Tender Value
₹21.2 L
EMD Value
₹42,500
Closing Date
14 May 2025, 3:00 pmClosed
Electrification work for Replacement of Borewell no. 3, 6, 13, 14, 16 & 18 with pump house and pipeline arrangement at Agra Cantt Station.
ELG-01-A04-2025-26
ELG-01-A04-2025-26
Open
Works - General
8 Months
Agra, Uttar Pradesh
₹0
₹42,500
17 Apr 2025
17 Apr 2025
A- Electrification work for Replacement of Borewell no. 3, 6, 13, 14,
Supply, laying, testing and commissioning of with material fixing and providing the Light/ FTL/C.Fan /E.Fan concealed wiring point with 2.5 Sq.mm PVC insulated and sheathed multistrand copper wire 1100 V grade, single core with 1.5sq.mm. PVC insulated copper conductor 1 for continuous earthing in recessed steel/PVC conduit pipe 25mm. 1.6mm.thick dia bend, junction box etc. with ceiling rose batten holder, flush type 5A. switches mounted on white laminated phenolic sheet 3mm. thick cover on front of MS box made of 18 S.W.G. MS sheet of suitable size complete with replastering of wall if required wiring to be done in separate circuit. (Concealed wiring to be done on walls and roof if RCC roof is already constructed surface through PVC casing caping good quality double lock type wiring may be done.
"Supply, Erection, Testing & Commissioning of Supply of material for fixing and providing 5 pin socket outlet point (3 pin + 2 pin) 5-A/230 V. with flush type 5 Amp. Socket combined 2 type with switch in concealed wiring by 2.5 Sq. mm. PVC insulated multistranded copper wire single core 1100 V. Gr. in recessed steel conduit pipe 25 mm. dia & 1.6mm. thickness with 5 Amp. /230 V. flush type switch fixed on white phenolic laminated sheet 3mm. thick cover on front of MS box of suitable size complete including 1.5 Sq. mm. PVC insulted copper conductors for earthing and replastering of wall. "
Supply, erection, Testing &Commissioning of concealed wiring point of 6 pin (3 pin 15Amp. + 3 pin 5 Amp.) power socket flush type 15 A/5 A -230 V. comprising of switch 15 Amp. & 3 recessed MS conduit wiring or in casing caping PVC double lock type of good quality with suitable wooden board well polished by 4 sq. mm. PVC insulated multistrand copper cable 1100 V. grade single core including 1.5 sq. mm. PVC insulated copper conductor for earth wire, mounted on white phenolic laminated sheet 3mm. thick cover on front of MS box 1.6mm thickness complete with replastering of wall. (Separate circuit to be drawn from SDB.)
Supply, Erection, Testing and commissioning of MS/PVC conduit pipe 25mm dia and 1.6mm thick, recessed in the wall and through the wall by making hole and replastering the same in original condition complete with Tee, elbow, junction box, sadle & Other accessories for sub main wiring.
Supply, erection, Testing & Commissioning of sub main consisting of 2x4 Sq. mm (P & 5 N) PVC insulated and sheathed copper wire multristanded single core 1.1KV grade alongwith 1.5 Sq. mm PVC insulated copper wire 1.1 KV grade for earthing. (Quantity 1 Mtr. Equal to 02 Nos., wire of 4 Sq.mm of 01 Mtr.each. and 01 No. earth wire 1.5 Sq. mm. of 01 M) (No cable joint is permitted inside the MS conduit pipe cable should be jointed with cable connectors inside the switch board)
"Supply, erection, Testing & Commissioning of energy efficient luminaire complete 6 with all accessories , 18/20 watt, 04 feet LED tube light fitting & Tube with suitable current control driver circuit, suitable for surface mounting and connection with PVC copper flexible wire of 23/76 as per Rly. specification attached "
Supply, erection, testing and commissioning of single earth electrode of 50mm. dia 7 3000mm long GI pipe class B conforming to IS: 1239 latest complete with earth box with cover as per RDSO approved drawing including connection from earth electrode to MDB/ SDB/poles/with 8 swg GI wire
Horizontal boring of cable duct at 1.4 to 2.1 mtr.depth from the bottom of sleeper 8 /ground lable and laying of 120 mm dia HDPE DWC pipes for cable crossing under track / road .The work shall be done as per extant practice and instruction of site engineer.It includes supply of DWC/HDPE pipes conforming to IS14930(Part:2:2001)
Excavation of cable trench:- This item shall be operated in conformity with IS:1255 (latest version) i.e. code of practice for installation and maintenance of HT/LT cables. The price shall cover cost of excavation of cable trench in all type of soil for laying LT cables and back filling the same with sieved earth and finishing the surface in its original condition after providing sand, & bricks in cross position. For LT/HT cables the trench shall be 600mm wide x 1000mm deep. In trench 9 the cable shall be covered with river sand at a depth of 100mm below the cable and 100mm above the cable than placing well-burned bricks continuously in cross-position through out the cable route in the ground. The bottom of the trench should level free from stones and sharp edge of rocks etc. At the termination a loop of 5 meter (approx) cable shall be kept as allowance and loops rings be formed as per the site condition, in the ground, The cost shall include the cost of all materials i.e. sand, bricks, cable route markers (grouted in the earth firmly with cement concrete so that it can not be uprooted by miscreants) etc at 25m. interval and each turn of the cable.
supply, erection, Testing & Commissioning of energy efficient LED street light fitting 10 60 Watt outdoor complete street light fitting pressure die cast aluminium (PDC) body with make embosed on PDC body and complete with all accessories/ components and connection with PVC copper wire 2.5sq. mm size multicore and fixing arrangement as per site requirement.The technical parameters will generally conform to relevant Railway specification attached Annexure-II
"Laying/Cleating erection, Testing & Commissioning of HT/LT Cable 03/04 Core on wall with all accessories & refilling of cable trench (as per IE rule) after laying of cable (Cable will be supplied by Rly free of cost at Cosignee Depot) "
Supply, Erection, Testing and commissioning of On-Load Changeover switches frame 2, 4 pole 630Amp in sheet steel enclosure (Ref E-CSCS630K4CO)
"Supply, Erection, Testing and commissioning of Electrically Driven Submerssible pump Set 4/5 star rated water lubricated of following capacity 3 phase 50Hz 415 Volt AC Supply capacity 10 HP, Discharge Size 75mm dia suitable for 200mm bore as per site requirement"
Supply Erection, Testing & Commissioning of 3 phase 50Hz, 415 Volt 10 HP panel wall mounted type made of 16SWG MS Sheet duly painted with double coat of stove enameled paint and one coat of primer paint, dust proof, vermin proof with locking arrangement and comprising of the following Items duly mounted on Bakelite sheet (05mm. thick) of suitable size . 1. Fully automatic 14 star/delta starter 2. Over load relay range 130to 18 Amp. 3. Electronic single phase preventer with in built 45 ± 5 Sec. facility. 4. Motor on/motor 'TRIP' Neon lamps. 5. Auto/Manual switch. 6. By pass switch forSPP. 7. Am meter range 0-50 A with selector switch8. Voltmeter size 96 x 96mm range 0 - 500 V. AC 9. Motor 'ON'/Motor 'OFF' push button. 10. In comer TP miniature circuit breaker 40 A. 11. Three phase (R,Y,B) Neon lamps. 12. Volt meter selector switch (VSS) 13. Connector strip. 11 way. 14. No. volt coil voltage 250 V. - 440 V. 15. Timer 1-30 Sec.
"Supply, Erection, Testing and commissioning of Super Nylon Rope 12mm conforming to IS: 4572: 2104 (Latest)."
"Supply, Erection, Testing and commissioning of water proof flat Submersible cable 16 size 3 core X 6 Sqmm copper conductor 1.1KV grade PVC insulated & Sheathed conforming to IS- 694/1994 (latest) to be laid from starter to well cable to be laid through MS conduit pipe ( Heavy gauge ) of suitable size with fixing accessories."
"Supply, Erection, Testing and commissioning of Upvc coloumn pipe, type super heavy, dia 60mm (2 inch), efective length 3m per pipe with all fixing accessories"
"Supply, Erection, Testing and commissioning of Electrically driven submersible 18 pumps set 4/5 star rated water lubricated of following capacity-3 phase 50 HZ. 415 Volt AC supply. capacity 15 HP.2880RPM., Head 110M to 150M approx., Discharge 250 - 400 LPM, Delivery size 75mm.dia. suitable for 200mm. bore as per site requirement"
"Supply Erection, Testing & Commissioning of control panel wall mounted type made of 16SWG MS Sheet duly painted with double coat of stove enameled paint and one coat of primer paint, dust proof, vermin proof with locking arrangement and comprising of the following Items duly mounted on Bakelite sheet (05mm. thick) of suitable size . 1. Fully automatic star/delta starter 415 19 V.3Phase-15HP to 20HP 2. Over load relay range 16- 25. 3. Electronic single phase preventer with in built 45 ± 5 Sec. facility. 4. Motor on/motor 'TRIP' Neon lamps. 5. Auto/Manual switch. 6. By pass switch for SPP. 7. Am meter size 96 x 96mm. range 0 - 100 A. with selector switches (03 Nos.) 8. Voltmeter size 96 x 96mm range 0 - 500 V. AC 9. Motor 'ON'/Motor 'OFF' push button. 10. Incomer TP miniature circuit breaker 40 A. 11. Three phase (R,Y,B) Neon lamps. 12. Volt meter selector switch (VSS) 13. Connector strip. 11 way. 14. No. volt coil voltage 250 V. - 440 V. 15. Timer 1-30 Sec."
"Supply Erection, Testing & Commissioning of heavy duty uPVC column pipe, blue screened (one side threaded and having rubber seal & one side having inbuilt inner threaded socket and rubber seal, dia 90 mm. (3 inch), efective length 3m. Per pipe with all fixing accessories"
Supply Erection, Testing & Commissioning of Top & Bottom adaptor set of stainless steel suitable for 3" dia uPVC pipes.
Supply, Erection, Testing and commissioning of SIGRI (Lowering jig) suitable for 2'' diameter PVC pipe
Supply, Erection, Testing and commissioning of SIGRI (Lowering jig) suitable for 3'' diameter PVC pipe
Supply, erection, Testing & Commissioning of constructed, Installation Testing and Commissioning of Maintenance Free Earth as per RDSO Spec.No.RDSO/SPN/197/2008 or latest consisting the following , A) Copper bonded steel electrodes of 3.0 meter long & 17.2mm.dia with Cu- bonding thickness of min.250 microns and UL listed and marked=1No. B) Earth enhancement material supplied in sealed bags of in.10Kgs.=3Nos. C) Copper strip 150x25x6 mm. to terminate earth rod=1No. D) Copper strip 300x25x6 mm. Main LT panel board to terminate earth rod =1No E) Copper strip 150x25x6 mm. Sub distribution board to terminate earth rod =1No F) Digging the earth to the required depth G) Insertion of electrode H) Filling of earth enhancing compound (30Kg.) - provision of exothermic weld connection on copper tape of 25mmx6mm.x150mm.to the earth electrodes all the materials, tools and features required for the weld to be arranged by the 24 contractor-1No. Note:-Earth pit should be prepared as per RDSO. DRG. No.SDO/RDSO/L&B/001 I) Provision of Exothermic weld connection in copper tape 25mm.x6mm.x150mm. to the earth electrodes . All material, tools and features requires for the weld to be arranged by the contractor J) Provision of Exothermic weld connecting ,One to connect 35 Sq.mm multistranded single core PVC insulated copper cable to the copper tape welded to the earth electrode and another to the copper tape (Main LT panel board) to be fixed inside the equipment / Escalator apparatus room,weld materials, tools and features and all other materials requires for the weld to be arranged by the contractor K) Electrode termination in a concrete sink and routing the cadmium cable to bus bar in equipment room ( all other materials required for the work shall be brone by the contractor Note:- Earth resistance should be less than One Ohm. L) MDB & SDB are to be installed in equipments/Panel room and earth connections to equipments cables extended from LT panel board and Sub distribution board as the case may be .
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .