| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.4 LAdmitted-Finance | ₹4.4 L | L1 | Admitted-Finance |
| 2 | L2₹5.3 L+₹86,039.70 (19.4%)Admitted-Finance | ₹5.3 L+₹86,039.70 (19.4%) | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Sarathy Electricals L2 | 33AAGPP6266P2Z1 L1 |
|---|---|---|---|---|---|
| 1.00 | Dismantling of existing 1.5TR ST type AC unit including dismantling indoor, outdoor units and copper piping, interconnecting wiring, drain pipe etc and handing over to the Exchange in-charge etc as required | 27 | job | 40,500 ₹47,790 | 24,300 ₹28,674 Lowest |
| 2.00 | Dismantling of old faulty 4KVA Wall mounted stabiliser of Split / Window AC units including disconnection and handing over to the Enchange in-charge etc as required | 27 | job | 5,400 ₹6,372 Lowest | 5,400 ₹6,372 Lowest |
| 3.00 | Supplying and fixing of 20A industrial box with Metal clad plug & socket, 1 no 20A SP MCB i/c connections,testing and commissioning etc. as required.(M/s.Standard or SS make) | 30 | job | 72,000 ₹84,960 | 57,000 ₹67,260 Lowest |
| 4.00 | Providing and fixing of 32 mm dia (OD) PVC pipe for disposal of condensate water of the new AC units i/c bends, collars, unions etc. complete as required | 71 | mtr | 21,300 ₹25,134 | 17,395 ₹20,526.1 Lowest |
| 5.00 | Supply and fixing Temperature based, Cyclic Timer for 2 nos AC Units, suitable for operating on 230V 50Hz 1Ph AC supply, including Auto manual Switch for Bypass / override facility, site programmable with provision for setting LOW, Set, High, Temperatures, inbuilt features for rotation of AC units, Switching ON of 2nd unit in case 1st unit is not sufficient or not working, Temperature Sensor with minimum 3Mtrs length cord, Induvidual Potential free contacts for AC units and alrm Extention / Electronic Buzzer complete as per specification etc as reqd. ( Make : Smart Electronics / Model : TIM 2HTA / Relay controllers : Model : SZ-7556-P/SZ-7558P or simillar Superior make) | 10 | job | 1,30,000 ₹1,53,400 | 1,15,000 ₹1,35,700 Lowest |
| 6.00SITC of seqential operation logc along with temparature control for 4 nos 1.5 TR Split AC units with following features. make Smart Electronics/SS make Model :- TIM 4HTAM - SPL | |||||
| 6.10Auto / Manual ON Switch ; Prefixed Timing Cycle ; Digital Temperature Controller with 3 meters long Sensor wire ; 230 VAC Buzzer for ALARM ; | |||||
| 6.2012 way & 8 way Heavy Duty Connectors for wiring ; Size :- 12" x 8" x 4 " | |||||
| 6.30Working of Customized 4 AC Timer :- | |||||
| 6.40Situation 1 :- Room Temp. RT ≤ LOW , 1 Working, 3 Standby ; Situation 2 :- Room Temp. RT ≤ SET , 2 Working, 2 Standby ; | |||||
Tender Value
₹3.9 L
EMD Value
₹7,885
Closing Date
2 Jun 2026, 3:00 pmClosed
EET
EET , BSNL ECIIKellys Chennai
Replacement of Life expired 23 nos1.5TR ST AC units in TXM STR rooms at Mahabalipuram,Perambur,Thiruvanmiyur,uttukotai,MM Nagar,Gummidipoondi,Redhills,ponneri and St.Thomas Mount Exchanges . SW Associated works and Providing Timer
2026_BSNL_278602_1
NIT No 19/EE-T/EC-II/CH/2026-27
Open Tender
Electrical Works
Works
30 days
VariousSTR Stations in Chennai
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
BSNL Chennai Telephones
₹7,885
Yes
4 Jun 2026
23 May 2026
3 Jun 2026
23 May 2026
2 Jun 2026
23 May 2026
23 May 2026 - 2 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Dismantling of existing 1.5TR ST type AC unit including dismantling indoor, outdoor units and copper piping, interconnecting wiring, drain pipe etc and handing over to the Exchange in-charge etc as required | |||||
| 2Dismantling of old faulty 4KVA Wall mounted stabiliser of Split / Window AC units including disconnection and handing over to the Enchange in-charge etc as required | |||||
| 3Supplying and fixing of 20A industrial box with Metal clad plug & socket, 1 no 20A SP MCB i/c connections,testing and commissioning etc. as required.(M/s.Standard or SS make) | |||||
| 4Providing and fixing of 32 mm dia (OD) PVC pipe for disposal of condensate water of the new AC units i/c bends, collars, unions etc. complete as required | |||||
| 5Supply and fixing Temperature based, Cyclic Timer for 2 nos AC Units, suitable for operating on 230V 50Hz 1Ph AC supply, including Auto manual Switch for Bypass / override facility, site programmable with provision for setting LOW, Set, High, Temperatures, inbuilt features for rotation of AC units, Switching ON of 2nd unit in case 1st unit is not sufficient or not working, Temperature Sensor with minimum 3Mtrs length cord, Induvidual Potential free contacts for AC units and alrm Extention / Electronic Buzzer complete as per specification etc as reqd. ( Make : Smart Electronics / Model : TIM 2HTA / Relay controllers : Model : SZ-7556-P/SZ-7558P or simillar Superior make) | |||||
| 6SITC of seqential operation logc along with temparature control for 4 nos 1.5 TR Split AC units with following features. make Smart Electronics/SS make Model :- TIM 4HTAM - SPL | |||||
| 6.1 | Auto / Manual ON Switch ; Prefixed Timing Cycle ; Digital Temperature Controller with 3 meters long Sensor wire ; 230 VAC Buzzer for ALARM ; | - | - | - | - |
| 6.2 | 12 way & 8 way Heavy Duty Connectors for wiring ; Size :- 12" x 8" x 4 " | - | - | - | - |
| 6.3 | Working of Customized 4 AC Timer :- | - | - | - | - |
| 6.4 | Situation 1 :- Room Temp. RT ≤ LOW , 1 Working, 3 Standby ; Situation 2 :- Room Temp. RT ≤ SET , 2 Working, 2 Standby ; | - | - | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.36 MB
BOQ_325255.xls
BOQ • 2.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .