Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹24.4 LAccepted-AOC DEORA THANA WAIDHAN DISTT SINGRAULI M P | WAIDHAN | SINGRAULI | MADHYA PRADESH | 486887 | L-1 | Accepted-AOC Being the lowest bidder | |
| 2 | L-2₹37.0 L+₹11.4 L (44.6%)Rejected-AOC 5 A LANE 1 GREATER KAILASH JAMMU J K 180011 | JAMMU | JAMMU AND KASHMIR | 180011 | L-2 | Rejected-AOC Not being the lowest bidder | |
| 3 | L-3₹37.4 L+₹11.9 L (46.4%)Rejected-AOC | L-3 | Rejected-AOC Not being the lowest bidder |
Tender Value
₹37.5 L
EMD Value
₹75,000
Closing Date
24 Aug 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
LT COL SANGRAM SINGH
GE Kaluchak Pin-900673 C/o 56 APO
PROVN OF SEPTIC TANK WITH CONNECTED WORK AND CERTAIN SANCTIONED WORK AT KALUCHAK MIL STN UNDER GE KALUCHAK
2020_MES_363798_1
GE/KC/NIT-32/2020-21
Open Tender
Miscellaneous Works
Item Rate
180 days
Kaluchak
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE Kaluchak
₹75,000
Yes
15 Sept 2020
24 Jul 2020
26 Aug 2020
24 Jul 2020
24 Aug 2020
12 Aug 2020
24 Jul 2020 - 11 Aug 2020
60 days
Amount
B/R Portion
Surface Excavation not exceeding 30cm deep and averaging 15cm deep and getting out in any type of soil, complete all as specified and directed.
Excavating in trenches, not exceeding 1.5metre wide and not exceeding 1.5metre depth for foundation, etc., and getting out in any type of soil, complete all as specified and directed.
Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering and removing the surplus spoil to a distance not exceeding 50 metres and making good surface in any type of soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick any type of soil, complete all as specified and directed.
Removing excavated soils exceeding 50m but not exceeding 100m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Cement concrete type D-2 1:4:8 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete, complete all as specified and directed.
Demolition of brick work masonry built in cement mortar including all quoins, pillars etc. but excluding ashlars facing, dressed stone work and precast concrete articles complete all as specified and as directed.
Brick work with sub class ‘B’ bricks, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:4, complete all as specified and directed.
Plain cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as in cills, lintels upto 1.5 metre clear span, steps, seismic and other similar band, plinth course, string courses, lacing courses, parapets and railing upto 60cm in height, copings, kneelers, apex stone, bed plates, kerbs etc and in similar works including weathering, slightly rounded or chamfered angles and throating and necessary form work complete, all as specified and as directed.
Plain cement concrete 1:2:4 type B-2 (using 40 mm graded crushed stone aggregate) as in walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts etc and in similar works including necessary form work complete, all as specified and as directed.
RCC 1:2:4, Type B-1 (using 20 mm graded crushed stone aggregate) as in foundation including footing, foundation beam, plinth beam, base of column and mass concrete complete as required, complete all as specified and as directed.
RCC 1:1.5:3, Type A-1 (using 20 mm graded crushed stone aggregate) as in columns, pillars, piers, posts and struts complete all as specified and as directed.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter rough finish flat surfaces of concrete, complete, all as specified and as directed.
Formwork to sides of pillars, posts, struts, piers, columns and stanchions and similar work; finish flat surfaces of concrete, complete, all as specified and as directed.
TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, all as specified and as directed.
TMT bars 6 to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, all as specified and as directed.
TMT bars 5mm dia and over upto and including 10mm dia, cut to length bent to shape including binding with MS annealed wire of dia not less than 0.90mm as in stirrups, spacers and binders, complete, all as specified and as directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc. Including brushing neat cement slurry with 3.0Kg of Cement per Square Metre complete all as specified and as directed.
Taking down cement plaster on bricks or stone wall/ceiling decayed surfaces of concrete from roof projection or RCC chajjas etc. including racking out joints, hacking for key, scrubbing down with water etc., complete all as specified and directed.
Rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces, finished even and smooth with out using extra cement, complete all as specified and directed.
Rendering 15mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces, finished even and smooth with out using extra cement, complete all as specified and directed.
Rendering 10mm thick in cement mortar 1:3 on fair faces of brick work or concrete surfaces as in ceilings finished even and smooth without using extra cement, complete all as specified and directed.
Hard core of broken stone gauge exceeding 63mm and not exceeding 100mm deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surfaces, complete, all as specified and as directed.
75 mm thick Cement concrete type B-2, 1:2:4 (using 40 mm graded crushed stone aggregate) in flooring finished even and smooth without using extra cement complete all as specified and directed.
100 mm thick Plain Cement concrete type B-2, 1:2:4 (using 40 mm graded crushed stone aggregate) in paving, path etc finished even and smooth without using extra cement complete all as specified and directed.
Forming 20 mm thick expansion joints 100mm deep filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘B’ for 100mm thick concrete slab complete all as specified and as directed.
Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) of any description and in any position not otherwise specifically provided for and removing rubbish from the site, complete all as specified and directed.
Demolition of cement concrete in ground floors and paving (un-reinforced) not exceeding 15cm. thickness, below or above ground level, complete and removing rubbish from the site, complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and as directed.
Non-skid coloured ceramic tiles of any shade and any pattern of size (Pattern consists combination of two or more tiles) 400mm x 400mm x 7mm thick, over and including 15mm thick screed bed in CM 1:4 as in floors etc. jointed in neat cement slurry and pointed in coloured cement to match coloured tiles, complete all as specified and directed.
Glazed ceramic coloured wall tiles in any type and in any pattern (Pattern consist of combination two or more diffrent colour tiles etc.) in vertical surfaces of size 450mm x 300mm x 7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick backing coat in CM 1:4, finished fair to received the tile, complete all as specified and directed.
Glazed ceramic coloured wall tiles in any type and in any pattern (Pattern consist of combination two or more diffrent colour tiles etc.) in vertical surfaces of size 300mm x 200mm x 6mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick backing coat in CM 1:4, finished fair to received the tile, complete all as specified and directed.
Factory made precast designer paver tiles of different colours, shape and size not less than 300mm x 300mm x 22 to 25mm thick, laid and jointed with grey cement slurry with pigment to match the colour of tile, including 20mm thick screed bed or bedding layer of cement mortar 1:6, compressive strength not less than 250 Kg/Sqm.
Granite stone jet black in colour, machine cut, 15 to 18mm thick in vertical surfaces as in columns, walls etc. fixed with chemical adhesive over and including 10mm thick rendering in CM 1:3 and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including machine grinding including half rounding of exposed edges of granite slab/ stone and polishing complete. Notes :- 1. The granite slab/stone shall be provided in a single piece in one length. The length of each piece shall be exceeding 2.4 mtr and not exceeding 3 mtr and the width of slab shall be exceeding 75cm and and not exceeding 90cm. 2. The granite stone fixed in vertical surface shall be anchored with minimum 2 Nos frame anchors HILTI HRD-C 10 x 100 per 1 Sqm of granite slab. The frame anchors shall be duly drilled and grouted into brick / concrete surfaces for anchoring of the granite stone slabs in vertical surfaces all as directed. The cost of the frame anchors shall deemed to be included in the unit rate quoted by the contractor.
18-20 mm thick Granite stone (table rubbed and polished) in steps, risers, jambs, pillars, window cills, cooking platform bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone over and including 15mm thick screed bed in cement mortar 1:4 finished fair to received the granite including rounding the exposed edges, complete all as specified and directed.
Machine cut kota stone slab flooring, 18-20 mm thick as per sample kept in GEs office, laid and jointed with grey cement slurry mixed with pigment to match the shade of slab, rubbing, grinding and polishing laid over and including 15mm screed layer in cement mortar 1:6 including roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc, and brushing neat cement slurry with 3.0Kg of cement per square metre, complete all as specified & directed.
16mm to 18mm thick, machine cut Kota stone as in riser or steps, skirting, dado and pillars laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and rounding off edges complete with mirror finish polishing, over and including 15mm thick screed bed or bedding layer of cement mortar 1:3 all as specified and as directed.
Plate rack, made out of 1.0mm thick stainless steel sheet, of size 600mm x 750mm x 250mm fixed including shelves etc complete all as specified and as directed.
Taking down chowkhats with shutters (without taking off shutter from the frames) not exceeding 1.50 Sqm each, complete all as specified and directed.
Taking down chowkhats with shutters (without taking off shutter from the frames) exceeding 1.5sqm and not exceeding 4.00 Sqm each, complete all as specified and directed.
Pressed steel frame for door with one or more rebates including necessary lugs, fixing lugs hinges, lock strike plate etc. of size 105mm x 60 mm and made of 1.25mm thick MS sheet, complete all as specified and directed including necessary welding complete and including medium weight 03 Nos of MS butt hinges of size 75mm / 100mm / 125mm and 01 No 50mm Size of medium weight MS butt hinge complete all as specified and directed.
PCC 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) as in back filling of pressed steel door frames and in bed block for holdfast and similar works etc. complete all as specified and directed.
35mm thick 2nd class Hard wood factory made rail and style plain framed, panelled shutter (two panel) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and as directed.
Mild steel framed works such as grills, grating, Gates, etc. With ends of shouldered and/ or riveted or forged into spikes, framed guard bars, barred iron doors, ladders and similar works conforming to Fe-290 or Fe-165 grade, and hung as gates, including pintle hinges, stops, hand made sliding bolts etc including ornamental and intricate design and fixing complete all as specified and as directed.
Butt hinges, medium weight, cold rolled mild steel, 75mm size, complete all as specified and directed.
Mild steel barrel tower bolt of stove enamelled black with bright bolt complete of Size 125mm long complete all as specified and directed.
Mild steel pressed handle oval type stove enamelled black of size 150mm complete all as specified and directed.
Mild steel sliding door bolts, 300mm long, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed, complete all as specified and directed.
Aluminium anodized powder coated frame of size 101.60mm x 44.45mm made out of 1.60mm thick aluminium section, powder coated, fixed to floor / wall with plugs and screws complete all as specified and directed.
Aluminium anodised powder coated window/ventilator sliding shutter, section of size 44.45 x 44.45mm made out of 1.6mm thick aluminium sheet/section including necessary jointing cleats, glazing clips, rubber packing, suitable handle 1 No's in each shutter, tower bolt, hinges 110mm long, anodised aluminium snap beading screws, with and including glazing of top panel of 5mm thick glass sheet with glazing clips of size 19mm x 17mm made out of 0.70 mm thick aluminium section not less than 0.97 KG/RM complete all as specified and directed. Note : Sheet glass to be fitted will be measured and paid separately.
Aluminium anodised powder coated door shutter, rails of size 82.53 x 44.45mm and bottom rail of size 114.30 x 44.45mm made out of 1.6mm thick aluminium sheet / section including necessary jointing cleats, glazing clips, rubber packing, mortice lock having six levers, aluminium body hydraulic door closer of suitable size, handles 2 No's in each shutter, tower bolt, hinges etc., anodised aluminium snap beading screws, with and including glazing of top panel of 5mm thick glass sheet with glazing clips of size 19mm x 17mm made out of 0.70 mm thick aluminium section not less than 0.97 KG/RM bottom panel shall be of 12 mm thick PVC hollow profile panelling pattern as approved complete all as specified and directed. Note: Quoted rate shall be deemed to be included cost of PVC Panels and sheet glass.
Dismantling of structural steel or Mild steel work of any description including doors, gate etc not otherwise provided for complete all as specified and directed.
Dismantling of wrought iron or Mild steel work of any description not otherwise provided for complete all as specified and directed.
Cutting holes into or through brick walls built in Cement mortar and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l, superfacial area exc 150sqcm and n.exc 400 sqcm complete all as specified and as required.
Mild steel work in tubular trusses medium weight including special shaped washer etc. complete including using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240, complete all as specified and directed.
Mild steel plates (plain or chequered) channel, square cut or notched (Ordinary and counter sunk) forming holes, without any attachment as in gusset plates conforming to grade FE.-410-S, complete all as specified and directed.
Mild steel rolled work as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastening and heavy bracket framing (beam, tee, angle, square / rectangle sections, channel or flat section) including distance pieces, cleats etc. confirming to grade FE 410-W (Gde E-250, Quality-A) complete all as specified and directed.
Pre-painted galvalume aluminium zinc coating G.I based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 MPA as in roof covering, fixed with self taping screws, complete all as specified and directed.
Mild steel plain, black sheet 1.25mm thick in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles complete all as specified and as directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc) of any thickness including cover fillets.
4mm thick designer ceiling board fixed with screws as per manufacturers instructions as in false ceiling fixed on and including hot dipped galvanised iron imposed grid with 24mm wide ‘T’ section, imposed flanges which shall be under coated white. The frame shall comprise of main runner made from 0.33mm thick galvanised steel sheet and size of 24 x 32 x 300mm and spaced at 12mm centre securely fixed to the structural soffits by approved hangers at 1200mm maximum centres hangers of GI wire 4mm dia to be fixed by the approved rawl plug, level adjusters and screws etc. The last hanger at the end of each runner shall not be greater than 450mm from adjacent wall flush fitting of 1200mm long cross Tee with double stiching to be inter locked between main runners at 600 mm centre to from 1200 x 600 mm modules cross Tee longer than 600mm modules to be formed by fitting 600 mm long cross Tee. The Tee perimeter wall angle shall be of 0.45mm thick galvanised steel of size 19 x 19mm and 300 mm long of white colour all as per the manufacturers instructions complete all as specified and directed.
Cuting existing steel tubing, 15mm bore for alteration or additions as directed. (Each cut measured)
Screwing existing steel tubing 15 mm bore for alteration or additions as directed.
Taking up or down 15mm bore steel tubing and connection including cleaning for re-fixing or removal to store complete all as specified and as directed.
Steel water tubing medium grade galvanised with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) of nominal bore dia 15mm, complete all as specified and as directed.
Bib tap cast copper alloy CP fancy type screwed down, screwed for 15mm bore iron pipe or for brass ferrule complete all as specified and directed.
Stop valve, cast copper alloy, chromium plated screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions of 15mm bore, complete complete all as specified and as directed.
Vitreous china Orissa pan of pattern, long pan size 580mm x 440mm, with ‘P’ or ‘S’ trap, front or back inlet and integral foot rest complete including lime concrete bedding and connection to drain or outgoing pipe and to flushing pipe, and anti siphon pipe, complete all as specified and directed.
10 litres capacity PVC low level flush cistern of approved make complete with PVC flush pipe and connection to water closet, complete all as specified and directed.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering cutting out existing benching for and forming branch channel (½ round or ¾ section) in cement concrete 1:2:4, type B-1 smooth finished and reforming benching as required for 150mm bore pipe, complete all as specified and directed.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering cutting out existing benching for and forming branch channel (½ round or ¾ section) in cement concrete 1:2:4, type B-1 smooth finished and reforming benching as required for 200mm bore pipe, complete all as specified and directed.
Construction of Septic Tank for 100 users including excavation in any type of soil, foundation in PCC 1:2:4, type B-1 (using 20mm graded crushed stone aggregate) brick work in cement mortar 1:4, RCC (M-25 design Mix) slab including cast iron manhole cover having 6mm plate embedded all around with angle iron frame vent shaft etc, complete all as specified and shown on CE Pathankot Zone TD Drawing No CEPZ/C-TD/013/13 Sheet 1 to 5.
Construction of soakage well 3.00 M internal dia and 4.50m depth including excavation in any type of soil, PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) as in footing brick honey comb/ solid brick masonry in cement 1:4, RCC (M-25 design mix) cover slab filled with brick bats including intercepting chamber screen chamber and disposal of soil, complete all as specified and shown on CE Pathankot Zone TD Drawing No CEPZ/C-TD/013/13 Sheet 1 to 5. Note : 1. During excavation if unexpected water is encountered, the same shall be bailed out / de-watered by the contractor mechanically or manually without any extra cost to the Govt.
Demolition and breaking up of drain pipes 150mm dia (Salt glazed stone ware, AC or reinforced concrete) set in cement mortar complete all as specified and as directed.
Dismantling Cast iron soil waste and vent pipe 75mm and 100mm dia laid in cement mortar complete all as specified and as directed.
Reinforced concrete pipes, class NP3, 150mm dia, laid and jointed and tested complete with collars complete all as specified and as directed.
Reinforced concrete pipes, class NP3, 200mm dia, laid and jointed and tested complete with collars complete all as specified and as directed.
Concrete bed to 150mm bore drain pipes including packing under, and haunching against the sides of pipes after they are laid in cement concret 1:4:8 (Nominal mix) type D-2 using 40mm graded stone aggregate and tested, complete all as specified & directed.
Concrete bed to 200mm bore drain pipes including packing under, and haunching against the sides of pipes after they are laid in cement concret 1:4:8 (Nominal mix) type D-2 using 40mm graded stone aggregate and tested, complete all as specified & directed.
Cast iron soil waste and vent pipe 100mm bore in any length with or without ears with cement joints laid in trenches or in floor.
Cast iron soil waste and vent pipe 75mm bore in any length with or without ears with cement joints laid in trenches or in floor.
Cast iron Bends 100mm, diminsing pieces or tapers with oval access door plates complete all as specified and as directed.
Cast iron Bends 75mm, diminsing pieces or tapers with oval access door plates complete all as specified and as directed.
Cast iron Cowl, suitable for pipe of 75mm, bore complete all as specified and as directed.
Precast cement concrete 1:2:4, type B-1 (Using 20 mm graded crushed stone aggregate) in landings, cover slabs (for manholes etc.) shelves and similar articles with plain faces and set in cement mortar 1:4 including necessary form work, complete, all as specified and as directed.
Preparation old plastered or previously untreated surfaces of walls and applying one coats of white wash, complete all as specified and directed.
Preparation old plastered surfaces of ceiling including brooming down or steel wire brushing, scrapping down smoke, soot, mould, moss and efflorescent salts and treating oil and greasy spots, applying one coat of white wash, complete all as specified and directed.
Preparation of new or previously untreated ceiling surfaces and applying two coats of white wash, complete all as specified and directed.
Preparation of new plastered external surfaces of wall and applying two coats of cement base paint including one coat of cement primer completeall as specified and directed.
Complete removal of existing treatment of wall and applying two coats of cement base paint complete all as specified and as directed.
Complete removal of existing treatment of any description and on old plastered surfaces of wall and applying two coats of oil bound distemper over and including a coat of wall care putty (Birla/JK) of average thickness 2 to 3mm complete all as specified and as directed.
Preparation of new plastered surfaces of wall and applying two coats of oil bound distemper over and including a coat of wall care putty (Birla/JK) of average thickness 2 to 3mm complete all as specified and as directed.
Preparation of new or previously untreated wooden surfaces of any description, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and as directed.
Preparation of new steel surfaces of any description, over 10cm width or girth and applying two coats of synthetic enamel paint, over a coat of red oxide primer, complete all as specified and as directed.
Writing or painting letters or figures (Block, Roman, Italic or Indian) not exceeding 30cm high with two coats of synthetic enamel paint on existing plate of building complete all as specified and as directed.
White ray gate pillar post unbreakable apple design gate light connecting on top of the pillar gate with Mild steel tube for suitable dia for proper fitting and under ground cable connection with 40 Watt CFL lamp complete all as specified and as directed.
E/M Portion
Taking out carefully copper/aluminium point wiring, (Light, fan, socket or power) complete with all fitting, fixtures such as switch socket out let, ceiling rose, holder, regulator, DB's etc. including making good the disturbed surface of wall/floors, complete all as specified and as directed.
Taking down existing unserviceable distribution board, switch fuse unit, enclosure for MCB/ DB (inclusive of MCB's of any type and capacity) and making good the disturbed surface all as specified and as directed.
Taking down existing unserviceable sub main wiring of any size and making good the disturbed surface all as specified and as directed.
Point wiring with multi stranded copper conductor of size 1.5Sqmm PVC insulated unsheathed FRLS cable in and including PVC conduit and accessories of suitable size for concealed wiring including 1.50 Sqmm copper earth wire (green colour) FRLS Cable for one light point or fan point or bell point controlled by one No, one way switch using cable of different insulation colour for colour coding including 3mm thick laminated sheet cover, mild steel sheet or cast iron boxes including cutting chases and making good to disturbed surfaces of wall / floor, complete all as specified and as directed.
All as per the description of Serial Item No 100 here-in-before but for one 3 pin socket outlet 5 Amp independent, complete all as specified and as directed.
All as per the description of Serial Item No 100 here-in-before but for one 3 pin socket outlet 5 Amp on the same board, complete all as specified and as directed.
All as per the description of Serial Item No 100 here-in-before but for one 3 pin socket outlet 15 Amp independent board using cable of size 2.5 Sqmm conduit all as specified and directed.
Switch piano flush type single pole, one way 5 Amp, complete all as specified and as directed.
Switch socket outlet combination universal type, 2 in 1, 3 pin 5 and 15 Amp, piano flush type, 240 volts, complete all as specified and as directed.
Switch socket out let combination universal type, 2 in 1, 2 and 3 pin 5 Amp, piano flush type, 240 volts, complete all as specified and as directed.
Ceiling rose surface bakelite three terminals 240 volts complete all as specified and as directed.
Lamp holder PVC case body of Bakelite with back plate suitable for batten fittings with and including Inverter LED lamp, 6500K, 900lm in white colour of 9 Watt base cap B-22 with poly carbonate diffuser and aluminium heat sink, complete all as specified and as directed.
LED light full glow office compliant fully diffused, recessed mounted 2'x2' LED luminaire 36 Watt, with UGR less than 19, with electronic driver and 2.5 KV voltage surge protaction, short circuit protaction, offering comfortable experience of indoor spaces complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size, complete all as specified & directed. Make. Philips-Cat Part No. RC380BLED36S 6500G4L60WPSDODWHOC/ CG Cat Part No. LCTLRP-36-FO-CDL/ Halonix Cat Part No. HLFPU22-02-36-CW / C&S Cat Part No. LTCRSLM36WATT2X2 or equivalent in Havells/ Osram/ Wipro/ GE Lighting.
Sub main wiring with two single core PVC insulated multistranded un-sheathed FRLS cable of size 4 Sqmm with stranded copper conductor, drawing into and including concealed PVC conduit with continuous PVC insulated multistranded unsheathed FRLS cable earth wire of 2.5 Sqmm dia including taking out unserviceable sub main wiring, complete all as specified and directed. Make of wire : Ploycab /Havells/ Finolex. Note : Two run of 4 Sqmm wire and one run of 2.5 Sqmm wire shall be considered as one unit length.
Sub main wiring with two single core PVC insulated multistranded un-sheathed FRLS cable of size 6 Sqmm with stranded copper conductor, drawing into and including concealed PVC conduit with continuous PVC insulated multistranded unsheathed FRLS cable earth wire of 4.0 Sqmm dia including taking out unserviceable sub main wiring, complete all as specified and directed. Make of wire : Ploycab /Havells/ Finolex. Note : Two run of 6 Sqmm wire and one run of 4.0 Sqmm wire shall be considered as one unit length.
High speed Wall mounted Fan, 400mm sweep, single phase, 230 volts 50 Hz AC, Air delivery not less than 5000 cubic metre per hour, 1300 RPM, motor protacted with thermal overload protactive device, copper wound, aerodynamic resin blades having tilt mechanisum, 3 speed rotary switch control complete all as specified and as directed. Make : Orient, Model Wall 43 or equivalent model of Havells / Orient / Usha.
MCB Four Pole 63 Amp, C Curve, 10 KA breaking capacity, 415 volts 50Hz AC supply, complete all as specified and as directed.
MCB SPN 6 to 32 Amp, 240 volts 50Hz,10 KA, C Curve, AC supply, complete all as specified and as directed.
MCB SP 6 to 32 Amp 10 KA, C Curve, complete all as specified and as directed.
MCB DP 6 to 32 Amp, 240 volts, 50Hz, 10 KA, C Curve, AC supply, complete all as specified and as directed.
Sheet metal enclosure factory made, IP-43, double door for DB 240 volts with 200 Amps rated bus bar SPN 4 Way, complete all as specified and as directed.
Sheet metal enclosure factory made, IP-43, double door for DB 240 volts with 200 Amps rated bus bar SPN 8 Way, complete all as specified and as directed.
Supply and fixing of storage water heater (Geyser), vertical type, of 50 ltr capacity of inner tank, outer tank, syphon assembly, thermostat heating element, safety valve etc complete all as per manufacturer design and specifications including making of all fixing arrangements complete having BEE Five Star Rating including grouting of nuts and bolts and necessary PCC work as specified and directed by Engineer-in-Charge. Make : HAVELLS Model No. : Monza DX Cat Part No.GHWAMGSWH050 or equivalent model of make as per list of make in particular specifications.
Supply, installation, testing and commissioning of Evaporative air/desert cooler (GI coated metal body not less than 16 gauge), 230volts, 50Hz, single phase, complete with fan of dia 18 inch sweep with motor (GE/CG/Almonard make) 1440 rpm single phase with speed control with three position ( low /medium/high) motor. And fitted with water proof cooler pump of sufficient pumping height and delivery to keep the filter in moist condition . The cooler shall be fitted with filter pads of non decaying filter material. The cooler shall be capable for cooling not less than 2250 cubic feet. The overall dimension of the cooler shall not be less than 660mm width (measured along discharged grill side), 900mm height and 660mm in depth. The cooler tank capacity shall be 72 ltrs. The cooler shall be internally prewired and including back filling arrangement and with connecting cord 3x2.5 sqmm copper flexible cable of 2.5 mtrs length fitted with 3 pin moulded plug top (ISI marked) of 5/6Amp complete all as specified and as directed. Make :Bajaj/Usha/Khaitan
Supply, installation, testing and commissioning of room window air conditioner fitted with thermetically sealed rotary compressors operating on refrigerant R-22/R-410A suitable for operation on 230 volts 50Hz single phase AC power supply capable of performing cooling, dehumidifying (moisture removal -1.7 ltrs / hr ) air circulation (indoor flow - 450CFM) and filtering and featuring auto restart and with wireless electronic remote control, electrostatic and deodorizing filter (air filters 90% efficiency filtering down to 10 microns size, washable HDPE air filters), noise level not more than 45db at 1.5 m distance. Fin type condensor and fin type evaporator should be made of copper, ball bearing bush needed for compressor motor, cooling capacity 4500 K Cal per hour ( 1.5 Ton), BEE 5 star rated complete all as specified and as directed. Make: Blue star model - 5W18GA or equivalent model of VOLTAS/CARRIER.
Voltage stablizer automatic boost / buck transformer copper wounded for low and high voltage correction complete of electronic transformer relay suitable for correction on single phase 50 Hz supply with voltmeter ampere meter input voltage 140 to 280 volts and output voltage stablized between 220 volt +/- 9% calibration accuracy +/- 03% of capacity 5 KVA, complete including low high cut off and intelligent time delay with digital display all as specified and as directed..
Single Pole and neutral powder coated sheet metal deep drawn enclosure with two pin and earth plug and socket including insulated neutral link adjustable din rail and connecting link with one single pole and neutral MCB 32 Amp and 240 Volts, 10 KA, C series complete all as specified and as directed.
Factory made epoxy powder coated Distribution board vertical TPN 4 ways (TPN MCB DB) with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amp copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removable gland plates with Knockouts and suitable for one FP-MCCB 160/250 Amp as incomer and SP/TP MCBs outgoing complete all as specified and confirming to IS : 8623. Make: C&S, Cat No. CSDBTPNVDD04S or equivalent model of Schneider/Legrand.
Excavating in trenches in any type of soil, not exceeding 1.5m wide and not exceeding 1.5m in depth for electric poles / stay foundation and under ground electric power cables, CI /GI pipes etc and getting out, complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in any type of soil, complete all as specified and as directed.
Removing excavated surplus material to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point, complete all as specified and as directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 16 Sqmm 4 core complete all as specified and directed. Make : Havells / KEI / Polycab
XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 16 Sqmm 2 core complete all as specified and directed. Make : Havells / KEI / Polycab
Supply and laying brick covering with width equal to length of bricks as mechanical protection to underground cable using old size sub class 'B' bricks, laid flat size 230mm x 115mm x 75 mm, all as specified and as directed.
Sand cushioning to underground cables provided with a layer of sand 8cm thick before laying the cable in trenches and 15cm thick after laying the cable in trenches complete, all as specified and as directed. Note : The punned thickness 18cm shall be considered for measurement purpose.
Steel pipe galvanised light grade 40 mm bore laid in trenches or under ground/floor or road of fixed with pole for protection of cable including GI clamps with bolts nuts and washers complete all as specified and directed.
Earthing complete with galvanized mild steel earth plate electrode size 600mm x 600mm x 6mm thick buried directly in ground (preferably in vertical position) earth pit not less than 2.25 meter below normal ground level with top edge of the earth plate not less 3 meter (BGL) connected to galvanized iron earth lead wire 4mm dia by means of bolts, nuts, check nut and washer of galvanized iron including PCC pit in RCC 1:2:4 type B-1, precast RCC cover with suitable handle, excavation and earth work in any type of soil, 20mm bore “medium grade” galvanized iron water tubing fixed with cast iron funnel and wire mesh and 15mm bore “light grade” galvanized iron protection pipe for earth lead wire upto 5m length, charcoal, common salt, complete all as shown in EP No 3 of SSR 2009 Part-I, connected to test point complete, all as specified and testing on completion.
NARESH KUMAR AND COMPANY
M/S Sudagar Mal
Bidder Name
M/S Sudagar Mal
NARESH KUMAR AND COMPANY
ASHISH CONSTRUCTION COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .