| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹83.0 LAccepted-AOC COLABA MUMBAI | L1 | Accepted-AOC Accepted | |
| 2 | L2₹91.6 L+₹4.2 L (4.83%)Rejected-Finance | L2 | Rejected-Finance Being other then lowest | |
| 3 | L3₹93.3 L+₹6.0 L (6.83%)Rejected-Finance COLABA MUMBAI | YAVATMAL | MAHARASHTRA | 445001 | L3 | Rejected-Finance Being other then lowest | |
| 4 | L4₹94.8 L+₹7.5 L (8.54%)Rejected-Finance PLOT NO 1134 1196 MORIVALI VILLAGE TAL AMBARNATH DIST THANE AMBERNATH 421505 | AMBERNATH | THANE | MAHARASHTRA | 421505 | L4 | Rejected-Finance Being other then lowest |
Tender Value
Refer Docs
EMD Value
₹1.5 L
Closing Date
13 Nov 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE NW Mumbai
Commander Works Engineer NW Dr Homi Bhabha Road Navy Nagar ColabaMumbai 05
REPAIRS AND ROUTINE MAINTENANCE OF PASSENGER AND GOODS LIFT OF VARIOUS COMPLEX UNDER GE NW KUNJALI COLABA MUMBAI
2020_MES_384475_1
8388/CWE(NW)/MUMBAI
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GE (NW) KUNJALI
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
Yes
GE (NW) Kunjali
₹1.5 L
Yes
9 Dec 2020
8 Oct 2020
16 Nov 2020
8 Oct 2020
13 Nov 2020
30 Oct 2020
8 Oct 2020 - 29 Oct 2020
60 days
Amount
Repair and routine maintenance of lifts including carrying out daily check and periodical services of fully automatic electrical Dumbwaitr,passenger Monarch make lift 13 passenger 884 Kg capacity with power operated door simplex collective control system to serve (G+5), upper floors-01 lift OF MSYS department of centre 37 & 13 Passenger 884 kgs of make ECE elevators lift ARF department -01 N lift including repair/replacement of unserviceable parts such as bearings, bushes, all types of shoes, headers, hangers, door rope, door cards, door locks, control cards, and its contacts, control connector/ links, hall push buttons and its covers, welding of cracks/ broken any MS items/ parts, repair/ replacement (in case of unservicable) of door drive door safety edge working at any principle and any type of sensor or mechanical safety lock, magnetic lock or contact,shaft limit switches, COP buttons, car position indicator, car door sills and landing door sills, Fire alaram toggal switches,intercoms, smoke detactor, mainentance of VVVF drive and Auto Rescue Device, repairs of wiring & cables as per requirement for safe operation of lift, cabin fan, cabin light etc,complete to ensure safety and smooth operation of lift and as directed by Engineer-in-Charge total-02 Nos. Note:- (a) If Major items such as ARD,VVVF drive ,Control panel etc required for replacement same shall be measured and paid separatelly under respective items. Mechanic/labour shall attend & rectify the defects on pirority and making the lift smooth functioning.(b) Rewinding of motor if required will be done by the contractor and no extra cost will be given by the department.(c) The mechanic shall check all the lifts and carryout routine checkup /maintenace as directed by Engr-in-Charge or concerned JE E/M and prepare daily,weekely, monthly and yearly report as per maintenance format given in the contract.(d) Attendance of the mechanic duly singed to be submited to the concerned JE E/M and Engineer -in- Charge before making any payment to the contractor.
All as per item No 1 above but 08Ps (554)Kgs Eltech make elevators of wecors department -1 Lift to serve with (G+5) upper floors auto door at Naval dockyard (Total 01 No)
All as per item No 1 above but Passenger lift (500)Kgs Pece elevators make of MMER deaprtment of centre No-70 -01 No lift at Naval dockyard (Total 01 No)
All as per item No 1 above but passenger lift(680)Kgs Schinider make elevators of wecors department to serve (G+2) upper floors with auto door Make Monarch in Steam test house centre 75 at Naval dockyard (Total 01 Nos)
All as per item No 1 above but passenger lift(272)Kgs OTIS make elevators of COFY department of centre No 69 -01 No lift to serve (G+4) upper floors manully operated collapsible doors at Naval dockyard (Total 01 Nos)
Alll as per item No 1 above but passenger lift(884)Kgs Thyssenkrup Elevators make of wecors department -01 No lift, OTIS make elevators of MMER deartment & PM building department -02 Nos lifts to serve (G+3) upper floors at Naval dockyard (Total 03 Nos)
Alll as per item No 1 above but Goods lift(1000)Kgs to serve (G+M+1+2) upper floors with manually operated doors Make Monarch of MAST building of centre 43 at Naval dockyard (Total 01 Nos)
Alll as per item No 1 above butt passenger lift(1500)Kgs to serve with (G+3) upper floors with auto door Make Monarch in Quality control department centre 74 -01 No lift & MCM department of centre 61 -01 No lift at Naval dockyard (Total 02 Nos)
Alll as per item No 1 above but Goods lift(2000)Kgs to serve (G+M+1+2) upper floors with collapsible doors Make Monarch in MSYS department of centre 37 -01 No lift & 2000Kgs Goods lift of Pace elevators at Wecors department -01 No lift at Naval dockyard (Total 02 Nos Lift)
Alll as per item No 1 above but dumwaiter lift (250)Kgs to serve (G+1+2) upper floors with manually operated vertical painting doors Make Monarch of NDIC canteen department of centre-99 at Naval dockyard (Total 01 Nos)
Alll as per item No 1 above but Goods lift(2000)Kgs to serve (G+M+1+2) upper floors with manually operated doors Make ECE elevators of CMS department of centre 27 at Naval dockyard (Total 01 Nos)
Alll as per item No 1 above but fully automatic electrical 08 passenger (544Kg) capacity lift of MFAB department of make Bhawani Elevators-01 No lift & 08 passenger (544Kg) capacity lift of OTIS Make elevators of PM bldg-01 No lift with power operated door simplex collective control system to serve (G+M+1+2), upper floors Make of lift Monach Elevaotrs of Fabrication department of Centre No11 at Naval Dockyard total-02 Nos.
All as per item No 1 above but with auto door 680 kg passenger lift(1088)Kgs to serve (G+M+1+2) upper floors Make Thyssenkrup elevators in MSTH department of centre 75-01 No lift at Naval dockyard (Total 01 No)
All as per item No 1 above but with auto door 16 passenger lift(1088) Kgs to serve (G+M+1+2) upper floors Make OTIS in MFAB of DOM department at Naval dockyard (Total 01 No)
All as per item No 1 above but Collapsible door to serve (G+1) upper floors & 1500 Kg Goods lift Monarch Make of MDAG department at centre 32 at Naval Dockyard (Total 01 Nos)
All as per item No 1 above but with collapsible door Monarch make Goods Elevators 2000Kgs of MEPS department of centre No 45-02 No lift, MECE departmet of centre 47-02 No lifts & IRC department of centre No 101 at Naval Dockyard (Total-05 Nos).
All as per item No 1 above but with collapsible door but Goods lift 2000 Kgs of ECE Elevators make of ARF department -01 No lift & 2000Kgs Goods lift of make ECE/Monarch of MYAS department of centre 64-01 No lift to serve (G+M+1+2+3) upper floors at Naval dockyard (Total-02 Nos)
All as per item No 1 above but Manual door Thyssenkrup Elevators make 2000Kg Goods lift of MFAB department of Centre 12 -02 Nos lifts & OTIS make Goods elevator 2000Kgs of MDDHP department of centre 20 to serve (G+M+1+2) upper floors at Naval Dockyard (Total 03 Nos)
All as per item No 1 above but with collapsible door 3000Kgs Goods lift of Thyssendrup elevator make of department MMER of centre No 70 -01 No lift to serve with (G+M+1+2) upper floors at Naval dockyard (Total 01 Nos)
All as per item No 1 above but fully automatic electrical 13 passenger Monarch make lift (844Kg) capacity with power operated door simplex collective control system to serve (G+M+1+2), upper floors including mazinine floor. Monach make Elevaotrs of MEPS department of Centre 45-02 lifts & Monarch make elevators COFY department of centre 69- 02 Nos lift at Naval Dockyard total-04 No lifts.
All as per item No 1 above but collapsible door of department MBEF of centre No 40/41 Goods lift(1500)Kgs to serve (G+M+1+2) upper floors Make Monarch at Naval dockyard (Total 01 No)
All as per item No 1 above but with auto door 16 passenger lift(1088)Kgs to serve (G+M+1+2) upper floors Make Monarch in MDAG department of centre 32-02 No Lifts at Naval dockyard (Total 02 No)
All as per item No 1 above but collapsible door Goods lifts (2000)Kgs to serve (G+M+1+2) upper floors Make Monarch in MOUT department of centre 22 -02 No lifts, MAST department of centre 29-01 No lift & MSYS department of centre No 37 -02 No Lifts at Naval dockyard (Total 05 Nos Lifts)
All as per item No 1 above but with collapsible door Monarch make Goods lift 3000 kgs capacity of MFAB department of centre No 11 & MDAG department of centre No 32 Goods lift (3000 kg) to serve (G+M+1+2) upper floors of wecors department to serve (G+M+1+2) upper floor at Naval dockyard (Total 02 No lifts).
Note for item Nos 1 to 24 above :- (a) There shall be two category of operators :- (i) One category is Rescue Operator who shall be invariably ITI qualified and trained for Rescue Operation for all the building - Each shift. (ii) The other category is for Lift mechanic (skilled) duly trained for all building (b) Rescue operator having ITI qualification with at least 02 (Two) years practical experience shall posses thorough knowledge to rescue user in case of emergency like anybody getting trapped in lifts (Rescue Operator) for all building - Each Shift (c) Passes will be processed alongwith (after verification on signed certificate, verified ITI certificate only. Pass shall not be granted without submission of ITI qualification proof & experience certificate. (d) Contractor shall submit ID proof, Residential proof, Bank A/C details to department and obtain approval of Engrr-in-Charge before employing a person as Lift mechanic and Rescue Operator. (e) Payment to Lift mechanic and Rescue Operators shall be done by crossed cheque only which shall not be less than minimum fare wages as per Act in vouge. The contractor shall submit proof to Engineer-in-Charge before claiming any payment. After entire satisfaction of Engineer-in-Charge the payment action shall be processed further. (f) Rescue Operators shall be trained for rescue passangers of lift by an enlisted OEM / Lift maintenance contractor / Lift maintenance having approval lift licence issued by lift inspector of PWD and certificate for the same be submitted with proposal for passes.
(g) Lift mechanic shall be available as per the shift timings specified in the tender and he will report to JE E/M in-Charge or Lift Cell in-Charge. In case of emergency he will function according to their direction. If he is found absent or move without intimating to in-Charge of Lift Cell or JE E/M he will be treated as absent for the said shift and recovery to this effect for Rs 1500/- per shift shall affected. (h) Payment as per quoted rate shall also be deducted in addn to the penalty as specified above. (j) In case of malfunctioning if any noticed, lift operator shall intimate to the lift cell. (k) In case of any necessity for rescue operation or accident, Rescue Operator shall be capable of rescue the passenger and reacting to the situation (accident etc) (l) Contractor shall submit the labour licenece and Copy of GST Regn registered number issued by concerned authority. (m) Insurance coverage, compensation if any applicable or necessitated due to mis operation of lift shall be the responsibility of contractor. The quantum of compensation shall be assessed based on the BOO composing of Lift Inspector of Maharashtra State, representatives of both agencies carrying out M&O works and routine maintenance work of lift and members from department.
Taking out of unserviceable governor steel wire rope after disconnecting. supply and fix new steel wire rope 8mm dia, 8/19 construction including necessary connection with pully in machine room and shaft pit complete with clamp, nut, bolt, washer, etc 544Kg /1088 Kg at Fabrication department at Naval Dockyard complete all as specified and directed
Replacement of old unserviceable hall push butten assembly with new hall push button assemblyand including control/electric connection complete with illuminated push button and direction indicator with 7 segment LED display with LPI/ LPC card of stainless steel face plate to match with the existing card/ control system, including cutting of wall and making good disturbed surface with masonry work to match with existing surface for Goods lift east side of System depatment at centre 37 & Goods lift 2000Kg west complete all as specified and directed
Dismantling and taking out of unservicable main steel wire rope after necessary disconnecting from counter weight pulley and car cabin and supplying and fixing new main steel wire rope 13mm dia 8/19 construction (Make - USHA MARTIN) including proper necessary connection with counter weight pulley and car cabin with clamps, bolts, washers, etc confirming to IS-14865 latest edition in Passenger lift OF 544Kg /1088 Kg at Fabrication department at Naval Dockyard.
Disconnecting and takingout unservicable emergency alarm system Complete S&F new emergency alarm system assembly on ground floor landing complete with PCB card battery backup battery charging unit and speaker including necessary control/electric connection wiring with COP and control panel complete all as specified and directed Central machine shope and various other lift of Naval dockyard.
Replacement of car cabin fan from car cabin supply and fixing of new cabin fan non-oscillating type axial flow single speed 300mm sweep 240volts ISI mark with grill complete Make : EMCO/VBM/CINNI complete all as specified and directed at D& G department and certain other lifts of Naval dockyard.
Dismantling and taking out unserviceable travelling cable from hoist way and supply & fixing new travelling cable PVC insulated 16core flat/round type with multistranded copper conductor 1100 Volts grade of size 0.75Sqmm confirming to IS and including thimbless suspended type freely move with car cabin up and down movements between ground and upper floors including necessary proper connectiion with Mid way junction and other connection required in circuit for passenger & Goods Lift of Naval Dockyard complete all as specified and directed
Dissmantaling and Taking out all defective batteries from Existing ARD and supply and fixing new maintenance free batteries sutaible for ARD including necessary connection like battery terminals of brass and copper lead heavy duty to connect the battery terminal of 12VDC,17AH(04nos batteries) for each ARD,(Make:Exide) complete all as specified and directed
Complete removal of paint from lift Machine, gearbox, main traction pulley & MS landing door by paint removers or any other menthod and applying a coat of red oxide primer and 02 coats of synthetic enamel paint, by spray painting on both side of landing door and Main machine of ,Gear box main traction pulley including I section beams colour black/blue complete all as specified and directed
Disconnecting and taking out unserviceable COP assembly and supply,fixing and testing new car oprating panel assembly complete with illuminated push button for floor position alaram non stop ,DOOR CLOSE ,DOOR OPEN CABIN FAN CABIN LIGHT stop attend out key etc in and including direction indicator with 7segment display with CPI card and stainless steel face plate duly connecting with existing control and electric system complete all as specified and directed
Replacement of existing unservicable shaft wiring in hoist way with new shaft wiring in hoist way upto lower limit switch with PVC insulated with multi standard copper conductor 0.75 sqmm & 01 sqmm for earthing, 1100volts grade drawing through in and including galvanised sheet metal trunking (24Swg) up to ground floor in hoist way for control of all floor hall push button assy, limit switches, terminal switches, fireman switches etc complete all duly earthed at all points, suitable for Lift complete all as specified and directed
Disconnecting and taking out unserviceable defective main VVVF drive from existing control pannel, S&F new main VVVF drive unit of make : Yashikawa(Japan) suitable 12.5 KW capacity in existing panel and connected with existing system including testing and commissioning complete for smooth functioning jerk free working of lift with all necessary electric connection all as specified and directed by Engr-in-Charge at NWRF lift 2 ( 2000 kgs) at Naval Dockyard
Shree Elevator Engineering Co.
Escon Elevators Pvt Ltd
shakti engineering and electrical works
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .