| 1 | L1₹1.9 CrAccepted-AOC NO 9 6 203 1 G2 DURGA BHAVANI NAGAR CHAMPAPET HYDERABAD 500059 | HYDERABAD | TELANGANA | 500059 | ₹1.9 Cr | L1 | Accepted-AOC Lowest and reasonable. |
| 2 | L2₹2.0 Cr+₹3.6 L (1.86%)Rejected-Finance | ₹2.0 Cr+₹3.6 L (1.86%) | L2 | Rejected-Finance Other than lowest. |
| 3 | L3₹2.0 Cr+₹7.5 L (3.85%)Rejected-Finance | ₹2.0 Cr+₹7.5 L (3.85%) | L3 | Rejected-Finance Other than lowest. |
| 4 | L4₹2.0 Cr+₹8.6 L (4.43%)Rejected-Finance 15 HOSHIYAR SINGH PARK KIRBY PLACE DELHI CANTT 110010 | NEW DELHI | DELHI | 110010 | ₹2.0 Cr+₹8.6 L (4.43%) | L4 | Rejected-Finance Other than lowest. |
| 5 | L5₹2.2 Cr+₹24.6 L (12.7%)Rejected-Finance FLAT NO 101 UGF FRONT LHS RZ B 49A KAILASHPURI PALAM COLONY NEW DELHI 110045 | SOUTH WEST | DELHI | 110045 | ₹2.2 Cr+₹24.6 L (12.7%) | L5 | Rejected-Finance Other than lowest. |
Tender Value
₹2.3 Cr
EMD Value
₹3.0 L
Closing Date
23 Sept 2022, 6:00 pmClosed
Chief Engr, Delhi Zone
HQ Chief Engr Delhi Zone Delhi Cantt-10
STRUCTURAL REHABILITATION, WATER PROOFING TREATMENT AND CONSEQUENTIAL REPAIR WORKS OF BLDG NOS P-10 AND P-16 OF 19 BIHAR UNDER AGE B/R-I OF GE (NORTH) DELHI CANTT-10
2022_MES_528103_1
CEDZ/TOKEN-40 OF 2022
Open Tender
Civil Works
Item Rate
180 days
Delhi Cantt
As per Tender Documents
9 documents required · 9 mandatory
₹2,000
GE (North)
₹3.0 L
Yes
3 Oct 2022
2 Jun 2022
26 Sept 2022
2 Jun 2022
23 Sept 2022
9 Sept 2022
Amount
Dismantling of brick tiles, terracing tiles, single layer from roof laid, bedded and pointed in any mortar complete all as specified & directed.
Demolition of Mud in roofs, any thickness, including plastering and leeping without disturbing RCC roof slab using steel props for support to slab or beam etc (whether full thickness removed or only a part thereof) complete all as specified and directed.
Demolition of reinforced cement concrete as in roofs, floors, (other than ground floors), beams, staircases, landing, chajjas and similar suspended work or (reinforcement cut as required to facilatate demolition) of any description and in any position not otherwise specially provided complete all as specified and directed.
Demolition of cement concrete (unreinforced) of any description and in any position not specifically provided for complete all as specified and directed.
Taking down chowkhats or frames n.exc 1.50 sqm with shutters (without taking off shutters from the frames) complete all as specified and directed.
Taking down chowkhats of frames exc 1.50 sqm but n. exc 4.0 sqm with shutters (without taking off shutters from the frames) complete all as specified and directed.
Taking down shutters of any description area of each shutter n.exc 2.00 Sqm each and refixing in same opening after easing and adjusting complete all as specified and directed. (Note consumable item to measured in respective items)
M&L for Preventive treatment against the danger of carbonation in exposed faces of wall:- (i) Cleaning existing surfaces of RCC members and making surface free of loose material, oil, grease etc. by vigorous wire brushing including light grit blasting where necessary as recommended by Engr-in-charge. (ii) Further, cleaning using biocide(as recommended by manufacturer) to ensure that surface is free of algae and fungus and no trace of paint (any type) left out. Sand blasting to be done to remove trace of paint. (iii) Cleaned surface to be allowed to dry. (iv) Spray a coat of primer (as recommended by manufacturer) over dry cleaned surface as required prior to final finish. Primer shall be diluted in proposition 2:1 with mineral turpentine. After application, primer shall be allowed to dry for 03 hours or as directed. (v) Apply a coat of neat Aliphatic Acrylic anti-carbonation (ACC) over the primed surface with air / spray gun at nominal rate of 3.5 ltrs per Sqm as recommended by manufacturer. (vi) Apply a more coat of Aliphatic Acrylic anti-carbonation (ACC) after 5-6 hours as recommended by manufacturer complete all as specified and directed.
M&L for followings :- (i) Removing plaster & finishes all around the coloumns, slabs & beams (on all four sidescription of column to full height , three sidescription of beam to entire span & bottom of slab to area as directed) (ii) After cleaning gently removing cover concrete using pneumatic/electric chipper or any other approved tool in entire portion of structural member (removal of cover concrete shall be done to an extent when reinforcement is visible) (iii) Removal of cover concrete with under cutting of up to a depth of 20mm beyond reinforcement around full circumference & full length of bar where directed. (concrete shall be stripped to an extent concrete substrate is exposed) (iv) Cleaning exposed concrete substrate by using water jet. (v) Removing visible rust along the length of reinforcement using hand tools as approved. (The Engr-in-charge may order sand blasting if rust is approved) (vi) Any other work as directed by Engr-in-charge to present clean surface for determination of type of repair to be carried out complete all as specified and directed.
M&L for providing rust proof /anti corrosive treatment to bars :- (i) cleaning of all exposed bars (new & old) alround (ii) Apply a single coat of Alkaline rust converting primer on alround bars new & old as recommended by the manufactuer (iii) Apply two coats of Epoxy phenolic anti corrosive protective coat on bars alround new & old as recommended by the manufactuer. Note : Anti corrosive treatment shall be continuous espcially in the regions where pitting, imperfections, etc were present on the surface of the bars. It is important that the rear portions of re bars (those towards the concrete substrate) should not be left without coating.
M&L for providing PMM (Polymer modified cementitious mortar) :- (i) Dry sub strate surface and free of debris & dust (ii) Applying Epoxy bond coat on the sound substrate using approved spray machine & ensuring that no pin holes are visible.(In case pin holes are still visible after a coat, a second coat shall be applied to ensure absence of pin holes). (iii) Immediately after application of epoxy bond coat as above apply PMM (Polymer modified cementitious mortar) of 25 mm thickness. Note:- Application of PMM shall be preferably be in coats of appx 10mm thickness. PMM work shall be executed in fairely rapid successions so as entire work is completed with in 30 mins). PMM shall be pre packed ready to use. (iv) PMM surface to be moist cured for three days followed by air curing in temperature as recommended by manufactuer complete all as specified and directed.
M&L for treatement of cracks found in the core concrete :- (i) Opening of crack by making a ' V' notch/groove of size 12mm x 12mm over the entire length of the crack as identified by the Engr-in-charge. (ii) cleaning ' v' notch/groove of all dust/debris/loose material (iii) Drilling hole of 16mm dia and about 40mm deep along the length of crack @ (300 mm c/c or thickness of structural member whichever is less) Note : In case length of crack is found less than 300 mm then min 2 holes shall be drilled. (iv) Inserting 12 mm dia flexible PVC one way injection nipple in the hole drilled above and fixing the nipple with the help of fast setting epoxy putty. (v) Seal the surface around the nipple and the area of crack between successive nipples polymer modified mortar to ensure that there is no leakage from any gap. (vi) Allow the polymer modified mortar to cure for 24 hours and ensure that firmly fixed in postion. (Item contd. as 12.01...)
(vii) Cleaning nipple one by one commencin from the top to bottom in case of column and one by one in alternate direction incase of beam/slab using blow compressed air followed by water injection. An Ensuring that there is no obstruction in free flow of grouting materials complete all as specified and directed. (viii) Injecting " resin with very low viscosity monomer by mixing resin and hardener in proportions recommended by manufacturer by using injection gun equipped with pressure gauge & valves for controlling of flow of compressed air & resin. Note:- pressure shall be in the range of 1-2 kg/Sqm and shall be done in nipples one by one as per order recommended by manufacturer. Mixing of resin and hardenere shall be mixed in small quantities so as it is consumed with in 30 minutes. Before use mixer shall be stirred thoroughly. (ix) Allow entire effected surface to cure for 24 hours. (x) cutting out projected parts of the nipple & seal the hole in the nipple with epoxy putty as recommended by manufacturer. (xi) cleaning exposed surface complete all as specified and directed.
S&F 12mm dia steel sheer connector in grid pattern in between old core and new concrete as wherever directed by Engr-in-charge and as specifed by manufactuer including drilling hole of depth of 100 mm and chemical anchoring with pure epoxy resin anchoring complete all as specified and directed. (Note:- The cost of drilling hole &chemical anchoring with epoxy resin is inclueded in this item)
M&L for Providing & Pouring Micro concreting M-40 grade :- (i) Dry concrete substrate surface and free of debris & dust (ii) Applying Epoxy bond coat on the sound concrete substrate using approved spray machine & ensuring that no pin holes are visible. (In case pin holes are still visible after a coat, a second coat shall be applied to ensure absence of pin holes). (iii) Immediately after application of epoxy bond coat as above pour Micro concreting M40 grade using approved mixing machines/pumping under pressure via approved pneumatic pump at the locations to be repaired in RCC beams & columns etc,. Adding of aggregates will be permitted only as per manufacturer’s recommendation without compromising the strength. The rate shall include cost of all materials (except re-bar) labour charges for demolition of the column and beam, chajja, mixing, pouring concrete, cost of tools, lead & lift of materials, transportation etc., to carry out the complete work complete all as specified and directed. Note : The cost of micro concrete M-40 grade & Epoxy bond coat is inclueded in this item.
M&L for Drilling & chemical anchoring of new rebars/stirrups :- (i) Drilling in to the sound RCC members for anchoring of rebars/stirrups as directed, the dia of hole to be match with dia of rebar & length of drilling as under :- 8 mm dia bar - drilling length 80 to 100 mm Note : Anchoring of new re-bars of any dia as directed in to the sound RCC members as directed using pure epoxy resin anchoring mortar with appropriate diameter of drilling of holes as mentioned above for proper bonding into the concrete etc., complete all as specified and directed. Note:- The cost of drilling hole & chemical anchoring with epoxy resin is inclueded in this item
M&L for Drilling & chemical anchoring of new rebars/stirrups :- (i) Drilling in to the sound RCC members for anchoring of rebars/stirrups as directed, the dia of hole to be match with dia of rebar & length of drilling as under :- 16 & 20 mm dia bar - drilling length 160 to 180 mm Note:- Anchoring of new re-bars of any dia as directed in to the sound RCC members as directed using pure epoxy resin anchoring mortar with appropriate diameter of drilling of holes as mentioned above for proper bonding into the concrete etc., complete all specified and directed. (The cost of drilling hole & chemical anchoring with epoxy resin is inclueded in this item)
M&L for use & waste of form work using steel sheets , steel bracing, propping etc around structural members where micro concreting to be done and keeping form work in position till required specified period complete all as specified and directed. Note:- Form work shall be 100% leak proof. For purpose of payment area in touch with concrete shall be measured.
S&F for strengthening existing reinforcement by use of mild steel bars of any dia , cut to length, bent to shape required, including cranking, bending spirally and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for chipping of spalled and loose concrete and cleaning rust from re-inforcement by sand brushing scrubing down concrete surfaces with wire brushes cleaning with water allowed to dry applying a layer of zinc rich epoxy primer as antirust on all exposed reinforcement followed by a layer of bonding coat of a layer of epoxy adehessive on complete exposed surfaces of concrete and provide guniting in two layers over steel welded mesh 2 mm dia of wire and total aperture 75 mm, thickness of gunite n.exc 25 mm thick (average thickness) using cement mortar 1 :3 with OPC 43 grade cement mixed with polycrete admixture @ 2 % by wight of cement or as per manufactures instructions and finally applying cement plaster over gunite surfaces of required thickness to give an even uniform and smooth finish conforming to proper Geometrics in cement mortar 1:4 to match with the existing surface as in side and soffits of slabs,chajjas,fins,facias ,parapets ,columns and beams etc complete including necessary scaffolding ,shuttering necessary chased to brick work or RCC members at any height upto four storey buildings incl removing of small trees shrubs etc all as specified(Note: steel welded mesh to be welded with the existing reinforcement. The cost of welded meshis to be welded with the existing re-inforcement is deemed to be included in the quoted rate complete all as specified and directed.
M&L for providing precast cement concrete in window or door cills lintels bressumers, steps quoin blocks ( for use with masonry) string coarse cooping, post column boundary pillars set in cement mortar 1:4 complete with joint match used in RCC Jali frame in opening etc complete all as specified and directed.
M&L for Reinforcement cement concrete (design mix) in M-25 using 20mm graded stone aggregate as in columns pillars piers posts and struts etc complete all as specified and directed.
M&L for Reinforcement cement concrete (design mix) in M-25 using 20mm graded stone aggregate as in beams, cantilevers bressummers, lintels over 1.5m span in cluding taking down/dismantling from old position complete all as specified and directed.
M&L for Reinforced cement concrete (design mix) in M-25 using 20 mm graded stone aggregate in chajjas, shelf complete all as specified and directed. (Note:- reinforcement to be measured separately).
M&L Reinforced cement concrete (design mix) in M-25 using 20 mm graded stone aggregate in Slabs supported on walls,beams and columns in floors,roofs, landings, balconies,canopies, deck slabs and in shelves and the like complete all as specified and directed. (Note:- reinforcement to be measured separately).
M&L Reinforced cement concrete (design mix) in M-25 using 20 mm graded stone aggregate as in Fins, ascias, louvres, parapets, and railings exc 60cm in height, newels, balustrade and the like complete all as specified and directed.
Mild steel TMT bars 10 mm dia and over as reinforcement for concrete, cut to length, bent to shape required, including cranking,hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
Mild steel TMT bars 6 to 8 mm dia as reinforcement for concrete, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
All as per item No 27 above but 5 mm dia and over upto 10 mm dia in stirrups, spacers and binders.
M&L for formwork to chullah hoods, chajjas, throughs and similar items including edges complete all as specified and directed.
M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc, also splays between floors and beams, etc. complete all as specified and directed.
M&L for formwork to sides and soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; n. exc. 200 mm thick (Horizontal or slopping) and similar works rough finished surfaces of concrete complete all as specified and directed.
M&L for formwork to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and directed.
M&L Water proofing treatment walls of bathroom consisting of the following operation including demolition/taking down old treatment :- (i) Cleaning of surfaces by wire brushing brooming removing dust particles (ii) Filling of all brick joints with cement mortar 1:4 (iii) Applying a coat of cementitious water proofing membrane. (iv) Applying fiber mesh setting with SBR Latex. (v) Final coating with cementitious water proofing membrane and sprinking of sand (vi) After the surface dried, plaster the surface with 15 mm thick plaster in CM 1:4 including finishing even and smooth using extra cement. (vii) Making hole for fixing of spout pipe etc as per site requirement and making good complete as specified & directed.
M&L Water proofing treatment on sunken floor consisting of the following operation including demolition/taking down old treatment :- (i) Cleaning of surfaces by wire brushing brooming removing dust particles (ii) M&L PCC 1:2:4 type (B0) using 12.5 mm graded crushed stone aggregate 50 mm thick, finishing the surface even and smooth without using extra cement (iii) Applying a coat of cementitious water proofing membrane (iv) Applying fibe mesh setting with SBR Latex. (v) Final coating with cementitious water proofing membrane and sprinking of sand (vi) After the surface dried, screeding the surface with 15mm thick screed in CM 1:4 including finishing even and smooth using extra cement.
M&L for broken lean concrete 1:5:10 with broken brick aggregate in sunken of gauge n exc 63mm deposited spread and levelled in layers n exc 15 cm thick hand rammed to a true surface complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tile s to store and rubbish off the premises complete all as specified and directed.
Roughening surfaces of old concrete floor by picking sweeping clean and washing down with water to remove dust, etc complete all as specified and directed.
M&L for non skid ceramic coloured tiles of 8 to 10mm thick, of approved shade, joint free area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm in floors etc set and jointed in neat cement slurry and pointed in coloured cement. over and including screed bed or bedding layers of cement mortars 15 mm thick in CM 1:6 complete all as specified and directed.
All as per item No 38 above but as in vertical surfaces such as skirting/ dado over and including 10 mm thick rendering in CM 1:4 ditto.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick joint free area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in coloured cement over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed.
M&L glazed (DVT) colour and shed as approved in vertical surface size of each tile exc 0.15 but n.exc 0.18 Sqm set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface over and including 10mm thick rendering in CM 1:4 and finished rough complete all as specified and directed.
Demolition of stone slabs and tiles of any description or thickness in floors aprons etc laid bedded and pointed in any mortar complete all as specified and directed.
M&L for 75mm thick cement concrete type C-2 1:3:6 (using 40mm graded crushed stone aggregate) as in sub base to receive stone slab and pavement complete all as specified and directed.
M&L 18 to 20 mm thick machine cut Kota stone slab mirror polishing/diamond polishing by mechanical means and using carborandum stone of 0 unit to achive mirror finished surface as in flooring over and including 15mm thick screed bed in CM 1:6, laid over cement slurry @ 3 Kg/Sqm and jointed with grey cement slurry mixed with pigment to match with shade of slab including molding the edge of slab complete all as specified and directed. (Note:- The size of Kota stone slab shall not less than 550 mm x 550 mm cut size in flooring and full length single piece in steps, except the location where the balance portion remain less than size as specified above).
M&L 20 to 25 mm thick machine cut Kota stone slab polishing/diamond polishing by mechanical means and using carborandum stone of 0 unit to achive mirror finished surface as in riser or vertical surface over and including 10 mm thick rendering in CM 1:4, and jointed with grey cement slurry mixed with pigment to match with shade of slab including molding the edge where as specified and directed. (Note:- The size of Kota stone slab shall not less than 550 mm x 550 mm cut size as in flooring and full length single piece in steps, except the location where the balance portion remain less than size as specified above).
All as per item No 44 & 45 above but except stone slab ditto.
M&L for Machine cut makrana white marble 18-20 mm thick in flooring as in border in any pattern over 15 mm cement screed bed in CM 1:6 jointed and pointed with white cement slurry including mirror polishing/diamond polishing using carborandum stone of 0 unit including rubbing & treating the surface complete all as specified and directed.
M&L green marble slab 18-20mm thick machine cut and polished of approved colour (Udaipur Green with Granite polish) including setting and jointing in neat cement slurry and pointed in coloured cement to match the serfaces of marble over and including 15mm thick screed bed in CM 1:6 on cooking plateform including moulding and polishing the edges etc complete all as specified and directed.
M&L Granite 18-20 mm thick, colour as approved (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms or making hole for fix in oveal shape for fixing of wash hand basin and like in CM 1:4 including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shed of granite over and including 15mm thick screed bed in CM 1:6 including moulding and polishing the edges complete all as specified and directed.
M&L Granite 18-20mm thick, colour as approved ( of any type) work (table rubbed and polished) in for wall lining (veneering to wall) 12 mm thick in cement mortar (1:3) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shed of granite including moulding and polishing the edges etc complete.
Excavation in post hole or similar holes each n. exc 0.50 Cum in hard/dense soil and getting out, returning, filling in, ramming earth or broken rubble mixed earth around, in layers n. exc 25 cm complete all as specified and directed.
S&F steel work in tubular trusses Fe 410-W (Gde-E-250) quality A including special shaped washer etc. Complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St-240 complete all as specified and directed.
S&F plate girder or single stanchions, Fe-410-W (Gde-E-250) built up of one beam or channel section with flange plates, caps bases. Splices, angle brackets cleats and other connections complete all as specified and directed.
S&F plates Fe-290 (Gde E-165) (plain or chequered) channels, square cut or notched (Ordinary and counter sunk) forming holes, without any attachment.
S&F for steel gate ornamental type made of tubular section, grill work including holdfast, 2x pintels hinges, stoppers, bushes, and all as CI decorative pieces, locking arrangement etc complete all as specified and directed.
Taking down steel gates or steel door shutters area n exc . 3.00 Sqm each and refixing in same opening after repair with 2 Nos pintel hines fixed to wall and door shutters after necessary repair and make it functional complete all as specified and directed.
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated /semi corrugated steel sheet 0.50mm thick of any colour as approved, having tensile strength of 550 MPa as in roof covering/cladding to wall, fixed with self tapping screws to MS framed, roof at any slope, complete all as specified and directed.
S&F Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.45mm thick of any colour as approved having tensile strength of 550 MPa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F false ceiling with semi perforated 12mm thick micro tegular edged at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of size 595x595mm of approved texture, design and pattern having moisture content less than 2% humidity resistance of 99% NRC 0.50 to 0.75 as per IS 8225:1987, Non-combustible as per BS 475 (part-4) -1970 and light Code Description unit rate No 429 Sub Head:26.0 NEW TECHNOLOGIES AND MATERIAL reflectance of 85% minimum to be laid in true horizontal level suspended on interlocking metel T-Grid of hot dipped galvanised iron section of 0.33mm thick (galvanised @ 120 grams over sqm including boh sides) comprising of main-T runners of size 15x32mm of length 3000mm, cross T of size 15x32 of length 1200mm and secondry intermediate cross T of size 15x32 of length 600 mm to form grid module of size 600x600mm suspended from ceiling using galvanised mild steel items (galvanising @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm length and L shape level adjuster of size 85x25x2mm, Galvanised iron perimeter wall angle of size 24x24x0.40mm of length 3000mm to be fixed on perimeter wall/ partition with the help of plastic rawl pluhs at 450mm centre to centre and 40mm long dry wall screws complete all as specified and directed by Eingineer-in-Charge.
Dismantling boarding any description fixed in any position, and any thickness complete all as specified and directed.
S&F 5 mm thick prelam PVC sheet in strips & channel feathered at the edges for fixing on Solild PVC wall Lining Insulated PVC Wall Lining, and Solid PVC partitioins inclusive of solvent cement and fixing at site complete all as specified and directed.
S&F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC frame complete all as specified and directed.
S&F factory made three track UPVC sliding windows white in colour or as approved made of extruded profiles with wall thickness of 2.3mm (+/- 0.20mm) Windows profiles with hollows section with multichamber. Frame size (88mmx52mm), Sliding sash (42mm x 67mm), sliding mesh sash (42mmx57mm), sliding interlock(one vertical length in each shutter) 45.5mmx28mm), glazing bead (24.5mmx16mm) will be mitered cut and fusion welded at all coeners, including drilling of holes for fixing of hardware and drainage of wateretc, making arrangement for fixing of hardware, EPDM, gasket, 1.2+/-0.20 mm thick galvanised steelframe (30mmx28mm) 2 Nos sliding sash (30mmx18mm), sliding mesh (26mmx10mm), profile to be inserted in required profile frame will be fixed to the wall with 8mm x 100mm long fastener hardware, (Touch lock of zinc alloyed (white powder coated), steel roller system stainless steel wire 0.36mm nominal dia of wire and average width of aperture 1.40mm, aluminium grill and required accessories complete all as specified and directed. Note:- The unit rate quoted by contractor includes all connected accessories i.e. wire mesh and hard wares etc.
S&F casement windows with net & MS Grill single or multi shutter turn window are made out of UPVC multi-cavity frames sections of 60x60x2.5mm suitably reinforced and double mult-shutters division are made by using sash mullion having 50x64x2.5mm multi-cavity UPVC section, suitably reinforced with GI and shutters are made out of 50x85x2.5mm UPVC section, reinforced and welded in corners with EDPM gaskets provision for glass and for air tight at frames and outer side of shutter with single glaze window shutters using suitable glass bead with perfect hardware like hinges handles, stays etc complete. Mosquito mesh shutter is made out of UPC extruded section of 61x27x2mm with GI channel of 1.2mm thick, welded in corners. Stainless steel wire mesh (Mosquito net) to be fitted in shutter with proper required accessories like hinges, MS grill of 12mm round or square bar are inserted in main frameas guard bar & screwed by hidden screwing system with powder coating and filled the gap between wall and frame with weather proof silicon sealant over backer rod of required size and of approved quality etc complete all as specified and directed. Note:- Glazed shutters float glass thickness not less than 4.00 mm and wiremes shutter with stainless steel wire mesh 0.36 mm dia with aperture 1.4 mm and MS grill shall also be deemed included in quoted rates and no extra payment will be made to the contractor.
S&F UPVC ventilators made out of UPVC multi-cavity frames sections of 60x60x2.5 mm UPVC section, reinforced and welded in corners with TPE gaskets provision for glass and for air tight at frames and outer side of shutter with single glaze window shutters using suitable glass bead with perfect hardware like hinges, handles, stays etc complete. with MS grill of 12mm thick round/square shape bar duly painted with oil paint over a coat of red oxide are fabricated as per manufactruer and installed in UPVC frame section of 35x35x2 mm by drilling and surveying system filled the gap between wall and frame with weather proof silicon sealant over backer rod of required size and of approved quality complete all as specified and directed. Note:- The unit rate quoted by contractor included glass pan and stainless steel wire mesh, and MS Grill etc
S&F roll forming GI ECO 4000 series double shutter (glazed shutter and mesh shutters) steel windows and ventilators with guard bars, fabricated from roll formed sections made galvanized steel colour coated/powder coated sections including 4mm thick plain glass pan in glazing for glazed shutter and stainless steel wire cloth 0.56 mm nominal dia of wire and average width of aperature 1.18 mm complete for mesh shutters, including two coat of synthetic enamel paint over a coat of red oxide on guard bar, all fitting and fixtures all as specified (Drg as CEDZ TD No 289).
S&F roller blinds premium korean fabric/zebra roller blinds or as approved to windows/opening including top and bottom frame/rail complete all as specified and directed.
S&F powder coated aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and directed.
S&F powder coated of any colour aluminium door shutters, aluminium section weighing 0.55 kg/m incuding necessary joining cleats, glazing clips, ruber neoprene packing handles 2 Nos, tower bolt in each door shutter, hinges powder coated aluminum snap beading screws etc, complete all as specified and directed.
S&F powder coated of any colour aluminium window and ventilator shuttrs, fixed type without sash bar, aluminium section weighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber packing anodised aluminium snap beading screws etc complete all as specified and directed.
S&F Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass other parts made of mild steel heavy duty complete all as specified and directed.
S&F Door closer hydraulically regulated, Aluminium (Die cast) body designation No 3, universal type suitable for door shutters of 851mm to 1000 mm width and of weight between 61 to 80 kg complete all as specified and directed.
S&F 4.00 mm thick sheet glass pan ordinary quality and glazing with rubber beading and aluminium glazing clip/patti area n.exc 0.5 Sqm each pan complete all as specified and directed.
S&F 4.00 mm thick figured glass, pin head type glass pan ordinary quality and glazing with rubber beading and aluminium glazing clip/patti area n.exc 0.5 Sqm each pan complete all as specified and directed.
S&F 6.30 mm thick sheet glass pan, (exceeding area 0.50 Sqm each) ordinary quality and glazing with rubber beading and aluminium glazing clip/patti all as specified and directed.
M&L for providing precast cement concrete louvers and jallies, 50mm thick (measured solid), including all mouldings but excluding frame (Pre cast frame shall be measured separately.
Demolition of brick work or stone builder masonry, built in cement or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and directed.
M&L Brickwork with subclass 'B' Brick straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and directed.
All as per item No 78 above but except brick complete.
M&L for brickwork with subclass 'B' bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 all as specified and directed.
Taking down existing cement plaster including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed.
M&L for ready mix plaster of 15mm thick on brick or conc surfaces in wall incl necessary cement slurry with builk density 1.40 to 1.70 kg, water ratio 17 to 19% by weight & compressive strength as per IS 4031 part 6 applied as per manufacturer complete all as specified and directed.
M&L for Rendering 15mm thick in cement mortar 1:6 on faces of brick work or concrete surfaces, finished fair and even and smooth without extra cement complete all as specified and directed.
M&L for Rendering 5 mm thick in cement mortar 1:3 on concrete surfaces in ceiling, finished fair & even complete all as specified and directed.
M&L for washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 (1 cement : 4 coarse stone dust) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10mm nominal size) white cement in place of ordinary cement to be used in the work, panels with groove all around as per approved pattern including scrubbing and washing the tip layer with brushes and water to expose the stone chippings including necessary scaffoldings complete all as specified (Payment for providing grooves shall be made separately).
M&L for forming groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nails to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete all as specified and directed.
M&L for Preparation of new plastered or unplastered surfaces of ceiling and applying three coats of white wash complete all as spscified and directed.
M&L for complete removal of old treated of ceilling surfaces and preparing of undecorated plastered surfaces of ceiling and applying two coats of white wash complete all as specified and directed.
M&L for Preparation of new plastered surfaces of wall and applying two coats of oil bound distemper white or tinted over and including a coat of wall care putty and chalk whiting on plastered surfaces preparatory to distempering complete all as specified and directed.
M&L for Complete removal of existing treatment, nails etc and preparing old decorated surfaces of wall and applying two coats of Oil Bound distemper over a coat of wall care putty complete all as specified and directed.
M&L for preparation of new plastered surfaces of wall and applying two coat of cement based paint over a coat of cement primer complete all as specified and directed.
M&L for complete removal of existing treatment of wall including cornices etc. by washing, rubbing down and stopping holes, and applying two coats of cement base paint of approved shade complete all as specified and directed.
M&L for finishing walls with acrylic smooth exterior paint of reqired shade; New work (Two or more coat applied @ 1.67 ltr/10Sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 Sqm complete all as specified and directed.
Supply only integral water proofing compound.
Taking up or down steel tubing and connections 15 mm bore complete all as specified and directed.
Taking up or down steel tubing and connections 20 mm bore complete all as specified and directed.
Taking up or down steel tubing and connections 25 mm bore complete all as specified and directed.
S&F Steel water tubes, medium grade, ISI marked, galvanised, 15 mm bore with all fittings, fixed to walls and ceiling or laid in floors complete all as specified and directed.
All as per item No 98 above but 20 mm bore ditto.
All as per item No 98 above but 25 mm bore ditto.
Refixing only old 15 mm dia bore steel water tubing & connection in new or old position fixed to wall, ceiling or laid in floors including necessary cutting & making of new threads for fixing of new fittings such as elbows, tees, sockets, union, reducer, etc as required complete all as specified and directed.
All as per item No 101 above but 20 mm bore ditto.
All as per item No 101 above but 25 mm bore ditto.
Dismantling PVC water tanks of capacity exceeding 250 litres but not exceeding 500 litres including ball valves complete all as specified and directed.
Dismantling PVC water tanks of capacity exceeding 500 litres but not exceeding 1000 litres includng ball valves complete all as specified and directed.
S&F Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) of 500 litres capacity, ISI marked, double layered hoisted and fixed in position including connecting up pipes complete all as specified and directed.
All as per item No 106 above but 1000 litres capacity ditto.
S&F in repair 20 mm Gun-metal, globe or gate valves,with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F in repair 25 mm Gun-metal, globe or gate valves,with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F ball valves, high pressure of PTMT with epoxy coated aluminium rod & high density plastic wall, screwed for iron pipe and fixed for 25 mm bore size (Minimum weight 210gms), complete all as specified and directed.
Cutting chases in brick walls, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, shelves, lintels, etc, and cutting chases for concealed water tubings or conduit wiring, etc and making good, cutting not exceeding 10cm girth complete all as specified and directed.
Demolition/taking down PVC/CI drain/Rain Water Pipe under floor or wall of internal dia 75/100 mm, set in cement mortar/ Bricket complete incl fittings complete all as specified and directed.
S&F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls 75mm bore complete all as specified and directed.
S&F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls 110 mm bore complete all as specified and directed.
S&F PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors, 75 mm bore complete all as specified and directed.
S&F PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors, 110 mm bore complete all as specified and directed.
S&F PVC (SWR) bends any radius, 75 mm bore complete all as specified and directed.
S&F PVC (SWR) bends with access door any radius, 75 mm bore complete all as specified and directed.
S&F PVC (SWR) bends any radius, 110 mm bore complete all as specified and directed.
S&F PVC (SWR) bends with access door any radius, 110 mm bore complete all as specified and directed.
S&F PVC (SWR) junction single (single T), equal or unequal, 75 mm bore complete all as specified and directed.
S&F PVC (SWR) junction single (single T), equal or unequal, with access door 75 mm bore complete all as specified and directed.
S&F PVC (SWR) junction single (single T), equal or unequal, 110 mm bore complete all as specified and directed.
S&F PVC (SWR) junction single (single T), equal or unequal, with access door 110 mm bore complete all as specified and directed.
S&F PVC (SWR) junction single (double T), equal or unequal, with access door 110 mm bore complete all as specified and directed.
S&F PVC (SWR) branch piece, double (double Y) equal or unequal of 110mm bore complete all as specified and directed.
S&F PVC (SWR) vent cowl, 110 mm bore complete all as specified and directed.
S&F in repair Soap Dish Holder complete all as specified and directed.
S&F in repair 75 mm PVC (SWR) floor trap, plain with grating with or without hole including jointing with solvent cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate mix with WPC complete all as specified and as directed.
S&F Glass shelf 600 mm long complete all as specified and directed.
S&F Corner glass shelf (with bracket) complete all as specified and directed.
M&L for writing letters (Block, Roman, Italic or Indian) n exceeding 30 cm high (for writing Bldg No, Name, Rank and Unit of individual officer occupaying the md accn inclluding cost of scaffolding) complete all as specified and directed.
S&F Tubular towel rail of brass chromium plated, 20 mm dia, 'D' type, 60 cm long between flanges complete all as specified and directed.
S&F in repair Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butter fly handle, fancy type, chromium plated, with long shank and cup (concealed type) screwed both ends for iron pipe or for unions 15 mm bore complete all as specified and directed.
S&F in repair of quarter turn bib tap with wall flange for iron pipe of size 15mm bore chromium plated all as specified and directed.
S&F in repairs central hole wash hand basin mixer complete all as specified and directed.
S&F in repair fancy type brass chromium plated shower rose with arm complete all as specified and directed.
S&F in repair 10 litre capacity PVC low level flushing cistern with dual flush type‘ white’ with inlet, float valve including bracket with 32mm dia PVC waste/flush bend pipe appx 600 mm long complete all as specified and directed.
S&F in repair PVC connection pipe 600mm long and15 mm dia with brass fly nut at both ends complete all as specified and directed.
S&F in repair vitreous china squatting pan, ‘Orissa’ pattern, of size 580 mm x 440 mm white with integral foot rest complete including provn of cement concrete bedding and connection to trap, outgoing flushing pipe, anti syphonage pipe etc complete all as specified and directed.
S&F in repair Vitreous china wash down water closet pan (pedestal pattern), white including fixing bolts, flushing cistern and flush pipe connection to trap and to flushing pipe inbend cluding provn of cement concrete beading complete all as specified and directed.
Supply only EWC Seat cover Black/white colour as approved of PVC closed pattern with flat bottom and mild steel chromium plated or aluminised hinging device complete all as specified and directed.
S&F in repair Health faucet (ABS Body) mild steel chromium plated suitable for 15mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect complete all as specified and directed.
S&F in repair vitreous china urinals bowl, half stall flat back large of size white with grating and union for discharge pipe complete including waste coupling provide and fixing plugs bedding urinal against wall in CM 1:2 securing urinal to plugs with and including 60mm long brass screws pointing around urinal back in cement including Urinal spreader complete all as specified and directed.
S&F in repair vitreous china wash basin, snow white of size 550x400x195mm oval shape including 32mm dia chromium plated waste coupling, making good complete all as specified and directed.
S&F in repair Chrome Polished brasss urinal spreader 15mm inlet with fixing stud from alongwith necessary fixing arrangement complete all as specified and directed.
S&F in repair CP Stainless Seel Connection pipe 600mm long pemimum qualilty for Gyser, urianal, WHB etc complete all as specified and directed.
S&F in repair CP Bottal Trap, plug type with wall flange complete all as specified and directed.
S&F in repair CP towel ring complete all as specified and directed.
S&F in repair Chrome Polished Towel Rod fixed to wall complete all as specified and directed.
S&F in repair CP Toilet Paper Holder with cover (Silver) complete all as specified and directed.
M&L for Reinforcement Cement Concrete type B1 1:2:4 (20mm graded stone aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating necessary form work complete all as specified and directed.
M&L cement concrete type C-1, 1:3:6 (using 20mm graded aggregate) as in plinth protection and paving 75mm thick laid in slope finished even and fair without using extra cement incl making joints at every 2.5m and at corner filled with bitumen 85/25 and sand in ratio 1:2 by weight including necessary form work complete all as specified and directed.
S&F 32 mm dia bore Low density polyethylene pipes (LDPE)of pressure rating 6kgf/cm2 fixed complete to walls,ceilings or in floors etc for WHB and sink complete all as specified and directed.
S&F in repair Chromium plated brass angle valve including cp flanges for 15mm bore pipe complete all as specified and directed.
S&F in repair, two way angle valve cock chromium plated brass fancy type including CP flanges bore 15mm complete all as specified and directed.
S&F for aluminium anodized grills with 6 x 5 mm aluminium section having square gap of 50 mm thick with fixing rails of channels 12-15 mm complete all as specified and directed.
M&L for PCC 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) as in hold fasts including necessary use and waste of form work complete all as specified and directed.
S&F mild steel work as in holdfast made out of flat iron 25mmx5mm including necessary welding or fixing nuts and bolts complete all as specified and directed.
M&L preparing steel surfaces and treating small article such as hold fast etc area not exceeding 0.1 Sqm each and treated with tar or coal tar black paint complete all as specified and directed.
S&F second class hard wood Plain, solid, straight chowkats and frames, wrought, ramed rebated on the solid, rounded or chamfered, rafter, purline etc put together with glue pinned at joints complete all as specified and directed.
S&F Solid PVC molded door frame of size 50mm x 95mm made out of 5mm single side prelam PVC sheet used instead of plain colour PVC Sheet suppling & fixing in opening complete all as specified and directed.
S&F Factory Made Solid PVC Moulded Door Shutter with partical board, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded Prelam PVC Sheet on the front face & 2mm Plain colour PVC Sheet on back face, supplying & fixing in frame at site complete all as specified and directed.
S&F 35 mm thick second class hardwood glazed and Skelton factory made door shutters, open rebated and prepared to receive glass/gauze etc divided into squares with plain, chamfered or rounded mitered beads for securing glass/ gauge complete all as specified in SSR Pt I-1991 section 8 clause 8.24 (a) and as directed.
S&F chowkats 2nd class hard wood Plain, framed, panelled shutters 35 mm thick (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers and framing is moulded on solid (for each side) complete all as specified and directed.
M&L Mild steel conforming to Fe 410-0 or Fe 310-0 in framed work such as grills, gratings, ladder, hinges, door frame, desert cooler stand etc with ends of bars shouldered and/or riveted or forged into spikes; framed guard bars; ladders; railings, coolar stand and similar work complete all as specified and directed.
S&F stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm, fixed with stainless steel wire staples beads, tinned tacks to wooden doors shutters complete all as specified and directed.
S&F and fabrication in repair cabinet & wardrobe/ cupboard made out of 18 mm thick PVC board plain sheet including providing cabinet complete all as specified and directed.
S&F and fabrication in repair wardrobe/ cupboard shutters made out of 15-18 mm thick PVC board one side laminated sheets complete all as specified and directed.
S&F magnetic catches with steel body ‘H’ type, fixed to shutter complete all as specified and directed.
S&F 150 mm dia oval shape brass handle cromium plated fancy type polished bright finish complete all as specified and directed.
S&F Continuous (Piano) hinges, brass, 30 mm width of flaps (when open) complete all as specified and directed.
S&F stainless steel acessories suitable for kitchen cabinets as under:-
(a) Stainless steel basket (plain) of size 50cmx37cmx10cm made of 4mm thick S.S. wire approved quality with suitable arrangement for fixing Telescope basket (channel) 11/25 inch length two way extruded MS galvanised over rollers complete all as specified and directed.
(b) Stainless steel thali basket (11-13 division) of size 50cmx37cmx20cm made of 4mm thick S.S. wire approved quality with suitable arrangement for fixing Telescope basket (channel) 18/25 inch length two way extruded MS galvanised over rollers complete all as specified and directed.
(c) Stainless steel plate basket (11-13 division) of size 50cmx37cmx16cm made of 4mm thick S.S wire aproved quality with suitable arrangement for fixing Tele scope basket (channel) 18//25 inch length two way extruded MS galvanised over rollers complete all as specified and directed.
(d) Stainless steel partition basket of size 50cmx37cmx16cm made of 4mm thick S.S. wire approved quality with suitable arrangement for fixing Telescope basket (channel) 18/25 inch length two way extrude MS galvanised over rollers complete all as specified and directed.
(e) Stainless steel cutlary basket of size 50cmx37cmx10cm made of 4mm thick S.S. wire and bottom of S S perforated sheet approved quality with suitable arrangement for fixing Telescope basket (Channel) 18/25 inch length two way extruded MS galvanised over rollers complete all as specified and directed.
(f) Stainless steel basket (plain) of size 50cmx37cmx16cm made of 4mm thick S.S wire approved quality with suitable arrangement for fixing Telescope basket (channel) 18/25 inch length two way extruded MS galvanised over rollers complete all as specified and directed.
(g) Stainless steel bottol full out of size 50cmx40cmx16 cm in two tier made of 4mm thick S.S wire approved quality with suitable arrangement for fixing Telescope basket (channel) 18/25 inch length two way extruded MS galvanised over rollers complete all as specified and directed.
S&F Telescope basket/drawar (channel) 18/25 inch length extruded MS galvanised over rollers complete all as specified and directed.
S&F stainless steel 1mm thick sinks with drainage board made of kitchen or laboratory with plugs, washers and wastes, including bedding in cement mortar including fixing cantilever brackets connecting union to pipe and 32mm dia GI pipe duly painted upto Nihani Trap or Floor trap complete as directed at site, overall size 915mmx460mm bowl size 410mm x 330mm x160mm complete all as specified and directed.
S&F floor door stopper of aluminium alloy body and tongue, anodized with hard drawn steel spring, fixed to floor of size 140 mm complete all as specified and directed.
S&F 100 mm aluminium anodised hasp and staple complete all as specified and directed.
S&F 4 levers brass cupboard locks grade-I, size 65 mm complete all as specified and directed.
S&F 100 mm long aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified and directed.
S&F 150 mm long aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified and directed.
S&F 200 mm long aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified and directed.
S&F 100mm long stainless steel but hinge in PVC door or FRP doors with screws complete all as specified and directed.
S&F butt hinges, 100 mm size medium weight, cold rolled mild steel complete all as specified and directed.
S&F aluminium handles 200 mm size cast type, anodised complete all as specified and directed.
S&F aluminium handles 150 mm size cast type, anodised complete PVC door or FRP doors with screws complete all as specified and directed.
S&F 300 mm mild steel, ordinary rat tail rod pattern spring including roller and roller plate complete all as specified and directed.
S&F 200 mm aluminium alloy, anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast of extruded sections and fixing bolts and sliding bolts of extruded sec or cast aluminium and fixed complete all as specified and directed.
S&F 300 mm mild steel, sliding door bolt plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and directed.
S&F Stainless Steel Cromium Plated tubing of 25 mm dia as in curtain rod fancy type including fancy type CP brabs brackets (wall to wall or flush to wall), with both side end knobs /lattu as approved by GE for securing to curtain rod, fixed in repair complete all as specified and directed.
M&L applying one coats of synthetic enamel paint on old treated wooden surfaces of any description over 10 cm width or girth including preparation of surfaces complete all as specified and directed.
M&L applying two coats of synthetic enamel paint on new wooden surfaces of any description over 10 cm width or girth over a coat of pink primer including preparation of surfaces complete all as specified and directed.
M&L applying one coat of synthetic enamel paint on old treated steel surfaces of any description over 10 cm width or girth including preparation of old painted surfaces complete all as specified and directed.
M&L applying two coats of synthetic enamel paint on new steel surfaces of any description over 10cm width or girth over a coat of red oxide primer including preparation of steel surfaces complete all as specified and directed.
Removing of surplus excavated/demolised materilas to a distance exc 1.5 Km but n.exc 5 Km and deposited where directed at a level n. exc 1.5 m above the starting point complete all as specified and directed.
M&L cutting crack to 'V' groove section in existing roof cleaning out wetting grouting with cement and sand slurry of 1:3 complete all as specified and directed.
M&L PCC 1:2:4 type B0 with 12.5 mm graded stone aggregate with mixing of WPC as in padding over roof slab for making slope on roof top surface complete all as specified and directed.
M&L for 15 mm thick Cement plaster on surfaces of concrete in CM 1:4 on roof surfaces (Over PCC Padding) mixed with WPC complete all as specified and directed. Note : WPC shall be measured and paid separately
M&L for water proofing treatment on roof slab consisting with following operations:- (i) Existing surface shall be cleaned of all dust, fungus, moss and other foreign material etc by using wire brush & dusting, Apply a layer of bituminous primer conforming to IS 3384 @ 0.4 Lit/Sqm on the surface. Laying 3mm thick APP membrane having non-woven polyester matt at core and under surface coated with plastic polythene film over a layer of hot bitumen 85/25 @ 1.20 Kg/Sqm after laying of bituminous primer. Laying shall be done using butane torch maintaining 100mm side overlap & 150mm end overlap, sealling all overlaps complete including treatment at all junctions & corners. The membrane shal be tucked into groove on vertical plane and groove sealed with cement mortar. The treatment shall be provided upto 200mm height above finished floor (Note- The membrane shall have tensile strength of 700N/5cm in longitudinal direction and 450N/5cm in transverse direction at 23 degree celcius, Flow resistance>120 degree celcius, dimensional stability, < 0.5% when tested as per ASTM D 5147. The laying of the membrane shall be done through authorized applicator of the manufacturers' (ii) Again applying hot bitumen 85/25 @ 1.2 Kg per Sqm over water proofing membrane. (iii) Dusting dry sand @ 0.75 Kg per Sqm and applying two coat of silver paint over the membrane. (iv) Prepration of surfaces and applying two coat of bituminous solar reflective aluminium paint @ 0.15 Ltr / Sqm over APP surface.
Excavation in trenches, n exc 1.5 m wide and n exc. 1.5 m in depth for foundation, etc or for shafts, wells cesspits, manholes, pier holes etc n exc 10 Sqm on plan and n exc 1.5 m in depth and getting out in soft / loose soil including old damage lines complete all as specified and directed.
M&L for Reinforced cement concrete (Design Mix) in M-25 as in foundations, including rafts, footings, foundation beams plinth bams, bases for columns etc, basement slabs, under reamed piles and mass concrete complete all as specified and directed.
M&L for flat rough finshed form work to sides of concrete foundations footings bases of columns, rart and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work; vertical or to batter complete all as specified and directed.
M&L for Using telescopic steel props including necessary centring sheet, prop extension scaffolding APS horizontal / vertical ladger pipe channel rod & plate etc all arrangement to support the finish structure up to height 7.00 Mtrs compete all as specified and directed.
Description of Work / Item(s)
Amount
Taking down carefully copper / aluminium point wiring (light / fan socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc for taking credit including making good the disturbed surfaces to match with the existing complete all as specified and directed.
M&L for point wiring with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall on wall including sunk zinc coated pressed steel terminal box of 1.60mm thick with 3mm thick plastic laminated sheet top cover, brass screws, cup washers etc complete all as specified and directed for One light / bell point controlled by one, one way switch 06 Amps complete all as specified and directed.
All as per item No 2 above but one fan point controlled by one, one way switch 06 Amps
All as per item No 2 above but one 3 pin, 06 Amps socket outlet point on independent board controlled by one, one way 06 Amps switch
All as per item No 2 above but one 3 pin, 06 Amps socket outlet point on same board controlled by one, one way 06 Amps switch
All as per item No 2 above but point wiring with 4 Sqmm single core FRLS cables and earth continuity wire of 4 Sq mm single core FRLS cable for one 3 pin 15 Amps socket out let point controlled by one, one way switch on independent board complete all as specified and directed
S&F switch piano flush type, 06 Amps, single pole, one way, 250 volts complete all as specified and directed.
S&F switch piano flush type, 16 Amps, single pole, one way, 250 volts complete all as specified and directed.
S&F socket outlet 2 in 1, 5 pin, 06 Amps, flush type, 250 volts with socket frame complete all as specified and directed.
S&F socket outlet 2 in 1, 3 pin, 06 Amps and 3 pin, 16 Amps, flush type, 250 volts with socket frame complete all as specified and directed.
S&F ceiling fan regulator, stepped type of 0 to 04 rotary steps, electronic, 02 module, humfree, AC, 230 volts, 100 watts incl connection complete all as specified and directed.
S&F ceiling rose, 6 Amps with three equal size terminals incl connection complete all as specified and directed.
S&F surface and wall mounted LED batten 10 watt 2 feet long extruded aluminium housing provided for efficient heat dessipation with polycarbonate diffusser and integrated electronic drive suitable for mirror fittings, all accessories pre-wired including connecting up with twin core flat flexible copper conductor cable of suitable size complete all as specified and directed.
Taking down of existing u/s tube light fitting and S&F on surface and wall mounted LED batten with polycarbonate housing and initigarated electronic drive 20 Watt fixture 4 feet provided for efficient heat dissipation with policorbonate diffuser and integrated electronic driver and all accessories pre-wired including connecting up with twin core flat flexible copper conductor cable of suitable size with connector block complete all as specified and directed.
Taking down of existing u/s security light fitting and supply and fixing energy saving security light fitting of 35 watts LED Versatile pressure die-cast aluminium IP 66 roadway luminaire with high power LED as light source comprising with electronic driver and all accessories pre-wired incl connecting up with PVC insulated copper conductor cable 1.5 Sqmm, 3 core and incl light grade GI tube mounting bracket of suitable size & length, bend to shape and fixed to wall by means of 02 nos. of 40 x 5 mm flat iron clamps, nuts, bolts and washers etc complete all as specified and directed.
S&F exhaust fan, AC, single phase, 230/240 V of size 300mm sweep, metal body, heavy duty, 1400 RPM, double ball bearing with iron louver & shutter and making hole at wall of required size for fixing of fan incl making good disturbed surtaces of wall and taking down old/unsv fan and deposit in E/M store yard complete all as specified and directed.
All as per item No 16 above but 450mm sweep, heavy duty fan ditto.
M&L for sub main wiring with 06 Sqmm nominal cross sectional area, two single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable with and including continuous earth wire of size 6 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable drawing into and including rigid non-metallic PVC concealed conduit of 20 mm dia, medium grade with all conduit accessories and connected to common earth dolly with suitable copper lugs including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing complete all as specified & directed, including taking down old sub main wiring complete all as specified and directed.
All as per item No 18 above but for 02 x 4 Sqmm for phase & neutral and 01 x 4 Sqmm for continuous earth wire complete all as specified and directed.
S&F (in replacement) industrial type SPN enclosure with a two pin and earth plug and socket complete with and including MCB SP, AC, 230 volts of 20 Amps, 'C' curve 10 KA breaking capacity and flush to wall including all cuttings & chases etc in wall and making good to the disturbed surfaces to match the existing complete all as specified and directed.
S&F (in replacement) sheet metal enclosure distribution board, single pole and neutral, AC, 240 volts, 8 way, with 200 Amps rated copper bus bar and metal door with IP - 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified and directed.
S&F (in replacement) sheet metal enclosure distribution board triple pole and neutral (VTPN), AC, 440 volts, 04 ways with 200 Amps rated copper bus bar and metal double door suitable for MCCB 125 amps as incomer and MCB SP as outgoing along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete (Note :- MCCB & MCB SP will be measured seperately)
S&F MCCB 125 amps, 4 Pole, 415 volt, AC, fixed type, with breaking capacity 25 KA suitable for load line/ VTPN DB & connection complete all as specified and directed.
S&F MCB, SP, AC, 240 volts of 10 to 40 Amps capacity "C" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified and directed.
S&F MCB, SPN, AC, 240 volts of 63 Amps capacity "C" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified and directed.
M&L for earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick buried vertically in ground (earth pit not less than 2.25meter deep below ground level) with top edge of the plate not less than 1.5meter below normal ground level steel earth plate connected with GI wire 4 mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15mm bore light grade all as shown in elect plate No 3 on serial page No 497 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipe medium grade 20mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 6mm dia at the rate of 75mm center to center both way with 12mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, Angle iron 40mmx40mmx3mm frame for pit cover including testing on completion complete all as specified and directed.
S&F water heater storage type (geyser), capacity 25 litres, 230 volt, AC, BEE 5 star rated, to be fixed on wall with suitable size of nut/ bolt / fasteners and washers incl making good the disturbed surfaces of wall incl necessary cold and hot water connection with 02 Nos heavy duty connection pipe of SS rope threaded type with brass unions at both ends, 45 cm long, 15mm bore incl taking down & depositing old fan to E/M store complete all as specified and directed.
Taking down ceiling fan any make from ceiling carefully, cleaning to remove any type of sticky dust with cleaning material as required and re-fixing in its original / desired location with necessary connection incl provision of cable from ceiling rose to connector of fan after repairing, greasing, oiling, replacement of minor items such as pins, nut bolts, flexible wire etc incl spray painting with synthetic enamel paint in white colour complete.
S&F ceiling fan complete with three blades, down rod, accessories 230 V, 1200mm sweep, min air delivery 210 CFM, BEE 5 star rated with brushless direct current motor and taking down old/unsv fan and deposit in E/M store yard complete all as specified and directed.
Excavation in trenches in soft/loose soil not exceeding 1.5 mtr wide and exceedidng 1.5 mtr depth for laying of LT UG cable and getting out complete all as specified and directed.
Returning, filling in, trenches with soft/ loose soil including spreading levelling watering and well ramming in layers not exc 25 cm with excavated soil complete all as directed.
Removing surplus spoil to a distance not exc 50 mtr away and depositing where directed at a level n.exc. 1.5 mtr above the starting point complete all as specified.
M&L for sand cushioning for protection of cable with screen wash river sand complete all as specified and directed.
Supply and laying sub class 'B' bricks laid dry and flat across the length of cable for protection of cable complete all as specified and directed.
M&L tubing GI light grade laying for protection of LT under ground cable of size 40mm bore complete all as specified and directed.
Supply and laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sqmm 3.5 core complete all as specified and directed.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .