| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.4 LAccepted-AOC HOUSE NO 251 E BLOCK ADARSH NAGAR BALLABHGARH FARIDABAD 121004 HARYANA | FARIDABAD | FARIDABAD | HARYANA | 121004 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹23.5 L+₹1.5 L (6.67%)Rejected-Finance 403 GH MANSADEVI COMPLEX PANCHKULA 134109 HARYANA | PANCHKULA | HARYANA | 134109 | L2 | Rejected-Finance other than L1 | |
| 3 | L3₹33.0 L+₹10.9 L (49.3%)Rejected-Finance 01 NEW MATTAN ADDA ANANTNAG ANANTHNAG JAMMU KASHMIR 192101 | ANANTNAG | JAMMU AND KASHMIR | 192101 | L3 | Rejected-Finance Other than L1 |
| Sl No | Description | Qty | Unit | national engineering L1 | EESSI L2 | Asian Marketing Co L3 |
|---|---|---|---|---|---|---|
| 1.00 | M&L for dismantling standalone air heater for space heating of capacity upto 50000 Kcal/hr by unscrewing and removal of heater side/end plates, with scalent de-carbonizing, scrapping out carbon, dirt accumulated in heater, overhauling, servicing including re-assembling all the dismantled component to its original position with testing and commissioning, complete all as specified and directed by Engineer-in-Charge. | 15 | Each Job | 8,000 ₹1,20,000 | 10,000 ₹1,50,000 | 2,400 ₹36,000 Lowest |
| 2.00 | M&L for dismantling of the blower motor of stand alone air heater for space heating of capacity upto 50000 K/Cal Hr including rewinding of blower motor with suitable size/gauge of copper wire including replacement of suitable blower fan sweep and blower fan guard and refixing of the same after varnishing, complete all as specified and directed by Engineer-in-Charge. | 10 | Each Job | 10,000 ₹1,00,000 | 3,000 ₹30,000 | 1,500 ₹15,000 Lowest |
| 3.00 | M&L for dismantling standalone air heater for space heating of capacity upto 25000 Kcal/hr by unscrewing and removal of heater side/end plates, with scalent de-carbonizing, scrapping out carbon, dirt accumulated in heater, overhauling, servicing incl re-assembling all the dismantled component to its original position with testing and commissioning, complete all as specified and directed by Engineer-in-Charge. | 10 | Each Job | 8,000 ₹80,000 | 10,000 ₹1,00,000 | 1,800 ₹18,000 Lowest |
| 4.00 | M&L for dismantling of the blower motor of stand alone air heater for space heating of capacity upto 25000 K/Cal Hr including rewinding of blower motor with suitable size/gauge of copper wire including replacement of suitable blower fan sweep and blower fan guard and refixing of the same after varnishing, complete all as specified and directed by Engineer-in-Charge. | 6 | Each Job | 8,000 ₹48,000 | 3,000 ₹18,000 | 1,500 ₹9,000 Lowest |
| 5.00 | M&L for dismantling standalone air heater for space heating of capacity upto 10000 Kcal/hr by unscrewing and removal of heater side/end plates, with scalent de-carbonizing, scrapping out carbon, dirt accumulated in heater, overhauling, servicing incl re-assembling all the dismantled component to its original position with testing and commissioning, complete all as specified and directed by Engineer-in-Charge. | 6 | Each Job | 8,000 ₹48,000 Lowest | 10,000 ₹60,000 | 8,500 ₹51,000 |
| 6.00 | M&L for dismantling of the blower motor of Stand alone air heater for space heating of capacity upto 10000 K/Cal Hr incl rewinding of blower motor with suitable size/gauge of copper wire including replacement of suitable blower fan sweep and blower fan guard and refixing of the same after varnishing, complete all as specified and directed by Engineer-in-Charge. | 5 | Each Job | 8,000 ₹40,000 | 3,000 ₹15,000 Lowest | 12,000 ₹60,000 |
| 7.00 | Supply and fix in replacement blower motor of 1 hp or suitable for capacity of stand alone air heater, 230 volt 50 Hz, for space heating of capacity of stand alone heater upto 50000 K/Cal Hr including replacement of suitable blower fan sweep and blower fan guard and refixing of the same after varnishing, complete all as specified and directed by Engineer-in-Charge. | 5 | Each Job | 12,000 ₹60,000 | 15,000 ₹75,000 | 7,500 ₹37,500 Lowest |
| 8.00 | Supply and fix in replacement photocell suitable, complete all as per sample all as specified & directed by Engr-in-Charge. Make:- Alfa Therm/ Rapid cool / Thermax boiler | 16 | Each | 1,200 ₹19,200 | 500 ₹8,000 Lowest | 2,500 ₹40,000 |
| 9.00 | Supply and fix in replacement ignition transformer 220 Volts having out/input 11 KV to 14 KV suitable, complete as per sample complete all as directed & specified. x | 10 | Each | 4,000 ₹40,000 | 2,000 ₹20,000 Lowest | 8,000 ₹80,000 |
| 10.00 | Supply and fix in replacement Ignition electrode, complete all as per sample all as specified & directed by Engr-in-Charge. Make:- Alfa Therm/ Rapid cool / Thermax boiler | 10 | Each | 200 ₹2,000 Lowest | 1,200 ₹12,000 | 4,500 ₹45,000 |
Tender Value
₹29 L
EMD Value
₹58,000
Closing Date
29 Jul 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE, HQ 138 WE
CWE, HQ 138 WE
REPAIR AND MAINT OF STAND ALONE HEATING SYSTEM FOR SASOMA, BASE CAMP AND KHALSAR AND MISC MAINT WORKS OF CENTRAL HEATING SYSTEM AND HOT WATER PLANTS AT HUNDER AND KHALSAR UNDER GE 873 EWS
2025_MES_716905_1
138WE/L-94/2025-26
Open Tender
Civil Works
Item Rate
270 days
GE 873 EWS
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
GE 873 EWS
₹58,000
Yes
18 Sept 2025
26 Jun 2025
5 Aug 2025
26 Jun 2025
29 Jul 2025
10 Jul 2025
Amount
M&L for dismantling standalone air heater for space heating of capacity upto 50000 Kcal/hr by unscrewing and removal of heater side/end plates, with scalent de-carbonizing, scrapping out carbon, dirt accumulated in heater, overhauling, servicing including re-assembling all the dismantled component to its original position with testing and commissioning, complete all as specified and directed by Engineer-in-Charge.
M&L for dismantling of the blower motor of stand alone air heater for space heating of capacity upto 50000 K/Cal Hr including rewinding of blower motor with suitable size/gauge of copper wire including replacement of suitable blower fan sweep and blower fan guard and refixing of the same after varnishing, complete all as specified and directed by Engineer-in-Charge.
M&L for dismantling standalone air heater for space heating of capacity upto 25000 Kcal/hr by unscrewing and removal of heater side/end plates, with scalent de-carbonizing, scrapping out carbon, dirt accumulated in heater, overhauling, servicing incl re-assembling all the dismantled component to its original position with testing and commissioning, complete all as specified and directed by Engineer-in-Charge.
M&L for dismantling of the blower motor of stand alone air heater for space heating of capacity upto 25000 K/Cal Hr including rewinding of blower motor with suitable size/gauge of copper wire including replacement of suitable blower fan sweep and blower fan guard and refixing of the same after varnishing, complete all as specified and directed by Engineer-in-Charge.
M&L for dismantling standalone air heater for space heating of capacity upto 10000 Kcal/hr by unscrewing and removal of heater side/end plates, with scalent de-carbonizing, scrapping out carbon, dirt accumulated in heater, overhauling, servicing incl re-assembling all the dismantled component to its original position with testing and commissioning, complete all as specified and directed by Engineer-in-Charge.
M&L for dismantling of the blower motor of Stand alone air heater for space heating of capacity upto 10000 K/Cal Hr incl rewinding of blower motor with suitable size/gauge of copper wire including replacement of suitable blower fan sweep and blower fan guard and refixing of the same after varnishing, complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement blower motor of 1 hp or suitable for capacity of stand alone air heater, 230 volt 50 Hz, for space heating of capacity of stand alone heater upto 50000 K/Cal Hr including replacement of suitable blower fan sweep and blower fan guard and refixing of the same after varnishing, complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement photocell suitable, complete all as per sample all as specified & directed by Engr-in-Charge. Make:- Alfa Therm/ Rapid cool / Thermax boiler
Supply and fix in replacement ignition transformer 220 Volts having out/input 11 KV to 14 KV suitable, complete as per sample complete all as directed & specified. x
Supply and fix in replacement Ignition electrode, complete all as per sample all as specified & directed by Engr-in-Charge. Make:- Alfa Therm/ Rapid cool / Thermax boiler
Supply and fix in replacement solenoid valve, complete all as per sample all as specified & directed by Engr-in-Charge. Make:- Alfa Therm/ Rapid cool / Thermax boiler
Supply and fix in replacement fuel filter body, complete all as per sample all as specified and directed by Engineer-in-Charge. Make:- Alfa Therm/ Rapid cool / Thermax boiler
Supply and fix in replacement fuel filter, complete all as per sample all as specified and directed by Engineer-in-Charge. Make:- Alfa Therm/ Rapid cool / Thermax boiler
Supply and fix in replacement fuel pump for burner, complete all as per sample all as specified and directed by Engineer-in-Charge. Make:- Alfa Therm/ Rapid cool / Thermax boiler
Supply and fix in replacement sequence controller complete all as per sample all as specified and directed by Engineer-in-Charge
Supply and fix in replacement digital temperature controller, complete all as per sample all as specified & directed by Engr-in-Charge.Make:- Alfa Therm/ Rapid cool / Thermax boiler
Supply and fix in replacement refractory plate paste top & bottom side and including Gasket change as per sample all as specified & directed by Engr-in-Charge.
Repair of burner and burner assembly of hot water generator / stand alone heater including rewinding of burner, replacement of unserviceable nozzle with new one of suitable size and other connected items all as directed by Engr-in-Charge. Make:- Alfa Therm/ Rapid cool / Thermax boiler
M&L for cement concrete in foundation, filling and mass concrete 1:2:4 type B1 using 20mm graded stone aggregate for foundation.
M&L dismantling carefully of Chimney smoke exhaust outlet fabricated extension MS pipe of boiler cleaning, removal carbon by scrapping out and washing with scalent and acid/ kerosene oil etc and removing of fume waste carbonized materials and disposal of fume waste after every 500 Hrs operation incl re-assembling all the dismantled component to its original position for smooth functioning of chimney, complete all as specified and directed by Engineer-in-Charge.
M&L for dismantling oil fired hot water generator/boiler of 4 Lakh K.Cal/hour capacity any model by unscrewing and removal of boiler side/end plates, CHS control panel, cleaning drum and hot water coil with scalent de-carbonizing, scrapping out carbon, dirt accumulated in drum and across coil, overhauling, servicing incl re-assembling all the dismantled component to its original position with testing and commissioning, complete all as specified and directed by Engineer-in-Charge.
M&L for dismantling oil fired hot water generator of 2 to 2.5 Lakh K.Cal/hour capacity any model by unscrewing and removal of boiler side/end plates, CHS control panel, cleaning drum and hot water coil with scalent de-carbonizing, scrapping out carbon, dirt accumulated in drum and across coil, overhauling, servicing incl re-assembling all the dismantled component to its original position with testing and commissioning, complete all as specified and directed by Engineer-in-Charge.
Supply and fix of Heat Tracing cable (heating element) suitable for water supply pipe line, complete all as specified and directed by Engr-in- Charge
M&L for dismantling oil fired hot water generator of 3 X 0.5 Lakh K.Cal/hour (Boiler) capacity any model by unscrewing and removal of boiler side/end plates, CHS control panel, cleaning drum and hot water coil with scalent de-carbonizing, scrapping out carbon, dirt accumulated in drum and across coil, overhauling, servicing incl re-assembling all the dismantled component to its original position with testing and commissioning, complete all as specified and directed by Engineer-in-Charge. (Note:- Each Job requires servicing of 03 X .50 Lakh K. Cal/hr boilers)
M&L for dismantling carefully CHS pump and motor assembly 7.5 HP for repair and remove the broken impeller and worn out nuts/bolts washer's complete incl rewinding removal of burnt winding for field and stator, rewinding the same with super enamel copper conductor of existing gauge varnishing, heating, baking complete with re-assembling all the dismantled component to its original position with testing, complete all as specified and directed by Engineer-in-Charge. Note: Spares parts required for repair work will be measured in relevant item of BOQ
Supply only brass impellor
Supply only copper winding wire suitable gauge of existing motor
M&L for disconnecting and removal of burner assembly, cleaning of burner for de-carbonized/deposited on combustion tank /blast tube with cleaning acid and fixing of burner nozzle for smooth functioning and re-assembling burner and fixed to its original position with testing, complete all as specified and directed by Engineer-in-Charge. Note: Spares parts required for repair work will be measured in relevant item of BOQ
Supply only burner nozzle jet suitable for burner
Supply only photocell suitable for burner
Supply only fuel pump suitable for burner
Supply ony flexible metal fuel pipe suitable for plant
Supply only fuel filter
Supply only magnetic lead (Electrode)
Supply only time relay suitable for CHS burner assembly
Supply only fuel Ignition transformer suitable for burner
M&L for taking down carefully by disconnecting and removing Fan coil units of different sizes from hot water circulation line for cleaning with scalent and acid to remove the scale and dirt accumulated in copper tube, fins and cleaning of radiatorparts of FCU and welding/ brazing wherever necessary and arrest the leakage of the body incl re-assembling and connect the same to its original position with testing complete for smooth flow of water, complete all as specified and directed by Engineer-in-Charge. Note: Spares parts required for repair work will be measured in relevant item of BOQ
Supply only fan motor suitale for fan coil unit
Supply only PCB board suitable for exixting FCU
M&L for disconnecting hot water inlet & outlet of glycol base storage tank of capacity 1000 Ltrs draining out complete old water cleaning, removal of sludge accumulated by scrapping out, washing with scalent/acid for properly cleaning and welding wherever necessary to arrest leakages with re-assembling the disconnected pipes to original position and filling water including refilling/ charging of glycol (monoethylene glycol) MEG concentrate along with necessary additives and inhibitor in cognition and mixed in ratio 40% (glycol concentrate) 60% of water and the freezing temperature of mixture shall be -40 degree centigrade, complete all as specified and directed by Engineer-in-Charge. (Note : Monoethylene glycol will be measured and paid seperately)
Supply and fix in replacement of unserviceable fan coil unit of capacity 3000 K/Cal capacity High Wall mounted motorised valve alongwith Inlet outlet valves and remote control. Make-Caryaire/Bluestar/Voltas.
Supply and fix in replacement of unserviceable fan coil unit of capacity 4500 K/Cal capacity High Wall mounted motorised valve alongwith Inlet outlet valves and remote control. Make-Caryaire/Bluestar/Voltas.
Supply and fix replacement of monoblok pump motor for circulation of hot water 5HP 3 phase 415 volt 50 Hz, complete all as specified and directed by Engr-in-Charge
Supply and fix replacement of monoblok pump motor for circulation of hot water 3HP 3 phase 415 volt 50 Hz, complete all as specified and directed by Engr-in-Charge
Supply and fix ball brass valve with adapter screwed both ends of 15 MM bore suitable for heat radiator hot water inlet/outlet, complete all as specified and directed by Engineer-in-Charge. Make : CE /Zoloto/Leader/ R&N
S&F metal coupling of the CHS pump 2 HP male/female star coupling as per sample, complete all as specified and directed by Engineer-in-Charge.
Supply and fix coupler with fiber super impregnated suitable to match the male/female couplings as per sample held with AGE E/M Sub Div Partapur, complete all as specified and directed by Engineer-in-Charge.
Supply and fix PVC flexible pipe insulated model SAE 100 RIAT 1/2" suitable for fixing with heat radiator hot water inlet and out let with locking clips, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of U/S chimney exhaust extension pipe of size 200 mm dia 3 length 6 mm thick, complete all as specified and directed by Engineer-in-Charge.
M & L calibration of humidity control system to maintain required humidity for smooth functioning & maintaining the humidifier to required humidity, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of U/S phase sequence meter 230 volt 50 Hz AC as per sample for each phase, complete all as specified and directed by Engineer-in-Charge. Make : L&T/C&S/Havells'/Legrand/
Supply, mixing and filling of mono ethylene Glycol concentrate along with necessary additives and inhibitor in congnition and sealed in barrels. The mixture freezing tempreture shall be (-) 35°C, all as specified. The mode of payment and operation involved for this item shall be as under:- Note: (a) Mono Ethylene Glycol in concentrated form shall only be measured and paid under this item. (b) Material and labour for mixing, filling, preparation fo Gylocol Charge to get total quantity of mixture including first filling required for operation of CHS plant and network having 40% quantity of treated water available at site and 60% of mono ethylene glycol supplied as above to attain the freezing temperature of mixture as (-) 35°C. The quoted rates shall be deemed to include the above activity/work. (c) The water for preparation of mixture will be supplied by MES without any extra charges for this item (only). The water shall be supplied at a point decided by GE and quoted rates shall deemed to be included for transportation of same from the take off point. (d) Any other additives and inhibitors as per the requirement laid down in relevat IS shall also deemed to included in quoted rates. (e) Glycol shall be supplied only in sealed containers. (f) Empty barrels shall be the property of contractor. (g) Test report from BIS certified lab and Gas chromatography shall be submitted by the contractor for each lot of supply Make: Indian oil/Hindustan petroleum/Bharat petroleum
S&F copper tubing of size 15 mm including necessary fittings like union and adopter including all fitting for inlet and outlet complete.
M&L for Insulation of MS pipe with PUF slab 30/40 mm thick with and including applying bituminous compound and GI cladding with 26 gauge GI sheet for following sizes complete all as specified and directed :-
80mm bore pipe
65mm bore pipe
50mm bore pipe
40mm bore pipe
32mm bore pipe
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for laying of pipe and getting out all in any type of soil.
Returning, filling in, including spreading, watering and well ramming in layers not exceeding 25cm thick in any type of soil
Removing excavated material (soil) to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above starting point.
M&L for arc gas welding for repair any leakages of hot water pipeline if necessary, complete all as directed by the Engr-in-Charge Note:- Necessary toll & plant will be provide by the contractor
M&L for duct insulation with resin bonded fibre glass wool roll of density 24 kg/Cum, with factory laminated aluminium vapour barrier, thickness of insulation as specified and including the following:- (a) M&L for cleaning the duct surface (to be insulated ) by scrapping carefully with wire brush etc. to make the surface completely free of millscale, dirt, dust, grease and other foreign materials, taking special care so that all duct joints are sealed against any leakage. (b) M&L for applying rubber based adhesive CPRX compound.(c) M&L for sealing of all longitudinal joints and circular overlaps with and including Aluminium foil tape 50 mm wide, to make the insulation leakproof. (d) M & L for securing the insulation with and including mechanically fastened nylon/ steel straps of size 12 mm/50 mm at maximum intervals of 1.2 mt
M& L for dismantling of AHU including taking down blower and blower motor, servicing of AHU, replacing of damaged parts like thermal senser, blower shaft bearing, blowerbelt, hepa filter, refix the same after repair and make it functional complete all as specified and directeed Note: Spares parts required for repair work will be measured in relevant item of BOQ
Blower fan belt suitable for exixting size
Hepa filter (99.9 Micron)
Blower shaft bearing
Control relay suitable for existing capacity
Supply and fix of fins type heating element 3 KW each and make necessary arrangement and electrical conections in duct comlete all as specified and directd
Supply and fix in replacement of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade cross-sectional area 25 Sqmm 3.5 core complete all as specified and directed
EESSI (BID ID -3358463)
Asian Marketing Co (BID ID -3367139)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .