Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.6 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹14.4 L+₹2.7 L (22.9%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹16.8 L+₹5.1 L (43.5%)Rejected-AOC | L3 | Rejected-AOC Rejected |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
23 Mar 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (I) Campbell Bay
GE (I) Campbell Bay, Army land, Campbell Bay, Great Nicobar-744302
CLEANING OF UG SUMPS, OVER HEAD RESERVORS AND ALLIED WORKS AT INS BAAZ, ARMY LAND, 3U DET AND CGDHQ-10 UNDER GE(I) CAMPBELL BAY
2023_MES_575530_2
8039/E8
Open Tender
Civil Works
Item Rate
180 days
GE (I) Campbell Bay
Please refer tender documents
8 documents required · 8 mandatory
₹500
Yes
GE (I) Campbell Bay
₹30,000
1 Apr 2023
3 Mar 2023
25 Mar 2023
3 Mar 2023
23 Mar 2023
10 Mar 2023
Amount
M&L for cleaning of RCC water tanks (inside) by dewatering the complete tank, removing the sediments settled at the bottom of tank, scraping with the help of shovels, hard brushes and physical cleaning of tanks (Reservoir) by de-scaling/brooming silt and sludge and other deposits from inner side (bottom of dome), collecting and taking them out with the help of manual labour and depositing at a distance not exceeding 50m and making the tank clean and washing properly with bleaching powder mixed with water (1:10) and applying two coats of Anti Fungal Paint (white in colour) both internally and externally and writing the date of cleaning, due date of cleaning and capacity of tank in paint (white letters on black back ground) and the inner ladder with two coats of black synthetic enamel paint of exterior quality over a coat of red oxide primer and including removing of any vegetation growth on and around the tank complete all as specified and directed at site for Capacity of Tank 50,000. Litres (OHT) Note:- (i) Work is to be executed at 18 to 25m height for ser No.1 (a) (ii) All necessary T&P, labours and materials will be arranged by the contractor
Description all as per serial item No.1 but Underground sump of capacity more than 25,000 liters upto 80,000 litres
Description all as per serial item No.1 but Onground sump of capacity more than 25,000 liters upto 80,000 litres
Description all as per serial item No.1 but Underground sump of capacity more than 15,000 liters upto 25,000 litres
Description all as per serial item No.1 but Underground sump of capacity upto 15,000 liters .
Description all as per serial item No.1 but Underground sump / Static water tank of capacity upto 5,000 liters .
M&L for cleaning of rotational moulded PVC water storage service tanks on buildings by dewatering complete tank, removing sediments settled at the bottom of tank and scraping the walls and bottom of tank and cleaning with bleaching powder solution, washing with clear water and writing the date of cleaning and due date of cleaning in white paint complete all as directed for capacity of 5000 liters. Note : (a) Service tanks needs to be cleaned once for every quater. (b) Float Valves to be removed carefully before cleaning & to be refixed after cleaning. The rates for removing & refixing is deemed to be inclusive in above quoted rates. Any damages made during cleaning to the service tank and Float Valves, Nipples, gate valves, PVC Lids, etc. of the tanks are to be repaired / replaced at no cost basis. (c) Seperate Register to be maintained by the contractor and to be duly signed by the end user each time
Description all as per serial item No.7 but capacity more than 1,000 liters and upto 2,000 litres
Description all as per serial item No.7 but capacity more than 500 liters and upto 1,000 litres
Description all as per serial item No.7 but capacity upto 500 litres
M&L for cleaning of rotational moulded RCC water storage service tanks on buildings by dewatering complete tank, removing sediments settled at the bottom of tank and scraping the walls and bottom of tank and cleaning with bleaching powder solution, washing with clear water and applying two coats of Anti Fungal Paint (white in colour) both internally and externally and writing the date of cleaning, due date of cleaning and capacity of tank in paint (white letters on black back ground) complete of Capacity upto 3000 liters. Note : (a) Service tanks needs to be cleaned once for every quater. (b) Float Valves to be removed carefully before cleaning & to be refixed after cleaning. The rates for removing & refixing is deemed to be inclusive in above quoted rates. Any damages made during cleaning to the service tank and Float Valves, Nipples, gate valves, PVC Lids, etc. of the tanks are to be repaired / replaced at no cost basis. (c) Seperate Register to be maintained by the contractor and to be duly signed by the end user each time
Dismantling existing unserviceable PVC water tanks and supply and fix PVC rotational moulded water tank two layered of following capacity hoisted and fixed in position including provision of necessary inlet/outlet/over flow pipe and connected items with the existing pipe lines complete of Capacity 2000 liters.
Description all as per serial item No.12 but capacity 1000 litres
Description all as per serial item No.12 but capacity 500 litres
Supplying, laying and fixing in replacement, CPVC pipes SDR 11 & plain CPVC SDR 11 water tubing, medium grade, of size as shown below confirming to IS-1239 [Part-1] including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, etc laid in tenches / floors or fixed to walls / ceiling / roof etc including testing and taking up / down existing unserviceable GI tubing with fittings / connections, carefully from trenches / celiling /walls/roofs etc complete all as specified and as directed,dia of pipe 20 mm bore.
Description all as per serial item No.15 but 25 mm dia bore.
Description all as per serial item No.15 but 50 mm dia bore.
M & L 3-layer PP-R Polypropylene random copolymer concealed pipes SDR 7.4 (PN16) UV stablized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors complete of 16 mm outer dia.
Description all as per serial item No.18 but 20 mm outer dia.
Description all as per serial item No.18 but 25 mm outer dia.
Description all as per serial item No.18 but 50 mm outer dia.
M & L for addition alteration in old PPR / CPVC pipe/ GI Pipe screwing, cutting, threading, fixing of fittings like union, elbow, Tees, nipples, dummy, plugs etc of upto 80 mm bore including attending any minor work regarding pipe line as per directed by Engr-in-Charge. Note:- Rates for necessary fittings like union, tees, nipples, elbow etc is deemed to be inclusive in above quoted rates
Note : An amount of ₹ 6,500.00 towards Schedule of Credit shall be deducted to arrive the Contract sum.
M/S PANNER SELVAM
KCM BUILDERS & CONSTRUCTIONS (INDIA) PVT.LTD
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .