Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.0 LAccepted-AOC 254 MG ROAD LAMBA LANE JUNGLIGHAT PORT BLAIR SOUTH ANDAMAN ANDAMAN AND NICOBAR ISLANDS 744103 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹16.7 L+₹73,482 (4.60%)Rejected-Finance 19 I V I P ROAD JUNGLIGHAT PORT BLAIR 744 103 | PORT BLAIR | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744103 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹17.7 L+₹1.7 L (10.8%)Rejected-Finance OPP MARUTI SERVICE CENTRE SARACHARMA POST SRI VIJAYA PURAM 744 105 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744105 | L3 | Rejected-Finance Not Lowest | |
| 4 | Rejected-Technical | - | Rejected-Technical Not enlisted in c(vii) Category | |
| 5 | Rejected-Technical | - | Rejected-Technical Not enlisted in c(vii) Category |
Tender Value
₹15.0 L
EMD Value
₹30,000
Closing Date
8 Feb 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer Haddo
GARRISON ENGINEER HADDO Military Engineer Services Haddo Post Port Blair Andaman and Nicobar 744102
PROVISION OF FILTERATION PLANT FOR JAPANESE WELL ALONG WITH PUMPING FACILITY NEAR JARAWA SLOPE UNDER GE HADDO, PORT BLAIR
2022_MES_502473_1
8599/GE/H/PB
Open Tender
Civil Works
Item Rate
180 days
GE Haddo Port Blair
Class E Category c (vii)
9 documents required · 9 mandatory
₹500
GE Haddo
₹30,000
Yes
8 Mar 2022
19 Jan 2022
12 Feb 2022
19 Jan 2022
8 Feb 2022
3 Feb 2022
19 Jan 2022 - 31 Jan 2022
60 days
Amount
M&L for 80mm dia or bore galvanised steel tubing, medium grade, with all fittings and fixed to walls/ceilings or laid in floors complete all as specified and as directed.
M&L for 50mm dia or bore galvanised steel tubing, medium grade, with all fittings and fixed to walls/ceilings or laid in floors complete all as specified and as directed.
M&L for 40mm dia or bore galvanised steel tubing, medium grade, with all fittings and fixed to walls/ceilings or laid in floors complete all as specified and as directed.
M&L for 25mm dia or bore galvanised steel tubing, medium grade, with all fittings and fixed to walls/ceilings or laid in floors complete all as specified and as directed.
Supply, install, test & commissioning of monoblock centrifugal pumpset with CI impeller, 3-phase, 415 volts, 5HP / 3.72KW having head 24 RM , discharge of 10 LPS and RPM of 2870 heavy duty conforming to IS, with necessary GI fittings for suction and delivery lines and base frame of structural steel embedded in PCC (1:2:4) type B-1 with suitable anchorage complete all as specified and directed. Make: Kirloskar KDS-527++ / Texmo / Taro / Crompton Greaves Note: The cost includes 3 core 10sqmm copper submersible cable from LT panel to pumpset
S&F 80mm dia gun metal, globe or gate valves (ISI marked), with iron wheel head, screwed both ends for iron or CPVC pipe, fixed in repairs complete all as specified and as directed. MAKE: ZOLOTO/LEADER/NETA
S&F 50mm dia gun metal, globe or gate valves (ISI marked), with iron wheel head, screwed both ends for iron or CPVC pipe, fixed in repairs complete all as specified and as directed. MAKE: ZOLOTO/LEADER/NETA
S&F 40mm dia gun metal, globe or gate valves (ISI marked), with iron wheel head, screwed both ends for iron or CPVC pipe, fixed in repairs complete all as specified and as directed. MAKE: ZOLOTO/LEADER/NETA
S&F 25mm dia gun metal, globe or gate valves (ISI marked), with iron wheel head, screwed both ends for iron or CPVC pipe, fixed in repairs complete all as specified and as directed. MAKE: ZOLOTO/LEADER/NETA
S&F rotational moulded polyethylene water storage tanks, triple layered, ISI marked (cylindrical vertical with closed top), 10000 litres capacity, hoisted and fixed in position all as specified in SSR Part I, 2009 including 25mm dia or bore PTMT ball valve high pressure with epoxy coated aluminium rod & high density plastic ball (minimum weight 455gms) screwed for iron pipe, provision of 25mm GI medium grade pipe for connecting inlet, outlet, over flow and washout pipes including taking down old unserviceable tank with fixtures complete all as specified and as directed.
M&L for LT UG XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 16 Sqmm, 4 core laid in trenches/floors/ducts or fixed on poles/walls/roofs/MS supports or drawn through pipes etc., including suitable size of cable lugs for incoming and outgoing, connecting, testing and commissioning complete all as specified and as directed. MAKE: HAVELLS/ FINOLEX/ UNIVERSAL/ GLOSTER/CCI
M&L for testing & comissioning of 5000 Ltrs/hr WATER TREATMENT PLANT including suitable feed pumps, hypo disinfection, pressure sand filter, activated carbon filter with all accessories complete all as specified and as directed. Other specifications of due accessories are :- (i) Raw water feed centrifugal monoblock pump of capacity 2 HP, 6 cum/hr, 25 meter head and CI casing. (ii) Hypo chlorite dosing system with digital metering pump of Make E-dose and having 30 ltrs HDPE tank and 25kgs of 4-5% hypo chloritre solution. (iii) Pressure sand filter having capacity of 5000 ltrs/hr, fiber reinforced vessel of suitable dimensions with required pressure gauges, vaccuum breakers and suitable inlet and outlet valves. (iv) Carbon filter having capacity of 5000 ltrs/hr, fibre reinforced vessel of suitable dimensions with required pressure gauges, vaccuum breakers and suitable inlet and outlet valves. Make: ION Exchange (India) Ltd. / Sathya Sai Aqua Pura Services / Optimus Enviropro Pvt. Ltd. or any other MES approved make. Note: The quoted rate includesspare filters and chemicals should be produced to department.
M&L for HDPE DWC (Double wall corrugated) pipe of size 50mm (Outer diameter) x 38mm (Inner diameter) along with connected accessories like couplers, bends, end caps etc., laid in trenches/floors/ducts or fixed on poles/walls for as in protection of LT/ HT cable complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 m in depth, for foundation of poles, stays, struts or for laying cables/pipes etc., not exceeding 10 Sqm on plan and not exceeding 1.5m in depth and getting out in soft/loose soil complete all as specified and as directed. NOTE: 1. If new cable is laid as replacement of old cable in the same trench, all excavation and earth work shall be measured only once. 2. If any pipe is laid in trenches as cable protection, all excavation and earth work shall be measured either for cable or for pipe only and not for both. 3. If cable is laid in tiers and in loops, all excavation and earth work shall be measured accordingly.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each as in soils complete all as specified and as directed.
Removing excavated material (soils) to a distance not exceeding 50 metres and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed.
M&L for PCC (1:4:8) type D2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed.
S&F cast iron non-return valve with bypass arrangement, ISI marked, 50 mm bore, both ends flanged & drilled including neoprene rubber gasket, stainless steel bolts, nuts and washers complete all as specified and as directed. MAKE: KIRLOSKAR/UPADHYAY/VENUS/DURGA/KESORAM
M&L for earthing complete with GI earth plate electrode of size 600mmx600mmx6mm thick, 40mm bore buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of the earth plate not less than 1.5m below normal ground level connected to 32x6mm GI earth strip as earth lead connected by means of bolts, nuts, washers and check nuts made out of galvanised iron or steel all as shown on electrical plate No. 3 of SSR Part-I connected to common earth dolly including testing on completion including demolition of old unserviceable earth pit and taking out earthing material from pit complete all as specified and directed. NOTES: 1) The unit rate shall also include for earth work in any type of soil, PCC (1:3:6) type C1 chamber, pre-cast RCC (1:2:4) type B-1 using 20mm graded stone aggregate cover 50mm thick reinforced with TMT bars 8mm dia @ 100mm c/c both ways, funnel with watering pipe 20mm dia medium grade, GI protection pipe light grade 40mm dia and wire mesh complete in addition to item No. 1(a) to (e) of preamble (notes) under sub-heading earthing, specified on Sl. Page Nos. 422 & 423 of SSR Part-II. 2) Earthing lead and GI protection pipe beyond 7.5m will be measured and paid separately.
surendra infrastructure pvt ltd
M/s Ramesh Lal
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .