Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.9 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹21.5 L+₹1.6 L (7.91%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹22.0 L+₹2.0 L (10.3%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹23.0 L+₹3.1 L (15.4%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | L5₹23.0 L+₹3.1 L (15.4%)Rejected-AOC | L5 | Rejected-AOC L5 |
Tender Value
₹21 L
EMD Value
₹42,000
Closing Date
29 Dec 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri Kislay Kishore, IDSE
GE (AFA) Hyderabad PIN-600043
PROVISION OF 30KVA UPS FOR SD SIMULATOR AT 2AMTC AND CERTAIN MINOR/ REVENUE WORKS AT AFA HYDERABAD
2022_MES_565333_1
8301/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AFA) Hyderabad
As per documents
4 documents required · 4 mandatory
₹500
GE (AFA) Hyderabad
₹42,000
Yes
16 Mar 2023
25 Nov 2022
31 Dec 2022
25 Nov 2022
29 Dec 2022
9 Dec 2022
25 Nov 2022 - 8 Dec 2022
Amount
Supply, installation, testing & commissioning of UPS with three phase AC input 300 to 400 volts and output three phase 415 volts +/- 1% of capacity 30KVA power factor (> 0.99) and sealed maintenance free battery bank for 30Min back up complete all as specified and directed including following equipments:-
(a) Battery Rack -1 No
(b) Battery inter connecting links -1 No
(c) Battery to UPS cable - 1No
(d) Battery Fuses
(e)Battery rating 12 V/ 65 AH - 32 Nos
(f) The following feature to be provided :- (i) Unity output power Factor (ii) DSP Technology with IGBT based PFC and inverter section (iii) Smart LCD Display for Real-time information (iv) Active power Factor correction in all phase (v) 50Hz/60Hz Frequency converter mode (vi) ECO mode operation for energy saving (ECO) (vii)Emergency power off function (EPO) (viii) EMI protection Available(C3- Level) (ix) 3-Level IGBT inverter topology design maximizes efficiency (x) SNMP + USB+ RS-232 multiple communication available (xi) 3-stage extendable charging design for optimized battery performance (xii) Surge protection Available at Input (xiii) Adjustable Battery number for long-run model (xiv) Built-in Maintenance Bypass and static Bypass Switch (xv) Generator compatible
M&L for Earthing complete with copper earth plate of size 900 x 600 x5mm & copper earth strip 32x6mm burried directiy in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layer and electrode connection by using copper strip of size 32X6mm connected by means of bolts, nuts, check nuts and washer of galvanised iron or steel, provision of 40 mm dia GI pipe medium grade for protection of copper earth strip and 20mm dia GI pipe medium grade for watering arrangement and PCC (1:3:6) type C1 chamber, MS funnel, wire mesh 50mm thick RCC 1:2:4 type B1 earth pit cover with 6 Nos,8 mm dia high strength deformed steel TMT bars on both ways including necessary excavation in any type of soil returning, filling in, removal of surplus soil to distance n exc 50 mtr, provision of charcoal and salt complete all as shown in electrical plate No3 of schedule Part-I. Note: Earthing lead and GI protection pipe beyond 7.5m will be measured and paid separately. 3) All the joints should be brazed only brass nuts/ bolts/ washers can be used in the test point complete all as specified and as directed
S&F of Copper strip 20 x 3mm fixing on wall with saddles and screws etc.connected to test point complete all as directed.
S & F wiring for circuit/submain wiring alongwith 4 x 10 sq. mm +2 x10 sq. mm as earth wire of FRLS PVC insulated copper conductor, single core cable drawn through and including surface/recessed in stove enamelled Steel Conduit of suitable size but not less than 40mm dia including all accessories and necessary work for fixing like welding screws, clamps etc. on iron chanel/angle/wall surface etc all as specified and as directed. Note : (i) 6 runs of copper wire 10 Sqmm and one run of steel conduit will be measured as one length
(ii) Necessary MS dummy plates & junction boxes for identifying junction as required on site/directed by Engr-in-charge shall deem to be included in the quoted rate.
(iii) Same size wire shall be used for phase, neutral & earth conductor
(iv) The wiring shall be done strictly by following proper colour coding using red, yellow and blue only for phase, black for neutral and green for earth leads.
S & Fof test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including3 nos. 8mm dia 25 mm long hex. head screw complete all as specified and directed.
Excavation in trenches in any type of soil n.exc 1.5 m wide and n. exc 1.5 m depth and getting out, including trimming the sides and forming bottom surface to required levels for laying cables, pipe lines etc complete all as specified and as directed.
M&L River dry sand cushioning to UG cables (8 cm deep before laying of cable and 15 cm deep over the cable) in trenches including punned to thickness up to 18 cm and consolidation, complete all as directed. Note :- Punned thickness only will be considered for payment.
Returning, filling in trenches in any type soil in layers n.exc. 25 cm after laying of cables including spreading, levelling, and well ramming complete all as specified and directed.
Supply & lay common burnt, clay building bricks, sub class 'B' designation over the sand cushioning in cable trenches for protection of cables (LT) complete all as specified and as directed
Removing surplus excavated material (soil) to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed
Supply, laying & testing insulated XLPE UG cable 1100 volts grade, armoured confirming to relevant IS specifcations with aluminum conductor of size 95 sqmm 3.5 core including dismantling and taking out the unserviceable cable all as directed.
Supply, laying & testing insulated XLPE UG cable 1100 volts grade, armoured confirming to relevant IS specifcations with aluminum conductor of size 16 sqmm 4 core including dismantling and taking out the unserviceable cable all as directed.
M&L for light grade galvanized pipe ISI marked with all fitting ISI marked, laid in trenches, under road or fixing on wall/pole/ crossing nallah etc of bore 100 mm complete all as specified and as directed .
S &F MCCB adjustable thermal & fixed magnetic release 4 pole 50 kA 400 A including dismantling and taking out the existing unserviceable MCCB , connecting up complete all as directed at site.
S&F cable route marker made up of PCC block (1:3:6) type. C-1 using 20mm graded stone aggregates of size 900 mm x 300mm x 100 mm thick (45 Cm buried in ground) and properly painted colour as per approved by Enginer - in -charge (LT) and written both side with signed red colour paint (MES LT cable 11 KV ) on route marker/Indicator including necessary excavation, PCC and earth work complete all as specified and as directed.
Boring of holes under road, pavement hard standing by using trenchless technology using ultrasound technique and necessary machine to insert pipe of 50 to 100mm light grade GI pipes as per site requirement with all fittings such as bends, elbows, Tees, etc, for protection of cable complete including all plant & machinaries, T&P etc required all as specified and as directed. Note :- Protection pipe will be measured and paid separately
M&L for shifting of change over switch complete including taking down from existing location and fixing at new locations with all fixing arrangements like lugs, nut, bolt, shifting of cable/wire and making connections all as specified and as directed by Engr-in-Charge.
M&L for shifting of existing AMF panel of 20 to 30 KVA DG set complete including taking down from existing location and fixing at new locations with all fixing arrangements like lugs, nut, bolt, shifting of cable/wire and making connections all as specified and as directed by Engr-in-Charge.
M&L for shifting of Electric meter complete including taking down from existing location and fixing at new locations with all fixing arrangements like lugs, nut, bolt, shifting of cable/wire and making connections all as specified and as directed by Engr-in-Charge.
M&L for shifting of MCB DBs of any size TPN complete including taking down from existing location and fixing at new locations with all fixing arrangements like lugs, nut, bolt, shifting of cable/wire and making connections all as specified and as directed by Engr-in-Charge.
M&L for shifting of MCB DBs of any size SPN complete including taking down from existing location and fixing at new locations with all fixing arrangements like lugs, nut, bolt, shifting of cable/wire and making connections all as specified and as directed by Engr-in-Charge.
M&L for shifting of voltage stabilizer upto 5 KVA capacity single phase complete including taking down from existing location and fixing at new locations with all fixing arrangements like lugs, nut, bolt, shifting of cable/wire and making connections all as specified and as directed by Engr-in-Charge.
M&L for shifting of UPS system with battery bank upto 10 KVA capacity three phase complete including disconnecting from existing location and shifting and fixing at new locations with all fixing arrangements like lugs, nut, bolt, shifting of cable/wire and making connections all as specified and as directed by Engr-in-Charge.
S&F of 3 Way connector strip of cap 60 Amp made of polyetheylene including wooden/FRP board of suitable size as required at site and all acessories for fixing on wall and making connectons with suitable size lugs all as specified and directed by Engineer-in-Charge.
M&L for Sub Main wiring with 4x16 Sqmm 1100 V grade (nominal area) single core PVC insulated unsheathed cable multi-stranded copper conductor drawn through and including medium grade, rigid non-metallic PVC conduit of size 25mm or higher suitable size with all necessary fittings, concealed in walls/roof/floor duly earthed with 2x16 Sqmm of single core cable but green in colour as continuous earthing wire and connecting to common earth dully complete including taking down old submain wiring all as specified and directed by Engineer-in-Charge. Note : (i) 6 runs of 16 sqmm copper wire and one run of PVC conduit will be measured as one length
(ii) Necessary PVC dummy plates & PVC rigid junction boxes for identifying junction as required on site/directed by Engr-in-charge shall deemed to be included in the quoted rate.
(iii) Same size wire shall be used for phase, neutral & earth conductor
(iv) The wiring shall be done strictly by following proper colour coding using red, yellow and blue only for phase, black for neutral and green for earth leads.
M&L for Sub Main wiring with 2x6 Sqmm 1100 V grade (nominal area) single core PVC insulated unsheathed cable multi-stranded copper conductor drawn through and including medium grade, rigid non-metallic PVC conduit of size 25mm or higher suitable size with all necessary fittings, concealed in walls/roof/floor duly earthed with 1X6 Sqmm of single core cable but green in colour as continuous earthing wire and connecting to common earth dully complete including taking down old submain wiring all as specified and directed by Engineer-in-Charge. Note :(i)3 runs of 6 sqmm copper wire and one run of PVC conduit will be measured as one length
(ii) Necessary PVC dummy plates & PVC rigid junction boxes for identifying junction as required on site/directed by Engr-in-charge shall deemed to be included in the quoted rate.
(iii) Same size wire shall be used for phase, neutral & earth conductor
(iv) The wiring shall be done strictly by following proper colour coding using red, yellow and blue only for phase, black for neutral and green for earth leads.
M&L for Sub Main wiring with 2x4 Sqmm 1100 V grade (nominal area) single core PVC insulated unsheathed cable multi-stranded copper conductor drawn through and including medium grade, rigid non-metallic PVC conduit of size 25mm or higher suitable size with all necessary fittings, concealed in walls/roof/floor duly earthed with 1X4 Sqmm of single core cable but green in colour as continuous earthing wire and connecting to common earth dully complete including taking down old submain wiring all as specified and directed by Engineer-in-Charge. Note : (i) 3 runs of 4sqmm copper wire and one run of PVC conduit will be measured as one length
Note :- (ii) Necessary PVC dummy plates & PVC rigid junction boxes for identifying junction as required on site/directed by Engr-in-charge shall deemed to be included in the quoted rate.
(iii) Same size wire shall be used for phase, neutral & earth conductor
(iv) The wiring shall be done strictly by following proper colour coding using red, yellow and blue only for phase, black for neutral and green for earth leads.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25.0 sq mm 4 core, Complete all as specified and directed
S&F of MCCB DB 4 way triple pole vertical type 415 volts 50 Hz AC supply including suitable provision for 4 pole MCCB incomer, fixed to the existing wall (concealed) and making good the disturbed surface wall with the exsting wall complete all as specified and as directed. Note : MCCB/MCB will be measured seperately
S&F MCCB 4 pole 63 Amps, 16KA breaking capacity, 415Volts 3-phase supply complete all as specified and directed.
S&F MCB SPN 6 to 32A, 10KA rupturing capacity complete all as specified and as directed.
Design, supply, erection, testing and commissioning of outdoor type LT feeder pillar box platform mounted (to be mounted on the P.C.C. brick pedestal), suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bars of rating not less then 100 amps, Spreader link to incoming/outgoing MCCB for termination of incoming/outgoing cable and Aluminium connecting bars of suitable size (R-Y-B-N) for outgoing cables, duly fabricated in a CPRI approved / certified factory having modern fabrication and testing facility which includes at least seven (07) tanks pre treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron)with approved shade of RAL 7032. The feeder pillar shall be provided with suitable Neoprene rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 3.00mm thick CRCA mild steel sheet and 3.00mm thick gland plate and having front opening facility (with double layer shutter) and rear opening facility with single layer shutter with locking facility and 2 side slanting canopy type roof on top and mild steel angle (50x50x5mm) legs of length 30 cm at bottom, suitable for mounting on the pedestal, The feeder pillar shall be provided with ventilation facility in the form of louvers for better heat dissipation, including taking down old unserviceable.
M&L for Earthing complete with GI earth plate electrode 600x600x6mm thick buried directly in ground vertically to a depth of not less than 2.25m below ground level with the top edge of earth plate at a depth of not less than 1.5m below ground level connected to GI earth strip of size 32 x 6 mm as earth lead by means of brazing etc all as shown in electrical plate No 3 connected to earthing test point as specified or indicated including testing on completion. Note:- (1) The unit rate shall also include for earth work in any type of soil, PCC (1:3:6) type C1 chamber, pre-cast RCC (1:2:4) type B-1 using 20mm graded stone aggregate cover 50mm thick reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg/sqm, funnel with watering pipe 20mm dia medium grade, GI protection pipe light grade 40mm dia and wire mesh complete in addition to item No. 1(a) to (e) of preamble (notes) under sub-heading earthing, specified on Sl. Page Nos. 422 & 423 of SSR Part-II. 2) Earthing lead and GI protection pipe beyond 7.5m will be measured and paid separately. 3) All the joints should be brazed only brass nuts/ bolts/ washers can be used in the test point complete all as specified and as directed
M&L for Sub Main wiring with two runs of 4.0sq.mm. (nominal area) single core PVC insulated unsheathed FRLS cable multi-stranded copper conductor 1100 Volts drawn through and including stove enamelled PVC conduit of suitable size but not less than 20mm dia, with all fittings, surface on wall / ceiling / roof duly fixed with fixing clamps including MS box of thickness not less than 1.2mm, for fixing of switches and duly earthed with 01 run of 4sq.mm. (nominal area) single core PVC insulated unsheathed FRLS cable multi-stranded copper conductor cable green in colour as continuous earthing wire complete all as specified and as directed Note : (i) 3 runs of 4sqmm copper wire and one run of steel conduit will be measured as one length
(ii) Necessary PVC dummy plates & PVC rigid junction boxes for identifying junction as required on site/directed by Engr-in-charge shall deemed to be included in the quoted rate.
(iii) Same size wire shall be used for phase, neutral & earth conductor
(iv) The wiring shall be done strictly by following proper colour coding using red, yellow and blue only for phase, black for neutral and green for earth leads.
S&F GI pipes "light grade" complete including all fittings of size 100 mm dia ISI marked laid in floors / trenches etc complete for cable protection all as specified and as directed
S&F Gun metal gate valve 50 mm dia bore with iron wheel head screwed both ends for iron pipes and complete all as directed.
S&F Gun metal gate valve 40 mm dia bore with iron wheel head screwed both ends for iron pipes complete all as directed.
&F Gun metal gate valve 25 mm dia bore with iron wheel head screwed both ends for iron pipes complete all as directed.
S&F Gun metal non return valve ISI marked with flanged and connecting to GI pipe of size 50 mm bore including jointing materials, nuts bolts, washers and necessary accessories etc complete all as specified and as directed.
S&F Gun metal Foot valve of size 50 mm bore including jointing materials, nuts bolts, washers and necessary accessories etc complete all as specified and as directed.
Supply, Laying, jointing and testing GI pipe of 50 mm medium grade laid in trenches/wall/floors/roofs etc in any length with screwed and socket joints together with and including with all galvanised steel fittings such as sockets, elbows, bends, tees, reduces, short pieces, unions, caps, plugs etc all as specified and directed.
Supply, Laying, jointing and testing GI pipe of 40 mm medium grade laid in trenches/wall/floors/roofs etc in any length with screwed and socket joints together with and including with all galvanised steel fittings such as sockets, elbows, bends, tees, reduces, short pieces, unions, caps, plugs etc all as specified and directed.
Supply, Laying, jointing and testing GI pipe of 25 mm medium grade laid in trenches/wall/floors/roofs etc in any length with screwed and socket joints together with and including with all galvanised steel fittings such as sockets, elbows, bends, tees, reduces, short pieces, unions, caps, plugs etc all as specified and directed.
Supply,install,testing and commissioning of Monoblock booster pump sets of Capacity 2 HP minimum head of 30 mtrs. suitable for electric driven 240 V, 50HZ, single Phase complete and angular frame foundation with nut,bolt grouting suitable for pump set all as specified and as directed..
S&Fof Galvanized iron sheet canopy fabricated with 1mm thick sheet suitable for Monoblock pumpset complete all as specified and as directed
Supply, fix, connect and test DOL starter with sheet steel enclosures, single phase, 240 volts, 50 Hz suitable for 2 HP motor complete all as specified and as directed
S&F for Submersible cable, PVC insulated, PVC sheathed 1100 volts grade, multistranded copper conductor flat, 3 core 4 Sqmm complete all as specified and as directed.
M&L for cutting of existing GI pipe line of 50mm dia for alterations and additions including provision of reducer Tee screwed to GI pipe and providing GI fittings of suitable size as required at site of work including necessary excavation and earth work complete all as directed
S&F of Rotational moulded polyethylene double layered water storage tank of capacity 3000 ltrs (cylindrical vertical with screwed type closed top) hoisted and fixed on suitable PCC foundation all as specified and directed. Note: PCC foundation measured seperately
M&L for PCC 1:3:6, type C1 (using 20 mm graded stone aggregate) as in coping, bed plates, etc., including weathering, slightly rounded or chamfered angles and throating, necessary form work for pump set foundation , water tank etc. complete all as specified and as directed.
M&L point wiring (surface type) for(Light/Fan/bell) using 1.5 sqmm nominal cross sectional area copper conductor mutimultistranded ,PVC insulated unsheathed , FRLS cables in and including PVC casing and caping and fittings, including 1.2mm thick pressed steel terminal switch boxes , 3 mm thick bakelite sheet top cover (ISI Marked) fitted with Chromium plated brass screws & washers and 1.5 sqmm nominal cross sectioanl area multi-multistranded copper conductor , FRLS, green PVC insulated unsheathed earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed of the following:.
(a) One light point controlled by one switch
(b) One Exhaust fan point controlled by one switch
(c) One three pin socket 5 Amps independent
(d) One three pin socket 5 Amps plug point on same board
All as per item No 73 above but wiring 2.5 sqmm copper cable with 2.5 sqmm for earth continuity cable for 6 pin 15 Amp socket outlet controlled by 15 Amp switch
S&F Socket outlet polycorbonate white 6A - 2/3 pin complete all as specified and as directed.
S&F Switch socket combination polycorbonate white 2 in 1, 3 pin, 5 Amp flush type universal complete all as specified and as directed.
S&F Switch socket combination polycorbonate white 2 in 1, 3 pin, 15 Amp flush type universal complete all as specified and as directed.
S&F Switch Piano type polycorbonate white 1 way, 6A, 240Volts complete all as specified and as directed.
S&F of ceiling rose, three terminal, PVC/polycarbonate, insulated body, ISI marked complete all as specified and as directed.
S&F LED light fitting 1x20 W 220 V AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
S&F MCCB DB double door 4 way triple pole vertical type 415 volts 50 Hz AC supply including suitable provision for 4 pole MCCB incomer, fixed to the existing wall (concealed/surface) and making good the disturbed surface wall with the exsting wall complete all as specified and as directed. Note : MCCB/MCB will be measured seperately.
S&F of MCB SP 6 to 32 A 10 KA rupturing capacity complete all as specified and as directed.
M&L for Earthing complete with GI earth plate electrode of size 600x600x6 mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to GI wire 4 mm dia earth lead by means of nuts, bolts, check nuts, washers of galvanised iron as steel, protected by galvanized iron pipe 25mm bore (Light grade) all as directed including cement concrete (1:3:6) type C-1 earth pit with precast RCC (1:1.5:3) type A-1 cover slab of size 42 x 42 x10cm thick reinforced with 8mm dia TMT bars @ 15 cm c/c both ways with 10mm dia mild steel round bar of 30 cm long, bent to shape as lifting handle, funnel, wire mesh, 20 mm bore galvanized iron pipe (medium grade) for watering, earth testing point, charcoal or coke and salt in alternate layers with necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part I including testing on completion all complete as specified and directed . Note:(i) Earthing lead and GI protection pipe beyond 7.5m will be measured and paid separately. (ii) All the joints should be brazed only with brass nuts/ bolts/ washers can be used in the test point complete all as specified and as directed
S&F exhaust fan iron body with louvers 300 mm sweep single phase 240V AC 50 Hz and connecting up including louvers including making necessary opening on stone/brick masonary wall of suitable size, finishing it properly and making good with matching colours with the surrounding and provision of copper cable 3 core of size 0.5 Sqmm from ceiling rose to fan complete all as specified and directed.
S & F DB with sheet metal enclosure 240 volts, 6 way Single phase double door with copper bus bar neutral link, earth link, earthing studs, without MCBs completeall as directed. Note: Distribution Board shall be fitted out side of the explosive store complete all as directed.
S&F of exhaust fan made of sturdy engineering plastic complete with louvers 300 mm sweep single phase 230V AC 50 Hz, RPM 1200 and including making necessary opening on stone/brick masonary wall of suitable size finishing it properly and making good with matching colours with the surrounding and provision of copper cable 3 core of size 0.5 Sqmm from ceiling rose to fan complete all as specified and directed.
POWER CONSTRUCTION COMPANY
Indu Electricals
S J REDDY
M/s Amit Associates
AKSHITA ELECTRICAL
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .