flash based microprocessor, supports to connect minimum 120 detectors and devices in any combination in each loop via fully digital communication protocol, equipped with a white backlit display ( 240x64 ) graphical LCD Display with at least 6 lines of information, 200 zones (soft zones) per panel and 2000 zones on network, fully programmable via alphanumeric keypad or configuration software without using any king of DONGLE/LICENCE OR SPECIAL CABLE, dedicated USB and RS-232 serial port for direct or PC connection. panel support 5000 historic events and 500 fire alarm events. Panel shall be equipped with in-built multi-meter for live monitoring of loop current, earth voltage, loop voltage etc. Panel shall support peer to peer networking between panels capable of networking 32 nodes on standard networking and 200 nodes on secured network.Panel housing shall meets min IP30 ingress protection classification finished in RAL 7035. The panel shall be capable of providing output for BMS/ SCADA software through optional Modbus/ Bacnet module. Independently certified as complying with requirements of BS EN 54 Part 2, 4 and 13/. 1 Loop Panel with Network card
Supplying, installation, testing & commissioning of repeater panel with 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required. Complete all as specified and directed.
Supplying, installation, testing & commissioning of Intelligent Analogue Multisensor (combination of smoke and heat including both ROR & fixed) Detector with base and inbuilt Isolator/ Isolator Module and special algorithms to utilize information from both smoke and heat sensing elements to ensure high level of immunity to false alarms without compromising genuine alarm sensing performance. Programmable multiple smoke sensitivity level and 5 modes of operation, the detector shall be capable of operating in heat only mode. Bi-directional in-built short circuit isolator to protect against cable faults, dual bi-colour LED's with 360 degree view of status, auto- addressable/electronically, Independently certified as complying with requirements of BS EN 54 Part 5, 7 and 17.
Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required. Complete all as specified and directed.
Supplying, installation, testing & commissioning of Intelligent Analogue addressable resettable Manual Call Point , with in-built bi-directional short circuit isolator. Bi-Colour LED for local indication of device status, single action operation, reset to normal condition using special reset key. Independently certified as complying with r quirements of BS EN 54 Part 11 and 17. Complete all as specified and directed.
Supplying, installation, testing & commissioning of Intelligent Analogue Single Input/ Monitor Module with inbuilt Isolator/ Isolator Module , microprocessor controlled interface modul for Flow switch monitoring and other input purposes , with in-built short circuit isolator, 360 degree view LED's for local indication of device status, auto-addressable. Independently certified as complying with r quirements of BS EN 54 Part 18 and 17. Complete all as specified and directed.
Supplying, installation, testing & commissioning of Intelligent Analogue Relay Output/ Control Module with inbuilt Isolator/ Isolator Module , for control of third party/auxiliary devices using single volt-free change-over relay contact, with in-built short circuit isolator, Bi-colour LED's for local indication of device status, auto-addressable. Independently certified as complying with requirements of BS EN 54 Part 18 and 17. Complete all as specified and directed.
Supplying and Laying of 2X1.5 sqmm fire survival armoured cable.Complete all as specified and directed.
Supplying and Laying of 32mm HDPE pipe, ISI marked. Complete all as specified and directed.
RAVINDRA BROTHERS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .