Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.4 LAccepted-AOC 1 TROPICAL REFRIGERATION PHONIX BAY PORT BLAIR PORT BLAIR ANDAMAN NICOBAR 744101 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744101 | ₹31.4 L | L1 | Accepted-AOC Being Lowest |
| 2 | L2₹33.0 L+₹1.6 L (4.96%)Rejected-AOC | ₹33.0 L+₹1.6 L (4.96%) | L2 | Rejected-AOC Not Lowest |
| 3 | L3₹35.8 L+₹4.4 L (13.9%)Rejected-AOC | ₹35.8 L+₹4.4 L (13.9%) | L3 | Rejected-AOC Not Lowest |
| 4 | L4₹38.8 L+₹7.4 L (23.4%)Rejected-AOC | ₹38.8 L+₹7.4 L (23.4%) | L4 | Rejected-AOC Not Lowest |
| 5 | L5₹41.4 L+₹10.0 L (31.7%)Rejected-AOC | ₹41.4 L+₹10.0 L (31.7%) | L5 | Rejected-AOC Not Lowest |
Tender Value
₹36 L
EMD Value
₹72,000
Closing Date
29 Jul 2020, 6:00 pmClosed
Col PS Chand, CWE
Commander Works Engineer Military Engineer Service Junglighat PO Minniebay Port Blair 744 103
80899 Provision of 2 Nos Cold rooms at Bldg No T-18 BVY PBR Under GE Minniebay
2020_MES_358366_1
80899 Provn of 2 nos Cold Rooms BVY-GE Minniebay
Open Tender
Civil Works - Others
Item Rate
120 days
Garrison Engineer Minniebay
As per Tender Dcouments
8 documents required · 8 mandatory
₹500
Garrison Engineer Minniebay
₹72,000
Yes
21 Sept 2020
4 Jul 2020
4 Aug 2020
4 Jul 2020
29 Jul 2020
22 Jul 2020
Amount
Supply, install, test and commissioning of air cooled split units (1 running & 1 standby) for refrigeration capacity suitable for room size 17.77x12.62x7.74 feet, in cold room 02 Nos condensor unit (1 No working and 1 No standby) fitted outside the building with suitable stand/standard bracket/platform and 2 Nos indoor (cooling coil) unit (1 No working & 1 No stand by) fitted inside the cold room with necessary clamps/bracket with proper drain tray including drain pipe upto out side all as per manufacturer specification suitable for temperature upto -20°C and laying of refrigerant pipes and with necessary initial gas charging of refrigerant R-404A including pre wired control panel with single phase preventer ,Overload relay, Surge protection relay and necessary cabling from main panel to new control panel and indoor unit to outdoor unit complete all as specified and as directed including with Supply and install cold room of size 17.77x12.62x7.74 feet with 100 mm PUF insulation for wall & ceiling with pre painted stainless steel inside and PP outside (PP/PP) including manual type swing door with 34x78 inches of (Item 1.00 Contd.../-)
(Item 1.00 Contd.../-) thickness 100 mm PP/PP clear opening with accessories and anti condensation door heater ,PAD Lock system, Posi seal closure, human safety release knob with normal opening with lock& key arrangement including with leveling of floor ,grouting of cold room & fixing of aluminium chequered Plate of 3mm thick in cold room floor area over 19 mm thick with marine plywood base support of suitable size to cold room fixing with necessary aluminium flat strip of size 25x3mm at joints, fittings self threaded bolts, screws etc provision of lighting, hooter with switches complete details comprising of the following all as specified and as directed. (a) Ambient temperature --41° C (b) Room temperature - (-18 to -20 ° C) (c) Product to be stored-Meat & Fish (d) Product entering temperature - (-20°C) (e) Pull down time --18 Hours (f) BTU designed --20000 BTU/Hr x 02 Nos (g) Refrigerant --R-404A ( non CFC-HCFC refrigerant) (Item 1.00 Contd.../-)
(Item 1.00 Contd.../-) (h) Digital Temperature indicator -1 No (j) System Type --Split type air cooled (K) Compressor type --Scroll/reciprocating hermetically sealed unit 3 Phase 440 V 50 hz of suitable capacity including control panel (l) Incoming product quantity - 1000 Kg/ Day Make-BlueStar;Voltas,Carrier Note : (i) Cost of standard bracket /stand/platform and necessary piping and drain trap upto outside of building shall be deemed to be included in the quote rate. (ii) Electricity for testing of item shall be issued free of cost by the department. (iii)0-0 Level has to be provided inside the cold room
Supply & Fix vertical type TPN DB double door, 200 amps rated busbar for provision of MCCB as incomer & MCB as out going 4 way. Make Havells or Equivalent in Legrand, L&T Note: MCCB & MCB will be measured separately under relevant items.
Supply & fix MCB TPN 32 amps 10 KA 415 Volts (for each cold room 2 running & 1 Standby) all as specified and as directed. Make Havells or Equivalent in Legrand, L&T
Supply & fix 3 Pole MCCB 100 Amp 50 Hz 415 V with rupturing capacity 25 KA suitable for isolation including enclosure complete all as directed.
Material & labour for sub main wiring of size 4x10 sqmm along with earth wire 2x10 sqmm PVC cable single core conductor in Casing caping all as specified and directed.
Material & labour for Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out for soft & loose soil all as directed.
Material & labour for Excavating in post holes (or similar holes) each not exceeding 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm for soft/loose soil all as specified and as directed.
Supply & Fix Tubes, 'medium grade' galvanised iron with all fitting and fixed complete to walls and ceilings or laid in floors of size 80 MM dia bore
Material & labour for Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) of Rolled mild steel in Fe 410 -W(Gde- E- 250) quality- A complete all as directed.
Supply & fix prepainted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
Material & labour for Hand packing (any thickness) at back of walls over arches etc. and raising (or lowering) to the required level Broken stone or boulders complete all as directed.
Material & labour for Cement concrete in foundations, filling and mass concrete of grade 1:4:8 D2 type 40 mm graded stone aggregate all as directed.
Material & labour for 50mm thick Precast cement concrete type B-1, 1:2:4 (20mm graded stone aggregate) slab flooring, bedded and jointed in cement mortar 1:6 and pointed in cement mortar 1:3 complete all as directed.
Supply & fix for Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, not exceeding 5cm long of size 11 to 15 mm dia neck all as directed.
Material & labour, Earthing complete with copper plate electrode of size 60cm x 60 cm x 3.15mm thick buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of plate not less than 1.5m below normal Ground Level connected to copper strip 20X3 mm as earth lead connected by means of bolts, nuts, washers and check nuts made out of galvanised iron or steel all as shown on electrical plate No. 5 of SSR Part-I connected to main board/distribution board complete all as specified and directed. Note No.1: The unit rate shall also include for earth work in hard/dense soil, PCC (1:3:6) type C1 chamber, RCC M-25 (design mix) cover 50 mm thick reinforced with 8 mm dia CTD bars @ 150 mm c/c both ways, funnel with watering pipe 20 mm dia medium grade, GI protection pipe medium grade 40 mm dia and wire mesh complete in addition to item No. 1(a) to (e) of preamble (notes) under sub-heading earthing, specified on Sl. page No.347 of SSR Part-II. Note No.2: Earthing lead beyond 7.5 m will be measured and paid separately.
Dismantling of old coldroom by removing all connections carefully , making into scrap, removing from site, shifting to MES store yard by own vehicle as directed by Engr-in-charge and making space for provision of cold room all as specified.
SRI HARSHITA ELECTRICALS
KML CONSTRUCTION
M/s Electrotech
EVEREST COOLING WORKS
M/s Karbhagam Sales Agency
kakolil trade agencies
MGP Enterprises
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .