Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.0 LAccepted-AOC | ₹20.0 L | L1 | Accepted-AOC L1 |
| 2 | L2₹20.2 LRejected-Finance | ₹20.2 L | L2 | Rejected-Finance L2 |
| 3 | L3₹20.6 LRejected-Finance | ₹20.6 L | L3 | Rejected-Finance L3 |
Tender Value
₹20 L
EMD Value
₹20,000
Closing Date
2 Jan 2026, 11:05 amClosed
EDUCATION OFFICER PRIMARY
EDUCATION OFFICER PRIMARY
PROVIDING SPECIAL REPAIR WORK FOR URDU VIDYA MANDIR KABNUR TAL-HATKANANGALE DIST-KOLHAPUR
2025_KOLHA_1263202_3
E tender No.12/2025-2026
Open Tender
Civil Works
180 days
Z P KOLHAPUR
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,000
₹20,000
20 May 2026
25 Dec 2025
3 Jan 2026
25 Dec 2025
2 Jan 2026
25 Dec 2025
Removing cement tiles, or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts excetra complete. Item / Page No : 19 / 297 Additional Specifications : The work shall be carried out as directed by Engineer-In-Charge.
Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 metre beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting excetra complete. - (Lift upto 1.5 metre) By Manual Means Item / Page No : 1 / 153 Specification No : Bd.A.1 Spec. Page No : 259
Providing and laying Cast in situ / Ready mix cement concrete M-20 of trap / granite / quartzite / gneiss metal for steps including steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing, excetra complete. The cement mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin, excetra (Wooden centering will not be allowed.) with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 6 / 175 Specification No : Bd.E.2, B-7 Spec. Page No : 288, 38-40 Additional Specifications : 1. With additional specifications for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Providing and laying Cast in situ/Ready Mix, cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailling out water, formwork, laying/ pumping, compacting and curing, excetra complete, with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed, excetra) (using ARTIFICIAL SAND). Item / Page No : 1 / 175 Specification No : Bd.E.1 Spec. Page No : 287-288 Additional Specifications : 1. With additional specifications for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Providing and laying vitrified matt finish tiles of having size 590 milimetre to 605 milimetre X to 605 milimetre of 8 milimetre to 10 milimetre thickness and confirming to Indian Standard 15622-2006 (Group BIa) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 42 / 217 Specification No : Bd.M.12 Spec. Page No : 385 Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Providing and laying vitrified matt finish tiles having size 590 milimetre to 605 milimetre X to 605 milimetre of 8 milimetre to 10 milimetre thickness and confirming to Indian Standard 15622-2006 (Group BIa) of approved make, shade and pattern for dado and skirting in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 43 / 217 Specification No : Bd.M.12 Spec. Page No : 385 Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Providing and fixing of Mineral Fibre Acoustical Suspended Ceiling System with Fine Fissured (Bevelled Tegular) Edge Tiles With 15 milimetre Exposed Grid. The tiles should have Humidity Resistance (RH) of 99%,NRC 0.6, Light Reflectance .85 percent, Thermal Conductivity k = 0.052 - 0.057 w/m K, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 &7) in module size of 600 X 600 X 16 milimetre, with Recycled content of 31 percent. The tile shall be laid on precoated G.I channel height of 32 with 15 milimetre wide T - section flanges colour white having rotary stitching and XL2 CLIP on all T sections i.e. the Main Runner, 1200 milimetre and 600 milimetre Cross Tees with a web height of 32 milimetre and a load carrying capacity of 7.57 kilogram per square metre and pull out stength of minimum 100 Kgs.. The T Sections have a Galvanizing of 90 grams per square metre and need to be installed with Suspension system. The Tile and Grid system used together should carry a 10 year warranty. product approved in GRIHA and BS 476, excetra complete. Item / Page No : 50 / 243 Additional Specifications : The work shall be done as per instructions of Engineer in charge.
Removing galvanised iron or asbestos cement sheet roofing including purlines, principal rafter excetra including sorting servicable and unserviceable materials, stacking the same as and where directed in the compound including scaffolding, excetra complete. (For Ground Floor) Item / Page No : 26 / 235 Additional Specifications : The work shall be done as per instructions of Engineer in charge.
Providing and fixing of colour coated zincalume (R) AZ 150 (Minimum 150 grams per square metre total on each sides) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 milimetre base metal thickness (BMT) (0.5 milimetre TCT), Hi-strength steel with minium 550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55 percent aluminium, 43.4 percent zinc, 1.6 percent silicon) with COLORBOND (R) steel quality super durable polyster paint coat (with inorganic pigment). The paint shall have a total coating thickness of nominal 35 um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nominal 950-1050 milimetre effective cover width and nominal 25-30 milimetre deep ribs with subtle square fluting in the five pan at nominal 180-250 milimetre center to centre. The end rib shall be designed for anti capilary groove and return leg. The feed material should have coil manufacturer's product details marked at regular interval. Including fasteners with minium fatened with minium 25 um zinc-tin alloy coated, hex head, self-drilling screw, excetra complete. (Weight of profile 4.52 kilogram per square metre). - 601 milimetre to 900 milimetre girth (surface width) (For Ground Floor) Item / Page No : 36 / 237 Additional Specifications : The work shall be done as per instructions of Engineer in charge.
Providing and fixing of colour coated zincalume (R) AZ 150 (Minimum 150 grams per square metre total on each sides) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 milimetre base metal thickness (BMT) (0.5 milimetre TCT), Hi-strength steel with minium 550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55 percent aluminium, 43.4 percent zinc, 1.6 percent silicon) with COLORBOND (R) steel quality super durable polyster paint coat (with inorganic pigment). The paint shall have a total coating thickness of nominal 35 um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nominal 950-1050 milimetre effective cover width and nominal 25-30 milimetre deep ribs with subtle square fluting in the five pan at nominal 180-250 milimetre center to centre. The end rib shall be designed for anti capilary groove and return leg. The feed material should have coil manufacturer's product details marked at regular interval. Including fasteners with minium fatened with minium 25 um zinc-tin alloy coated, hex head, self-drilling screw, excetra complete. (Weight of profile 4.52 kilogram per square metre). - 301 milimetre to 600 milimetre girth (surface width) (For Ground Floor) Item / Page No : 35 / 237 Additional Specifications : The work shall be done as per instructions of Engineer in charge.
Providing second class Burnt Brick masonry with conventional / Indian Standard type bricks in cement mortar 1:6 superstructure including striking joints, racking out joints, watering and scaffolding, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 5 / 197 Specification No : Bd.G.5 Spec. Page No : 315 Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Providing internal cement plaster 20 milimetre thick in single coat in cement mortar 1:5 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 6 / 209 Specification No : Bd.L.4 Spec. Page No : 368 Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Providing sand faced plaster externally in cement mortar using approved screened sand in all positions including base coat of 15 milimetre thick in cement mortar 1:4 using waterproofing compound at one killogramme per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment of 6 to 8 milimetre thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days, scaffolding, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 11 / 209 Specification No : Bd.L.7 Spec. Page No : 369 Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Providing structural steel work in hollow section of various thickness and sizes in square, rectanular and round shape from 25 milimetre to 450 milimetre section as per Indian Standard : 4923 YST 310 grade produced from iron ore and blast furnace route, excetra as per detailed designs and drawing or as directed including cutting, fabricating, hoisting, erecting, fixing in position, making riveted / bolted / welded connections and painting complete. (For Ground Floor) Item / Page No : 12 / 174 Additional Specifications : Work shall be carried out as per the instructions of Engineer In-Charge.
Providing and laying cast in situ / Ready Mix cement concrete M-40 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks,laying / pumping, compaction and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 58 / 182 Specification No : Bd.F.6, B-7 Spec. Page No : 300-301, 38-40 Additional Specifications : 1. With additional specifications for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Providing and fixing in position thermo mechnically treated FE-500 steel bar reinforcement of various dias for reinforced cement concrete pile caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardis, copings, fins, arches, excetra as per detailed designs, drawings and schedules including cutting, bendding, hooking the bars, binding with wires or tack welding and supporting as requied complete. (For Ground Floor) Item / Page No : 33 / 188 Specification No : Bd.F.17 Spec. Page No : 306
Providing and fixing mild steel grill railing weighing 20 kilogram per square metre with polyvinyl chloride handrail cover and newel post for staircases, including fabricating, fixtures, drilling holes in concrete / other surface, erecting the grill work, necessary welding, fixing by nuts and bolts, fixing polyvinyl chloride handrail cover, with one coat of anticorrosive paint and two coats of oil painting with approved colour and shade, remaking the damaged surface, cleaning, excetra complete. (For Ground Floor) Item / Page No : 11 / 265 Additional Specifications : The work shall be carried out as directed by Engineer-In-Charge.
Providing and fabricting structural steel work in rolled sections like joists, channels, angles, tees, excetra as per detailed designs and drawing or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted / welded connections without connecting plates, braces, excetra and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade, excetra complete. (For Ground Floor) Item / Page No : 1 / 173 Specification No : Bd.C.2 Spec. Page No : 275
Providing and fixing plain zinc sheeting of 0.80 milimetre thick (22 B.W.G) over the ridge hip or valley to galvanized iron sheet roofing including all fastening and bolt, galvanised iron screw and bolts and lead and bitumen washers, excetra complete. (Weight 6.8 killogram per square metre) (For Ground Floor) Item / Page No : 5 / 233 Specification No : Bd.R.5 Spec. Page No : 452-453
Providing and applying priming coat on concrete / masonary / asbestos cement / plastered surfaces including scaffolding if necessary, preparing the surface by throughly cleaning oil, grease, dirt and other foreign matters and sand papering as required, excetra comlpete. (For Ground Floor) Item / Page No : 21 / 225 Additional Specifications : The work shall be carried out as per instructions of Engineer in charge.
Providing and applying two coats of exterior weather shield paint of approved manufacturer and of approved colour to the plastered surfaces including cleaning, preparing the plaster surfaces, applying primer coat, scaffolding, if necessary and watering the surface for two days, excetra complete. (For Ground Floor) Item / Page No : 26 / 225 Additional Specifications : The work shall be carried out as per instructions of Engineer in charge.
Providing second class burnt brick masonry with conventional / Indian Standard type bricks in cement mortar 1:6 in foundations and plinth of inner walls / in plinth of external walls including bailling out water manually, striking joints, on unexposed faces, racking out joints on exposed faces and watering, excetra complete. (using ARTIFICIAL SAND). Item / Page No : 1 / 197 Specification No : Bd.G.1 Spec. Page No : 313 Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Providing and laying chequered tiles of approved quality of size 30 centimetre X 30 centimetre and confirming to indian standard for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning, curing, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 66 / 220 Specification No : Bd.M.12 Spec. Page No : 385 Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Providing and fixing heavy duty inter locking concrete rubber mould glossy paving blocks of 80 milimetre thickness of having a strength of 400 kilogramme per square centimetre of approved quality and shape on a bed of crushed sand of 25 milimetre to 30 milimetre thick including striking joints and cleaning, excetra complete.(using 100 percent crushed sand) Item / Page No : 54 / 219 Specification No : Bd.M Spec. Page No : --- Additional Specifications : The work shall be carried out as per instructions of Engineer in charge.
Supplying soft murum at the road site, including conveying and stacking, excetra complete. Item / Page No : 29b / 25 Specification No : MORTH-408 Spec. Page No : 139-142
ADD GST Non-Dsr Item Additional Specifications : The work shall be carried out as per the instructions of Engineer in-charge.
ADD GST Non-Dsr Item Additional Specifications : The work shall be carried out as per the instructions of Engineer in-charge.
ADD ELECTRIFICATION Non-Dsr Item Additional Specifications : The work shall be carried out as per the instructions of Engineer in-charge.
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.16 MB
SBDEDUCATION.pdf
Tender Documents • 0.86 MB
BOQ_2176765.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid