| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.0 LAccepted-AOC AT PO CHANDIPUR BALASORE 756025 | BALASORE | BALASORE | ODISHA | 756025 | L1 | Accepted-AOC Being lowest and reasonable | |
| 2 | L2₹16.3 L+₹1.1 L (6.94%)Rejected-Finance BANK COLONY MATHASAHI PS TOWN PO DIST BALASORE | BALASORE | BALASORE | ODISHA | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹16.8 L+₹1.5 L (9.95%)Rejected-Finance | L3 | Rejected-Finance Not being lowest | |
| 4 | L4₹16.9 L+₹1.6 L (10.4%)Rejected-Finance | L4 | Rejected-Finance Not being lowest | |
| 5 | L5₹16.9 L+₹1.6 L (10.4%)Rejected-Finance JANUGANJ REMUNA GOLAI BALASORE 756 019 ODISHA | BALESHWAR | ODISHA | 756019 | L5 | Rejected-Finance Not being lowest |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
3 Jan 2022, 6:00 pmClosed
GE I R and D Chandipur
GE I R and D Chandipur, Post- Chandipur, PIN-756025
REPAIR MAINTENANCE OF PACKAGE CENTRAL AIR CONDITIONING PLANTS AND CONNECTED WORKS AT TECH AND DOMESTIC AREA AT PXE CHANDIPUR
2021_MES_494339_1
8686/CDP
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Chandipur
As per tender documents
9 documents required · 9 mandatory
₹500
GE I R and D Chandipur
₹30,000
Yes
31 Jan 2022
13 Dec 2021
5 Jan 2022
13 Dec 2021
3 Jan 2022
28 Dec 2021
Amount
NOTE (Applicable for all items) :- The bidders/contractors are advised to read tender document & all corrigendum / amendments and General conditions of contracts before entrying/quoting the rates.
M & L for dismantling and taking out unserviceable and defective parts of compressor of chiller Units of Central type AC Plants of capacity 40 TR of any make,and model after disconnecting the discharge & suction line removal of necessary electrical connection etc. Dismantling compressor body complete and carry out the repair work as per the following :- (a) Repairs to crank shaft, connecting rod, piston, piston pin valve plate by remetaling, cutting/grinding and polishing as required and by supply and replacing all spare parts with new one as required and directed. (b) Repairs /fixing by replacing of all new discharge and suction reeds, big end and small end bush, all bearing, all piston rings, capillary drier cum filter with new one all as specified and directed . (c) Repairs/fixing by replacing of all new kinds of gasket, washers, scappring made of Nylon/ Tuflon sheet/ rubber/fibre sheet as required with new one and all as directed. (d) Repair of Oil pump kit by , dismantling and cleaning, greasing oiling along with new gasket all as required and directed. (e) M & L for Repair/replacement of old u/s copper pipe line as per existing size and shape when found leaking/damage at the time of leak check including necessary flairing, brazing as required and replacement of end fittings made of copper including brass flange nuts, brass dead cap and brass pipe as per site requirement and as directed.( Note : - The cost of new Copper pipe is also included in the same job ) (f) Supply and fix in repair of all u/s rusted bolts, nuts and washers of any kind/made of any metalical/any size and shape as per site requirement with new one all specified and directed. (Note :- The cost of all types/sizes of new nuts , bolts and washers are included in the same job. (g) After the repair work re-assembling the plant and check for leak in system with the help of Nitrogen gas. in case of any leak is detected the repair is to be carried out without any extra cost nitrogen/refrigerant gas. (h) After leak repair release Nitrogen and charge with refrigerant gas and testing to be carried out. Note : The cost for Nitrogen gas for Leak test, Charging/top up of Compressor oil and refrigerant gas (R-22) and necessery spares will be measured & Paid separately
Supply only Suction reed as per existing make and model .
Supply only Discharge reed as per existing make and model.
Supply only Main Bearing insert for connecting rod as per existing make and model
Supply only Piston Pin as per existing make and model.
Supply only Piston as per existing make and model.
Supply only compression Ring as per existing make and model
Supply only oil Ring as per existing make and model.
Supply only bolt with Nylock nut for connecting rod as per existing make and model
Supply only valve plate suction as per existing make and model
Supply only discharge valve guide assembly as per existing make and model
M&L for dismantling and overhauling of condenser/Chiller water pump set of capacity 10 HP, dismantling pump and motor separately, cutting the burnt out winding from slots and rewinding the same by existing size and gauge of super enamalled copper wire including varnishing, heating, repairing the insulating materials, repalcing bearings, bushes and remetalling the shaft including necessary heat treatment , and repairing the pump , including replacing the gland packing , bearings and all rusted nuts and bolts, washers and remetaling the Impeller of suitable size and bore for lifting the water from source and reassembling the motor and pump with gland packing includings painting of pump amd motor assambly complete with two coats of super enameled paints over one coats of red oxide, fixing the motor & pump at its position and connecting the suction and delivery water pipe and testing under working conditions, complete all as specified and directed.
All as per Sl Item No. 12 here- in- before but of capacity 7.5 HP complete all as specified and directed
M&L for repair and servicing to squirrel cage induction motor 3 phase 415V, 10 HP Kirlosker make or any others make by dismantling of motor from the pump set removing the stater/rotor separately, cleaning, varnishing, heating and drying re-erecting, aligning with the pump, testing, including replacing the bearing and bush, polishing and re-metalling the shaft including necessary heat treatment. Reassembling the motor and pump with new gland packing, supply and fix new gland nuts, bolts, with gland mounting nuts & bolts washers complete , painting the motor and pumps with two coats of synthetic enamel paint after preparing the surfaces all as directed by Engineer-in-charge. fixing the motor & pump on their own base and connecting the suction and delivery water pipes and testing with proper working condition complete all as directed .
All as per Sl Item No. 14 here- in- before but induction motor of capacity 7.5 HP complete all as directed .
Servicing and maintenance including Pressure testing / leak arresting , vaccumising with dry nitrogen gas / oil charging, incl replacing the unserviceable strainers all as required and testing complete for the Central type AC plant of capacity 85 TR at Ballistic center ,PXE . Note :- Quantity of Nitrogen gas used for leak testing and Antimoist for absorbing of moisture are included in the unit rates and Refregerant Gas , compresser oil will be measured and paid seperately complete all as directed.
All as per Sl Item No. 16 here- in- before but Central type AC plant of capacity 40 TR at Auditorium complete all as directed
All as per Sl Item No. 16 here- in- before but Package type AC plant of capacity 5.5 TR to 8.5 TR at any location/building of PXE tech area .
Supply only for Recharge/Top up refrigerant R- 22 (Mefron) or equivalent in Central type AC Plants at Auditorium and Ext AP Lab of various capacities complete all as specified and directed. Make : Mafron/Floron/Refron.
Supply only for Recharge/Top up Refrigerant (R-407) in AC plant at Ayudh Bhawan & AP Lab of various capacities complete all as specified and directed. Make : Mafron/Floron/Refron.
Supply only for Recharge/Top up of Refrigerant (R-134) in the AC plant at Ballistic Cente complete all as specified and directed. Make : Mafron/Floron/Refron.
Supply and charging/top up of compressor oil in compressor of Central type AC plant of capacity 40 TR including drain out old unserviceable compressor oil all as specified and directed. (Make : Freezal 68 / Vidol 68 or equivalent as approved)
Supply and charging/top up of Synthetic Screw compressor oil in Screw compressor of Central type AC plant of capacity 85 TR including drain out old unserviceable compressor oil all as specified and directed. (Make : Carrier grade 220vs / totaline or equivalent as approved)
M&L for Carrying out cleaning and descaling of iron deposited inside and outside of condenser shell and tube by using chemical suitable for descaling recommended by manufacturer manual of the respective plant, complete with satisfactory of capacity 3 x 40 TR Central AC Plant at Auditorium complete all as specifed and directed .
All as per Sl Item No. 24 here- in- before but for capacity 3 x 85 TR at Ballistic Centre AC Plant.
M&L for dismenteling and taking down unserviceable electric motor from compressor / AHU / Package AC unit of capacity 60 HP, 3 pahse, 415 volts of any make and type, Transportation to out side workshop for necessary repair/rewinding, dismantling of complete motor assembly, taking out burnt winding cleaning of core and rewiding with supper enamel copper wire of appropriate gauge/size and weight /turn as per existing including providing insulation materials, varnising , heating all as directed, repalcement of worn out bearings and carrying out painting by two coats of (1st quality) synthetic enameled paint over the existing painted surface after preparation and refixing to its original position with testing and commissioning comprete all as directed.
All as per Sl Item No. 26 here-in-before but 15 HP capacity.
All as per Sl Item No. 26 here-in-before but 3 HP capacity.
All as per Sl Item No. 26 here-in-before but 375 Watts /0.5 HP capacity.
Dismantling and taking down the electric motor of compressor / AHU / Package AC unit of capacity 20 HP capacity and transporting to work Shop and carrying out servicing/ maintenance of motor unit as per the following maintenance work:- (a) Opening of electric motor and cleaning/ removing dust from Armature and field coil (b) Cleaning of used/ old lubricated substance (c) Cleaning of starter and rotor unit (d) Checking and tightening of coupling, nuts, bolts and replacement of rubber insert. (e) Carrying out heat varnishing with varnish solution of best quality for field and armature coil. (f) Replacement of oil worn out bearings. (g) Reassembling the complete motor and carrying out testing at work Shop and transporting back to installation and coupling with pumping set including necessary alignment, cable connection all as directed.
All as per Sl Item No. 30 here-in-before but 7.5 HP capacity.
All as per Sl Item No. 30 here-in-before but 2 HP capacity.
M&L for dismenteling and taking down unserviceable screw type compressor unit of capacity 85 TR ,Central type AC plant at Ballastic Centre replacement of compressor oil,Drier core filter,internal/External oil filter , anti friction roller bearing , Packing Gaskets and repair of timing gear with other necessary work and re-assemble at its original position and testing all as directed. ( Make- Carrier ) NOTE- The spare parts to be measured and paid separately under Supply only items
Supply only Drier core/ filter including taking down, Make- Carrier,Cat part No-2000797
Supply only Internal oil filter including taking down, Make- Carrier,Cat part No-2001972
Supply only External oil filter including taking down, Make- Carrier,Cat part No-2000144
Taking down unserviceable outdoor unit and supply and replacement of Fin and tube type Condenser of 17.0 TR capacity,air cooled package type AC plant Condensing Unit including necessary repair/fabrication of base plate and connection including testing complete all as specified and directed
M & L for replacement of Unsv canvas cloth of package type AC planrs including provisiong of zip 150 mm lenth for opening and closing arrangements and properlly fasterners with bolts and nuts between the ducts all as directed by the Eng-in-charge
M & L for Supply , assembly and erection of GSS duct 120 GSM rectangular/ Square boxed, incl all accessories such as MS Angles frame at ducts joints for support of ducts , corner, cleat, carriage bolt Gasket and appropriate sealant on longitudinal joints etc comlpete of size 20 SWG icluding taking down unserviceable part and all as directed at site .Make :- SAIL/TATA/JINDAL
Supply and fix pillow block housing P209 with bearing UC 209 series as per existing size for shaft of AHU centrifugal fan support to arrest redial movement including taking down old unserviceable one. (Make – SKF/NBC/FAG)
Supply and fix charging valve of brass, size 3/8 inch and 1/4 inch as per existing size for Central type AC plant of capacity 40 TR including taking down old unserviceable one all as specified and directed.
Supply and fix expension valve VCP 100 as per existing size for Central type AC plant of capacity 40 TR including taking down old unserviceable one all as specified and directed. (Make – sporlan or equivalant)
Supply and fix compressor oil heater as per existing size for Central type AC plant of capacity 40 TR including taking down old unserviceable one all as specified and directed. (Make – sporlan or equivalant)
Supply and fix Water pressure gauge up to 0-10 kg/cm.sq along with fittings to be fitted on water pipe line including taking down old unserviceable one all as specified and directed
Supply&Replacement of 'V' Belt of size B-55 including taking down. Make :Fenner / Dunlop /Sonal/PIX
Supply & Replacement of 'V' Belt of size B-66 including taking down. Make : Fenner / Dunlop /Sonal/PIX
Supply & Replacement of 'V' Belt of size B-72 including taking down. Make : Fenner / Dunlop /Sonal/PIX
Supply & Replacement of' V' Belt of size A-32 including taking down. Make : Fenner / Dunlop /Sonal/PIX
Supply & Replacement of 'V' Belt of size SPA - 850 LdEL including taking down. Make : Fenner / Dunlop /Sonal/PIX
Supply & Replacement of' V' Belt of size A-125 including taking down. Make : Fenner / Dunlop /Sonal/PIX
Supply and fixing of Danfos make Scroll Compressor of 8.5TR capacity, for package plant of 17 TR, 3 phase 415V, thermally procted including testing etc complete all as directed. Make : Denfoss Model no: SZ110S4VC or equivalent.
Repairs of electronic printed circuit board (PCB) and replacement of relly ,wire connections fixing and testing complete for Central type AC plant of capacity 85 TR capacity all as specified and directed.
Supply only of HRC Fuse link type (HF) of capacity 100 Amps,415 volts including taking down. Make : C&S, Havells, L&T
Supply only power contractor 4 pole AC 3 22 A, 415 V Make Siemens Model 3TF3010.0A.8K or equivalent one all as specified and directed
Supply only power contractor 3 pole AC 3 , 3-16 A, 415 V Make Siemens Model 3TF3200.0A.8K or equivalent one all as specified and directed
M&L for painting to complete chilled water type Central Air Conditioning plant of 3X40 TR capacity at AC Auditorium, including complete compressor, motor, condenser refrigerant pipe, water pipe, chilled water pipe line, LT panel board complete plant with two coat of synthetic enamelled paint including preparation of surfaces and as per colour code all as specified and directed.
Supply and fixing of solonoed valve CE type ASC 24 volts 50 HZ 18 VA IP 65 with Connecting Wire as per existing size for Central type AC plant of capacity 85 TR including taking down old unserviceable one all as specified and directed. (MakeModel – VDE 0580 OF ALCO controls or equivalant)
Supply and fixing of Oil pump of screw compressor LS-159000 , Level switch VAP/N as per existing size for Central type AC plant of capacity 85 TR including taking down old unserviceable one all as specified and directed.
Supply only of HRC Fuse link type (HF) of capacity 32 Amps,415 volts including taking down. Make : C&S, Havells, L&T
Supply only of HRC Fuse link type (HF) of capacity 63 Amps,415 volts including taking down. Make : C&S, Havells, L&T
M&L for exposed duct thermal insulation with 50 mm thick thermocol including other binding like CPRX for fixing/bonding of thermocol and plastic and hassain clothes as covering mterials and finished with cement mortar / lath plaster with the help of wire mess of appropate size and finally painting two coat with suitable materialslike samosan/distamper or any other water resistance materials to match with existing surface complete all as specified and directed including taking down old unsv materials.
M&L for taking down old u/s structure framed and replacement with structure steel as required at site including fabrication , welding etc all as specified and directed
M/SNeelachal Enterprises
Bansal And Co
ALLIANCE
M/s LADHANIA BROTHERS
ELECTRO COMMERCIAL CO
M/s R.C REFRIGERATION
KRISHNA ENTERPRISES
chauhan syndicate
Bidder Name
DS ENTERPRISES
ALLIANCE
Bansal And Co
KRISHNA ENTERPRISES
M/s LADHANIA BROTHERS
M/s R.C REFRIGERATION
chauhan syndicate
ELECTRO COMMERCIAL CO
M/SNeelachal Enterprises
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .