| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.6 LAccepted-AOC 2 SURI LANE GROUND FLOOR KOLKATA 700 014 | KOLKATA | KOLKATA | WEST BENGAL | 700014 | L1 | Accepted-AOC Lowest Bid | |
| 2 | L2₹1.7 L+₹6,556 (3.99%)Rejected-AOC 0 3 ONKARMAL JATIA ROAD HOWRAH 711103 | HOWRAH | HOWRAH | WEST BENGAL | 711103 | L2 | Rejected-AOC Higher Bid | |
| 3 | L3₹1.8 L+₹11,166 (6.79%)Rejected-AOC 123 2A AMHARST STREET KOLKATA 700 009 | KOLKATA | KOLKATA | WEST BENGAL | 700009 | L3 | Rejected-AOC Higher Bid | |
| 4 | L4₹1.9 L+₹21,706 (13.2%)Rejected-AOC 10 11 UMACHARAN BHATTACHARYA LANE SHIBPUR HOWRAH 711101 | HOWRAH | HOWRAH | WEST BENGAL | 711101 | L4 | Rejected-AOC Higher Bid |
Tender Value
Refer Docs
EMD Value
₹3,421
Closing Date
25 Oct 2022, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Assistant Engineer, PWD, ECSD
Office of the Assistant Engineer, PWD Electrical Construction Sub-Division K.S.Roy T.B. Hospital, Jadavpur, Kolkata-32
EI work of Govt Qtrs Nos I 02 and F 05 at Tollygunge Emergency Force Line Tollygunge Kolkata.
2022_WBPWD_415505_1
WBPWD/ECSD/eNIT-01/2022-23(2nd Call)
Open Tender
ELECTRICAL WORKS ORG
Item Rate
10 days
Tollygunge Emergency Force
Please refer Tender documents.
3 documents required · 3 mandatory
₹3,421
9 Nov 2022
18 Oct 2022
28 Oct 2022
18 Oct 2022
25 Oct 2022
18 Oct 2022
Amount
Dismantling the Existing wiring after disconnection of all incomming & outgoing line, existing board, fittings fixture etc.
Supplying and fixing 2way MCB SS enclosure incl 240 V 40 A DP MCB with IP-20/30 protection, powder coated provision for two pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment. (Legrand/ ABB/ L & T/ Havells etc) [For 2 nos. Quarter] [PWD/GS Page: D-9 Item: 11, Page: D-6 Item: 7]
S&F 2+8 way double-door SPN MCB Distribution Board with IP-42/43 protection, with 240 V 40 A DP MCB isolator as incomer and 8 nos. 6-32A SPMCB as outgoing, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.as per GS (Make -Legrand/ABB/L&T /Seimens) [For 5 nos. Quarter] [PWD/GS Page: D-9 Item: 13, Page: D-6 Item: 7]
Supply & Laying of PVC insulated sheathed Al / XLPE power cable of 1.1 KV grade 2 Core x 10 sqmm strandred on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting [Make : Nicco / Gloster/Polycab / RR] [ From DP MCB to SPN DB] [Supply of cable - Non-Schedule Item, Laying of Cable - PWD/GS Page: F-1 Item: 2]
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below (a)2 Core x 10 sq.mm . [PWD/GS Page: F-4 Item: 7 ]
Finishing of the XLPE/PVC insulated armoured cable ends by soldering with cable sockets and insulated tapes etc., including supplying sockets, soldering materials, tapes etc. and making connection to switch, BDB and BBC etc. (a) 2 Core x 10 sq.mm . [PWD/GS Page: F-5 Item: 8/b ]
Supply & Laying of 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire in 20mm size PVC rigid pipe on wall ncl. mending good the damages as per direction of EIC. [PWD/GS Page: E-14 Item: 1 ] 2x2.5 sqmm + 1x1.5 sqmm [ for power plug/computer]
3x1.5 sqmm
Finishing the end of PVC insulated insulated & unsheated copper wire as per direction of EIC. [PWD/GS Page: F-5 Item: 9 ] 2x2.5 sqmm + 1x1.5 sqmm
2. Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch(Brand approved by EIC) fixed on Modular GI switch board with top cover plate and 2 no. suitable size “Ph & N” copper bar & earthing attachment fixed on wall incl. mending good the damages to original finish as per GS (Avg. Run 6 Mtr)
do-do……(on board)
do-do………(Avg Run 8 Mtr)
Supply & Fixing of 12 Module Type GI box complete with its 12 module plate incl. S & F of followinf accessories & making necy. Inter connection as required. (A) 6A 3 pin modular plug socket = 03 Nos. (B) 6A modular switch = 03 Nos. (Make - Schneider)
Supply & Fixing of 6 Module Type GI box complete with its 6 module plate incl. S & F of followinf accessories & making necy. Inter connection as required. (A) 6A 3 pin modular plug socket = 02 Nos. (B) 6A modular switch = 02 Nos. (Make - Schneider)
Supply & Fixing of 4 Module Type GI box complete with its 4 module plate incl. S & F of followinf accessories & making necy. Inter connection as required. (A) 16A 3 pin modular plug socket = 01 Nos. (B) 16A modular switch = 01 Nos. (Make - Schneider)
Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board with top cover plate incl. making necy. connections etc. As to GS
Supply & Fixing 240 V, 10W-12 W, 100 lm/W LED bulk head light fitting and complete with all accessories incl. mending the damages as directed by EIC [Make-Havells/ Wipro/Crompton/Bajaj] [Supply of light - Non-Schedule Item, Fixing of Light - PWD/GS Page: C-2 Item: 13 ] [For Room's Toilet/Lift]
Earthing Installation – with Pipe Electrode : Excavation of soil for installation of Earth Electrode and filling & ramming. For Soft Soil [PWD/GS Page: G-1 Item: 1]
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts.long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm diax 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below : By TATA-Medium GI pipe [PWD/GS Page: G-1 Item: 2/a] [2 nos. for EI]
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos.12 mm dia holes on the GI pipe. [PWD/GS Page: G-2 Item: 3/a]
Earth Busbar Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 50 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required. [PWD/GS Page: G-2 Item: 4/c]
Earth Continuity Strip Connecting the equipments to earth busbar including S & F 20 mm x 3 mm Galvanised (Hot Dip) MS Flat on wall / floor with GI saddles as required and connection to equipments with incl. drilling holes, bolts, nuts, washers etc. [PWD/GS Page: G-3 Item: 5/c]
BANERJEE CONCERN
B S ENTERPRISE
M/S ELECTRO POWER
technical_818949.pdf
PDF • 0.33 MB
techsummary_818949.pdf
PDF • 0.14 MB
finance_818949.pdf
PDF • 0.34 MB
BOQ Comparative Chart
xlsx • 0.01 MB
finsummary_818949.pdf
PDF • 0.16 MB
Document5.pdf
PDF • 0.24 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .