Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.4 LAccepted-AOC HOUSE NO 15E ROAD NO 12 RAJENDRA NAGAR PATNA BIHAR 800016 | PATNA | PATNA | BIHAR | 800016 | L1 | Accepted-AOC ok | |
| 2 | L2₹17.6 L+₹3.1 L (21.7%)Rejected-Finance VILL PO MANOHAR CHHAPRA MOTIPUR DISTT MUZAFFARPUR PIN 843111 | MOTIPUR | MUZAFFARPUR | BIHAR | 843111 | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | Rejected-Technical H NO 400 FLAT NO 13 A SEMATILLA DIMAPUR 797112 NAGALAND | DIMAPUR | DIMAPUR | NAGALAND | 797112 | - | Rejected-Technical Being not enlisted in appropriate category of work. |
Tender Value
Refer Docs
EMD Value
₹34,800
Closing Date
21 Sept 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Bihta
GE (AF) Bihta PIN 801103
Provn of certain Minor works at AF Stn Bihta under GE (AF) Bihta
2021_MES_463723_2
8174/BHT/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Bihta
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) Bihta
₹34,800
Yes
20 Nov 2021
30 Aug 2021
23 Sept 2021
30 Aug 2021
21 Sept 2021
6 Sept 2021
60 days
Amount
1. Supply and fixing Tripod Earthhing(3 Set earthing inter connected to 1 set) maintenance free Earthing Solutions comprising with the followings:- (i) Supply and fixing after digging bore of suitable size the CPRI tested and UL certified maintenance free earthing system having a set of copper bonded Earth Rod of 3 meter length, 17.2 mm dia made of high tensile low steel circular rods,molecularly bonded with 99.90% electrolytic grade copper on outer surface(minimum copper bonding thickness-250 microns)with exothermally jointed copper bus bar of 200X25X6mm for long lasting and connection.Earth Copper bonded rod & exothermically jointed bus bar should be CPRI tested on 25KA fault current complete all as specified and directed by Engineer-in-Charge for complete connections.-Qty 3 Nos.
(ii) Earth Copper bonded Electrode should be tested by CPRI, Bangalore (iii) Current carrying capacity of EarthCopper bonded Electrode is 25KA/Sec. (iv) Supply and filling of carbon based ,eco friendly earth enhancing compound of RHOS tested compound tested by NABL accredite Lab in compliance to IEC 62561-7 and having passed leaching,sulphur,corrosion resistivity test as per IEC 62561-7 an international standard for earth enhancement compound in compliance to IEC 62561-7 with a resistivity < 0.12 ohm-m ,25 kg of Jam Lite/Equivalent.Qty- 3 nos. (v) Earth enhancing compound shall be free from corrosion,it shall be carbon based material and shall be free from bentonite and other hazardous substances.The product does not dissolve,deteriorate or leach out of time.It shall be highly conductive and improves earth's absorbing power and humidity retention capability,It shall be eco-friendly and chemically inert to sub soil. (vi) Supply and fixing plastic Earth pit Cover of size 247mmX338mmx210mm having load bearing capacity of 8 Ton and complying IEC 62561-5.-3Nos. Note:-On testing,after completion of job ,if desired earth resistence is not found i.e. below 1.00 Ohms ,the earthing shall be redone on no extra cost to govt. Make : JMV LPS LTD/ENNOV or equivalent as approved by GE.
Supply & fixing copper strip 20mm x 3.15mm with saddles and fixing screws for roof conductors and down conductors above ground to extend earthing from pit to building wall complete all as specified and directed.
M & L test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed.
Supply and Fixing single core PVC insulated 16 sq.mm multi stand flexible copper cable 1100 volts conforming to IS 694 as down conductor including provision of suitable clamps /saddles etc complete all as speciied and as directed by Engineer-in-Charge Make -Havells Cat Part No-WHFFDN G1016 or equivalent in polycab/Finolex.
Material and labour for point wring ,using approved colour coding (Phase-red,Neutral-black,Earth-green) complete for one socket outlet 15 Amp on independent board with FRLS PVC insulated and unshealthed stranded copper conductor cable 2.5 sqmm single core conforming to IS 694 including medium duty concealed unplasticised PVC conduit conforming to IS 9537(part-3) and ISI marked not less than 20 mm dia with concealed in wall pressed steel terminal box of not less than 2 mm thick of required size including painting terminal boxs inside and outside with two coat of synthetic enamle paint over one coat of red oxide primer with top cover 3 mm thick bakelight laminated sheet with brass screws and Cup washer with all assessories including FRLS PVC insulated and unshealthed stranded copper conductor cable 2.5 sqmm FRLS single core in green colour as earth wire connected to earth dolly complete all as specified and directed by engineer-in-charge.
S&F switch socket combination 2 in 1, 3 pin , 5 & 15 Amps flush type universal , 240 Volts complete all specified Make:- Havells/Legrand/HPL/Plaza
S&F sheet metal enclosures (MCB Distribution board) when MCB’s to be used single pole and neutral 8 ways 220 volt with 200 amps rated bus bar, double door with bus bar neutral link earth bar, Din rail, necessary blanking plated, including fixing DB flush in wall complete and making good disturbed surfaces a per existing all as specified and directed. Make: Havells/Legrand/GE/ABB
S&F MCB’s single pole & neutral 40 to 63 Amp 240 Volts, connecting with copper lugs complete all as specified and directed. Make: Havells SPN Cat No DHMGCSNF063 or equivalent in Legrand/Schneider/ABB
S&F MCB’s single pole 10 Amp to 25 Amp 240 Volts, connecting with copper lugs complete all as specified and directed. Make: Havells SP Cat No DHMGCSPF006-032 or equivalent in Legrand/Schneider/ABB
S & F sub main wiring using approved colour coding (Phase-red,Neutral-black,Earth-green) complete with two single core FRLS PVC insulated and unshealthed stranded copper conductor cable 4 sqmm as current carrying conductor and one run of 4.0 sqmm as earth contunity conductor ,voltage rating 1100 volt ,ISI marked drawn in and including concealed PVC conduit ISI marked of dia not less than 25 mm and thickness 2 mm with stranded accessories along with one run of FRLS PVC green colour insulated,unshealthed,stranded copper conductor of size 4 sqmm all as specified and directed. Make:-RR Kable/Finolex/Universal/Grandly Note: Two run of single core FRLS PVC cable with one run of earth contunity conductor and conduit shall be measured as one unit.
S & F sub main wiring using approved colour coding (Phase-red,Neutral-black,Earth-green) complete with two single core FRLS PVC insulated and unshealthed stranded copper conductor cable 6 sqmm as current carrying conductor and one run of 6.0 sqmm as earth contunity conductor ,voltage rating 1100 volt ,ISI marked drawn in and including concealed PVC conduit ISI marked of dia not less than 25 mm and thickness 2 mm with stranded accessories along with one run of FRLS PVC green colour insulated,unshealthed,stranded copper conductor of size 6 sqmm all as specified and directed. Make:-RR Kable/Finolex/Universal/Grandly Note: Two run of single core FRLS PVC cable with one run of earth contunity conductor and conduit shall be measured as one unit.
M&L for earthing complete with galvanized steel earth plate 600x600x6 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised iron strip 32x6 mm dia as earthing lead by means of bolts, nuts, check-nuts, and washers of galvanised iron or steel besides welding at all joints as shown in drawings and including excavation and earth work, GI pipe light grade 40 mm bore for protection of GI strip from earth electrode to and including the earth test point of galvanised Iron/steel . supplying and laying charcoal stone aggregate) chamber and RCC cover of size 54x54x50 mm (1:2:4) type B1 using 20 mm graded crushed stone aggregate reinforced with 8 mm dia TMT bars @ 75mm C/C both ways with mild steel handle 12 mm dia, PGI funnel with wire mesh, 20 mm dia GI pipe medium grade for watering all as shown in drawing including taking out the old one. Note - Cost of GI strip and GI protection pipe up to a distance 7.5 M shall be included in quoted rate of above Item.
Supply & fix Aluminium strip 25mm x 3.15mm with saddles and fixing screws for roof conductors and down conductors above ground to extend earthing from pit to building wall complete all as specified and as directed
Supply and filling GRAPHITE & PORTLAND CEMENT based Earthing Solutions comprising with the followings: (i) 01 No.Earth Electrode (17.2 mm dia, 3 mtrs long solid rod of Low Carbon Steel, molecularly Copper Bonded for a thickness of 250 micron integrated termination clam. (ii) Earth Electrode should be tested by CPRI, Bangalore (iii) Current carrying capacity of Earth Electrode is 25KA/Sec. (iv) 03 bags / 30 Kgs. Graphite & Portland based EGEM Ground Enhancing Material per pit. (v) EGEM is graded granular carbonaceous compound (as per clause 8.5 of BS 7430:1998)
(vi) Conductive Concrete in nature (as per clause 9.2.2 of BS 7430:2011) (vii) Resistivity of EGEM is ≤ 0.12 Ω-m (as per clause no. 14.5d of IEEE-80:2000 ) (viii) Conforming with IS 3043:1987 Clause 9.2.2 (ix) Conforming with BS 7430:1998 Clause 8.5 ( C ) (x) Conforming with BS 7430:2011 Clause 9.2.2 (xi) Conforming IEC 62561-7:2011 Clause 5.1, 5.2, 5.3,5. 4.5.6 etc. (xii) Having Test Report from NABL accredited Laboratory. (xiii) Never needs recharging (xiv) EGEM is not contains any hazardous chemicals Note:-On testing,after completion of job ,if desired earth resistence is not found i.e. below 1.00 Ohms ,the earthing shall be redone on no extra cost to govt. Make : ENNOV or equivalent as approved by GE
Supply and fix Polymer Earth Pit Inspection Chamber: (i) Top Diameter : 256 mm (10.07 Inch) (ii) Bottom Diameter : 348 mm (13.70 Inch) (iii) Total Height :260 mm (10.24 Inch) (iv) Top working Area Diameter 211 mm(8.31 Inch) (v) Weight : 2 kg (4.40 LBS) (vi) Lead Bearing capacity: 5000 Kg (05 Ton) Make:-ENNOV or equivalent as approved by GE.
Excavation in post holes (or similar holes) each not exc 0.50 cum getting out in any type of soil for fencing posts returning, filling in and ramming earth or broken rubble mixed with earth around, in layer not exceeding 25 mm complete all as specifed and directed
Excavation in trenches n exc 1.5 m wide & n exc 1.5 m in depth for foundation and getting out in soft/loose soils complete all as specifed and directed
M&L for PCC 1:3:6 type C-1 (using 20 mm graded stone aggregate ) as in foundation, filling & mass concrete complete all as specifed and directed
M&L for PCC 1:4:8 type D-2 (using 40mm graded stone aggregate ) as in foundation, filling and mass concrete complete all as specified and directed
M&L for PCC 1:2:4 type B-1 (using 20mm graded stone aggregate ) as in walls, retaining walls any thick , any size, shape complete all as specifed and directed
M & L for fromwork to sides of concrete foundation, footing, bases of coloumns, etc vertical or to batter, fair finished surfaces of concrete complete all as specifed and directed
S&F angle iron fencing post and struts including cutting tops to shape as directed, drilling holes, notching for wire etc , flat iron fillets ( for securing wire mesh etc) including all necessary drilling, bolting or riveting etc and similar work conforming to Fe-410-0 or Fe 310-0 all as specifed and directed
Returning filling in, including, spreading, levelling,watering & well ramming in layers nexc 25 cm complete all as specifed and directed
Removing excavated material to a distance not exc. 50m and deposited where directed at a level not exc. 1.5m above starting point complete all as specifed and directed
S&F MS Screw bolts ( machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut length exc. 5 cm but not exc 10 cm long 11 to 15mm dia of shank complete all as specifed and directed.
Supply only chain link MS galvanised fencing of mesh size 100 x 10 mm and dia of wire 4 mm complete all as specifed and directed
Fixing only chain link fencing including line wires, of mesh, size 100x100 mm and dia 4 mm to any type of standards, sails, straining bolts etc including provn of binding wire complete all as specifed and directed Note:- Srl item No 26 & 27 BOO shall be detailed to check/ verifty the actual wt of chain link fencing before fixing/making payment.
M&L for ms round bars 10mm dia and over cut to length bent to shape required incl cranking, bending spirally for hoping for columns, hooking ends and binding with and incl MS Wire (annealed) not less than 0.9mm dia or securing with clips complete all as specifed and directed.
M & L for Framed work as in doors or gates of angle or other section with gusset plates, rails braces etc complete drilled for fixing of steel sheeting or other covering . To be prepared for hanging, or sliding with and incl either hooks and hinges or steel hanging door fittings(exclusive of steel sheeting or other covering) running rails and guides and haninging also fastening and fixig complete conforming to FE-410 W (GDE-E-250) Quality-A omplete all as specified and directed
M&L for prepration of new steel surface of any description over 10 cm width or girth and two coats of synthetic enamel paint over a coat of red oxide primer complete all as specifed and directed
M&L preparing new steel surfaces of any description, n.exc 10 cm in width or girth and applying two coats of syn thetic enamel paint over a coat of red oxide primer complete all as specified and directed
M & L for reinforced cement concrete design mix M-25 (using 20 mm graded stone aggragets) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, basement slabs, under-reamed piles and mass concrete etc complete all as specifed and directed
M&L for Formwork to sides of pillars, posts, struts, piers, columns and stanchions square or rectanguler for fair finished surface of concrete complete all as specifed and directed
M&L for reinforced cement concrete design mix M-25 (using 20 mm graded stone aggragets) as in Columns, pillars, piers, posts and struts complete all as specified and directed.
M&L for MS TMT bars 10mm dia and over cut to length bent to shape required incl cranking, bending spirally for hoping for columns, hooking ends and binding with and incl MS Wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for MS TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders cut to length bent to shape required incl cranking, bending spirally for hoping for columns, hooking ends and binding with and including MS Wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L rendering 10mm thick on fair faces of brick work or concrete surfaces in cement mortor 1:4 complete all as specified and directed
M&L for prepration of new plastered surface of walls and applying two coats of cement base paint over a coat of primer complete all as specified and directed
M/S ANAND MOHAN ENTERPRISES
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .