Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.3 LAccepted-AOC CHENNAI | CHENNAI | TAMIL NADU | 600001 | L1 | Accepted-AOC Accepted. PO.NO.57/2023-24 dt.22.02.2024 | |
| 2 | L2₹3.5 L+₹15,784.86 (4.67%)Rejected-AOC 36 BLOCK 12 PILOT QUARY STREET NEYVELI CUDDALORE TAMIL NADU 607802 | CUDDALORE | TAMIL NADU | 607802 | L2 | Rejected-AOC rejected L2 bidder |
Tender Value
Refer Docs
EMD Value
₹3,500
Closing Date
20 Nov 2023, 2:00 pmClosed
SE VGTPS
VGTPS, Ramanathapuram
Various types of Power Contactor Make ABB and L and T or equivalent, Auxiliary Switches and Various Capacity of Control transformers
2023_EB_385992_1
SE/VGTPS/RMD/ENQ.NO.52/2023-24
Open Tender
Miscellaneous Goods
Supply
30 days
SE VGTPS
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹3,500
Yes
2 Mar 2024
4 Nov 2023
21 Nov 2023
4 Nov 2023
20 Nov 2023
4 Nov 2023
Amount
Various types of power contactors, and various capacity of control transformers
Make :ABB or equivalent Model : A95-30-11 or equivalent (Cutout dimension and other specification should be same if quoted equivalent model) Detailed catalogue & dimension drawings required HSN Code: 8536,AC 3-phase Contactor suitable for Motor DOL Starter, 415VAC, 50 Hz,Number of Pole : 3 Pole Rated Amps : 145A,Rated Control Circuit Voltage (Uc) :110V,50 Hz Number of Auxiliary Contacts 1 NO, 1NC Rated Operational Voltage : Main Circuit 1000 V Conventional Free-air Thermal Current (Ith) : acc. to IEC 60947-4-1, Open Contactors q = 40 °C 145 A Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1 : 8 x Ie AC-3 Rated Making Capacity AC-3 acc. to IEC 60947-4-1 : 10 x Ie AC-3 Short-Circuit Protective Devices :gG Type Fuses 160 A Rated Insulation Voltage (Ui) : acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 ,Rated Impulse Withstand Voltage (Uimp) : 8 kV Mechanical Durability : 10 million Maximum Mechanical Switching Frequency : 3600 cycles per hour Terminal Type : Screw Terminals
Make :ABB or equivalent Model :A30-30-10 or equivalent (Cutout dimension and other specification should be same if quoted equivalent model) Detailed catalogue & dimension drawings required HSN Code: 8536,AC 3-phase Contactor suitable for Motor DOL Starter, 415VAC, 50 Hz,Number of Pole : 3 Pole Rated Amps : 55A ,Rated Control Circuit Voltage (Uc) :110V,50 Hz Number of Auxiliary Contacts 1 NO, 1 NC Rated Operational Voltage :Main Circuit 690 V Conventional Free-air Thermal Current (Ith) : acc. to IEC 60947-4-1, Open Contactors q = 40 °C 65 A Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1 : 8 x Ie AC-3 Rated Making Capacity AC-3 acc. to IEC 60947-4-1 : 10 x Ie AC-3 Short-Circuit Protective Devices :gG Type Fuses 63 A Rated Insulation Voltage (Ui) : acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V,acc. to UL/CSA 600 V,Rated Impulse Withstand Voltage (Uimp) : 8 kV,Mechanical Durability : 10 million Maximum Mechanical Switching Frequency : 3600 cycles per hou Terminal Type : Screw Terminals
Make :ABB or equivalent (Suitable for existing ABB makeAF116-30-11Model no) Model :AF116-30-11 or equivalent (Cutout dimension and other specification should be same if quoted equivalent model) Detailed catalogue & dimension drawings required HSN Code: 8536 DC Power Contactor suitable for Motor star,220VDC,50 Hz Number of Pole : 3 Pole Rated Amps : 160A Rated Control Circuit Voltage (Uc) :220V DC,50 Hz Number of Auxiliary Contacts 1 NO, 1 NC Rated Operational Voltage :Main Circuit 1000 V Conventional Free-air Thermal Current (Ith) : acc. to IEC 60947-4-1, Open Contactors q = 40 °C 160 A Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1 : 8 x Ie AC-3 Rated Making Capacity AC-3 acc. to IEC 60947-4-1 : 10 x Ie AC-3 Short-Circuit Protective Devices: gG Type Fuses 160 A Rated Insulation Voltage (Ui) : acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V Rated Impulse Withstand Voltage (Uimp) : 8 kV Mechanical Durability : 10 million Maximum Mechanical Switching Frequency : 300 cycles per hour Terminal Type : Screw Terminals
110 KV Isolator Auxiliary Switch Make : Mani or equivalent, Capacity : 10 A DC, Breaking Capacity : 2 A DC, 6 NO, 6NC IS : 6875 & IEC 694, HSN Code: 8536
110 KV Earth Auxiliary Switch Make : Mani or equivalent,Capacity:10A DC, Breaking Capacity : 2 A DC, 4NO, 4 NC IS : 6875 & IEC 694 HSN Code: 8536
L&T Make or equivalent (Power Contactor) (MNX 9, 9AMPS, 415V, 3Pole, 1NO, Control Voltage: 230V AC 50HzIEC: 60947-4-1,IS: 13947-4-1) HSN Code: 8536
L&T Makeor equivalent (Power Contactor) (MNX 12, 12AMPS,415V,3Pole,1NO,Control Voltage: 230V AC 50Hz,IEC: 60947-4-1,IS: 13947-4-1) HSN Code: 8536
L&T Make or equivalent (Power Contactor) (MNX 18, 18AMPS,415V,3Pole,1NO Control Voltage: 230V AC 50HzIEC: 60947-4-1,IS: 13947-4-1, HSN Code: 8536
L&T Makeor equivalent (Power Contactor) (MNX 25, 25AMPS,415V,3Pole, Control Voltage: 110V AC 50HzIEC: 60947-4-1,IS: 13947-4-1) HSN Code: 8536
L&T Makeor equivalent (Power Contactor) (MNX 32, 32AMPS, 415V, 3Pole, Control Voltage: 110V AC 50HzIEC: 60947-4-1,IS: 13947-4-1. HSN Code: 8536
L&T Make or equivalent (Power Contactor) (MNX 32, 32AMPS, 415V, 3Pole, Control Voltage: 230V AC 50HzIEC: 60947-4-1,IS: 13947-4-1. HSN Code: 8536
L&T Make or equivalent (Power Contactor) (MNX 50, 50AMPS, 415V, 3Pole, Control Voltage: 110V AC 50HzIEC: 60947-4-1,IS: 13947-4-1.2NO+2NC INBUILT) HSN Code: 8536
Control Transformer Make: Precise or equivalent, Capacity : 500VA, HV : 415V,LV :110VAC,1PH,(+)(-)2.5%,,(+)(-) 5% TAP ON PRIMARY Type : DRY TYPE HSN Code: 8504
Control Transformer Make : Precise or equivalent, Capacity :300VA, HV : 415V, LV :110VAC,1PH,(+)(-)2.5%,,(+)(-) 5% TAP ON PRIMARY Type : DRY TYPE, TAPE WOUND HSN Code: 8504
Control Transformer Make : Precise or equivalent, Capacity :100VA, HV : 415V, LV :110VAC,1PH,(+)(-)2.5%,,(+)(-) 5% TAP ON PRIMARY Type : DRY TYPE, TAPE WOUND HSN Code: 8504
Annaamalai Engineers
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .