| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.3 LAccepted-AOC | L1 | Accepted-AOC lowest | |
| 2 | L2₹12.3 L+₹98,396 (8.68%)Rejected-Finance 7TH MILE UPPER SHILLONG P O NONGLYER SHILLONG MEGHALAYA | EAST KHASI HILLS | MEGHALAYA | 793009 | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹12.7 L+₹1.4 L (12.2%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹13.5 L
EMD Value
₹26,980
Closing Date
1 Mar 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) AIR FORCE STATION AMRITSAR
ASST. GARRISON ENGINEER (I) AIR FORCE STATION AMRITSAR
PROVN OF CERTAIN E AND M SANCTIONED WORKS AT AIR FORCE STATION UNDER AGE (I) AF AMRITSAR
2024_MES_640336_1
AGE (I) AF/ASR/T-27/2023-2024
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE (I) AIR FORCE STATION AMRITSAR
CLASS E AND CATEGORY b(i)
8 documents required · 8 mandatory
₹500
Yes
AGE (I) AIR FORCE STATION AMRITSAR
₹26,980
Yes
18 Apr 2024
2 Feb 2024
8 Mar 2024
2 Feb 2024
1 Mar 2024
16 Feb 2024
Amount
S & F installation, commissioning and testing Polycarbonate ASTA CPRI approved OEM made Outdoor Power Supply Panel Mini. Size 700x975x525mm. The Panel shall be made of modular POLYCARBONATE THERMOPLASTIC ENCLOSURES which should be UV resistance in accordance with IEC 61439-1, clause 10.2.4:, anti-acid, anti corrosive & Shock Proof. Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262. DEGREE OF INGRESS PROTECTION IP 65 IN ACCORDANCE WITH IEC 60529 and panel should passed glow wire test 960oC in accordance with 60695-2-11 [flame retardant and self-extinguishing]. The gasket should be internally embedded made of polyurethane and Enclousers make Hensel/Clipsal. The manufacturer of panel SHALL submit a copy of TYPE TEST REPORT of a board made out of Polycarbonate thermoplastic panel in accordance with IEC 60439-1. Submit The ASTA CPRI report shall have mention of following tests performed and passed out satisfactorily Temperature Rise, Dielectric Properties, Short circuit withstand current – Rated peak, short time withstand current and Rated Conditional Short Circuit Current, Effectiveness of Protective Circuits and submit the copy of type test reports for Polycarbonate Thermoplastic Board only. Test Reports submitted of other material of construction like MS, SS will not be applicable. Each Board shall have individual routine test report of the manufacturer. The Panel Floor Mounting type with stand and suitable Copper Bus bar with Color Coding and necessary brick work complete all as specified and directed . Make- Hensel/Rittal/Emitter/Schneider/ABB.
Incomer
MCCB 250A FP 25KA THERMAL MAGNRTIC RELEASED - 1 No
Outgoings
a). MCCB 315Amp with spreader links - 1 Set ( Main )
b). 315 Amp Contactors MCX 41 - 2 Nos
c). LED indicator R/Y/B - 3 Sets
d). Multi-functional Meter ( Volt,Amp,frequency ) with 3 Nos CT Coils 400/5A - 1 No
e). Battery Charger 12V - 10Amp - 1 No
f). Control MCB SP 2Amp- 6 Nos
g). SM 500 Relay - 2 Nos
h). On Delay Tmer - 2 Nos
i). 8 Pin Relay - 1 Nos
Note :- AMF Panel with Complete all accessories for Command to D.G Auto Start/Stop and convert in D.G and Electricity.
M & L for vertical type sheet steel enclouser distribution boards, double door in replacement factory made 3 phase 415 volts 4 way with 200 amps rating copper bus bar of suitable size and PVC insulated copper jumpers from the MCCB to the out going circuits (one incoming MCCB and 12 outgoing MCBs circuits) comprising of 3 phase 4 wire of suitable rating including MCCB 125 amps, 25 KA, TP, 415 volts, 50 Hz = 01 No. and 12 Nos MCBs 6-32 Amps, complete all as specified and directed.
Supply and fixing Flexiblcable copper conductor multy stranded, electric power cables (heavy duty) 1100 Volts grade of size 35 Sqmm 4 core with necessary fixing arrangement as required at site, complete all as specified and directed.
Excavation in trenches in soft/loose soil not exceeding 1.5 meter wide and not exceeding 1.5 meter deep for laying of cables and foundation of poles etc. and getting out complete all as spceified and directed.
Returning, filling in trenches (soil) including spreading leveling and well ramming in layers not exc 25 cm thick complete all as specified and directed.
Removal of surplus excavation soil to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
M&L sand cushioning with a layer of dry river sand 80mm thick before laying of cable and 150mm thick (punned down to 100mm thick) after laying of cables, in trenches/ducts. Complete all as specified and directed Note: Punned down thickness (overall 18cm), shall be considered for measurement and payment.
M&L, locally available , sub class 'B' bricks (old size) laid flat and dry in trenches over the cable for protectionprependicular to the direction of cable adjacent to each other complete all as specified and directed.
M&L, GI pipe light grade 40mm dia bore in replacement for cable protection fixed to pole or under road/ pavement, complete including MS clamps, nuts, bolts etc all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanised iron wire 4mm as earthing lead by means of bolts nuts check nuts & washers of galvanized iron or steel , procteded by GI pipe 15 mm bore( light grade) and watering pipe 20 mm bore GI pipe (light grade ) and chamber of pcc 1:4:8 type D2 using 40 mm graded stone aggregate and coping shall be in PCC 1:3:6 type C1 using 20mm graded stone agg. 50 mm thick cover of RCC 1:2:4 type B1 using 20 mm graded stone agg. reinforced with 8 mm dia MS tor bar @ 80 mm c/c both ways including excvation and earth work and removal of surplus soil complete all as shown in electrical plate no 3 of SSR PT 1, 1991 with charcoal dust and salt complete and earth lead connected to earthing test point complete all as specified & testing on completion.
M&L for earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanised iron strip 25x4 mm as earthing lead by means of bolts nuts check nuts & washers of galvanized iron or steel , procteded by GI pipe 15 mm bore( light grade) and watering pipe 20 mm bore GI pipe (light grade ) and chamber of pcc 1:4:8 type D2 using 40 mm graded stone aggregate and coping shall be in PCC 1:3:6 type C1 using 20mm graded stone agg. 50 mm thick cover of RCC 1:2:4 type B1 using 20 mm graded stone agg. reinforced with 8 mm dia MS tor bar @ 80 mm c/c both ways including excvation and earth work and removal of surplus soil complete all as shown in electrical plate no 3 of SSR PT 1, 1991 with charcoal dust and salt complete and earth lead connected to earthing test point complete all as specified & testing on completion.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil.complete all as specified and directed.
M&L 75mm thick PCC 1:4:8 type D-2 using 40mm graded crushed stone aggr as in sub base all as specified and directed
M & L for 50 mm thick PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in sub base complete all as specified and directed.
M&L Brick work with sub class "B" bricks, straight or curved on plan exc 6 m mean radius , built in CM 1:4 complete all as specified and directed .
M&L for rendering 15mm thick cement plaster in cement mortar (1:4) with water proofing compound @ 3% by weight of cement finished even and smooth without extra cement complete all as specified and directed. Note:- WPC shall be measured and paid for separately.
Supply & laying in repair GI pipes 100 mm dia, medium grade with all necessary GI fittings laid in trenches or on walls including taking out old pipe complete all as specified and as directed by EIC.
Supply & fix, cast iron fittings bends in replacement ( of any size any radius and any angle) taper any type straight, bend increasing and decreasing or double socket etc, Tee pieces single branch piece, Y pieces double branch piece, cross piece tail , collers, caps ,plugs etc socketed or flanged conforming to IS 1538 laid in tenches or on surface( excavation earthwork , lead joints and flanged joints shall be measured and paid for separately) Fittings shall be of size upto 200 mm bore .
Supply and fix in replacement horizontal type , cast iron non return / Reflux valve for 100 mm dia pipe ISI marked PN 1.6 with GM flap and seat complete flanged at both ends including jointing and jointing material such as bolts nuts, washers, rubber gasket complete
Supply and fix,in replacement cast iron sluice valve 100 mm dia with flanged and drilled ends any pattern ISI marked, PN 1.6 class brass spindle, including joints and jointing materials bolts, nuts washers rubber gasket complete
Supply and Fixing cast iron footvalve/Strainer suitable for 100 mm dia pipe, complete all as specified and directed.
Supply and Fixing DOL Starter fully automatic suitable for 15 HP pumpset, 415 V AC complete all as specified and directed.
S & F MCB single pole, 240 Volts, C curve, 10 KA, 20 Amps (10 KA 'B' rupturing capacity) complete all as specified and as directed
M&L for sub main wiring two single core 4Sqmm(nominal area) multi-strand copper conductor FRLS PVC insulated and unseathed cable drawn in and including non metalic PVC regid conduit medium grade of suitable size with all standerd fittings, concealed including one run of continous PVC insulated stranded copper conductor FRLS cable 4 sqmm for earth continuty, including taking out and removal of old sub main wiring, complete all as specified and directed. Note:- Rate quoted shall be deemed to include cutting chases for concealed conduit and making good incement mortar(1:4) or PCC (1:2:4)
M&L for earthing complete with galvanized steel earth plate electrode of size 60cm x 60cm x 6mm thick burried directly in ground vertically at a depth not less than 2.25 metre deep below normal ground level with top edge of the plate not less than 1.5 metre below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt, filling in alternate layer and electrode connections by using galvanized earth lead wire4.00mm dia by means of bolts, nuts, check nuts and washers made of galvanized iron or steel and protected by light grade 15 mm dia GI pipe connected to main switch board or main control board, and GI pipe light grade 20 mm bore for watering and including funnel, wire mesh, RCC pit cover and PCC chamber (alongwith test point) pit with PCC 1: 2: 4 type C2 including excavation and earth work, disposal of surplus soil to a distance not exc. 50 mtr all as specified and as shown on Plate No 3 of SSR Part I, dismanteling of existing unserviceable erth pit all as specified and directed by Engr-in-Charge.
Earth Continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4 mm dia galvanised iron or steel wire
Note: The Total amount shall subject to adjustment of credit for old Materials as per Schedule of Credit.
kapoor and co
M/S SIMRAN WALIA ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .