Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.8 CrAccepted-AOC | ₹17.8 Cr | L1 | Accepted-AOC lowest bidder |
| 2 | L2₹18.2 CrRejected-Finance | ₹18.2 Cr | L2 | Rejected-Finance being other than lowest bidder |
| 3 | L3₹19.2 CrRejected-Finance 00 00 NAPASAR ROAD NENO KA BASS BIKANER RAJASTHAN BIKANER RAJASTHAN 334022 UDYAM RJ 08 0001676 | BIKANER | RAJASTHAN | 334022 | ₹19.2 Cr | L3 | Rejected-Finance being other than lowest bidder |
| 4 | L4₹19.3 CrRejected-Finance | ₹19.3 Cr | L4 | Rejected-Finance being other than lowest bidder |
| 5 | L5₹19.9 CrRejected-Finance 1630 SECTOR 7C CHANDIGARH 160019 | CHANDIGARH | CHANDIGARH | CHANDIGARH | 160019 | ₹19.9 Cr | L5 | Rejected-Finance being other than lowest bidder |
Tender Value
₹19.4 Cr
EMD Value
₹13.0 L
Closing Date
20 Jun 2023, 6:00 pmClosed
CE AF Udhampur Zone
HQ CE AF Udhampur Zone
CA NO CEAFU-15-2022-23 PROVISION OF EXTERNAL SERVICES FOR AMS AT AF STN PATHANKOT
2023_MES_586962_1
CEAFU-15/2022-23
Open Tender
Civil Works
609 days
Pathankot
aS PER TENDER DOCUMENTS AND AS PER POLICY IN VOGUE
9 documents required · 9 mandatory
₹3,000
GE AF Pathankot
₹13.0 L
Yes
Udhampur
31 Jul 2023
25 Mar 2023
28 Jun 2023
25 Mar 2023
20 Jun 2023
13 Jun 2023
25 Mar 2023 - 5 Apr 2023
10 Apr 2023
Amount
SCHEDULE `A' PART-I (BUILDING WORK) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
Construction of Parking Shed of size 46000mm x 4500mm and 1800mm wide ramp, RCC framed construction, RCC roof all as shown on drawings and as specified.
Construction of Parking Shed of size 18500mm x 4500mm and 1800mm wide ramp, RCC framed construction, RCC roof all as shown on drawings and as specified.
Construction of Parking Shed of size 9200mm x 4500mm and 1800mm wide ramp, RCC framed construction, RCC roof all as shown on drawings and as specified.
Construction of Guard Rest room for 03 persons, RCC framed construction, RCC roof all as shown on drawings and as specified.
Construction of Sentry Post, RCC framed construction, RCC roof all as shown on drawings and as specified.
Construction of POL Store, RCC framed construction, RCC roof all as shown on drawings and as specified.
Construction of 3D CAR ramp (60.8 m X 6 m), partly double storey, RCC framed construction , RCC roof, Aluminium joinery, Ceiling, mild steel railing all as shown on drawings and as specified. Note 1 : Drawing No CEAF/AR/608/2023/3D CAR (BW) Sh 1/2 and 2/2 dated 22.05.2023 shall be applicable for lumpsum part. Note 2: The total length of the 3D CAR ramp is 110 RM (Approx). The middle 60.80 running metre (crumple to crumple) as shown in drawings mentioned at Note 1 above is included in lump sum cost. All the items except earth filling and floor for the sloping portion is included in the lumpsum cost. The remaining length of 25 running metre (approx) on each side with retaining wall, earthwork in filling, flooring and MS railing is included in measurable schedule for RCC retaining wall as item rate.
Construction of Static Water Tank 45000 Litre capacity RCC construction , all as shown on drawing and specified.
Construction of Sub Staion Bldg RCC framed construction , RCC roof all as shown on drawing and specified.
Total amount of Schedule 'A' PART-I (BUILDING WORK)
Total amount of Sch 'A' PART-II (Sec-I) (INTERNAL ELECTRIC SUPPLY WORKS)
SCHEDULE `A' PART-II (SEC-II) (INTERNAL ELECTRIC SUPPLY WORKS) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
Supply and fixing MCB Single Pole 1 to 2 Amps rating 240 Volts, 10KA 'C' curve miniature circuit breaker complete with connection testing and commissioning complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing MCB Single Pole 6 to 32 Amps rating 240 Volts, 10KA 'C' curve miniature circuit breaker complete with connection testing and commissioning complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing Bracket made out of GI light grade pipe of size 40 mm dia 1.5 mtr long bend to an angle of 120 degree with 02 Nos MS clamp 50mm x 5mm and 04 sets of nuts,bolts and washers painting with two coats of synthetic enamel paint over a red oxide primer complete all as specified and as directed by Engr-in-charge.
Supply & fixing Telephone Jack RJ-11 complete with all accessories complete all as specified and as directed by Engr-in-charge.
M&L Telephone Cable RJ-11 complete all as specified and as directed by Engr-in-charge.
S & F LED batten surface / wall mounted with specially designed powder coated aluminium housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired up to terminal block, power consumption <20W, luminaire lumen >2000 lm, system efficiency of > 120 lumens/W, LED Make: Nichia/ Cree/ Everlite / Eclison/ Osram/ Lumiled, with LED binning as per ANSI Bin C78.377A, photo biological safety report as per IEC624718 & electrical insulation class 1, Ingress protection IP 20, colour rendering index CRI>80, temp range 0 to 450C, driver efficiency>85%, power factor > 0.9, THD <20% as per IEC 61000-3-2, colour temp -6500K, surge protection 2.5 KV, 50,000 burning hrs (min) as per L7O criteria, two stages isolated constant current operated driver with range 150-270V AC and safety extra low voltage safe level < 60 V DC as per IEC standard with LM70 & LM 80 certification all as specified and directed.
S & F 2ft x 2ft recess mounted full panel LED luminaire with white powder coated housing acting as heat sink and frame in CRCA sheet, high efficiency LED grade diffuser , in built electronic driver duly wired up to terminal block, power consumption< 36W, luminaire lumen > 3500lm and system efficiency >120lm/W, CRI>80, LED Make:- Nichia/ Cree/ Everlite / Eclison/ Osram/ Lumiled with LED binning as per ANSI Bin C78.377A, photo biological safety report as per IEC624718 & electrical insulation class 1, colour temp -5700K, Ingress protection IP 20, , driver efficiency >85%, 50,000 burning hours (min) as per L70 criteria, ambient temp 0 to 500C, power factor >0.95, THD < 10% , surge protection in CM -3 KV, two stages isolated constant current operated driver with range 150-270V AC and safety extra low voltage safe level <60V DC as per IEC standard, with LM79 & LM80 certification all as specified and directed.
S & F LED mirror light fitting /fixture surface / wall mounted with specially premium quality material with integrated LED designed powder coated aluminium housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired up to terminal block, power consumption <12W, lifetime upto 2500 hours with IP -20 class II protection 220-240 volts with total lumen ficture output of 420 with diffusing light effect with stylish heritage type looks and finish all as specified and directed.
Supply and fixing of Exhaust fan 200mm sweep, heavy duty motor with double ball bearing, PVC body with PVC louvers, 900 RPM, With bird guard to protect the fan in running condition, AC, single phase, 230 Volts, including connection with 1.5 Sqmm mutistrand copper conductor flexible wire from ceiling rose, including outside louvers with proper hole, and necessary fixing arrangement and making good to disturbed surface complete all as specified and directed.
Sub Total amount of Sch 'A' PART-II (SEC-II) (INTERNAL ELECTRIC SUPPLY WORK)
Total amount of Sch 'A' PART-III (SEC-I) (INTERNAL WATER SUPPLY WORK)
SCHEDULE `A' PART-III (SEC-II) (INTERNAL WATER SUPPLY WORK) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
Supply and fixing C P health Faucets with flexible tube 15mm dia for EWC including all connection omplete all as specified and as directed by Engineer-in-Charge.
Total amount of Sch 'A' PART-IV (PLUMBING WORK)
Total amount of Sch 'A' PART-V (SEC-I) (AIR CONDITIONING AND REFRIGERATION WORK)
SCHEDULE `A' PART-V (Section-II) (AIR CONDITIONING AND REFRIGERATION WORK) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
Supply and fixing frost free refrigerator electric driven 220-230 volts single phase with BEE 3 star rating with Voltage stabilizer free operation with Digital inverter technology double door having a gross volume of minimum 310 ltrs and storage volume of 229 Ltrs with minimum 72 ltrs of freezer capoacity with freestanding type with 1 year comprehensive warranty on product and 10 years on compressor with steel metal body inclusive of all internal shelves ,led bulb,mannuals inclusive of all accessories a single unit all as specified and directed.
Supply and fixing frost free refrigerator electric driven 220-230 volts single phase with BEE 3 star rating with Voltage stabilizer free operation with direct cool technology single door with having a gross volume of 195 ltrs and storage volume of 162 Ltrs capacity ,freezer capacity of 33 Ltrs with freestanding type with 1 year comprehensive warranty on product and 10 years on compressor with steel metal body inclusive of all internal shelves ,led bulb,mannuals inclusive of all accessories a single unit all as specified and directed
Supply and fixing Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 Volts to 250 Volts with output voltage stabilized at 230 Volts with accuracy of ± 2.5% and of capacity 2 KVA complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 Volts to 250 Volts with output voltage stabilized at 230 Volts with accuracy of ± 2.5% and of capacity 5 KVA complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 Volts to 250 Volts with output voltage stabilized at 230 Volts with accuracy of ± 2.5% and of capacity 1 KVA complete all as specified and as directed by Engineer-in-Charge.
Rapid 4 Modular 1 Plug in socket switch for AC with shutter in three mode ON-OFF-ON including 5 Pin Multi socket 240 volts single phase 50 HZ .of 25 amps current capacity complete all as specified and as directed by Engineer-in-Charge.
Rapid 4 Modular 1 Plug in socket switch for AC with shutter in three mode ON-OFF-ON including 5 Pin Multi socket 240 volts single phase 50 HZ .of 16 amps current capacity complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing for outdoor unit mounting brackets Factory made heavy duty floor anchored made out of 2mm MS sheet bent to shape duly slotted for adjustment, powder coated GI/ aluminium stand for fixing Outdoor Condensing Units on the roof (or on the wall as required) of the room with serrated complete with s/sdash/hole fastener's of adequate length for fixing the bracket to wall or on roof for mounting of Out Door unit (Set of Two) complete all as specified and as directed by Engineer-in-Charge.
Sub Total amount of Sch 'A' PART-V (SEC-II) (AIR CONDITIONING AND REFRIGERATION WORK)
Total amount of Sch 'A' PART-VI (LIGHTNING PROTECTION WORK)
Total amount of Sch 'A' PART-VII (Section-I) (ROAD/PATH/CULVERTROAD FURNITURE WORK)
Sch 'A' PART-VII (Section-II) (ROAD/PATH/CULVERT/ROAD FURNITURE WORK) Note: This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
Material and labour for applying retroreflective thermoplastic road marking paint white or yellow with reflective sign glass beads @ 250 gms per Sqm area confirming to BIS specifications for lines, dashes or arrows letters etc over bituminous surfaces/ pavments exceeding 10 cm width applied by machine as per manufacturers instructions complete all as specified and as directed by Engineer-in-Charge.
Speed breaker made out of ABS engineering plastic, dynamically designed of size 250mm x 350mm x 50mm high, fitted with 4 Nos higly reflective reflectors, 02 Nos on each side including 04 Nos of fixing nails along with cement mortar bedding complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing of Double legged Information sign board of size 1044mmx900mm and leg length 600mm made out of 2mm thick aluminium sheet confirming to IS 736 to be covered with Hi-intensity grade retro reflective film of shade as approved including border of 20mm thick as per IRC standards and letter of any type and colour (size and colour as approved) to be fixed to sheet with suitable adhesive, aluminium sheet fixeed to structural steel frame work made of MS square pipe 32mm dia heavy duty fixed with nuts, bolts/revets ensuring sagety against removal of plates MS tubular pipe frame fixed to two vertical posts made of 50mm size MS square pipe heavy duty (height from ground level to bottom of sheet is 2m to 4m as required as per site constraints), pipe should be cover with hi-intensity grade retro reflective sheeting and at least 600mm in ground level for grip to sagety angainst over turining with cross of flat iron (FI 40x5) of 230mm long complete in all respect including two coats of synthetic enamel paint over a coat of red oxide primer and including excavation and earth work in any type of soil and grout in PCC 1:3:6 type C1 (using 20mm graded crushed stone aggregate) complete all as specified and directed by Engr-in-Charge.
Supply and fixing of 60cm dia outdoor Convex mirror light weight adjustable and extendable aluminium handle with tripod with ball bearing castor wheels incl stainless steel stand complete all as specified and directed by Engr-in-Charge.
Material and labour rubber mooulded vibrator system concrete interlocking paver block with gray cement and pigment any shape and size conforming to IS 15658-2006 of 100 mm thickness M-50 Grade complete all as specified and as directed by Engineer-in-charge.
Sub Total amount of Sch 'A' PART-VII (Section-II) (ROAD/PATH/CULVERT/ROAD FURNITURE WORK)
Total amount of Sch 'A' PART-VIII (Section-I) (SEWAGE DISPOSAL WORK)
Sch 'A' PART-VIII (Section-II) (SEWAGE DISPOSAL WORK) Note: This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
Supply and fixing of LLDPE tank for 10 users including vent shaft and other necessary fixing arrangment, complete all as specified and directed by Engr-in-Charge. MAKE: SINTEX, CODE NO PWTS-AM-300-01 OR EQUAL APPROVED MAKE OF COMFORT POLYMERS OR POLYCON)
150 mm bore of pipe, class DWC HDPE pipe laid & jointed complete with collars complete all as specified and directed by Engineer-in-Charge.
Sub Total amount of Sch 'A' PART-VIII (Section-II) (SEWAGE DISPOSAL WORK)
Total amount of Sch 'A' Part-IX (AREA DRAINAGE WORK)
Total amount of Sch 'A' PART-X (Section-I) (FENCING AND GATE WORK)
Sch 'A' Part-X (Section-II) (FENCING AND GATE WORK) Note: This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
Barbed razor tape concertina coil SG hot galvanised spring tensile wire manufactured by M/S Special Steel Ltd or M/S Super Fence or M/S Global Engg or other equivalent approved make of UTS 145 to 150kg/mm2 and dia of coil when stretched 600 mm having minimum number of circles 10/RM Minimum number of clips 25/RM & minimum weight of coil 1.625 kg/RM (when streched) hot dip galvanised complete all as specified and directed by Engr-in-Charge.
Barbed razor tape concertina coil SG hot galvanised spring tensile wire manufactured by M/S Special Steel Ltd or M/S Super Fence or M/S Global Engg or other equivalent approved make of UTS 145 to 150kg/mm2 and dia of coil when stretched 1000 mm having minimum number of circles 10/RM Minimum number of clips 25/RM & minimum weight of coil 1.625 kg/RM hot (when streched) dip galvanised complete all as specified and directed by Engr-in-Charge.
Construction of steel RCC Pillar ( Size 5.5 M wide x 3 M high ) including angle iron frame, guide rails, steel paiting, plastering to pillars , camouflage painting, excavation and earthwork incl removal of surplus soil all as per Drg No CEAF/TD-56/3 sheet No 1/3 to 3/3.
Sub Total amount of Sch 'A' PART-X (Section-II) (FENCING AND GATE WORK)
Total amount of Sch 'A' PART-XI (EXTERNAL WATER SUPPLY WORK)
Total amount of Sch 'A' -XII (Section-I) (EXTERNAL ELECTRIFICATION WORK)
Sch 'A' Part-XII (Section-II) (EXTERNAL ELECTRIFICATION WORK) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
Supply, installing, testing and commissioning indoor type floor mounted step down transformer, 11KV/433 Volts (at no load) AC 3 Phase 50 Hz, 750 KVA Capacity, core type, double copper wound oil immersed, Oil Natural- Air Natural (ONAN) cooled, with external cooling tubes, delta connected on primary side (HV) and star connected on secondary side (LV) in accordance with vector group DYn-11 with Neutral brought out on secondary side (LV Side) and having tapings at 2.5% and ± 5% on HV side to be changed by means of hand operated off load tap changer gear. The maximum temperature rise should not exceed 45°C in oil and 55°C in HV/ LV winding when measured by resistance method after continuous full load run on an ambient temp of 40°C. The transformer shall be as per IS-1180(Part-I) 2014 EEL-3 standards of BEE and shall comprise of the following:- (Note: For site Tech Flight complex i.e Site V) (1W + 1S) (i) No load voltage ratio: 11/0.433 KV, (ii) No. of Phases / Freq.: 3 Phase/50 Hz, (iii) Type: Core type, double copper wound, (iv) Cooling: ONAN, (v) Vector group: DYN 11, (vi) Temperature rise (oil winding): 50/55, (vii) Taps on HV for HV variation: -7.5% to + 7.5% in steps of 2.5% each (on circuit type), (viii) Termination (HV): Air filled cable box suitable for 11.00 KV, XLPE cable, (ix) Termination (LV): Air filled cable box suitable for 1.1 KV, XLPE cable, (x) Conservator with drain valve and level gauge. (xi) Oil level indicator, (xii) Silica gel breather with oil seal, (xiii) First filling of filtered oil as per IS –335 including makeup fill during installation of transformer plus 10% extra oil.
(xiv) ON circuit switch, (xv) Lifting lugs, (xvi) Earthing terminals - 2 Nos, (xvii) Air release plug, (xviii) Inspection cover, (xix) Top filter valve – 1 No, (xx) Drain valve, (xxi) Oil temperature and winding temperature gauge with max pointer (xxii) Rating and diagram plate, (xxiii) Bi-directional plain/flanged rollers, (xxiv) Disconnecting facility for HV cable box, (xxv) Bucholz relay with WTI and OTI alarm, (xxvi) Marshalling box and HV fuse unit to be provided by OEM to protect Primary windings from overload of other faults, (xxvii) All the Items like Exposive vent, One No 100 mm dia, dial type thermometer, vapour pressure release type having range 0-200º C with metal guard having maximum perimeter temperature reading indicator with re-setting device. (xxviii) First filling of new and unused transformer oil, IS-335 marked filtered and tested upto 40 KV dielectric strength at 2.5 mm air gap between testing electrodes. (xxix) Thermometer pocket on tank cover, Oil level guage, Oil drain filter valve, lifting lugs, oil filling hole with cap/ plug with connection plate complete, Air release valve plug and four Nos. plain solid vast steel detachable rollers, (xxx) Two earthing terminals on tank cover to facilitate fixing of 50X6 mm galvanised iron earth strip for earthing of body. (xxxi) Extra bushing for neutral, in the LT cable box for providing independent set of earthing for neutral are per standard accessories as per the standard in vogue.
All as per item no 19.01 here-in-before above but of capacity 250 KVA outdoor type except provision of Bucholz relay complete all as specifed and as directed.
All as per item no 1.00 here-in-before above but of capacity 63 KVA outdoor type except provision of Bucholz relay complete all as specifed and as directed.
Construction of Platform with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 mm thick in foundation, brick work in CM 1:6 with sub class "B" old size brick, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc of size 3000mm x 2500mm x 1200mm with fencing foldable upto 1.5m height, gate with locking arrangements using GI wire mesh, GI wire 4mm dia, angle iron, MS plate etc, complete all as specified and shown in drawing No. CEPZ/ TD-504
Supply, installation, testing and commissioning of indoor automatic/servo voltage controller three phase, 50Hz (conforming as per BIS 9815 : Part 1: 1994 reaffirmed 2009) Oil cooled of 750 KVA, unbalanced type, copper wound, digital display type, Relay free smooth and silent operation with first filling of Transformer oil having following specification :- (i) Input voltage 340-480V or as per ground requirement, (ii) Output voltage stabilized at any designed/desired voltage 415 +/- 1% adjustable, (iii) No distortion in wave form, (iv) Response time shall be instantaneous (in mili seconds), (v) Sensitivity (+_ 1%), (vi) Rate of correction 8 volt/second for single phase and 20 volt/second for phase to phase, (vii) No load losses less than 0.5%, (viii) Full load losses less than 2.0%, (ix) Duty cycle continuous 24 x 7, Efficiency more than 95%, (x) Type of load 3 Phase, unbalanced type, (xi) Digital display voltmeter and amp meter of suitable rating Protections, (xii) Over load/short circuit protection, (xiii) High/low voltage cut off, (ix) By pass arrangement in case of emergency, (xv) Single phase and phase reversal cut off protection
Supply, installation, testing and commissioning of indoor automatic/servo voltage controller of cap 250 KVA three phase, 50Hz(confirming as per BIS 9815 : Part 1: 1994 reaffirmed 2009) oil cooled of 250 KVA, unbalanced type, copper wound, digital display type,Relay free smooth and silent operation with first Filling ofTransformer Oil having the following specification :- (i) Input voltage340-480V, (ii) Output voltage stabilized at any designed/desired voltage 415 +/- 1% adjustable (iii) No distortion in wave form, (iv) Response time not to exceed 10mille seconds, (v) Sensitivity ( +1%), (vi) Rate of correction 8 volt/second for single phase and 20 volt/second for phase to phase, (vii) No load losses less than 0.5%, (viii) Full load losses less than 2.0%, (ix) Duty cycle continuous 24 x 7, Efficiency more than 95%, (x) Type of load 3 Phase, unbalanced type, (xi) Digital display voltmeter and amp meter of suitable rating Protections, (xii) Over load/short circuit protection, (xiii) High/low voltage cut off, (ix) By pass arrangement in case of emergency, (xv) Single phase and Phase reversal cut off protection.
Supply and erect swan neck type steel tubular pole 09 meter complete with cast iron base plate, finial taper plug, bolts, nuts, screws as specified type 410 SP-31 (9.0 mtr long) and erecting in position all as specified and directed incl one coat of red-oxide zinc chrome primer and two coats of aluminium paint on surfaces exposed to view and making 30cm wide strips (total 5 Nos) with yellow and black paint alternately on external surface above PCC benching including numbering with fluorescent yellow paint and painting the exposed portion with two coats of aluminium paint over a coat of red oxide primer and internally through out plus embedded portion with two coats of black bituminous paint over a coat of red oxide primer all as specified and directed (Note: Earth work, and PCC shall be measured and paid for separately).
Supply and Fix sheet moulding compound (SMC) junction box for and including three phase and neutral bus bar and MCB SPN 06 Amps, 250 Volts 50 Hz, 15 KA for control of street lights mounted on ploe with the provisions of cable entry and exit of size 280mmX170mmX130mm all as directed by the Engineer-in-Charge
Supply, Installation, testing and commissioning High galvanized mast light of 16 meter in two sections, 3 mm section thickness, top dia 150 mm, bottom dia 360 mm with High tensile steel as per BN-EN10025 Grade S355 with IS 2062 with plate thickness of 4 mm at top and 5 mm at bottom with cross section of mast in polygonal (20 sides) with top section of 8.250 Meters and bottom with 8.250 meters with base dia 360 mm and top dia 150 mm with hot dipped galvanized (single Dip metal protection for mast section as per BS EN ISO 1461 with IS 2309 Lightening protection and to with stand max wind speed(as per(IS 875-Part III1987) with 50 M/sec and max. gust speed time of 3 seconds at height of 10 meter above ground with RCC RAFT footing M-20 as per manufacturer design and site condition with a safety factor of IS 456 and IS 875 with complete foundation bolts of 12 Nos of 6.8 Grade steel of dia 30mm and length 850 mm exposed portion should be hot dip galvanized including suitable winch system for lower of the mast with double drum system in gear ratio of 50:1 to have a cap of SWL 500 Kgs with
motor operated and with manual arrangement to incase of power failure with self-lubrication oil bath system of SAE-90/140 type oil including AISI 316 6 mm SS rope of 7/19 for 3 Nos of 6 mm for lantern carriage and 2 nos of 6 mm for double drum winch with breaking load cap of 2350 Kgs per SS wire rope including flexible copper 5 core 2.5 Sq.mm PVC insulated / EPR insulated PCP sheathed with integral 1.5 HP motor single speed and reversible operation of 415 volts /240 volts suitable for 08 No. 250 watt LED lights symmetrically fitted along with their control gear and having two point suspension system with stainless steel wire rope of 6 mm dia 97/19 gauge and double drum winch with luminaire mounting arm, pulley assembly, aviation obstruction light, lightning arrester spike including RCC foundation as per height complete all as specified and directed. The Height of Mast-16.00 Meters with BSEN10025 type material with refer to IS1944-5(1981).The Job includes LT panel of outdoor type with stand mounted feeder pillar made out of 3.15 mm thick CRCA sheet with powder coating suitable size to accommodate the following :-
(i) Aluminum bus bar 3 phase 4 wire-200 amps -01 set (i) MCB TPN 63 amps-01 nos (iii) MCB TPN 32 amps-02 nos (iv) power contactor 32 amps TP -02 nos (v) DOL starter with 32 amps relay and contactor complete -01 nos (vi) timer switch single dial for automatic operation -01 nos (vii) suitable angle iron frame made of 40x40x6 mm angle with PCC 1:2:4 with and the automatic switching of luminaries, power tool control with 2 no 9 A contactors and raise lower push button, Incoming 35sq. mm and out going 16 & 25 sq. mm terminals copper wired all as requirement at site complete all as directed. The earth work for Construction of shallow foundation with M20 grade concrete for the high mast considering the safe soil bearing capacity at site as 10 T/Sqmtr at 2 metre depth with all materials and labour complete all as specified and as directed by Engineer-in-charge.
Supply, installation, testing & commissioning of factory assembled silent Diesel Engine driven generating set 1500 RPM of capacity 62.5 KVA, 3 phase, 4 wire, 415 volt, 0.8 PF (MSL complete with control panel including integrated powder coated accoustic enclosure as per CPCB regulations and duly certified by agencies / labs designated by CPCB for noise and sound pollution level, etc floor mounted including PCC foundation as per manufacturer's instructions complete all as specified and directed and comprising of the following :- (Note: 01 No for FU 'A', 1 No for FU 'B' and 1 No for 3D CAR i.e. Site II, III & IV)
(A) DIESEL ENGINE of required capacity for driving alternator of capacity 62.5 KVA in the ambient conditions of Pathankot (Punjab) multi cylinder, vertical type, 4 stroke, water cooled, electric start conforming to IS : 10001/10002/BS-5514 for continuous running capable of taking 10% overload for one hour in 12 hours complete and comprising of the following: - (i) Radiator cooling (ii) Radiator fan with guard (iii) Flywheel with starter ring (iv) Air cleaner oil bath type (v) Vacuum indicator (vi) Electronic governor class 1A (vii) Exhaust silencer (viii) Fuel filters & fuel pipelines including fuel flow meter (ix) Fuel injection pump (FIP) (x) Fan & water pump assembly (xi) Lub oil filter & Pump (xii) Oil filter (xiii) Exhaust gas driven turbo charger (xiv) Lub oil cooler (xv) Engine maintenance manual with spare parts list (xvi) Suitably designed accoustic enclosure as per CPCB regulations. (xvii) Engine safety shut down system against low lub oil pressure and high water pressure (xviii) Electric starting system with battery charging alternator and axial type starter motor including adequate number of high capacity maintenance free lead acid battery 12 volts 140 AH including interconnecting cables/ leads with terminals complete with starting/ stopping switch, volt meter etc - 01 Set.
(B) ENGINE INSTRUMENT PANEL digital type indicating the following: - (i) Starting switch on/off (ii) Water temp guage (iii) Hour meter cum RPM indicator (iv) Lub oil pressure (v) Lub oil temperature (vi) Battery charging meter (vii) Safety alarm against high water temp and lub oil pressure (C) ALTERNATOR Shall be self excited, self regulated, brushless for 62.5 KVA continuous operation at the speed of 1500 RPM at 415 volts, 50Hz , three phase four wire system with advance electric voltage regulator to ensure high voltage accuracy with ± 1% with class "H" insulation and SPDP enclosure directly coupled with engine through flexible coupling and confirming IS- 13364 complete - 1 No. (D) Common fabricated base frame for engine & alternator made from structural channel, jerk proof PCC 1:2:4 type B1 foundation including adequate number of suitable anti-vibration pads all as per the recommendation of the manufacture- 01 No (NOTE:- Cost of suitable size of PCC foundation is deemed to be included in the unit rate quoted by the contractor. (E) Fuel tank fabricated out of 14 SWG MS sheet of capacity not less than 8 hrs continuous operation, inside canopy, with fuel level guage, drain plug, locking arrengements, etc with & including GI pipe connections duly laid as per engineering practice complete. (F) AMF CONTROL PANEL: ” Supply, fabrication,fixing commissioning and testing, factory made, floor mounted, cubical automatic mains failure panel suitable for 63 KVA DG set, fabricated using 16 guage thick CRCA sheet with hinged type with front and back side opening mounted over base frame and supported on both sides on base frame rubber pads of 6 mm- thickness shall be provided between base frame and control panel support, powder coated painting, suitable rated bus bar, internal wiring with control fuse, provn of connecting incoming & outgoing leads/bus bars as approved with and including the following accessories as under:-
(i) Master switch for auto/ manual/ reset/ off - 01 No (ii) Ammeter digital type 96x96 mm to read 0 - 400 amps with CTs 1 set of 3, aux supply 230 volts, AC, accuracy class 1.0 (iii) Voltmeter digital type, 96 x 96 mm to read 0 - 500 volts aux supply 230 volts, AC, accuracy class 1.0 (iv) Digital frequency meter -01 No. aux supply 230 volts, AC. (v) Push button start, stop/ reset - 01 No (vi) Set of lamp for indicating load on , low pressure, high cylinder temperature, load on mains, set fails to start, low oil pressure etc. (vii) All functional requirements in Auto mode are to be achieved through Microproceesor based AMF controller. (viii) 4 X 20 Character back lit LCD on front fascia of showing various parameters of mains and DG viz 3 ph. Voltage , 3 ph current,frequency, KWH of mains,KWH of generated by DG,Months wise Energy register,PF of all 3 phases,DG running hours, DG battery voltage,DG speed etc
(ix) 2 Nos of 4 Pole MCCBs. The ratings of MCCBs should be in accordance with the KVA rating of DG set. (x) Contactors of appropriate ratings for main and DG supply of as per KVA rating should be provided (xi) Mannual By pass Change over switch in case of any mal functioning of AMF panel for continuous operation of suitable ratings as per KVA ratings (xii) Potential free contacts for extension of alarms ( 6 Nos) viz lack of fuel, LLOP, Mains failure,Engine fail to start,canopy door opening high cylinder /water temperature. (xiii) Mircoprocessor based aautomatic mains failure controller with alarms through LED/LCD for mains failure, LLOP, High cylinder temp/water temp.,over/under speed, alternator fault, DG set starts fails DG fails to stop, overload,Fuel Low, Fuel very Low, battery voltage low, DG fault, canopy door open, fire alarm.canopy temperature high, over/ under frequency etc. (xv) Battery charger (automatic) Trickle battery charger of SCR or SMPS type to charge the starting battery of DEA set.this charging shall done through main supply for which a suiable incomer shall be provided in the panel with suitable range with digital ammerter and ,voltmeter on dc side with protective fuses. Note : All componets (individual) housed in the power control should follow latest IS specifications (for MCCB, Fuse units, Fuses, HRC fuse links, CTs, CVTs, relays, Indiacting instruments.Integrating instruments,control switches and aux switches etc)
Supply, installation, testing & commissioning of factory assembled silent Diesel Engine driven generating set 1500 RPM of capacity 250 KVA, 3 phase, 4 wire, 415 volt, 0.8 PF (MSL complete with control panel including integrated powder coated accoustic enclosure as per CPCB regulations and duly certified by agencies / labs designated by CPCB for noise and sound pollution level, etc floor mounted including PCC foundation as per manufacturer's instructions complete all as specified and directed and comprising of the following :- (A) DIESEL ENGINE of required capacity for driving 250 KVA in the ambient conditions of Pathankot (Punjab) alternator multi cylinder, vertical type, 4 stroke, water cooled, electric start conforming to IS : 10001/10002/BS-5514 for continuous running capable of taking 10% overload for one hour in 12 hours complete and comprising of the following: - (i) Radiator cooling (ii) Radiator fan with guard (iii) Flywheel with starter ring (iv) Air cleaner oil bath type (v) Vacuum indicator (vi) Electronic governor class 1A (vii) Exhaust silencer (viii) Fuel filters & fuel pipelines including fuel flow meter (ix) Fuel injection pump (FIP) (x) Fan & water pump assembly (xi) Lub oil filter & Pump (xii) Oil filter (xiii) Exhaust gas driven turbo charger (xiv) Lub oil cooler (xv) Engine maintenance manual with spare parts list (xvi) Suitably designed accoustic enclosure as per CPCB regulations. (xvii) Engine safety shut down system against low lub oil pressure and high water pressure (xviii) Electric starting system with battery charging alternator and axial type starter motor including adequate number of high capacity maintenance free lead acid battery 12 volts 180 AH including interconnecting cables/ leads with terminals complete with starting/ stopping switch, volt meter etc - 01 Set. (B) ENGINE INSTRUMENT PANEL digital type indicating the following: - (i) Starting switch on/off (ii) Water temp guage (iii) Hour meter cum RPM indicator (iv) Lub oil pressure (v) Lub oil temperature (vi) Battery charging meter (vii) Safety alarm against high water temp and lub oil pressure
(C) ALTERNATOR Shall be self excited, self regulated, brushless for 250.0 KVA continuous operation at the speed of 1500 RPM at 415 volts, 50Hz , three phase four wire system with advance electric voltage regulator to ensure high voltage accuracy with ± 1% with class "H" insulation and SPDP enclosure directly coupled with engine through flexible coupling and confirming IS- 13364 complete - 1 No. (D) Common fabricated base frame for engine & alternator made from structural channel, jerk proof PCC 1:2:4 type B1 foundation including adequate number of suitable anti-vibration pads all as per the recommendation of the manufacture- 01 No (NOTE:- Cost of suitable size of PCC foundation is deemed to be included in the unit rate quoted by the contractor (E) Fuel tank fabricated out of 14 SWG MS sheet of capacity not less than 8 hrs continuous operation, inside canopy, with fuel level guage, drain plug, locking arrengements, etc with & including GI pipe connections duly laid as per engineering practice complete.
(F) AMF CONTROL PANEL Supply, fabrication,fixing commissioning and testing, factory made, floor mounted, cubical automatic mains failure panel suitable for 250 KVA DG set, fabricated using 16 guage thick CRCA sheet with hinged type with front and back side opening mounted over base frame and supported on both sides on base frame rubber pads of 6 mm- thickness shall be provided between base frame and control panel support, powder coated painting, suitable rated bus bar, internal wiring with control fuse, provn of connecting incoming & outgoing leads/bus bars as approved with and including the following accessories as under:- (i) Master switch for auto/ manual/ reset/ off - 01 No (ii) Ammeter digital type 96x96 mm to read 0 - 400 amps with CTs 1 set of 3, aux supply 230 volts, AC, accuracy class 1.0 (iii) Voltmeter digital type, 96 x 96 mm to read 0 - 500 volts aux supply 230 volts, AC, accuracy class 1.0 (iv) Digital frequency meter -01 No. aux supply 230 volts, AC. (v) Push button start, stop/ reset - 01 No (vi) Set of lamp for indicating load on , low pressure, high cylinder temperature, load on mains, set fails to start, low oil pressure etc. (vii) All functional requirements in Auto mode are to be achieved through Microproceesor based AMF controller. (viii) 4 X 20 Character back lit LCD on front fascia of showing various parameters of mains and DG viz 3 ph. Voltage , 3 ph current,frequency, KWH of mains,KWH of generated by DG,Months wise Energy register,PF of all 3 phases,DG running hours, DG battery voltage,DG speed etc
(ix) 2 Nos of 4 Pole MCCBs. The ratings of MCCBs should be in accordance with the KVA rating of DG set. (x) Contactors of appropriate ratings for main and DG supply of as per KVA rating should be provided (xi) Mannual By pass Change over switch in case of any mal functioning of AMF panel for continuous operation of suitable ratings as per KVA ratings (xii) Potential free contacts for extension of alarms ( 6 Nos) viz lack of fuel, LLOP,Mains failure,Engine fail to start,canopy door opening high cylinder /water temperature. (xiii) Mircoprocessor based aautomatic mains failure controller with alarms through LED/LCD for mains failure,LLOP,High cylinder temp/water temp.,over/under speed,alternator fault, DG set starts fails DG fails to stop, overload,Fuel Low,Fuel very Low,battery voltage low,DG fault,canopy door open, fire alarm.canopy temperature high, over/ under frequency etc. (xv) Battery charger (automatic) Trickle battery charger of SCR or SMPS type to charge the starting battery of DEA set.this charging shall done through main supply for which a suiable incomer shall be provided in the panel with suitable range with digital ammerter and ,voltmeter on dc side with protective fuses. Note : All componets (individual) housed in the power control should follow latest IS specifications (for MCCB, Fuse units,Fuses,HRC fuse links,CTs,CVTs,relays,Indicating instruments.Integrating instruments,control switches and aux switches etc).
Supply, installation, testing & commissioning of factory assembled silent Diesel Engine driven generating set 1500 RPM of capacity 750 KVA, 3 phase, 4 wire, 415 volt, 0.8 PF (MSL complete with control panel including integrated powder coated accoustic enclosure as per CPCB regulations and duly certified by agencies / labs designated by CPCB for noise and sound pollution level, etc floor mounted including PCC foundation as per manufacturer's instructions complete all as specified and directed and comprising of the following :- (A) DIESEL ENGINE required capacity for driving 750 KVA in the ambient conditions of Pathankot (Punjab) alternator multi cylinder, vertical type, 4 stroke, water cooled, electric start conforming to IS : 10001/10002/BS-5514 for continuous running capable of taking 10% overload for one hour in 12 hours complete and comprising of the following: - (i) Radiator cooling (ii) Radiator fan with guard (iii) Flywheel with starter ring (iv) Air cleaner oil bath type (v) Vacuum indicator (vi) Electronic governor class 1A (vii) Exhaust silencer (viii) Fuel filters & fuel pipelines including fuel flow meter (ix) Fuel injection pump (FIP) (x) Fan & water pump assembly (xi) Lub oil filter & Pump (xii) Oil filter (xiii) Exhaust gas driven turbo charger (xiv) Lub oil cooler (xv) Engine maintenance manual with spare parts list (xvi) Suitably designed accoustic enclosure as per CPCB regulations. (xvii) Engine safety shut down system against low lub oil pressure and high water pressure (xviii) Electric starting system with battery charging alternator and axial type starter motor including adequate number of high capacity maintenance free lead acid battery 12 volts 180 AH including interconnecting cables/ leads with terminals complete with starting/ stopping switch, volt meter etc - 01 Set. (B) ENGINE INSTRUMENT PANEL digital type indicating the following: - (i) Starting switch on/off (ii) Water temp guage (iii) Hour meter cum RPM indicator (iv) Lub oil pressure (v) Lub oil temperature (vi) Battery charging meter (vii) Safety alarm against high water temp and lub oil pressure
(C) ALTERNATOR Shall be self excited, self regulated, brushless for 750.0 KVA continuous operation at the speed of 1500 RPM at 415 volts, 50Hz, three phase four wire system with advance electric voltage regulator to ensure high voltage accuracy with ± 1% with class "H" insulation and SPDP enclosure directly coupled with engine through flexible coupling and confirming IS- 13364 complete.It shall comply with BS2613/IS 4722/IEC-34, latest Edition - 1 No. (D) Common fabricated base frame for engine & alternator made from structural channel, jerk proof PCC 1:2:4 type B1 foundation including adequate number of suitable anti-vibration pads all as per the recommendation of the manufacture- 01 No (NOTE:- Cost of suitable size of PCC foundation is deemed to be included in the unit rate quoted by the contractor (E) Fuel tank fabricated out of 14 SWG MS sheet of capacity not less than 8 hrs continuous operation, inside canopy, with fuel level guage, drain plug, locking arrengements, etc with & including GI pipe connections duly laid as per engineering practice complete. ( E ) It should be drip proof,screen protected as per IP-23 and rotor should be dynamically balanced to minimize vibrations.
(F) AMF CONTROL PANEL Supply, fabrication,fixing commissioning and testing, factory made, floor mounted, cubical automatic mains failure panel suitable for 750 KVA DG set, fabricated using 16 guage thick CRCA sheet with hinged type with front and back side opening mounted over base frame and supported on both sides on base frame rubber pads of 6 mm- thickness shall be provided between base frame and control panel support, powder coated painting, suitable rated bus bar, internal wiring with control fuse, provn of connecting incoming & outgoing leads/bus bars as approved with and including the following accessories as under:- (i) Master switch for auto/ manual/ reset/ off - 01 No (ii) Ammeter digital type 96x96 mm to read 0 - 800 amps with CTs 1 set of 3, aux supply 230 volts, AC, accuracy class 1.0 (iii) Voltmeter digital type, 96 x 96 mm to read 0 - 500 volts aux supply 230 volts, AC, accuracy class 1.0 (iv) Digital frequency meter -01 No. aux supply 230 volts, AC. (v) Push button start, stop/ reset - 01 No (vi) Set of lamp for indicating load on , low pressure, high cylinder temperature, load on mains, set fails to start, low oil pressure etc. (vii) All functional requirements in Auto mode are to be achieved through Microproceesor based AMF controller. (viii) 4 X 20 Character back lit LCD on front fascia of showing various parameters of mains and DG viz 3 ph. Voltage , 3 ph current,frequency, KWH of mains,KWH of generated by DG,Months wise Energy register,PF of all 3 phases,DG running hours, DG battery voltage,DG speed etc
(ix) 2 Nos of 4 Pole MCCBs. The ratings of MCCBs should be in accordance with the KVA rating of DG set. (x) Contactors of appropriate ratings for main and DG supply of as per KVA rating should be provided (xi) Mannual By pass Change over switch in case of any mal functioning of AMF panel for continuous operation of suitable ratings as per KVA ratings (xii) Potential free contacts for extension of alarms ( 6 Nos) viz lack of fuel, LLOP,Mains failure,Engine fail to start,canopy door opening high cylinder /water temperature. (xiii) Mircoprocessor based aautomatic mains failure controller with alarms through LED/LCD for mains failure, LLOP, High cylinder temp/water temp, over/under speed, alternator fault, DG set starts fails DG fails to stop, overload, Fuel Low, Fuel very Low, battery voltage low, DG fault, canopy door open, fire alarm.canopy temperature high, over/ under frequency etc. (xv) Battery charger (automatic) Trickle battery charger of SCR or SMPS type to charge the starting battery of DEA set.this charging shall done through main supply for which a suiable incomer shall be provided in the panel with suitable range with digital ammerter and ,voltmeter on dc side with protective fuses. Note : All componets (individual) housed in the power control should follow latest IS specifications (for MCCB, Fuse units,Fuses,HRC fuse links,CTs,CVTs,relays,Indicating instruments.Integrating instruments,control switches and aux switches etc).
Material and labour for cutting of bituminous road / floor for laying of pipe / cables not exceeding 1.5 meter wide and not exceeding 1.5 meter deep including refilling / with material and , watering well ramming / compacting and making good with PCC 1;2;4,type B-1, 100 mm thick complete all as specified and directed by Engr-in-Charge.
Supply, testing and commissioning of outdoor weather & dust vermin proof L.T. Panel board factory fabricated indoor cubicle type totally enclosed .The Panels must be design and verified as per the IS/IEC 61439-01 & 2 with complete type test certificates for conformance to IS / IEC 61439 -1 and 2, with 65 KA 1 sec along with MCCB mounted in switch boards with aluminium bus bars as mandatory as conformed to IEC 61641 with internal arc containment fault level of 65 KA/03 Sec and shall be suiatbale for Seismeic Zone III/IV Zone including the type test conducted at ERDA/CPRI for seismic test.All MCCB/ ACB panel should be single Tier for easy cable termination.Cable termination space should be adequate to safely gland and terminate al/cu cables for the given current ratings with Form B seperation for Incoming MCCB / ACB feeders and For Outgoing MCCB feeders. The Switch board cubicles shall have steel frame work enclosed on all sides and top by CRCA sheet steel of Minimum 3.15 mm thickness.The panel shall have integral base frame of 100 mm ISMC base channel.removeable undrilled gland plates shall be fitted for bottom cable entry. (FOR SITE 1 ) main LT Panel
1.Incoming:- (a) MCCB 4 Pole, 315 Amps Icu=36KA at 415 Volts microprocessor release. - 02 No (1w+ 1S) .It should be with adjustable load setting Ir = (0.8 to 1.0) x In, Ics = 100 % Icu and with adjustable load setting. Incomer MCCB 315 Amp, 4 P with microprocessor based release with adjustable O/L, Adjustable S/C setting Class II front face, Icu=36 KA at 415 Volts, Ics=100% Icu, Isolation with positive break indication with double break contacts, Standard extended rotary handle,Spreaders, Phase barrier etc 2.Outgoing:- (a) MCCB 250 Amps, Icu=36KA at 415 Volts 4P fixed type with microprocessor based release - 02 No (O/G) incl Spare - (1W +01 S). It should be with adjustable load setting Ir = (0.8 to 1.0) x In,Tcs = 100 % Icu and with adjustable thermal setting. Outgoing MCCB 250 Amp, four pole , microprocessor based release and adjustable O/L, Adjustable S/C setting Class II front face, 36 KA rupturing cap, Ics=100% Icu, Isolation with positive break indication with double break contacts, Standard extended rotary handle,Spreaders, Phase barrier etc. (b) MCCB 100 Amps, 4P, Icu=16KA at 415 Volts with thermal magnetic release - 01 No (O/G) It should be with adjustable load setting Ir = (0.8 to 1.0) x In,Tcs = 100 % Icu and with adjustable thermal setting.Outgoing MCCB 100 Amp, Four pole , should be thermal based release with adjustable O/L, Adjustable S/C setting Class II front face, 16 KA rupturing cap, Ics=100% Icu, Isolation with positive break indication with double break contacts, Standard extended rotary handle,Spreaders, Phase barrier etc
(c) MCB SPN 32 Amps 10 KA 'C' series - 01 No for Parking Light, (d) Timer switches 415 V three Phase of 20 Amp rating with all contactors and other accessories etc 3. Metering Section - Digital Ammeter (0-400) Amps, digital volt meter (0-500) Volts, RYB indicateing Lamps , 1Set Control fuses, CTs 3. 4. Bus Bar Insulated Busbar of Aluminium of 600 A capacity for 4 phases, fixed on insulators, Busbars should be PVC sleeved with red. Yellow, Blue Colour, Busbar support should be of SMC/DMC - 1 set.
BLANK
Supply, testing and commissioning of outdoor weather & dust vermin proof L.T. Panel board factory fabricated indoor cubicle type totally enclosed .The Panels must be design and verified as per the IS/IEC 61439-01 & 2 with complete type test certificates for conformance to IS / IEC 61439 -1 and 2, with 65 KA 1 sec along with MCCB mounted in switch boards with aluminium bus bars as mandatory as conformed to IEC 61641 with internal arc containment fault level of 65 KA/03 Sec and shall be suiatbale for Seismeic Zone III/IV Zone including the type test conducted at ERDA/CPRI for seismic test.All MCCB/ ACB panel should be single Tier for easy cable termination.Cable termination space should be adequate to safely gland and terminate al/cu cables for the given current ratings with Form B seperation for Incoming MCCB / ACB feeders and For Outgoing MCCB feeders. The Switch board cubicles shall have steel frame work enclosed on all sides and top by CRCA sheet steel of Minimum 3.15 mm thickness.The panel shall have integral base frame of 100 MM ISMC base channel.removeable undrilled gland plates shall be fitted for bottom cable entry. (FOR SITE 2,3 and 4) Main LT Panel.
1.Incoming:- (a) MCCB 100 Amps, 4 Pole, Icu=16KA at 415 Volts fixed type with thermal magnetic release. - 01 No .It should be with adjustable load setting Ir = (0.8 to 1.0) x In,Tcs = 100 % Icu and with adjustable thermal setting. Incomer MCCB 315 Amp, 4 P should be thermal based release with adjustable O/L, Adjustable S/C setting Class II front face, 16 KA at 415 Volts rupturing cap, Ics=100% Icu, Isolation with positive break indication with double break contacts, Standard extended rotary handle,Spreaders, Phase barrier etc 2.Outgoing:- (a) MCCB 63 Amps, 4 pole, Icu=16 KA at 415 volts fixed type with thermal magnetic release - 02 No (O/G) incl Spare - (1W +01 S). It should be with adjustable load setting Ir = (0.8 to 1.0) x In, Ics = 100 % Icu and with adjustable thermal setting. (b) MCB SPN 32 Amps 10 KA 'C' series - 01 No for POL Store and Parking . (c) Timer switches 415 V three Phase of 20 Amp rating with all contactors and other accessories etc 3. Metering Section - Digital Ammeter (0-400) Amps, digital volt meter (0-500) Volts, RYB indicateing Lamps , 1Set Control fuses, CTs 3. 4. Bus Bar Insulated Busbar of Aluminium of 160 A capacity for 4 phases, fixed on insulators, Busbars should be PVC sleeved with red. Yellow, Blue Colour, Busbar support should be of SMC/DMC - 1 set.
BLANK
Supply, testing and commissioning of indoor weather & dust vermin proof L.T. Panel board factory fabricated indoor cubicle type totally enclosed .The Panels must be design and verified as per the IS/IEC 61439-01 & 2 with complete type test certificates for conformance to IS / IEC 61439 -1 and 2, with 65 KA 1 sec along with MCCB mounted in switch boards with aluminium bus bars as mandatory as conformed to IEC 61641 with internal arc containment fault level of 65 KA/03 Sec and shall be suiatbale for Seismeic Zone III/IV Zone including the type test conducted at ERDA/CPRI for seismic test.All MCCB/ ACB panel should be single Tier for easy cable termination.Cable termination space should be adequate to safely gland and terminate al/cu cables for the given current ratings with Form B seperation for Incoming MCCB / ACB feeders and For Outgoing MCCB feeders. The Switch board cubicles shall have steel frame work enclosed on all sides and top by CRCA sheet steel of Minimum 3.15 mm thickness.The panel shall have integral base frame of 100 MM ISMC base channel.removeable undrilled gland plates shall be fitted for bottom cable entry. (FOR SITE 5) Main LT Panel.
1.Incoming:- (a) Incoming ACB 4 pole, 415 Volts microprocessor based (Electrically Draw out type) of capacty 1000 Amps, 50KA - 02 Nos (Incoming from Transformer) Siemens-ETU series 45 or Equivalent 2.Outgoing:- (a)Outgoing ACB 4 pole, 415 Volts microprocessor based (Electrically Draw out type) of capacty 800 Amps, 50KA - 02 Nos . Siemens-ETU series 45 or Equivalent (b) Outgoing MCCB 400 Amp, Icu = 36 36 KA at 415 volts , 4P should adjustable type with microprocessor based release - 02 No (O/G) incl Spare - (1W +01 S). It should be with adjustable load setting Ir = (0.8 to 1.0) x In, Ics = 100 % Icu and with adjustable load setting. (c) MCB SPN 32 Amps 10 KA 'C' Series - 01 No for Parking . (d) Timer switches 415 V three Phase of 20 Amp rating with all contactors and other accessories etc 3. Metering Section - Digital Ammeter (0-1200) Amps, digital volt meter (0-500) Volts, RYB indicateing Lamps , 1Set Control fuses, CTs 3. 4. Bus Bar Insulated Busbar of Aluminium of 1500 A capacity for 4 phases, fixed on insulators, Busbars should be PVC sleeved with red. Yellow, Blue Colour, Busbar support should be of SMC/DMC - 1 set. All ACB Should Have the Following Specifications : (a) Specifications: 4 pole,1000A, 415 Volts, 50KA (rms) 1sec, 50Hz supply timer (b) Mounting : draw out mounting with safety shutters (c) Type of operation : Electrical by 230 Volts AC motor with manual handle (d) Closing coil voltage :230 Volts AC (e) Tripping Coil Voltage : 230 Volts AC (f) UV Voltage : 230 Volts AC Relay Type : Microprocessor based with Earth leakage, over current,short circuit protections for generator application (In 2 generator feeders) others ACB's with industrial applications (h) Aux Contracts : Min 3 No+ 3 NC, 1 NO + 1NC Extended up to panel terminal blocks for remote PLC Interlock (I) Display : with display (j) Type of protection :IP 54
BLANK
BLANK
Supply, testing and commissioning of outdoor weather & dust vermin proof L.T. Panel board factory fabricated indoor cubicle type totally enclosed .The Panels must be design and verified as per the IS/IEC 61439-01 & 2 with complete type test certificates for conformance to IS / IEC 61439 -1 and 2, with 65 KA 1 sec along with MCCB mounted in switch boards with aluminium bus bars as mandatory as conformed to IEC 61641 with internal arc containment fault level of 65 KA/03 Sec and shall be suiatbale for Seismeic Zone III/IV Zone including the type test conducted at ERDA/CPRI for seismic test.All MCCB/ ACB panel should be single Tier for easy cable termination.Cable termination space should be adequate to safely gland and terminate al/cu cables for the given current ratings with Form B seperation for Incoming MCCB / ACB feeders and For Outgoing MCCB feeders. The Switch board cubicles shall have steel frame work enclosed on all sides and top by CRCA sheet steel of Minimum 3.15 mm thickness.The panel shall have integral base frame of 100 MM ISMC base channel.removeable undrilled gland plates shall be fitted for bottom cable entry. (FOR SITE 5 ) Second LT Panel
1. Incoming:- (a) MCCB 630 Amps Icu=50 KA at 415 Volts Four pole adjustable type with microprocessor based release. – 01 No .It should be with adjustable load setting Ir = (0.8 to 1.0) x In,Ics = 100 % Icu and with adjustable icroprocessor setting. Isolation with positive break indication with double break contacts, Standard extended rotary handle,Spreaders, Phase barrier etc” 2. Outgoing:- (a) MCCB 400 Amps Icu=36 KA at 415 Volts Four pole adjustable type with microprocessor based release. – 02 No.(1W+1spare) .It should be with adjustable load setting Ir = (0.8 to 1.0) x In,Ics = 100 % Icu and with adjustable icroprocessor setting. Isolation with positive break indication with double break contacts, Standard extended rotary handle,Spreaders, Phase barrier etc (b) MCCB 63 Amps Icu=16 KA at 415 Volts Four pole adjustable type with thermal magnetic release. – 01 No.It should be with adjustable load setting Ir = (0.8 to 1.0) x In,Ics = 100 % Icu and with adjustable thermal setting. (c) MCB SPN 32 Amps 10 KA, 'C' series - 03 No for Guard Post, Guard Room and Parking . (d) Timer switches 415 Volts three Phase of 20 Amp rating with all contactors and other accessories etc
3. Metering Section - Digital Ammeter (0-400) Amps, digital volt meter (0-500) Volts, RYB indicateing Lamps , 1Set Control fuses, CTs 3. 4. Bus Bar Insulated Busbar of Aluminium of 600 A capacity for 4 phases, fixed on insulators, Busbars should be PVC sleeved with red. Yellow, Blue Colour, Busbar support should be of SMC/DMC - 1 set.
BLANK
Supply and fixing of cable route indicator at the distance of 50 mtrs each made out of 45 x 45 x 5 mm angle iron, 80 mm long embedded in PCC block of suitable size with moulded lettter HT CABLE or LT CABLE suitably incribed on CI circular plate 8 mm thick 100 dia including painting with two coats of synthetic enamelled paint over a coat of red oxide primer incl neccessary PCC 1:3:6, type C-2 (using 40 mm graded aggrregate) block of suitable size and neccessary earth work and excavation all as specified and directed.
Supply and fixing of Blanking plates in vacant modules of distribution boards (DBs) all as specified and directed.
Total amount of Sch 'A' PART-XII (SEC-II) (EXTERNAL ELECTRICAL SUPPLY WORK)
Total amount of Sch 'A' Part-XIII (RCC RETAINING WALL WORKS)
Total amount of Sch 'A' PART-XIV (Section-I) (FLAME PROOF LIGHTING WORKS)
Sch 'A' PART-XIV (Section-II) (FLAME PROOF LIGHTING WORKS) Note: This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
M & L Point wiring with 1.5 sqmm single core, PVC insulated with multistranded PVC unsheathed copper conductor cable HRFR drawn in stove enamel steel conduit concealed not less than 20mm dia medium grade ISI marked and sunken pressed steel terminal switch boxes to accommodate swicthes/ sockets flush mounting type with including earth wire continuity of PVC insulated, unsheathed 1.5 sqmm HRFR copper conductor connected to all fittings, sunken boxes and common earth and connected to common earth dolly shall be fix with copper lugs complete all as specified and directed for the following:- (a) One light controlled by one , one way switch 5 amps complete all as specified and directed.
Supply and fixing of flame proof heavy duty exhaust fan 300 mm sweep 1120 RPM with louvers and shutters 240Volts single phase AC supply with in aluminium die cast alloy LM6 construction of Gas Gr-IIA, IIB certified by CIMFR Dhanbad & CCOE (Pers) Nagpur with all fixing arrangements to fix to wall including making hole 3 way porcelain connector,copper bunched flexible 3 core 1.5 sqmm PVC insulated copper cable from connected to exhaust fan complete including making good the distrubed surface complete all as specified and directed by Engr-in-Charge.
Supply and fixing of flame proof MCB DB SPN 4way with 200Amps rated bus bar, 230Volts, double door including RCBO, 2 Pole, with 100mA sensitivity, of rating 40Amps 'C' series (incomer) external protection metal clad suitable box with locking arrangements confirming to IP-66 with all necessary wiring connections and making good the distrubed surfaces to match with the existing complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing of flame proof switch rotary type in aluminium die cast alloy LM6 construction of gas Gr IIC certified by CIMFR Dhanbad & CCOE Nagpur ISI marked SP 10 Amps capacity with cable termination box complete all as specified and directed by the Engineer-in-Charge.
Sub Total amount of Sch 'A' PART-XIV (Section-II) (FLAME PROOF LIGHTING WORKS)
Total amount of Sch 'A' PART-XV (Section-I) (DIFFIRENT TYPE OF EARTHING/CHEMICAL EARTHING WORKS)
Sch 'A' PART-XV (Section-II) (DIFFERENT TYPE OF EARTHING/CHEMICAL EARTHING WORKS) Note: This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
Supply and fixing of copper strip 50 x 6 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed by Engr-in-Charge.
Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6.0mm thick buried directly in ground, (Earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connected to and including 4 mm dia galvanized earth lead wire by means of bolts, nuts, check nuts and washers of galvanized standard iron or steel all as specified or indicated in electrical plate No 3 of MES Part-I, including testing on completion including the material and labour of the following: - (a) Excavation and earth work or drilling hole for electrode in any type of soil. (b) PCC pit in cement concrete 1:2:4 type B-1. (c) Precast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 1.87 Kg/Sqm. (d) Funnel with watering pipe of GI 20 mm nominal bore medium grade and copper lugs etc all as specified. (e) 15 mm nominal bore light grade GI protection pipe 5 mtr long for protection of earthing lead from mechanical injury or tempering. (f) Requisite quantity of common salt and charcoal. (g) Testing of earthing. Note: (1) The earth resistance shall be less than 5 ohms after completion of earthing. If the desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk and cost to the entire satisfaction of the Engineer-in-Charge.
Earthing complete with copper earth plate electrode 60 cm x 60 cm x 3.15 mm thick buried directly in ground, (Earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connected to and including 20 x 3 mm copper earth strip by means of bolts, nuts, check nuts and washers of galvanized standard iron or steel all as specified or indicated in electrical plate No 3 of MES Part-I, including testing on completion including the material and labour of the following: - (a) Excavation and earth work or drilling hole for electrode in any type of soil. (b) PCC pit in cement concrete 1:2:4 type B-1. (c) Precast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 1.87 Kg/Sqm. (d) Funnel with watering pipe of GI 20 mm nominal bore medium grade and copper lugs etc all as specified. (e) 40 mm nominal bore light grade GI protection pipe 5 mtr long for protection of earthing lead from mechanical injury or tempering. (f) Requisite quantity of common salt and charcoal. (g) Testing of earthing Note:- (1) On testing after completion of earthing, if the desired earth resistance is less than 5 ohms , the earthing will be re-done by the contractor at his own risk and cost to the entire satisfaction of the Engineer-in-Charge
Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6.0mm thick buried directly in ground, (Earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connected to and including 32 x 6mm GI strip as earth lead burried into ground and connected by means of bolts, nuts, check nuts and washers of galvanized standard iron or steel all as specified or indicated in electrical plate No 3 of MES Part-I, including testing on completion including the material and labour of the following: - (a) Excavation and earth work or drilling hole for electrode in any type of soil. (b) PCC pit in cement concrete 1:2:4 type B-1. (c) Precast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 1.87 Kg/Sqm. (d) Funnel with watering pipe of GI 20 mm nominal bore medium grade and copper lugs etc all as specified. (e) 40 mm nominal bore light grade GI protection pipe 5 mtr long for protection of earthing lead from mechanical injury or tempering. (f) Requisite quantity of common salt and charcoal. (g) Testing of earthing. Note: (1) The earth resistance shall be less than 5 ohms after completion of earthing. If the desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk and cost to the entire satisfaction of the Engineer-in-Charge.
Supply and fixing Chemical earthing complete with copper earthing plate electrode of size 900x600x5mm thick buried directly into ground vertically to the depth not less than 5.0 metre below normal ground level with top edge of earth plate not less than 4.0 metre below normal ground level, surrounding on the all side by charcoal, common salt and magnisium sulphate (or any chemical recommended by manufacturer for increasing earth conductivity) starting from the ground below earth plate in alternate layers including replacement of excavated soil with artificially treated soil (soil having low resistivity) connected to copper strip of size 50 x 6 mm earth lead by means of copper lugs, nut, bolts and washers, earthing strip protected by 80mm bore light grade GI pipe in floor and fixed with wall with proper size of Fe clamps and watering pipe 15 mmm bore GI light grade including wire mess, funnel PCC earth chamber pit with 1:2:4 type b-1 (using 20 mm graded crushed stone aggregate) including form work cement mortar with height 300mm above normal pit, excavation and earth work in any type of soil including testing on completion for desired result of 1 Ω all as shown and specified in plate No 3 of SSR part-I 2009 complete all as specified and directed by Engineer-in-Charge. The unit rate includes GI pipe up to 7.5m for protection of earth lead. (ii) The unit rate includes main earthing lead/strip from earth electrode to test point up to 7.5 meter (iii) If there is a requirement of Grid Earthings to achieve desired earth resistance, as directed by Eng-in-charge, then inter connecting of different earthings shall be done at no extra cost
Sub Total amount of Sch 'A' PART-XV (Section-II) (CHEMICAL EARTHING WORKS)
Total amount of Sch 'A' PART-XVI (LAN CONDUITS WORKS)
Total amount of Sch 'A' PART-XVII (17 FIRE POINT WORKS)
Total amount of Sch 'A' PART-XVIII (INCINERATOR WORKS)
Total amount of Sch 'A' PART-XIX (Section-I) (SITE CLEARANCE WORKS)
Sch 'A' PART-XIX (Section-II) (SITE CLEARANCE WORKS) Note: This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
Cutting of bushes, shrubs of n. exc. 15 cm girth including taking out roots of shrubs/bushes from ground and density of bushes/shrubs will vary from 8 to 12 nos. per sqm area including making the ground levelled and removal of shrubs, bushes and grass outside from Technical area and deposited complete all as specified and directed by Engineer-in-Charge
M&L for bringing extra earth i.e granular material if required from outside ministry of defence (MOD) land at a distance exc 1.50 Km and not exc 6.00 Km for filling and raising (or lowering) earth, spreading in layer not exc 25 cm thick, watering, compacting and finishing to required gradient/ shape and deposited where complete all as specified and directed by Engineer-in-Charge
Uprooting Vegetation and weeds by ploughing and removing the other growth with roots sorting the stone including disposal.The depth must be between 20 cm extra earth filling 6 cm for grassing levelling the area and to prepare the bed to the entire satisfaction of Engr-In-Charge complete all as specified and directed by Engineer-in-Charge
Sub Total amount of Sch 'A' PART-XIX (Section-II) (SITE CLEARANCE WORKS)
Total amount of Sch 'A' Part-XX (DEMOLITION WORK)
NOTE: Amount against schedule of credit for retrieved materials mentioned under relevant part of Sch of Credit of tender document in PDF form will be deducted offline/manually from overall amount quoted by the lowest bonafide bidder during award of contract.
Onkar Nath Bhalla And Sons Contractor Pvt. Ltd.
A S CONSTRUCTION COMPANY
ENGINEER CONSTRUCTION PVT. LTD.
SAGGI ELECTRIC COMPANY
Shekhar Enterprises
NAFREF ENGINEERS PVT LTD
Chandra Construction
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid