General Manager RSRDC Ltd. Jaipur
Office of the Project Director RSRDC Ltd. Unit-Electrical, Jodhpur. High Court Campus, Near Shatabdi Circle, Jodhpur
Repair and Renovation work Air cooling and Air conditioning work at District Hospital Barmer
2026_RSRDC_560128_1
RSRDC NIT 095/2026-27 (Sl-2)
Open Tender
Electrical Works
Percentage
90 days
Barmer
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
Through RTGS/NEFT/IMPS
₹1.5 L
29 May 2026
18 May 2026
26 May 2026
18 May 2026
25 May 2026
19 May 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply , Installation, Testing and Comissioning of factory assembeled double skin central evaporative cooling plant having specifications as per A, B, C, D, E | 0 | Each | 0 | ₹0 |
| 2 | A. Air washer comprising of 2nos Pre-Filters. First filter shall be 50mm thick Aluminium wiremesh filter & second filter shall be 50 mm thick MERV-8 synthetic media filter with efficiency 90 % down to 10 microns. Both filters to be placed over the common frame. | 0 | Each | 0 | ₹0 |
| 3 | B. Humidification section comprising of Wet pads 200 mm thick impregnated cellulose paper media ( Celdec pads ) with 2 bend PVC eliminator. The End plates of Pad & Eliminator shall be in SS 304 construction. Also, the inner blank offs of Wet section shall be in SS304 construction. | 0 | Each | 0 | ₹0 |
| 4 | C. Fan Section comprising of belt driven, DIDW Backward curved AMCA certified centrifugal fan with maximum air outlet velocity of 10m/s suitable for required cfm at 50 mm static pressure (Total static of the unit shall be verified by the OEM before the design & supply of the units). Fan & Motor should be mounted over Aluminium channel of suitable thickness and should be isolated from the unit's bottom panel by means of Spring isolators. | 0 | Each | 0 | ₹0 |
| 5 | D. TEFC High efficiecny IE-3 class motors as required with pulley, belt , Guard | 0 | Each | 0 | ₹0 |
| 6 | E. The unit shall be fabricated with frame work hollow extruded aluminium profile with 0.80 mm preplasticised GSS on outside and 0.80mm 275gsm plain GSS on inside complete with 25 mm thick CFC free PUF insulation of minimum 40 kg/cum density sandwiched in between inner and outer skins. Unit should have MS powder coated legs to give height to unit's base channel from the floor surface. SS-304 ( 18 g ) Sump, UPVC Internal piping, make up, drain & quick fill and drain connection, Butterfly/Gate valves for pumps, make up, drain & quick fill and drain connections of sump, 2 no. Vertical Pumps of suitable capacity to be placed inside the unit's housing (external pumps are not acceptable) ,Y strainers and necessary fittings, Concrete Blocks / M S stand, anti vibration pads etc.as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . | 0 | Each | 0 | ₹0 |
| 7 | 15000 cfm | 7 | Each | 3,90,000 | ₹27,30,000 |
| 8 | 20000 cfm | 1 | Each | 4,60,000 | ₹4,60,000 |
| 9 | SITC of Wall mounting cubical type Starter panel made out of 1.6 mm thick sheet steel powder coated enclosure designed as per Switchgear OEM type -2 coordination chart and suitable for operation of following cfm range Air Washer's Blower motor, pump comprising of over load protection relay, short circuit & single phasing protection, ON / OFF push buttons, ammeter, voltmeter, indicating lamps, MCB etc. complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . | 0 | Each | 0 | ₹0 |
| 10 | more than 7500 cfm to 15000 cfm | 7 | Set | 23,281 | ₹1,62,967 |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.30 MB
AgrrementRTPPandetc.pdf
Tender Documents • 2.75 MB
Termsconditions.pdf
Tender Documents • 0.01 MB
BankDetail00.pdf
Tender Documents • 0.17 MB
BOQ_997097.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .