| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.1 CrAccepted-AOC 1354 VIJAY NAGAR COLONY NILVANDI ROAD NEAR SWAMI SAMARTH KENDRA TAL DINDORI DIST NASHIK DINDORI 422202 | DINDORI | NASHIK | MAHARASHTRA | 422202 | ₹40.1 Cr | L1 | Accepted-AOC Accept |
| 2 | L2₹40.3 CrRejected-AOC | ₹40.3 Cr | L2 | Rejected-AOC Accept |
| 3 | L3₹41.1 CrRejected-AOC | ₹41.1 Cr | L3 | Rejected-AOC Accept |
| 4 | L4₹42.2 CrRejected-AOC 224 KAILASH NAGAR SHOBHAPUR COLONY DISTRICT BETUL MADHYA PRADESH PIN 460449 | BETUL | MADHYA PRADESH | 460449 | ₹42.2 Cr | L4 | Rejected-AOC Accept |
Tender Value
₹49.3 Cr
EMD Value
₹24.6 L
Closing Date
12 Jun 2023, 6:55 pmClosed
Executive Engineer PWD Amravati.
Executive Engineer PWD Amravati.
CONSTRUCTION OF DISTRICT LEVEL CENTRAL ADMINISTRATIVE BUILDING AT AMRAVATI
2023_PWR_903739_1
PWD/AMT/2023-24/2/2
Open Tender
Civil Works
730 days
Amravati.
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,540
₹24.6 L
Chief Engineer P.W. Region, Amravati.
13 Oct 2023
13 May 2023
14 Jun 2023
13 May 2023
12 Jun 2023
13 May 2023
29 May 2023
Amount
CONSTRUCTION OF DISTRICT LEVEL CENTRAL ADMINISTRATIVE BUILDING AT AMRAVATI
Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means
Excavation for foundation in hard murum including removing the excavated material upto distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.50 m) By Mechanical Means
Excavation for foundation in Hard murum and boulders including removing the excavated material upto a distance of 50 metres, beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5 m to 3.0 m.) By Mechanical Means
Conveying materials obtained from excavation upto a lead of 3 km including all leads,lifts,royalty etc complete
Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Providing and laying Cast in situ/Ready Mix cement concrete in M15 of trap/ granite/quartzite/gneiss metal for foundation and bedding / steps including steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface, only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.),with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering, formwork ,cover blocks, laying/pumping, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with concrete Batch mix plant (Pan mixer) etc. complete. With 70% natural sand and 30% VSI grade.
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap metal for R.C.C. columns as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with concrete Batch mix plant (Pan mixer) etc. complete. With 70% natural sand and 30% VSI grade. Ground Floor
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLCconcrete Batch mix plant (Pan mixer) etc. complete. With 70% natural sand and 30% VSI grade. Ground Floor , Canteen
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. Main Building Ground Floor, Canteen,Sump Well, Parking Shade, Compound Wall, Entrance Gate , Flag Post
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Providing fly ash brick masonry with conventional / I.S. type fly ash bricks in C.M. 1:6 in foundation and plinth including bailing out water manually striking joints, racking out joints watering and scaffolding etc. complete. Ground Floor, Canteen
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percent of chlorophyrifos per square meter of surface area covering 10 years guarantee on bond paper. Ground Floor , Canteen
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) treatment by treating the backfill in immediate contact with foundation at the rate of 5 litres of emulsion concentrate of 1.0 percent of clorophyrifos per One Square Metre of vertical surface area covering 10 years guarantee on bond paper. . Ground Floor , Canteen
Filling in plinth and floors with approved excavated material in 15cm. to 20cm. Layers including watering and compacting etc. complete. Ground Floor , Canteen
Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc. complete. Ground Floor , Canteen
Providing soling using 80 mm size trap metal in 15 cm. layer including filling voids with Crushed sand/grit, ramming, watering etc. complete. Ground Floor , Canteen, Parking Shade, Compound Wall , Flag Post
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate at 1.0 percent of clorophyrifos per One Square Metre of surface area covering ten years guarantee on bond paper . Ground Floor , Canteen
Providing and fixing during laying in RCC Slab rectangular 2 mm thick M.S. sheet fan hook box of size 180x100 mm with required depth with holes or notches as required, bottom and top sides of 1.6 mm M.S. sheet fixed with 3.5 mm dia. round headed screws together with 12 mm dia. M.S. bar bent to shape with hooked ends for fan hook and painting to exposed surface . Ground Floor , Canteen.
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with concrete Batch mix plant (Pan mixer) etc. complete. With 70% natural sand and 30% VSI grade. Ground Floor , Canteen.
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Providing and laying Cast in situ/Ready Mixcement concrete M-25 of trap metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with concrete Batch mix plant (Pan mixer) etc. complete. With 70% natural sand and 30% VSI grade. Ground Floor , Canteen.
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap metal for R.C.C. pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with concrete Batch mix plant (Pan mixer) etc. complete. With 70% natural sand and 30% VSI grade. Ground Floor.
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap metal for R.C.C. Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based PLC with concrete Batch mix plant (Pan mixer) etc. complete. With 70% natural sand and 30% VSI grade.Ground Floor.
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap metal for R.C.C. fins of required thickness in position as shown on the drawings or as directed by Engineer-in-charge including steel centering, plywood / steel formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement, including cover block) Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. with fully automatic micro processor based PLC with concrete Batch mix plant (Pan mixer) etc. complete. With 70% natural sand and 30% VSI grade. Ground Floor
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M20 of trap metal for plain or molded sills, cornice, jambs, block in course, or architraves of required size and shapes including steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided,finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.) with fully automatic micro processor based PLC with concrete Batch mix plant (Pan mixer) etc. complete. With 70% natural sand and 30% VSI grade. Ground Floor , Canteen.
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-15 of trap metal for coping to plinth or parapet, moulded or chamfered as per drawing or as directed including steel centering, plywood/ steel formwork compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.) With 70% natural sand and 30% VSI grade. Third Floor
Compound wall Ground Floor
Providing first class Burnt Brick masonry with conventional / I.S. type bricks in cement mortar 1:4 including scaffolding, racking out joints pointing in C.M. 1:3 and watering in pillars of rectangular or square shape as shown on the drawing or as directed etc.complete. Ground Floor , Canteen.
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Providing and applying Texture plaster with finishing with texture material of approved make in 3 to 4 millimeter thickness on previously plastered surface, including Plaster Groove 6mm thickness or Tape Grooves 35 to 45 mm thickness or as required, in all position including preparing the surface, scaffolding etc. complete. Ground Floor , Canteen
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Providing Autoclaved Aerated Concrete Block masonary of conforming to IS:2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in superstructure including striking joints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972) Third Floor
Providing fly ash brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete. Ground Floor , Canteen , Sump Well , Compound Wall , Entrance Gate .
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Providing Second class fly ash brick masonry with conventional / I.S. type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of two bars of 6 mm diameter / two hoop iron strips 25 mm x 1.60 mm at every third course, properly bent and bounded at ends scaffolding raking out joints and watering etc. complete. Ground Floor , Canteen .
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete /B.B.masonry and or tying by binding wire etc. complete. Ground Floor , Canteen
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. Ground Floor , Canteen , Sump Well , Compound Wall , Entrance Gate .
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Providing internal cement plaster 20mm thick in Single coats in cement mortar 1:4 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc.complete. Main Building Ground Floor , Canteen
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. Ground Floor , Canteen , Sump Well , Entrance Gate
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete. Ground Floor , Canteen , Flag Post
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Providing and Laying factory made coloured chamfered edge Cement concrete grass paver blocks of required strength,thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of fine fine aggregate (natural sand/crushed sand VSI grade finely washed etc.), compacting and proper embedding/laying of inter locking paver blocks into the fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) and cutting of paver blocks as per required size and pattern, finishing and sweeping extra fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) and complete as per manufacturer spsecifications & direction of Engineer-in-Charge. 60mm thick CC paver block of M-35 grade concrete with approved colour and design & pattern. Main Building Ground Floor
Providing and laying vitrified mirror / glossy finish tiles decorative type having size 900 mm x 900 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete. (Vitrified Matt finish 900x900) Ground Floor
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Providing and laying vitrified rustic matt stone finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10mm thickness and confirming to IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete. Ground Floor
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Providing and laying vitrified mirror / glossy finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete. (Vitrified Matt Finish 900x900mm) Ground Floor
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Providing and fixing machine cut machine polished 18 mm to 20 mm thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with full moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete. Ground Floor, Canteen , Flag Post
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Providing and laying vitrified matt fininsh tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc. complete. Ground Floor
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Providing and laying vitrified matt finish tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete. Ground Floor
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Providing, laying and fixing exterior grade fibrilling fibre reinforcement heavy duty designer cement concrete tiles for Flooring of approved colour and design 22 +/ -2 mm thick bayer colour pigmented as per IS ..1237 - 1980 having compressive strength more than 500 Kilogram/sq.cm reaffirmed in 2006 ,having wert transvrse strenghth of 3.5 / mm 2, water absorption less than 10 % abrasion / wear resistance less than 2 mm ,skid resistance more than 25.0 (ASTM:E303) and no fading as per DIN - 51094 of size 300 x 300 in plan / designed pattern on a bed of 1:4 cement mortar including cement float ,filling joints with neat cement slurry ,curing, polishing and cleaning etc. complete. For flooring. Ground Floor
Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler One Numbering/moulding the sharp edges wherever necessary, curing, etc. complete. Ground Floor , Canteen, Sump Well , Entrance Gate.
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Providing and fixing machine cut mirror polished 18 mm to 20 mm thick telephone black granite / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone partition with full moulding the edges etc. complete . Both side polish Ground Floor, Canteen.
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Providing 25 mm to 30 mm thick partition of polished black kadappa stone slab of approved quality including giving required size and shape etc. Fixing in cement mortar 1:3 curing and cement etc. complete. a) One side polish. Ground Floor , Canteen.
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Providing and fixing machine cut mirror polished 18 mm to 20 mm thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone partition with full moulding the edges etc. complete. One side polish .Ground Floor
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
PRIVIDING AND FIXING ACOUSTICAL FALSE CEILING WITH 0.7 NRC: Sierra Mineral Fibre Acoustical Suspended Ceiling System with 13mm thick Microlook Edge Tiles with 15mm face exposed grid. The tiles shall have smooth laminated salt pepper visual with Humidity Resistance (RH) of 95%, NRC 0.7 (Average value of Absorption Co?efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) as per ASTM C423 standard, CAC of 28db as per ASTM E1414, Light Reflectance ≥85% as per ASTM E?1477, Thermal Conductivity λ = 0.037W/mK, Colour Global White, Fire Performance of class A2-s1, d0 according to EN 13501-1 with 13mm Microlook edge and 8mm drop in module size of 600 x 600mm. The scrim on the face of the tile shall be cleanable. The tiles shall be classified as ISO 14644-1 cleanroom class 5. It shall be suitable for Green Building application, with Recycled content of 60%. The tile shall have certifications from GRIHA and GreenPro thereby confirming that it is an environment friendly product. SUSPENSION: The tile shall be laid on 15 mm wide T - section flanges colour global white (matching to tile color) having roll formed double stroke rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 38mm (all sections). The deflection loading of the system shall be 12.5 kg/m2 (as per standard installation layout mentioned below) and main beam tested as per ASTM C635 (Deflection limit less than L/360) with a deflection loading of 15kg/m. The end details of the cross tee shall be made of pre hardened steel and fixed to the ends of the cross tee to provide double locking between “cross tee to cross tee” and “cross tee to main beam”. All main beam to main beam and cross tee to cross tee connection shall have a pull out strength of more than 100kg. The T Sections shall be made of hot dipped galvanized steel of 90 gsm as per IS 277 (2003) and pre-painted steel with baked polyester paint with 0T bending capability. All border cross tee/main beam shall be levelled using perimeter fill. The Tile & Grid system used together shall carry a 10 year warranty against manufacturing defect and manufacturer shall provide a warranty certificate. The Tile & Grid shall have the manufacturers name embossed/printed on it. The supply shall be backed by a Manufacturing Test Certificate. Ground Floor
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
ACOUSTICAL WOODWOOL WALL PANELLING: Providing & fixing of 100% Natural Material- Magnesite (Hygroscopic & biologically sound binding agent) bonded woodwool Heradesign planks of 600Mm*1200Mm *25Mm thickness made out of wood wool fibre of width 1Mm Fiber thickness mixed with Natural water & Magnesite (No-Cement) with open & smooth surface texture, Weight of panel to be 11.3 Kg/m2. A Completly harmless Envirenment & Human Friendly & also a disposable or recyclable Material & can last for more than 80 Years in building interiors As it has long lifespan & suitable for Indoor conditions with relative air humidity of upto 90%. Magnesite protects the wood cells against ageing & fungal attack. To achive upto NRC=1.00 it should be a clear gap of 200Mm from wall slab along with the backing of Mineral wool of 50mm thick with 64 kg/m3 density. Ecologically Sound Material with high mechanical strength with Crash test of 90Km/H with Ball Impact Test DIN18032 & EN13964 with flying colors & A sustainable material (PEFC & FSC Certified) along with EPD Certified Acc. to EN ISO 14025 (AUB-Envirenmental Product declaration). Manufacturing tolerance for nominal size: Length, Width & Thickness ± 1 mm, & In a Standard Climate of 23° C and 50% rel. humidity. FIXING & SUBSTRUCTURE: Impact Resitant According to DIN-18023 or EN13964 to be Fixed on CD Sections Profile framework with Screw 9Pc/Panel & Centre Distance Support of 300Mm & Centre distance of Cross Profile would be at 600Mm & Main Profile at 900Mm CD Profile is made out of GI( Sections Profile 60/27/0.6Mm-0.6MmThick x 60Mm Width x 0.27Mm height). The Main Profile is in the legth of 3000Mm & to form a section of 600mm x 1200mm. Heradesign Superfine panels to be fixed on the wall with a minimum of 200Mm void or gap with Galvanized screws of length 50Mm & Dia 4.5Mm with a backing of Mineral Wool of density 64kg/m3 density (50mm thick).Colour Of Panels : NATURAL BEIGE, Can be Painted to the desired colour (Any- RAL, NCS or StoColor Shades) using water based color by Spray method prior to installation. FIRE CLASS as per EN 13501-1:B –s1, d0. Test Certificates to be submitted. Ground Floor
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Finishing the terrece slab integrally mixed with water proofing compound in C.M. 1:3 with 12 mm thick layer including curing, finishing,using waterproofing compound as approved by Engineer-in-charge at the rate of 1 kg per bag of cement etc. complete. Ground Floor, Canteen , Sump Well
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Providing and fixing M.S. grill door 24 Kilogram/ One Square Metre of various size as per detailed drawings without hot dip coating, iron fixtures and fastenings and 3 coats of oil painting etc Ground Floor
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Providing and fixing four fold partly panelled partly glazed door with fan light of required sized as per detail drawing with Indian superior teak wood frame of size 150 mm x 100 mm, Indian superior teak wood shutter 35 mm thick consisting of styles 125 mm x 35 mm., frienge rail 125 mm x 35 mm., Lock rail of 150 mmx 35 mm and bottom rail 250 mm x 35 mm including 35 mm thick Indian superior teak wood carved panels, 6 mm thick eitched float glass with stainless steel grill (15 Kg /Sq.m.) including necessary brass fixtures and fastenings including finishing with two coats of melamine polish etc. complete. Ground Floor
Solid Core Flush door Double leaf Providing and fixing factory made solid core flush door shutters in double leaves 35mm thick,decorative type of exterior grade, as per detailed drawings, conforming to I.S.: 2202 – 1966 (Revised) including approved face veneers on both sides, without glazing and venetians including mat finish stainless steel fixtures and fastening, stoppers and finishing with french polishing etc. (including CCTW door frame)(Sample to be got approved from Ex. Engineer before use) Commercial Hard Wood shutter Ground Floor
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Solid Core Flush door Single leaf Providing and fixing factory made solid core flush door in single leaf 35 mm thick, decorative types, of exterior grade, as per detailed drawings, conforming to I.S.:2202 - 1962 (Revised) with approved face veneers on both faces with/without glazing and venetians in the positions shown on the drawings or as directed, all necessary beads, moulding and lipping, holdfasts, mat finish stainless steel fixtures fastenings , finishing with french-polish/ waxing complete. (with CCTW door frame).(Sample to be got approved from Ex.Engineer before use) Commercial Hard Wood shutter Ground Floor, Canteen
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Providing and fixing FRP (Fiber reinforced Plastic) Door with shutter 25 to 30 mm Thick having properties such as water proof resistant to termite resistant to mild acids and chemical. The thickness of FRP should be of 1.5 mm With extra reinforcement to sides, edges, recess for alluminium fixtures and fastenings and commercial types as per the approved design including alluminium fixtures and fastenings and two coats of synthetic acrylic emulsion paint etc. complete. ( Excluding door frame) (for W.C. and bath doors) Ground Floor, Canteen.
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Providing and fixing Country cut teak wood double or single leaf panelled shutters, 35 mm thick style top and freze rail 95 x 35 thick with lock and bottam rail 195 x 25 mm thick and panels without ventilator as per detailed drawing including the CCTW door frame, stainless steel fixtures and fastening and finishing the wood work with oil painting 3 coats complete. Ground Floor , Canteen.
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Providing and fixing in position U.P.V.C.(Unplasticized Poly Vinyl Chloride) having multi- chambered outer frame section (73 x 50)mm with an outer wall thickness of 2mm & steel reinforcement, multi-chambered slider frame (73x 60) mm with steel reinforcement, multi- chambered slider sash (46x 82) mm with steel reinforcement designed to give optimum strength, 5 mm thick toughened double glass with 12 mm spacer of good quality including alluminium track, Inter-locking profile, coextruded beadings, EPDM gaskets,silicon sealent,sliding handle, fixtures and fastenings (couplings, hinges) including with all required screws and nuts with all necessary U.P.V.C. sections as per the detailed drawing and as directed by Engineer-In-Charge etc. complete. Ground Floor
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Sliding Window-3 Track (2 Glass shutter + 1 flymesh)of approved make with DGU, providing and fixing of Sliding Window - 3 Track (2 Glass shutte r+ 1fly mesh).For details refer to Specifications. As directed by Engineer in charge. Ground Floor
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Providing & fixing of Casement fixed window of approved make with DGU. The extruded aluminium sections of Alloy 6063 tolerances confirming to DIN standard from approved raw material V2 / V4 as directed by Engineer in charge. Ground Floor
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Providing and fixing of factory made uPVC Sliding window & door (White Colour) complete, comprising uPVC multi-chambered frame having in-built uPVC roller track on top and uPVC sash with wall thickness of 2.3mm (+-0.2 mm), duly reinforced with G.I. section 1.5 mm, wherever required. uPVC window & door profile shall be made in India & shall conform to BS EN 12608 and other standards as mentioned below: S.No. Name of the test Test Method Specified Parameter 1 Tensile Impact Strength ISO 8256 - more than 700Kj/m2 2 Vicat Softening Temperature EN ISO – 306 Shall not be < 750C 3 Charpy Impact Strength EN ISO – 179-2 Shall not be < 20KJ/m2 4 Flexural Modulus Elasticity EN ISO – 178 Shall not be < 2200 N/mm2 5 Mean Breaking Stress for welded corner (a) For the tensile bending test EN – 514 Shall not be < 25 N/mm2 (b) For the compression bending test Shall not be < 30N/mm2 6 Heat Reversion Test IS:4985-2000 Shall not be > 2.0 % 7 Surface Spread of flame BS : 476 - Part 7 Classification 1 8 Ignitability Evaluation BS : 476 - Part 5 'P' Not easily ignitable 9 Tensile modulus ASTM D 638 Shall not be < 35 MPa 10 Shear Modulus ASTM D 732 Shall not be < 220 MPa 11 Tensile Strength EN ISO 527 Shall not be < 30 MPa All corners of frame and sash will be fusion welded. After placing 5 mm Float Annealed glass in the sash, uPVC glazing bead, interlock, EPDM / TPE gasket, brush shall be provided including touch lock and rollers & proper drainage system shall be provided. Window / Door will be fixed to the wall with 100mm long and 8mm dia. Fasteners and complete in all respect as per direction of Engineer-In-Charge. uPVC Window and Door Profiles are warranted for a period of ten (10) years against non-uniform discoloration, wrapping and rotting under general use. Ground Floor
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Providing and fixing of factory made uPVC Sliding window & door (White Colour) complete, comprising uPVC multi-chambered frame having in-built uPVC roller track on top and uPVC sash with wall thickness of 2.3mm (+-0.2 mm), duly reinforced with G.I. section 1.5 mm, wherever required. uPVC window & door profile shall be made in India & shall conform to BS EN 12608 and other standards as mentioned below: S.No. Name of the test Test Method Specified Parameter 1 Tensile Impact Strength ISO 8256 - more than 700Kj/m2 2 Vicat Softening Temperature EN ISO – 306 Shall not be < 750C 3 Charpy Impact Strength EN ISO – 179-2 Shall not be < 20KJ/m2 4 Flexural Modulus Elasticity EN ISO – 178 Shall not be < 2200 N/mm2 5 Mean Breaking Stress for welded corner (a) For the tensile bending test EN – 514 Shall not be < 25 N/mm2 (b) For the compression bending test Shall not be < 30N/mm2 6 Heat Reversion Test IS:4985-2000 Shall not be > 2.0 % 7 Surface Spread of flame BS : 476 - Part 7 Classification 1 8 Ignitability Evaluation BS : 476 - Part 5 'P' Not easily ignitable 9 Tensile modulus ASTM D 638 Shall not be < 35 MPa 10 Shear Modulus ASTM D 732 Shall not be < 220 MPa 11 Tensile Strength EN ISO 527 Shall not be < 30 MPa All corners of frame and sash will be fusion welded. After placing 5 mm Float Annealed glass in the sash, uPVC glazing bead, interlock, EPDM / TPE gasket, brush shall be provided including touch lock and rollers & proper drainage system shall be provided. Window / Door will be fixed to the wall with 100mm long and 8mm dia. Fasteners and complete in all respect as per direction of Engineer-In-Charge. uPVC Window and Door Profiles are warranted for a period of ten (10) years against non-uniform discoloration, wrapping and rotting under general use. Ground Floor
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
a) Supplying and fixing in position Aluminium four track sliding windows with outer frame made from section of over all size 122 mm x 45 mm, bottom section with drain section track weighing 1.83Kilogramper metre and top and side section of size 122x 31.75 mm weighing 1.15Kilogramper One Running Metre with shutter sections made of 18 mm x 40 mm size having average weight of 0.6Kilogramper One Running Metre (or as required size) with change in proportionate weight, with 6 mm float glass in three equal panels and alluminium coated stainless steel mosquito net in one (2/3 of opening) panel fixed with new neoprene gasket, shutters to be provided with nylon encased stainless steel rollers, necessary locks and handles complete. Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Providing and fixing in position anodised (as per IS 1868/1982) Aluminium fixed staggered ( Z Type) Ventilator with aluminium rectangular pipe 63 mm x 38.10 mm x 1.22 mm at weight 0.650 Kilogram/One Running Metre, Aluminium angle of size 15 mm x 15 mm x 1 mm,aluminium channel of 9 mm sizes, S.S.mosquito net of 304 Grade,4 mm thick float glass per detailed drawing and as directed by Engineer in charge etc.complete Ground FLoor , Canteen
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Providing and fixing in position colour Anodized Alluminium partly fixed partly louvered windows/ ventilator of various size as per detail drawings and specifications including alluminium frames 80 x 38 mm box type 5 mm. thick sheet glass louvers, clips / rubber plain P.V.C. gaskets of approved quality etc. complete. [Sample to be got approved from Executive Engineer before use.] Ground Floor
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Providing and fixing mild steel grill work for windows, ventilators etc. 20 Kilogram/ One Square Metre as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete. Ground Floor , Canteen , Sump Well , Entrance Gate.
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Providing and fixing 900mm high S.S.304 Grade Stainless steel railing with 40mm diameter and 1.5mm thick at top, 40mm diameter and 1.5mm thick vertical supports spaced at 1.5m center to center and 8mm thick toughened glass including fabricating ,fixtures, errecting , necessary welding , grinding , finishing, buffing to stainless steel pipe etc. complete. Ground Floor
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Providing and applying water proofing treatment using acrylic polymer modified cement based water proofing coating with fibre glass mesh mixing at the rate of powder to liquid (2:1) by weight covering 9 to 10 Square Metre /Kilogram with two coat using approved chemicals for masonry and concrete surface by brush covering 7 years guarantee on Stamp Papers etc. complete. Ground Floor, Canteen
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete. Ground Floor , Sump Well , Entrance Gate
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Providing and applying two coat of Polymer based external weather proof & dust proof paint of standard manufacture like Apex Ultima from Asian paints, weathershield from Dulux of approved colour to the plastered surfaces including scaffolding if necessary, cleaning and preparing the surfaceetc. for specified buildings complete.(including primer coat )(Prior specific permission of S.E. shall be obtainedbefore inclusion of this item in the estimate.) Ground Floor , Canteen, Sump Well , Compound Wall, Entrance Gate
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Providing and applying interior wall finish luster of approved make on internal wall surface as detailed below Scrapping the surface with emery paper and wipe clean wall primer with brush with mineral turpentine with brush 8 to 10% and oil 15 to 20% with roller and allowing to dry for a period 6 to 8 hours. wall putty with appropriate proportion of water allowing to dry for period 4 to 6 hours. Scrapping with Emery paper 180 and wipe clean. Applyingwall primer with brush with mineral turpentine 8 to 10% and oil 15 to 20% with roller Scrapping Emery paper 320 and wipe clean, interior wall finish luster 1st coat with brush/rubber/spray with mineral turpentine 7 to 9% and Oil with roller 19 to 21% After 8 hours of activity Applying 2nd coat or wall finish Lustre with mineral turpentine 7 to 9 % with brush and Oil with roller 19 to 21% after allowing dry for the period of 6 to 8 hours activity. (With prior approval of S.E.) Ground Floor
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Providing and fixing White Glazed Earthenware Squatting plate (Ladies Urinal) with P.V.C. flushing cistern of 5 liters capacity with fitting, inlet pipes and stop tap, brackets for fixing the cistern, 32 mm dia. P.V.C flush pipe with fittings and flushing arrangement including lead soil pipe, lead trap, soil pipe connectionup to the outside face of the wall. Ground Floor
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Providing and applying top coat exterior paint to terrace of approved make, shade and quality and one coat of primer before applying textured paint including scaffolding if necessary preparing surface by throughly cleaning of oil, grease, dirt and other material and fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) preparing as required, etc. complete. Main Building Third Floor
Canteen Ground Floor
Providing and fixing Orissa Pan of size 580x445x260 mm with approved make flush valve including trap, C.I. soil and vent pipe upto outside face of wall including 100mm dia. C.I. plug, bend and necessary pipe connection, etc complete. As directed by Engineer in charge. Ground Floor, Canteen
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Providing and fixing white european type wall-hung, Size 360mm x 360mm x 575 mm with flush valve having flow rate up to 6.0 Litr/Minute of Jaquar/Cera/Hindware /Perryware or equivalent make including PVC soil pipe, vent pipe upto outside face of wall, 100mm dia PVC plug bend inlet pipe all fittings,cutting & making good walls, floors etc as directed by Engineer in charge.( Make shall conform to manufacturer's Green product and shall got approved from the Engineer In Charge.) Ground Floor
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Providing and fixing stainless steel sink of size 600 x 510 x 200 mm incluidng coupling, outlet pipe, elbow and other necessary fitting, finishing etc. complete. Ground Floor , Canteen
Providing and fixing oval type under counter wash hand basin of 16 inch x 22 inch size and of special colour shade having telephonic black / coloured granite of 180 mm thick stone black kadappa framework including chromium plated coupling bottle - Trap using CERA company or equivalent oval typa wash basin model no 3448 as per detailed drawing or as directed by engg incharge etc complete. (Counter size 1.20 m x 0.60 m ) Ground Floor , Canteen.
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Providing and fixing 10 cm PVC nahani trap with grating etc. complete. Ground Floor , Canteen
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Providing and fixing white glazed earthenware lipped flat back/corner type Urinal with PVC 5 liters flushing cistern with fittings, inlet pipe with stop tap, brackets for fixing the cistern, 32 mm diameter P.V.C. flush pipe with fitting including lead soil pipe, lead trap and soil pipe connection up to the outside face of wall. Ground Floor
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Providing and fixing on walls/ceiling/floor 20 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Ground Floor , Canteen
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Providing and fixing on walls/ceiling/floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Ground Floor , Canteen
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Providing and fixing on walls/ceiling/floor 40 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Ground Floor .
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Providing and fixing on walls/ceiling/floor 50 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Ground Floor .
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Providing and laying in trenches 50mm dai. CPVC pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Ground Floor
Providing and fixing C.P. BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete. Ground Floor , Canteen
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Providing and fixing screw down for 40 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete. Ground Floor
Providing and fixing screw down for 50 mm dia. wheeled stop tap of brass including necessary sockets/ union nut complete. Ground Floor
Main Building Third Floor
Providing and fixing screw down for 25 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete Ground Floor , Canteen
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Providing and fixing 75 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete. Ground Floor , Canteen.
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Providing and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete. Ground Floor
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Providing and fixing P.V.C. Rain water pipes of 160mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and One Number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. Ground Floor , Canteen.
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Providing and constructing Brick Masonry Inspection Chamber 90cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W.pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with R.C.C. Cover medium duty 140Kilogramwith frame etc complete. Main Building
Providing and constructing Brick Masonry Inspection Chamber 60cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with R.C.C. Cover medium duty 140Kilogramwith frame etc complete. Main Building , Canteen
Providing and fixing 15cm x 10cm salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap. Main Building , Canteen
Providing and fixing in position UPVC ultra violet stabilized 110 mm outer diameter cowl dome confirming to I.S.-4985 including making joints with solvent cement etc. complete . Main Building , Canteen
Providing and laying cement concrete flooring 40 mm thick with M15 cement concrete laid to proper level and slope in alternate bays including compaction, filling joints, marking lines to give the appearance of tiles of 30 cm x 30 cm or other size laid diagonally /square etc finishing smooth (with extra cement) in any colour as directed and curing etc. complete.with Crushed sand VSI Grade Ground Floor
Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. Ground Floor
Providing and applying plastic emulsion paint of approved quality, colour and shade to old and new surfaces in two coats including scaffolding, preparing the surface. (including the primer coat)etc. complete. Ground Floor, Canteen , Sump Well, Entrance Gate .
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Providing and fixing 450mm x 550mm size superior type Belgium mirror with 16mm dia. nickel plated towel rod etc. complete. Ground Floor , Canteen
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Providing and fixing chromium plated towel rod 16 mm dia and 75 cm. in length including all accessories complete. Ground Floor , Canteen
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Providing soak pit of size 120cm x 120cm x 120cm including excavating and filling with brick-bats. Main Building , Canteen
Providing structural steel work in hollow section of various thickness and sizes in square, rectanular and round shape from 25mm to 450mm section as per IS 4923 YST 310 Grade produced from iron ore and blast furnace route etc. as per detailed designs and drawing or as directed including cutting, fabricating, hoisting, erecting, fixing in position, making riveted/bolted/ welded connections and painting complete.
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Supply and Installation of translucent roof with DPI Flux standing seam multicell polycarbonate panel system. The system with complete assembly of co extruded UV protected multicell panels incorporated into a complete system. Co-extruded UV protected polycarbonate panel system of min 12 mm thick of 900 mm (min.) width with angular daylighting concept. Panels shall have minimum six layers with truss bridge design for higher flexibility & strength. Panels with all fixing accessories to ensure best performance for wind uplift, vibration, oil canning and visual appearance. Panels shall be manufactured with vertical standing seam at both sides of the panel. Panels shall be fixed on Purlin with snap on connectors with double tooth grip lock locking mechanism and will be secured on MS structure (will be paid Separately) with 3 One Numbers self-drilling screws & trapezoid SS fasteners holding the base of the standing seam offering best stability having a pull-out load of min. 7000N (7KN) tested as per ISO 6892:1998 and IS 1608: 2005, as per design requirement. Panels must satisfy Dart drop impact test as per IS 14443-97 shall show no sign of breakage on Polycarbonate sheets which have been exposed to UV for a min. of 500 Hours as per ASTM G 155. Panels shall not have Yellowness Index as per ASTM D 1925 of 15 units when tested on a sample exposed to UV for 500 Hours as per ASTM G 155. U value shall not be more than 1.6 W/m2K as per EN ISO 10077-2:2018. Panel shall be with additional End cap/Aluminium U/F profile/ Glazing Bar for ends as required. Panel shall be fixed over MS structural steel/MS purlin (paid separately) conforming to the detail technical specifications as per approved architectural drawings. Trained and factory authorized labour with supervision to complete the entire panel installation as per drawing & direction of the engineering in charge. Colour: As per Approval. Approved Make: FLUX by DPI Daylighting or approved equivalent The 12mm thick panels shall be used for a roofing height of upto 15 mtrs. Third floor
RWH - Recharge Pit Providing and constructing recharge pit of 2.0m deep and 1.0m dia of pre-cast RCC rings with 6.5" dia x 25m deep borewell at the floor of recharge pit including installation of combination of solid/perforated PVC casing pipe wrapped around with netlon mesh including 300mm thick sidefilling around outside of RCC rings (annular space) with 40mm size boulders including filling of recharge pit up to 0.5m depth with 25-75mm clean washed gravels from bottom up followed by 0.5m depth of 10- 25mm of clean washed stones followed by 0.5m of washed river fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) including netlon mesh between each gravel/fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) media layer including covering with RCC slab, manhole frame & cover, PVC rungs, PVC end?caps, fittings etc. including arrangement for inlet & outlet pipe excavation & backfilling as shown in the drawing.The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All material should be of approved make. All works complete as per the drawing, technical specification and direction of the Engineer in charge.
Providing and laying concrete pipes of I.S.NP. class of 225mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete
Providing and laying concrete pipes of I.S.NP. class of 300mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete
Providing and fixing interior wall to wall expansion joint cover model W90 for 50 mm gap size, this surface mounted aluminium cover is designed for interior application where low maintenance is desirable. This model is made using Aluminium alloy 6063 and temper T5/T6. This cover is installed using stailness steel clip in the rear which helps the movement to + 10 mm. Ground Floor
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Providing and fixing of external wall to wall cover model ASM 200X for 50 mm gap size,this surface-mounted metal wall cover is designed for exterior applications where low maintenance or tamper-resistant applications are desired. The free-floating aluminum center plate spans the joint and slides over the surface of the wall to allow required movement.EPDM vapor barrier to protect the joint with water. This profile is extruded aluminum with ASTM B 221, Alloy 6063-T5. This profile has been tested under Architectural Testing Agency ( an Intertek Company) for the movement performance. The minimum opening of the profile is 10mm ( -40mm) and the maximum openeing of the profile is 76mm (+26mm) which is more than ±50% movement. Ground Floor
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Main Building First Floor
Main Building Second Floor
Providing and Fixing of external Roof cover model RJT 200 for 50 mm gap size, Aluminium roof cover comprised of extruded alumunium components, Injection molded turnbar, duroflex gaskets and EPDM vapor barrier.This profile is extruded aluminum with ASTM B 221, Alloy 6063-T5. This profile has been tested under Architectural Testing Agency ( an Intertek Company) for the movement performance. The minimum opening of the profile is 3mm ( -47mm) and the maximum openeing of the profile is 92mm (+42mm) which is more than ±50% movement. Third Floor
Providing expansion joints with 25mm thick bituminous pad as per detailed drawings etc. complete. Ground Floor
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Structural Glazing (Unit - Per One Square Metre) Designing, providing fabrication, supplying & fixing in position structural glazing to external face of the building straight in plan consisting of main panel work of vertical & horizontal made out of specially designed extruded 38 x 83mm powder coated alluminium section, anchor to RCC element through adequately designed powder coated MS clamps, bracket using 5mm thick one way reflective make Saint Gobain Glass (Blue/Bronze/Green Reflective Glass) & weather silicon sealant of approved grade (Direct Sticking) Material used Mullion Section: 63 x 83mm Transform Section: 63mm x 38mm Spacer tape, Silicon sealant SSG 4000 ULTRA GLAZED/995 Dow Coring, Silprooof / 789, Glass equivalent 5.00mm thick one way reflective in Blue/ Any Colour (Saint Gobain) The joints shall be properly sealed with approved silicon sealant to make the joints watertight and weather proof including fixing over alluminium frame using mechanical fasteners such as alluminium cleats and fasteners, specially designed frame work with vertical and horizontal members of extruded alluminium section which shall be made of alloy 6063 T6, as approved by the Engineer in charge (as per Approved drawings) The work shall be complete as per specification and direction of Engineer in charge Including all other taxes excluding GST.etc complete MS fabrication. Ground Floor
Main Building First Floor
Main Building Second Floor
Supplying and fixing of 6mm thick Exterior Compact Laminate or High Pressure Laminate of approved colour by approving authority with UV resistant Decorative colour paper on both side typically made out of multiple layers of craft papers and then impregnated with thermosetting phenolic resins, on top of it melamine treated barrier paper and decorative paper and wear layer on both the sides saturated with melamine resins and then covered with UV resistant acrylic resin layer which makes it extremely durable and weather resistant compressed together on extremely high pressure and hardened with electron beam curing to get the total desired thickness of 6mm matching European standard specification as per EN 438 -part 6, protected with 60 Micron protective peel-off film on both side which in no case leave any adhesive mark over the panel surface after it is peeled off. Fixing of the same to be done on a supporting frame of 50 mm X 5 mm X 3 mm powder coated aluminium box section to be spaced horizontally and vertically in 600mm X 600mm grid and fixed to building structure as per design through 50mmX50mmX mm 5 mm MS angle bracket prefixed to masonry slab or columns with Hilti make anchor fastener along with all related hardware and fixtures. The panel should then be fixed on the Aluminium section with the help of pure polyester exterior grade colour coating rivets as per architectural drawings or as directed by Engineer-in-charge. Each panel should be riveted on substructure maintaining a gap of 6mm on all the sides between each Panel for Air circulation and expansion and contraction as per installation specifications provided by the manufacturer. The cost shall include all expenses related to storage, material handling, lifting, freight, labour, scaffolding etc as directed by Engineer-in-charge. (Prior permission of S.E. is necessary before inclusion of this item in estimate) Ground FLoor
Main Building First Floor
Main Building Second Floor
Providing and Fixing Processed Stone Cladding on wall surface/ plywood surface. RCC pardi/ Wall and all type of Interior, Exterior Compound wall and Gate etc. of cladding processed stone with material of Processed clay, Wooden chips, Silica sand, Cement, GFRC admixtures, Colour pigments, Fiber up to thick of 230 mm/ 25 mm including scaffolding, fixing of screw, etc. (As directed by Engineer in Charge) Ground Floor
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Providing and fixing wall hung white wash basin of size 550 x 400 x 195 mm with pillar cock having flow rate up to 6.0 Litr/Minute,C.P.Angular stop cock long thread of Jaquar/Cera/Hindware /Perryware or equivalent make, including SS bottal trap of approved make etc complete as directed by Engineer in charge.( Make shall conform to manufacturer's Green product and shall got approved from the Engineer In Charge.) Ground Floor
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Providing and fixing 90 cm x 60 cm Granite plate engraving 10 cm. Height letter, figures including painting the lefters/figures with approved colour and shade complete
Providing & Fixing mat finish stainless steel lettering of various heights as directed by Engineer in-charge including material, labour, cleaning etc. complete. 1) Upto height of 30 cm.
2) From 30 to 45 cm. height
1) Upto height of 30 cm
2) From 30 to 45 cm height
Providing groove to required size at specified location as directed by Engineer, at junction of brick masonry wall and R.C.C beams or Column, at junction of composite masonry, including scaffolding, finishing, curing etc. complete. Ground Floor, Compound Wall
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Directional signage Design, supply, fabrication and fixing acrylic multilingual Braille (raised dots) directional signboards of size 6" x 9" designed as per accessibility standards and having 4mm thick acrylic base plate with Upper Case San Serif words made of white acrylic non glare cut out letters of height 15mm raised not less than 0.8mm above base plate and the equivalent word written in Hindi with Devnagri non glare acrylic letters of height 15mm raised not less than 0.8mm above base plate and having a non glare acrylic cut arrow pointing in the required direction. Each signboard to be fixed as per manufacturers specifications on the wall at the approved location and at a height of 1200mm from FFL and as per the directions by the engineer in charge. Ground Floor
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Providing and fixing in position after hoisting, precast 1:2 cement mortar reinforced jali 80 mm thick with 3 mm diameter mild steel bar reinforcement, of approved design on both sides, fixing in cement mortar 1:3 and curing etc .complete. Ground Floor
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Providing and fixing mild steel grill gate as per the detailed drawing including hinges, locking arrangements and painting in three coats of oil paint of approved colour and shade etc. complete.(weight 18 Kilogram. to 20 Kilogram. Per Sq.m.) Spec.One Number: As directed by Engineer- in-charge. Ground Floor
Providing and laying machine cut machine Polished Kota stone flooring 25mm to 30mm thick and required width in plain/ diamond pattern on bed of 1:6 C. M. including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete. Main Building , Sump Well , Entrance Gate
Providing and fixing H.D.P container one piece moulded water tank made out of low density polythyler and built corrugation including of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow of all tanks capacity above 1000 to 20,000 litres. Third Floor
Providing and fixing Braille indicators for handrails of the approved design and make having Braille dots raised 0.5mm above base plate, to be installed at the specified locations as per the directions of the engineer in charge. Ground Floor
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Supply & Fixing of Rectified Porcelain Stoneware Tiles for Ventilated Facades of Specified size as per specification/ site drawings having 6 mm and 9 mm thickness with factory made Kerfs (grooves) as per need and size 600/1200 and 800/1600. The Rectified Porcelain Stoneware Tiles shall possess properties having Water absorption < 0.5% Bending Strength > 40 N/mm2 and are resistant to : UV Light, chemicals, smog, thermal shocks & bacteria. The facade will be made from Nexion Rectified Porcelain Stoneware Tiles (Sintered Compact Surfaces) specified as per ISO 13006 : Annex G- EN 14411 : Annex G : Dry Pressed Ceramic Tiles and all the tests carried out by Italian labs accredited according to ISO/ IEC 17025 : 2005. The Terramilano Fixing sub structure will confirm to Norme Tec niche per le Costruzioni NTC/8 (Technical Standard for construction) guidelines for construction in Italy, Eurocode 0 " Information on the method of semi-probabilistic limit states and safety factor " Euro coad 1 " Determination and calculation of actions on structure " Euro 9 " Project aluminum structures " UNI 11018 and ETAG 034 The Substructure will consists of Upright extruded aluminum profile TruSt80, alloy 6060 T5 thickness equal to 1.5 to 2 mm and dimension 80 x 110 mm, inter axis 80 cm of Length 3660 mm, 8085 Aluminum box Section of 1 x 3 inch,1x2inch and 1x 5 inch of length 3660 mm and thickness 1.5 to 2 mm as per need. Brackets St80 galvanized steel and aluminum of 80 mm x 60 mm, aluminum L bracket size 1.5 x 1.5 inch and 1 x 2.5 inch thickness 3 mm that allow to anchor the vertical stand to the Building, 9 mm/6mm S10 Hooks Harmonic Stainless Steel AISI 304 which supports the weight of the Tiles; Bossong/Hilti Mechanical Fasteners and Nylon Anchor Fastner; and Structural Sealant of 3M for Ventilated Facade. Packing of Edges and corner with window seal with ACP of appoved make for water Proofing and alteration. Inclusive of scaffolding and fixing. The installation method differ according to the structure of building and design. For EXTERNAL AND INTERNAL CLADDING OF STRUCTURE. with prior approval of concerned Superitending Engineer. Ground Floor
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Providing and fixing 15 mm thick eco-friendly densified edge calcium silicate false ceiling of approved texture of size 595mm x 595mm in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sections (galvanising at @12 gm/sq.m including both sides) consisting of main T runner suitably spaced at joints to get required length and size 24X38mm. made from 0.33mm thick(minimum ) sheet, spaced 1200mm center to center and cross T of size 24X28mm made of 0.33mm thick(minimum ) sheet to be interlocked at the middle of the 1200x600 mm panel to form the grid of size 600x600mm resting on periphery walls/partitions on a perimeter wall angle precoated steel of size 24x24x3000 made of 0.4 mm thick (minimum) sheet with the help of all plugs at 450mm and laying 15 mm thick densified edges calcium silicate ceiling tiles of approved texture (spintone/cosmos/hexa) in the grid, including light fittings , fixtures , smoke detectors etc., wherever required. Main T runners suspended from ceiling with using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling using 12.5mm dia. And 50mm long dash fasteners, 4mm G.I. adjustable rods with galvanized steel levels clips of size 85x30x0.8mm, spaced at 1200mm center to center along main T bottom exposed with 24mm of all T-sections shall be prepainted with polyester baked paint, for all heights, as per specifications, drawings etc. complete. Ground FLoor
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Providing and fixing false ceiling with eco-friendly light-weight calcium silicate tiles of spintone surface texture aerolite make or equivalent of size 595mm x 595mm having 15mm thick densified micro look edge and 100% humidity resistance incombustible as per BS 46part IV and thermal conductivity 0.043 w/m 0 KC and NRC 0.50 placed in true horizontal level suspended grid of size 600x600mm made from hot dipped G.I. steel sections ion silhouette profile, rotary stitched double webbed white with 6mm reveal profile (white/black), wherein, main T runner of size 42mmx14mm between main tee 600mm center-tocenter and secondary cross T of size 33x14x0.43mm thick of length 600mm long spaced inter-locked at middle of the first crossed T in each panel to form grid of 1200mmx600mm resting on periphery wall Profile wall section 19mm (7+7) x 19mmx0.40thicknesses and laying false ceiling for services like diffusers grills including cutting, making opening for light fittings, fixtures, , smoke detectors etc., wherever required. Main T runners suspended from ceiling with using G.I. soffit cleats of size 25x35x1.6 mm of required length fixed to the ceiling with 6mm dia and 50mm long dash fastener, 4mm dia G.I. adjustable rods with powder- coated/good quality G.I. level adjustment clips of 35x35x0.8mm spaced @1200, center-to- center along main T all complete at all heights as per the specifications, drawings Ground Floor
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Providing and fixing ISI marked double swing flush door shutters conforming to IS :2202 (Part I) Non-decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 mm thick including ISI marked Stainless Steel L- hinges with necessary screws Fittings & Fixtures per leaf SS kick plates on both sides of the door of 300mm height Heavy Duty satin finish butt SS Hinges (100mm x 75mm x 3mm in size) -4 One Number. SS finished lever handle with mortise lock- 1 One Number Floor spring- 1 One Number 100mm x 100mm safety glass at the specified location. Ground Floor
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Providing and laying in place 300mm x 300mm x 9.8mm vitrified tactile warning and directional tiles of the approved brand, make and colour inside the buildings at in all corridors and lobbies, level differences etc. as per accessibility standards and as per the installation instructions prescribed by the manufacturer including zarri making wherever required and finishing including grouting the joints with white cement with matching pigments etc. up to the satisfaction of the engineer in charge complete. Ground Floor
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Grab bars-Providing SS grab bars set for accessible toilets comprising of 4 One Number. Grab bars as specified below.(1 One Number. wing grab bar + 1 One Number. L shaped grab bar + 2 One Number. straight grab bars = 1 typical set) 27a) Swing grab bar (1 One Number) Providing a S.S. 304 SWING HANDICAP GRAB BAR - 700 mm and of DIA: 32MM and thickness 1.5mm of the roved brand and make. 27b) L Shaped grab bar (1 One Number) Providing S.S. 304 L SHAPED DISABLED GRAB BAR of IZE-600MM (H) X 600MM (D) and 32MM DIA. and thickness mm of the approved brand and make. 27c) Straight grab bar (2 One Number) Providing S.STEEL 304 GRAB RAIL (600 MM),32MM DIA. and thickness 1.5mm of the approved brand and make. Ground Floor
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Providing waterproofing in W.C. and bath including brick bat coba in all position including providing and laying 12mm bedding in cement mortor 1:3 on vergin concrete slab with waterproofing compound @ 1Kilogram/per bag of cement laying brick bat coba of required thickness in cm 1:5 with waterproofing compound 1 Kilogram/bag of cement grouting and finishing the top layer with 20mm thick brick bedding in cm mortor 1:3 with waterproofing compound 1 Kilogram/per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years' guarantee on requisite stamp paper including curing etc. complete. Ground Floor , Canteen.
Main Building First Floor
Main Building Second Floor
Main Building Third Floor
Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.M.1:3 admixed with approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1Kilogramper bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete. Third Floor
Providing and laying vitrified mirror / glossy finish tiles decorative type having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete. Canteen
Providing and laying vitrified mirror / glossy finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete. Canteen
Providing and laying Antiskid Ceramic tiles of approved quality of size 30 cm x 30 cm and confirming to IS 15622-2006 (Group-B IIA) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete. Canteen
Providing and laying ceramic tiles having size 30 cm. x 45 cm. confirming to corresponding I.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete. Canteen
Providing and preparing kitchen otta up to 75 cm width,made up from 30 mm thick and 75 cm high vertical support for kadppa at 1 m. c/c of 25 mm thick both side polished kadappa middle shelf and bottom of 20 mm thick one side polished kadappa with facia patti of 20 x 50 mm kadappa including all material labour cutting fixing with cement mortar and araldite curing polished and cleaning etc. complete. Canteen
Providing and fixing in position. (as per I.S.1868 / 1982) Aluminium sliding window of two tracks with rectangular pipe having overall dimension 63.50 x 38.10 x 1.02 mm at weight 0.547 Kilogram/One Running Metre. and window frame bottom track section 61.85 x 31.75 x 1.20 mm at weight 0.695 Kilogram/One Running Metre. Top and side track section 61.85 x 31.75 x 1.30 mm at weight 0.659 Kilogram/One Running Metre. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram/One Running Metre. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 Kilogram/One Running Metre. And handle section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/One Running Metre. and top section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. As per detailed drawings and as directed by Engineer in charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass with all required screws and nuts etc, complete. With colour Anodising with box . Canteen
Providing and laying in situ /Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering formwork, laying/pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with concrete Batch mix plant (Pan mixer) etc. complete. With 70% natural sand and 30% Crushed Sand VSI Grade. Sump Well , Parking Shade , Compound Wall, Entrance Gate , Flag Post
Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with concrete Batch mix plant (Pan mixer) etc. complete. With 70% natural sand and 30% Crushed Sand VSI Grade.
Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite/quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with concrete Batch mix plant (Pan mixer) etc. complete. With 70% natural sand and 30% Crushed Sand VSI Grade.
Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with concrete Batch mix plant (Pan mixer) etc. complete. With 70% natural sand and 30% Crushed Sand VSI Grade.
Providing and laying Cast in situ/Ready Mixcement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with concrete Batch mix plant (Pan mixer) etc. complete. With 70% natural sand and 30% Crushed Sand VSI Grade.
Providing and laying Cast in situ/Ready Mix cement concrete in M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting , curing , finishing and rougheningthem if special finish is to be provided and curing complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with concrete Batch mix plant (Pan mixer) etc. complete. With 70% natural sand and 30% Crushed Sand VSI Grade.
Providing and laying machine cut machine polished machine cut Kota stone slabs 20 to 25 mm thick for treads and risers of steps and staircases, with rounded One Numbering for the treads on a bed of 1:4 cement mortar including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete.
Providing and fixing factory made solid core flush door shutters in single leaves 35mm thick,decorative type of exterior grade, as per detailed drawings, conforming to I.S.: 2202 – 1966 (Revised) including approved face veneers on both sides, without glazing and venetians including mat finish stainless steel fixtures and fastening, stoppers and finishing with french polishing etc. (Including door frame)(Sample to be got approved from Ex. Engineer before use) Commercial Hard Wood shutter including pressed steel door box frame of M.S. sheet made of 18 guage thick of required section with rebate of 10 mm for required thickness of shutters and tie rod of 12 mm square bar at bottom as per specifications with or without ventilators including holdfasts, hinges welded to the frame, filling in box frame in C.M. 1:10 and finishing with 2 coats of oil painting etc. complete.
Providing and fixing in position. (as per I.S.1868 / 1982) Aluminium sliding window of two tracks with rectangular pipe having overall dimension 63.50 x 38.10 x 1.02 mm at weight 0.547 Kilogram/One Running Metre. and window frame bottom track section 61.85 x 31.75 x 1.20 mm at weight 0.695 Kilogram/One Running Metre. Top and side track section 61.85 x 31.75 x 1.30 mm at weight 0.659 Kilogram/One Running Metre. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram/One Running Metre. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 Kilogram/Running metre. And handle section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/One Running Metre. and top section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. As per detailed drawings and as directed by Engineer in charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass with all required screws and nuts etc, complete. With colour Anodising without box
Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete.
Providing and applying a base coat comprising of 1KilogramPolydee-MC and 1Kilogram fresh cement after wetting the surface followed by drying the surface for 2 days, apply primer coat of TP-40 and after drying, applying Polydee-11 two component (mixing ratio 2 A : 1 B) ) Antibacterial food grade coating inside drinking water tank in two coats with time interval of minimum 8 hrs. covering 7 years guarantee on Court Fee Stamp Paper of Rs. 100/- etc. complete.
Boring/drilling bore well of 300 mm dia for casing/strainer pipe, by suitable method prescribed in IS:2800 (partI) ,including collecting samples from different strata, preparing and submitting strata chart/borelog, including hire & running charges of all equipments, tools, plants & machinery required for the job ,all complete as per direction of Engineer in charge, upto 90m depth below ground level
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well screen pipes with ribs of 100 mm dia, conforming to IS:12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per the direction of Engineer in charge.
Preparing instant lawn ;-Excavating the ground to a required depth of 20cm,removing & conveying unwanted stuff to a required distance as directrd filling fresh garden soil /silt & manure in excavated area in a 3:1 propartion to na height of 20cms, mixing garden soil and manure thoroughly well, levelling,watering on previous night. planting required variety of lawn grass as directed and maintaining till well established by watering,weeding, cliping ,rolling ,etc complete.
preparing Edging or Border:- Excavating the ground to a required depth of 20cms, in the required area; removing and conveying unwanted stuff, rubbish to the required distance as directed.filling the excavated part with fresh soil and manure in 3:1 proportion to a required height to 20 cms,mixing, levelling ,watering the same. planting rooted edging/border plants at distance of 20 cms, apart watering ,weeding, stirring of the soil, replacing casualties,pruning if necessary ets,complete.
Preparing flower Bed :-Excavating the ground to the required depth of 30 cms, removing and conveying umwanted stuff to a required distance as directrd, fillimg fresh garden soil &manure in excavated area in 3:1 proportion to a required height of 30 cms, Mixing garden soil and manure thoroughly well,levelling ,watering,on previous night.Planting seedling of required annuals 25cms.apart Maintaining till well established by watering weeding,stirring replacing of casualties ets,complete.
Preparing Shrubbery :-Excavating the ground to required depth of 30cms ,removing and conveying unwanted stuf to a required distance as directed .Filling fresh garden soil & manure in excavated area in 3:1 Proporting to a hight of 30cms,mixing garden soil &manure thoroughly well, leveling ,wateriong on provious night .planting well- devloped shrubs plant 0.5 Mtrs. Apart as directrd and maintaining till well establised by watering,weding, stirring, replacing casualties ets.complete.
Rose Plant:- Excavating pit with size 0.3*0.3*0.3m. removing and conveying unwanted stuff to a required distance as directed .filling the pit with fresh garden soil and manure in 3:1 proportion to a height of 0.3 m. mixing the soil &manure thoroughly well ,levelling watering on provious night. Planting 40 to 50 cms. Height healthy plant by watering ,weeding ,stirring ,prunning, replacing the casualties ets. Complete.
Mogra plant / Creepers /Climbers :- Excavation pit with size 0.3m*0.3m *0.3m, removing and conveying unwanted stuff to a required distance as directed .filling the oit with approved excavated material upto a height of 0.15 mtr.and remaining height of 0.15 mtr. With fresh garden soil and manure in 3:1 proportion .mixing soil and manure thoroughly well levelling, watering, on previous night. Planting one or two year old healthy plant as per specifications maintaining till well established by watering ,weeding, prunning stirring replacing casualties, etc complete.
Planting Large flowering /shady tree (Ht.1 mtr):-Digging pit with size 0.9*0.9 *0.9, removing and conveying unwanted stuff to a required distance as directed. Filling the pit with approved excavated material upto a height of 0.30m. And remaining height of 0.60m. With fresh garden soil& manure in 3:1 proportion. Mixing soil & manure thoroughly well, leveling , as directed, watering previous night, planting one to two year old minimum 1 Mtr height, healthy tree sapling as pea specifications. Maintaining till well established by watering, weeding , stirring of soil replacing of casualties etc. complete.
Planting Large flowering /shady tree (Ht.2 mtr):- Digging pit with size 0.9*0.9 *0.9, removing and conveying unwanted stuff to a required distance as directed. Filling the pit with approved excavated material upto a height of 0.30m. And remaining height of 0.60m. With fresh garden soil& manure in 3:1 proportion. Mixing soil & manure thoroughly well, leveling , as directed, watering previous night, planting two to three year old minimum 2.0 Mtr. height, healthy tree sapling as pea specifications. Maintaining till well established by watering, weeding , stirring of soil replacing of casualties etc. complete.
Compacting the sub grade/gravel/oversize metal (200 mm loose) layers for all width with Vibratory roller having weight 8 to 10 MT. including necessary, labour, materials and artificial watering complete.
Providing and fixing heavy duty inter locking concrete Rubber mould glossy paving blocks of 80 mm thickness of having a strength of 400 Kilogram/Sq.cm. of approved quality and shape on a bed of crushed sand of 25 to 30 mm thick including skirting joints and cleaning etc. complete. (using 100% crushed sand)
Providing and laying Cast in situ/Ready Mix cement concrete in M20 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with concrete Batch mix plant (Pan mixer) etc. complete. With 70% natural sand And 30% Crushed sand VSI Grade
Providing, fabricating and erecting at site of work the tubular steel structure (shed) as per standard design and specifications having various spans in between trusses and in multiples of standard length of bays as specified as per standard specifications, inclusive of cost of steel tubular trusses, tubular columns purlins, tie runners, foundation bolts, base plates, nuts and bolts, welding wherever required etc. as per detailed drawing inclusive of one coat of anticorrosive paint and two coats of oil painting of approved quality and shade etc. complete. Spec. One Number : As directed by Engineer-in-charge.
Providing and fixing colour coated Zincalume ( R ) AZ150 ( min 150 gms/sq.mt. total on each side ) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness ( BMT ) (0.5 mm TCT ), Hi-strength steel with min.550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55% aluminium 43.4% zinc 1.6% silicon) with COLORBOND ( R ) steel quality super durable polyester paint coat ( with inorganic pigment). The paint shall have a total coating thickness of nominal 35 um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nom. 950- 1050 mm effective cover width and nominal 25-30 mm deep ribs with subtle square fluting in the five pan at nominal 180-250 mm center- to-center. The end rib shall be designed for anti-capillary groove. and return leg. The feed material should have coil manufacturers product details marked a regular interval. Including fasteners with min. fastened with min. 25 um Zinc-Tin alloy coated, Hex head, self-drilling screw etc. complete. (weight of profile 4.52 Kilogram/ One Square Metre)
Providing and laying Cast in situ/Ready Mix cement concrete in M15 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Sepc. No. Bd.E.4 Page No. 289 and B7, Page No. 38 .SSR I.No. 24.08, Sr.No. 828, P.131
Providing and erecting 1.5 metre high wire fencing with seven rows of barbed wire supported on M.S.Angles ( 50mm x 50mm x 6mm) at 2.5 Metres, Center to center including excavating pits for foundqtion, fixing post in cement cocnrete 1:4:8 of size 45 x 45 x 45 cm fastening the wire and painting the M.S.Angles with one coat of red lead primer and two coats of painting etc.complete. Spec No. Bd.W.3 Page Number583. SSR I.No.44.09, Sr.No.1510 P.No.213
Providing structural steel work in hollow section of various thickness and sizes in square, rectanular and round shape from 25mm to 450mm section as per IS 4923 YST 310 Grade produced from iron ore and blast furnace route etc. as per detailed designs and drawing or as directed including cutting, fabricating, hoisting, erecting, fixing in position, making riveted/bolted/ welded connections and painting complete.
Providing and fixing mild steel grill railing 20 Kilogram/sq.m with teak wood hand rail of size 75mm x 60 mm.and sill of 75mm.x 25 mm.and newel posts for staircases, including fabricating, fix-tures, erecting, painting the grill work with one coat of anti?corrosive paint and two coats of oil painting with approved colour and polishing the sill, hand rail and the newel post with french polish.
Supply, fixing and installation of 4mm thick Aluminium Composite Panel (ACP) of approved colour for external cladding in combination of solid and metallic colours, including all necessary Framework, support and complete weather sealing as per architectural drawing. The Aluminium Composite Panel (ACP) should be made out of thermoplastic core of low-density polyethylene LDPE (100% virgin mix), sandwiched between two aluminium sheets of ALLOY GRADE- 5000 series, each not less than 0.50 mm thick, total thickness of aluminium composite panels not to be less than 4 mm, the exposed surface thereof shall have Stove lacquered finishing coat not less than (26 + - 2) micron (containing minimum 70% kynar 500 based PVDF) of colour and shade as per architectural design. The inside surface (facing the building exterior surface)shall have polyster based powder coating not less than 25 Micron with protective peel-off foil on the exterior face (peel off film will in no case leave any adhesive mark over the composite panel surface after it is peeled off). The supporting framework shall be made out of 50 mm X25mm X 3mm thick Aluminium section to be spaced horizontally and vertically for fixing of panel of size 900 mm X 1200 mm and fixed to the building structure as per design through 50mm X50mm X5 mm MS angle clamps prefixed to masonry or slab, columns with Hilti make anchor fastener screws. The fixing of panel to be done with the help of VHB tapes and screws and all the sealing of joints to be done with weather sealent Silicon as directed by Engineer-in-charge. (Prior permission of S.E. is necessary before inclusion of this item in estimate)
Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in foundations and plinth of inner walls/ in plinth external walls including bailing out water manually, striking joints on unexposed faces, raking out joints on exposed faces and watering etc. Complete. Spec. No. Bd.G. 1 Page Number 313. SSR I.No.27.01, Sr.No.887 P.No.144
Providing internal cement plaster 20mm thick in Single coats in cement mortar 1:5 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete Spec. No. : Bd.L.4 Page No. 368. SSR I.No.32.06, Sr.No.958, P.No.153
Providing and applying 2 coats of 100% Pure acrylic low VOC and APEO & HCHO free water based paint of approved colour that belongs to class 1 flame spread resistance of approved make Paint should provide durable and long lasting silk finish with a high crack tolerance of upto 1mm. Paint should have an oustanding washability with high resistance to wide range of bacteria and fungus. Paint has to be applied on smooth and uniform surface prepared by an acrylic copolymer low VOC & Odour putty. This surface should be primed with water based low VOC Primer. The work activity should cover all aspects of applying paints from surface preparation as directed by Engineer in charge. Spec. No. : As directed by Engineer in charge. SSR I.No.48.13, Sr.No.1613, P.No.225 (SSR 2020-21 GREEN BUILDING)
Providing and applying two coats of synthetic enamel paint of approved colour to new /old structural steel work and wood work in buildings, including scaffolding if necessary, cleaning and preparing the surface (excluding primer coat) etc. complete. Spec. No. Bd.0.5 Page No. 405..SSR I.No.35.07, Sr.No.1075 P.No.164
Providing and Fixing mat finish stainless steel (of 302 grade ) railing with top pipe of 50 mm dia. and vertical pipe of 38 mm dia at 0.60 m c/c or as required and horizontal pipes of 25 mm dia in three rows, all pipes of 2 mm thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 mm dia above newel post of 75 mm diameter etc. complete (Prior approval of sample and brand by Ex.Engineer is necessary before use Spec No.:As directed by Engineer Incharge.SSR I.No.40.08, Sr.No.1296 P.No.192
Excavation for roadway in earth, soil of all sorts, sand, gravel or soft murum including dressing section to the required grade, camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50m. and spreading for embankment or stacking as directed. By Manual Means
Providing granular sub-base (drainage layer) by coarse graded materials, confirming to grading-II of Table 400-2 of MORT & H. in 50:30:20 proportion of 40 mm, 20 mm crusher broken metal and sand respectively, spreading on prepared surface, mixing by mix in place method at OMC and compacting to achieve the desired density etc. complete asper Clause 401 for Grading-II material etc.complete.
Providing, Laying, Spreading and compacting stone aggregates of specific sizes to Water Bound Macadam specification including spreading in uniform thickness, hand packing, rolling with 3-wheeled steel/vibratory roller 8 to 10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening/binding material to fill up the interstices of coarse aggregate, watering and compacting to the required density, etc. complete. Internal Bt Road For metal grade I, using stone screening type A
For metal grade II, using stone screening type B
Providing and constructing 50 mm. thick Modified Penetration Macadam (MPM) road surface including all mataerials, preparing the existing road surface, spreading 40mm. stone metal layers 100% crusher broken metal with conical crusher plant heating and spraying the bitumen of specified grade @ 1.75 Kilogram/Square Metre, spreading 12 mm.size chips compacting with static roller having weight 8 to 10 MT. to achive the desired degree of compaction as per Technical Specification Clause 506 etc. complete. Including picking of existing WBM surface.(VG-30 bulk bitumen rates are considered to arrive at rates)
BITUMINOUS MACADAM: Proving and laying bituminous macadam using crushed aggregates of Grading 1, premixed with bituminous binder, transported to site with VTS , laid over a previously prepared surface, finished to the required grade, level, alignment, and rolling to achieve the desired compaction for 80/100 mm compacted thickness with 3.3 % using VG-30 grade of Bitumen. -- USING Drum mix type hot mix plant with SCADA, Sensor Paver, vibratory roller.including tack coat
Open Graded Premix Surfacing- Providing and Laying OGC 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates premixed with bituminous binder transported to site with VTS , laid over a previously prepared surface, finished to the required grade, level, alignment, and rolling to achieve the desired compaction but including tack coat. For Bitumen of specified grade--USING drum mix type hot mix plant with SCADA, Paver and Vibratory roller( over BT Surface) (VG-30 bulk bitumen rates are considered to arrive at rates)
9 MM SEAL COAT: Providing and laying of Type A 9mm premix seal coat with HMP of apropriate capacity crushed stone chiping 6.7 mm size and penetration bitumen of specified grade @ 1.2kg/Sq.m, preparing existing road surface by mechanical means, spreading chips and rolling, by static roller having weight 8 to 10 MT. etc. complete.(VG-30 bulk bitumen rates are considered to arrive at rates)
Supplying hard murum/ kankar at the road site, including conveying and stacking complete.
Spreading hard murum/ soft murrum/ gravel or kankar for side width complete
Compacting the hard murum side widths including laying in layers on each side with vibratory roller including artificial watering etc. complete.
Road Marking with Hot Applied Thermoplastic Compound with Reflectorizing Glass Beads on Bituminous Surface- Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorizing glass beads @ 250 gms per One Square Metre area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes.complete.
Supplying and Fixing of Molded Shank Raised Pavement Markers / Cat's Eye made of polycarbonate and ABS moulded body and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face and shall support a load of 16000 kg tested in accordance to ASTM D 4280 Type H and complying to Specifications of Category A of MORTH Circular No RW/NH/33023/10-97 DO III Dt 11.06. 1997. The height, width and length shall not exceed 50 mm, 100 mm and 102 +/- 2 mm and with minimum reflective area of 13 Sqcm on each side and the slope to the base shall be 35 +/- 5 degree. The strength of detachment of the integrated cylindrical shanks, (of diameter not less than 19 +/- 2 mm and height not less than 30+/- 2 mm) from the body is to be a minimum value of 500 Kg. Fixing will be by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin based adhesive as per manufacturer's recommendation and complete as directed by the engineer.The contractor shall submit a two year warranty for satisfactory field performance including stipulated retro-reflectance of the reflecting panel, to the Engineer.
Providing and fixing of retro- reflectorised informatory sign board rectangular/Square in shape having area less than 0.9 square meter made out of ____mm aluminum sheet bonded with white retro reflective sheeting of Class __ ( Type IV High intensity micro-prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3, supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with two coats of grey stove enamel paint and supported on one no. mild steel angle iron post 75 mm x 75 mm x 6 mm, 3.5 mt long firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing The angle iron post shall be duly painted with one coat of epoxy primer and two coats of epoxy finish paints having alternate black and white bands of 25 cm width including GI fixures and transportation etc.complete.The nut bolts of board with angle iron post/supporting structure after fixing at site has to be electrically welded. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) sheeting shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier.
Providing and laying cement concrete pipe of IS 458:2003 NP-2 class of 450mm diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.
Full Height Partitions in Glass finish :- Providing and Fixing 80mm to 85mm thick Full height Double Skin Glass Finish partition with All visible sections in Natural Silver Anodizing finish. Made up of Frames and Tiles. Frame construction In combination of Aluminium and CRCA Rails with Vertical Channel / A Pole (Telescopic Channel of Aluminium Extrusion to give freedom of Height Variation in floor to ceiling heights at site) and Bottom ,Center and Top members, Connected with 2 way Round Shape Post , 3way Post , 4 way Post, Inline Post and End Joints made up of Aluminium Extruded with Silver Anodizing finish with minimum 1.3mm thickness and Tiles of 8mm thk. Toughened Glass from inner and 5 mm thk. Toughened Glass from outer With all the Joints of the partitions covered with PVC extrusions to provide better sound Proofing, as per design and drawing and instructions of Engineer in charge. Partly filmed and partly clear. (Sample to be got approved from Ex.Engineer/Consultant before use)
Full Height Partitions in Solid finish :- Providing and Fixing 80mm to 85mm thick Full height Double Skin partition up to 3 mtr height with All visible sections in Natural Silver Anodizing finish. Made up of Frames and Tiles. Frame construction In combination of Aluminium and CRCA Rails with Vertical Channel / A Pole (Telescopic Channel of Aluminium Extrusion to give freedom of Height Variation in floor to ceiling heights at site) and Bottom ,Center and Top members, Connected with 2 way Round Shape Post , 3way Post , 4 way Post, Inline Post and End Joints made up of Aluminium Extruded with Silver Anodizing finish with minimum 1.3mm thickness and Tiles in 12mm thk. Prelaminated Partial Board of on both side. With all the Joints in the partitions covered with PVC extrusions to provide better sound Proofing. Tiles to be separated 55mm from each other to provide adequate space for drawing cables for electric, data and telephone with proper facility for fixing electrical and data switch plates, as per design and drawing and instructions of Engineer in charge.
Glass Door With Door Frame :- Providing & fixing of Glass Door & Frame @ 900mm x 2100mm - 12mm thk toughened glass door All exposed edges of glass to be machine polished with frame in Anodized Aluminium with rubber gasket on both verticals for better sound proofing and provision for one side opening along Hardware consisting of Floor Spring Dorma/ Equivalent, Patch fitting of enox/ haffele/ Equivalent , Lock, door stopper and Handle, as per design and drawing and instructions of Engineer in charge.(Sample to be got approved from Ex.Engineer/Consultant before use)
Full Height PLYWOOD Partitions wall in Solid finish :- Providing and Fixing 80mm thick Full height Double Skin partition up to 4 mtr height with 600mm x 600mm plywood support frame. laminated Plywood sheet on both sides of ISO 710 quality. External laminate to be of minimum 1 mm thick of marino or equivalent company. laminate and plywood frame should be pasted with waterproof grade adhesive favicol Marine, Face plywood to be separated 50mm from each other to provide adequate space for drawing cables for electric, data and telephone with proper facility for fixing electrical and data switch plates, as per design and drawing and instructions of Engineer in charge. PINEWOOD DOOR : With 35 mm thick pine wood board, laminated on both sides External laminate to be of minimum 1 mm thick of marino or equivalent company. with 100 mm x 38 mm hinges of 4 One Number. Concealed auto door closer of ebco/ Haffele/enox/ ozone/ dorma Make etc. dead Lock, CP Handel, with other accessories as per design and drawing and instructions of Engineer in charge. (Sample to be got approved from Ex.Engineer/Consultant before use)
Medium Height Partition @ 1800/1200HT TILE BASED PARTITION SYSTEM:- Tile based Aluminum partition system of 1800/1200 mm ht. made of 60mm thk aluminum frames having two separate race ways for laying electrical & computer wiring. The wire management shall be through to the race way to be fitted at bottom of partition and other immediately below of work top with hook on type raceway cover for easy access of wires. Frames to be joined by aluminum connectors with M6 x 16 pan-head machin screw and washer with aluminum post cover. Post cover of snap on fashion to be connected on aluminum connectors. All visible aluminium to be in anodized finish. The top/ exposed sides of the frame and posts should be covered with horizontal/ Vertical trim and caps made of Aluminum in anodized finish in order to enhance its look.Upper tiles of partition to be in Soft Board or Marker tile of 9mm. thk., and prelaminated partical board lower tiles in laminate finish of 9mm. thk. on both the sides.(Sample to be got approved from Ex.Engineer/Consultant before use)
Rasper Clear Acrylic Writing Pad with Adjustable Height (Standard Size 21 * 15 INCHES) 8MM Thickness Colour Clear Transparent Special Feature Imported Material, Adjustable Height, 100% Genuine Product Of Rasper, Brass Hinges & Clipping Rods, Standard Office SizeImported Material, Adjustable Height, 100% Genuine Product Of Rasper, Brass Hinges & Clipping Rods, Standard Office Size
News paper reading stand Material Acrylonitrile Butadiene Styrene ColourNickel Grey & White Is Assembly RequiredYes Mounting TypeFloor Mount Weight19 Kilograms Product Dimensions90D x 90W x 60H Centimeters DURABLE DESIGN - Manufactured from prime quality CRCA steel tubes & sheets, NPS-01 Newspaper and Magazine Rack is extremely robust and sturdy. H-type cross bracings combined with leveling bolts at the bottom provide unmatched strength and stability to the product, even on uneven floor EASY INSTALLATION - The Newspaper Stand (reading tops and structure) is shipped in a dismantled state and can be easily assembled on-site without any hassles. A combination of intelligent design and standard hardware & joints not only make the assembly process easy but also make this stand highly portable and easy to store GREAT UTILITY - NPS-01 Newspaper Rack consists of 2 inclined reading tops mounted on a metallic structure and offers ample space to keep magazines, newspapers, brochures, catalogs or other print & advertisement media. A large display area and heavy-duty design makes this product ideal for schools, colleges, hotels, offices, libraries as well as public areas PREMIUM FINISH - The structure is epoxy powder coated in soothing Grey color and the reading tops are manufactured from prelaminated MDF in Grey color, to suit all contemporary presentation environments. All pipe ends are properly fitted with molded ABS end caps to give the product appealing aesthetics, superior finish and longevity SAFE PACKAGING - Just sit back and relax after you've placed the order, as NPS-01 Newspaper Rack is shipped in a customized heavy-duty and transit-worthy packaging exclusively designed for e-commerce shipments. Your package comes complete with the product, installation hardware and assembly manual
EXECUTIVE CLASS I TABLE 2400WX900DX750H WITH RETURN STORAGE @ 1050WX460DX750HT. & BACK STORAGE @ 1350WX460DX750H. 2 One Number . FOR CLASS ONE OFFICERS CABIN cabin table. Supply, Fitting & Fixing of Godrej/Red Apple/sos/Mubel or equivalent Cabin Table Work Top- Is made up of 38 mm thick dual color & As per approved design edge in Sandwich of 25 thk Prelam particle board and 12 mm thk BSL Prelam particle board confirming to IS 12823: 1990 with 2mm thick PVC lipping glued with Jowat-280.58 glue. Table top is under goes from distributed load test for deflection by applying 0.027kg/mm load on Top and concentric load test by applying 100 kg load on weaker section. Understructure –Gable end is made up of 38mm thick dual color edge in Sandwich of 25 thk Prelam particle board and 12 mm thk BSL Prelam particle board confirming to IS 12823: 1990 in slate grey with 2mm & 0.8mm thick PVC lipping glued with Jowat-280.58 glue. keyboard Slider with necessary fittings Sandwiching is done by using 10x12mm KD and 8x12mm Dowel Ebco keyboard tray with mouse tray. Gable end shall be fitted to the ground with M6x25 screw leveler with the height adjustment up to 12mm to 15mm.modesty is made up 18 mm thick Prelam particle board confirming to IS 12823: 1990 in slate grey OR As per approved design with 2mm & 0.8mm thick PVC lipping glued with Jowat-280.58 glue. Sandwiching is done at lower edge of the modesty by adding 18 mm thick Prelam particle board confirming to IS 12823: 1990.
EXECUTIVE TABLE 2100WX900DX750H WITH RETURN STORAGE @ 1050WX450DX650HT. &BACK STORAGE @ 1200WX450DX650H. 2 One Number . FOR CLASS II OFFICERS CABIN cabin table. Supply, Fitting & Fixing of Godrej/Red Apple/sos/Mubel Cabin Table Work Top- Is made up of 38mm thick dual color & As per approved design edge in Sandwich of 25 thk Prelam particle board and 12 mm thk BSL Prelam particle board confirming to IS 12823: 1990 with 2mm thick PVC lipping glued with Jowat-280.58 glue. Table top is under goes from distributed load test for deflection by applying 0.027kg/mm load on Top and concentric load test by applying 90kg load on weaker section. Understructure –Gable end is made up of 38mm thick dual color edge in Sandwich of 25 thk Prelam particle board and 12 mm thk BSL Prelam particle board confirming to IS 12823: 1990 in slate grey with 2mm & 0.45mm thick PVC lipping glued withJowat-280.58 glue. keyboard Slider with necessary fittings Sandwiching is done by using 10x12mm KD and 8x12mm Dowel Ebco keyboard tray with mouse tray. Gable end shall be fitted to the ground with M6x25 screw leveler with the height adjustment up to 12mm to 15mm.modesty is made up 18 mm thick Prelam particle board confirming to IS 12823: 1990 in slate grey OR As per approved design with 2mm & 0.45mm thick PVC lipping glued with Jowat-280.58 glue. Sandwiching is done at lower edge of the modesty by adding 18 mm thick Prelam particle board confirming to IS 12823: 1990.
HIGH BACK CHAIR FOR CLASS ONE & TWO OFFICERS Godrej or Equivalent Base : Nylon Dia 660mm Castor : Nylon, Dia 60mm Lumber : Yes Highlights:- 120 cm Colour: Black Dimensions 65 × 45 × 120 cm Revolving Chair Design: Ergonomicst Tan Gas Lift: Class 4 85mm StrokeMechanism: Tilting Wheels: 5 Nylon Wheels Arms: With kushan top : Pedastal Base: Nylon Seat Material: Leatherette Back Material: Leatherette Frame Material: Plywood Warranty: 2 Yrs Installation: Duet / Diy Care: Wipe Withclean Soft Cloth And Apply Liquid Leather Polish Features: Revolving, Swivel, Tilt Limitor minimum Weight: 21 Kgs
CLASS ONE & TWO OFFICERS CABIN VISITORS CHAIR wooden with arms. The seat and back shall be made up of wood veneer with foam back. The chair can also be provided with fixed wooden armrests .The dimensions of back shall be 49 cm (W) X 37 cm (H) and of seat shall be 51 cm (W) X 50.0cm (D). The Seat and Back Inner shall be upholstered with PU foam and fabric and shall be assembled over the seat and back. The chair is made of Rubber wood veneer with thickness of the leg 25 mm and width of the leg at 28mm. Seat Height - 46 cm, Height-83.0cm, Width & Depth of Chair as measured from base - Width-60.0cm and Depth-56.0 cm.Dimensions tolerance / variations shall be within +/- 1 cm. Waight Bearing Capacity Upto 90KG
3 SEATER TURF SOFA @ 1918LX775DX800HT. FOR CLASS I & II CABIN OVERALL SIZE -1830mm X 800mm X 760mm (LxDxH) for 3 seater sofa Supply and placing of Host sofa 3/2/1 SEATER seat height is 43cm,seat depth is,54cm understructure is made up of Natural Hard wood battens and 12mm THK COMMERCIAL PLYWOOD. Durable metal Springs in the seat give the sofa a springy comfort , allowing you to sit,relax and enjoy it for many Years. This cover is made from Vissle fabric in polyster, which is dope-duyed. It`s durable material with a smooth weave and nice two -tone effect.The Cover is easy to keep clean since it is removable and machine washable.
2 SEATER TURF SOFA @ 1415LX775DX800HT. FOR ANTICHAMBER OVERALL SIZE -1320mm X 800mm X 760mm (LxDxH) for 2 seater sofa Supply and placing of Host sofa 3/2/1 SEATER seat height is 43cm,seat depth is,54cm understructure is made up of Natural Hard wood battens and 12mm THK COMMERCIAL PLYWOOD. Durable metal Springs in the seat give the sofa a springy comfort , allowing you to sit,relax and enjoy it for many Years. This cover is made from Vissle fabric in polyster, which is dope-duyed. It`s durable material with a smooth weave and nice two -tone effect.The Cover is easy to keep clean since it is removable and machine washable.
Tea Table 900mm X 750mm X 450m Providing And Fixing Of Tea Table 900mm X 750mm X 450mm With 12mm Thick Colour Eitched Tempered Glass With Bevelled Drawing Made Out Of 18mm Thick Waterproofing HDMR Sheet. The Outer Laces To Be Finished With High Quality .
PRELAM SIDE TABLE @400LX400DX415HT. Body: SIZE: 420MM (L) X400MM (W) X450MM (H) The construction shall be aesthetically appealing completely knock down. Side panel and back panel is made from 18 mm Prelam (OSL) particle board conforming to IS 12823:1990. Side panel size LH and RH is 378MM (L) X422MM (W). All the exposed edges are with 2mm PVC lipping& sealed edges are with 0.8mm thick PVC Lipping. Both the LH & RH side panel and back panel are connected with each other by using fittings such as Minifix & Dowels. Fix shelf and bottom are made up of 18mm Prelam (BSL) particle board confirming to IS 12823: 1990 with 0.45mm thick PVC lipping glued with Jowat-280.58 glue. Seperator is support the drawer unit. Drawers –Size: 354MM (L) X350MM (W) X90MM (H) Drawer Front, back and side panel is made up 12mm thick Prelam (BSL) particle board confirming to IS 12823: 1990 with 0.45mm thick PVC lipping glued with Jowat-280.58 glue. Bottom panel is made up 9mm Prelam (OSL) particle board confirming to IS 12823: 1990.Bottom size is 340MM(L)X336MM(W) Drawer mounted on 37x400mm Telescopic slide (300MM) with full extension. C type handle is used in the drawer. Multipurpose square lock is used with locking strip.The product must be from a Manufacturer having ISO 9001,ISO 14001,Latest BIFMA 5.1 certificates for few of its products.
DUSTBIN SS Specification • Body Material - Stainless Steel • Model - Perforated • Shape - Round • No. of Pieces - 01 • Capacity - 7 ltr • Package Content - One pc Dustbin • Colour - Steel • Size - 35 cm Height, 20 cm dia.
PLASTIC CHAIR. DIMENSION: nilkalmal/equivalent.
FREE STANDING TABLE @ 1800LX750DX750Ht. For OFFICE CLASS III & IV Supply, Fitting & Fixing of Godrej/Red Apple/sos/Mubel Make Prelam Cabin. @ 1800LX750DX750HT. Work Top- Shall be made up of Work top shall be made 25mm thick Prelam (OSL) particle board confirming to IS 12823: 1990 with 2mm thick PVC lipping glued with Jowat-280.58 glue. Work top is under goes from distributed load test for deflection by applying 0.027kg/mm load on Top and concentric load test by applying 100kg load on weaker section Understructure- Modesty panel shall be made of 18mm thick Prelam BSL particle board confirming to IS 12823: 1990 with 2mm thick PVC lipping glued with Jowat-280.58 glue. Gable ends shall be made of 25mm thick Prelam BSL particle board confirming to IS12823: 1990. The construction shall be aesthetically appealing completely knock down construction fitting is done by using the Minifix & Dowels. Gable end height will be 725mm and its depth varies as per the depth of work top. Standard depth of work top will be 600mm and 750mm. keyboard Slider with necessary fittings Wire management- Wire manager cap on the table top shall be made of ABS material having Diameter 63.5mm standard Ebco keyboard tray with mouse tray .The product must be from a Manufacturer having ISO 9001,ISO 14001,Latest BIFMA 5.1 certificates for few of its products.
LOOP MID BACK CHAIR FOR OFFICE CLASS III & IV Loop – Specification Backrest : Mid back Upholstery : Backrest : Mesh (Black) Seat : Fabric with pu mould Armrest : fix Arm, Mechanism : Synchro 1P, Gaslift : Class 4, 120mm Stroke Base : Nylon Dia 660mm Castor : Nylon, Dia 60mm Lumber : Yes
PRELAM STORAGE @ 900LX450DX750HT. (89+72+109+103) = 373 Supply, Fitting & Fixing of Godrej/Red Apple/sos/Mube Make Prelam Storage. Storage Top- Shall be made of 25mm thick Prelam (OSL) particle board for low height Prelam storage up to 750 Height and above 750mm height 18mm Thick prelam (OSl) particle board is used. Both the 25mm and 18mm thick Prelam (OSL) particle board confirming to IS 12823: 1990 with 2mm thick PVC lipping glued with Jowat-280.58 glue. Storage top is under goes from distributed load test for deflection by applying 0.027kg/mm load on Top and concentric load test by applying 90kg load on weaker section. Load carrying capacity of 18mm thick shelf shall be 25kgs UDL. Storage Body- The construction shall be aesthetically appealing completely knock down construction .side panel and back panel is made from 18 mm Prelam (OSL) particle board conforming to IS 12823:1990;. All the exposed edges are with 2mm PVC lipping& sealed edges are with 0.8mm thick PVC Lipping. Both the LH & RH side panel and back panel are connected with each other by using fittings such as Minifix & Dowels. Shelf can be made up of 18mm Prelam (BSL) particle board confirming to IS 12823: 1990 with 2mm thick PVC lipping glued with Jowat-280.58 glue. Shelf is mounted on shelf pin and self-height can be adjusted with in the limit. Prelam Shutter- The complete storage shall have two shutters of 18mm thick Prelam (OSL) particle board confirming to IS 12823: 1990 with 2mm thick PVC lipping glued with Jowat-280.58 glue glue and are hinged shutter with equal width hung with 0 Crank on side panel and 9.5 crank hinges on middle vertical panel. C type SS brush finish handle is used in both the shutter of 96mm CD(center to center distance handle hole)and Hettich make. Black color PVC door strip and multi-purpose square lock (Hettich or Ebco) is used.
PRELAM STORAGE @ 900LX450DX1500HT. Supply, Fitting & Fixing of Godrej/Red Apple/sos/Mube Make Prelam Storage. Storage Top- Shall be made of 25mm thick Prelam (OSL) particle board for low height Prelam storage up to 750 Height and above 750mm height 18mm Thick prelam (OSl) particle board is used. Both the 25mm and 18mm thick Prelam (OSL) particle board confirming to IS 12823: 1990 with 2mm thick PVC lipping glued with Jowat-280.58 glue. Storage top is under goes from distributed load test for deflection by applying 0.027kg/mm load on Top and concentric load test by applying 90kg load on weaker section. Load carrying capacity of 18mm thick shelf shall be 25kgs UDL. Storage Body- The construction shall be aesthetically appealing completely knock down construction .side panel and back panel is made from 18 mm Prelam (OSL) particle board conforming to IS 12823:1990;. All the exposed edges are with 2mm PVC lipping& sealed edges are with 0.8mm thick PVC Lipping. Both the LH & RH side panel and back panel are connected with each other by using fittings such as Minifix & Dowels. Shelf can be made up of 18mm Prelam (BSL) particle board confirming to IS 12823: 1990 with 2mm thick PVC lipping glued with Jowat-280.58 glue. Shelf is mounted on shelf pin and self-height can be adjusted with in the limit. Prelam Shutter- The complete storage shall have two shutters of 18mm thick Prelam (OSL) particle board confirming to IS 12823: 1990 with 2mm thick PVC lipping glued with Jowat-280.58 glue glue and are hinged shutter with equal width hung with 0 Crank on side panel and 9.5 crank hinges on middle vertical panel. C type SS brush finish handle is used in both the shutter of 96mm CD(center to center distance handle hole)and Hettich make. Black color PVC door strip and multi-purpose square lock (Hettich or Ebco) is used.
Full Height Steel Storage @ 900Lx450Dx2100H (13+46+21+39) = 119 Providing and fixing Openable Steel Storage of 750 x 450 x 2100Ht, with 4 adjustable shelves, Complete body & shutter made in 0.8 mm thick & Top in 1 mm thick CRCA, 4 Shutter to be mounted with the help of cup hinges, and 4 adjustable levelers, enitre storage in powder coated finish with 60 to 80 microns as as per drawing.
Double Faced Mobile Unit for Compactor 2150mmH x 2745mmW x 900mmD Providing and fixing Double Faced Mobile Unit for Compactor 2150mmH x 2745mmW x 900mmD - BASE FRAME : Base Frame shall be fabricated in channel Type from minimum 2.5 mm thick MS Sheet Size of Channel 25mm x 100mm x 45mm. GUIDE RAILS : The guide rails shall be made out of 28mm Bright bar placed on 1.2 mm thick M.S. Plate which will be above the floor and are as per the international standard of safety. SUPER STRUCTURE : Super structure of the Mobile storage system will consist of knock down type panels. All the components such as shelves, front panel, end panel, vertical rear panel, central partition etc. Will act as an integral member of the Unit. SHELVES : Shelves made of 22SWG thick Prime Quality C.R.C.A. having 10 folds each will be provided each designed to carry a U.D.L. of 70 Kilograms. VERTICAL PANEL : Vertical panel consists of the front, Centre & rear panel shall be made out of 20SWG thick C.R.C.A. Prime quality Mild Steel & designed to take the load of shelves. DRIVE COVER PANEL : Made out of 22SWG thick C. R.C. A. prime quality Steel to cover the entire drive mechanism. CENTRE PARTITION : The Centre partition will comprise of a full C.R.C.A. prime quality Mild Steel 22SWG Sheet. LOCKING : System will be provided with individual rack locking as well as centralised locking arrangement on the last unit when all units are brought together, central lock when operated gets locked with the floor & does not allow access to the units. DRIVE MECHANISM : Driving Mechanism will be provided externally supported on special grade anti-friction bearing to have smooth & effortless movement. Entire mechanism or gear & sprockets shall be incorporated within the front panel provided in the front of the unit within an area of 1000mm x 200mm x 60mm. DRIVING WHEEL : Fully Powder Coated three pronged drive wheel for better torque & free movement of the rack over the guide rail. INDEXING ARRANGEMENT : Acrylic card holders provided on the front panel for easy identification & retrieval. FINAL FINISH : Powder Coating (8 tanks process with 70 microns).
Single Faced Mobile Unit for Compactor 2150mmH x 2745mmW x 457mmD Providing and fixing Single Faced Mobile Unit for Compactor 2150mmH x 2745mmW x 457mmD - BASE FRAME : Base Frame shall be fabricated in channel Type from minimum 2.5 mm thick MS Sheet Size of Channel 25mm x 100mm x 45mm. GUIDE RAILS : The guide rails shall be made out of 28mm Bright bar placed on 1.2 mm thick M.S. Plate which will be above the floor and are as per the international standard of safety. SUPER STRUCTURE : Super structure of the Mobile storage system will consist of knock down type panels. All the components such as shelves, front panel, end panel, vertical rear panel, central partition etc. Will act as an integral member of the Unit. SHELVES : Shelves made of 22SWG thick Prime Quality C.R.C.A. having 10 folds each will be provided each designed to carry a U.D.L. of 70 Kilograms. VERTICAL PANEL : Vertical panel consists of the front, Centre & rear panel shall be made out of 20SWG thick C.R.C.A. Prime quality Mild Steel & designed to take the load of shelves. DRIVE COVER PANEL : Made out of 22SWG thick C. R.C. A. prime quality Steel to cover the entire drive mechanism. CENTRE PARTITION : The Centre partition will comprise of a full C.R.C.A. prime quality Mild Steel 22SWG Sheet. LOCKING : System will be provided with individual rack locking as well as centralised locking arrangement on the last unit when all units are brought together, central lock when operated gets locked with the floor & does not allow access to the units. DRIVE MECHANISM : Driving Mechanism will be provided externally supported on special grade anti-friction bearing to have smooth & effortless movement. Entire mechanism or gear & sprockets shall be incorporated within the front panel provided in the front of the unit within an area of 1000mm x 200mm x 60mm. DRIVING WHEEL : Fully Powder Coated three pronged drive wheel for better torque & free movement of the rack over the guide rail. INDEXING ARRANGEMENT : Acrylic card holders provided on the front panel for easy identification & retrieval. FINAL FINISH : Powder Coating (8 tanks process with 70 microns).
3 SEATER AMIGO CHAIR WITH CUSION Upholstery : Leatherite (Black) Understructure : MS pipe Finish : Powder coat Foot pad : PP glide Seat & Back Cushion : with Cushion No of Seater : 3 seater
U SHAPRE PRELAM CONFERENCE TABLE @ FOR CONFERENCE HALL Prelam Conference Table- Supply, Fitting & Fixing of Godrej/Red Apple/sos/Mube Make Prelam Conference. Work Top- Shall be made up of Work top shall be made 25mm thick Prelam (OSL) particle board confirming to IS 12823: 1990 with 2mm thick PVC lipping glued with Jowat-280.58 glue. Work top is under goes from distributed load test for deflection by applying 0.027kg/mm load on Top and concentric load test by applying 90kg load on weaker section. Work top shape can be a round or rectangular. Understructure-Modesty panel shall be made of 18mm thick Prelam BSL particle board confirming to IS 12823: 1990 with 2mm thick PVC lipping glued withJowat-280.58 glue. Gable ends shall be made of 25mm thick Prelam BSL particle board confirming to IS12823: 1990. The construction shall be aesthetically appealing completely knock down construction fitting is done by using the Minifix & Dowels. Gable end height will be 725mm and its depth varies as per the depth of work top standard. Wire management- Electrical wires shall be carried from 100x100mm vertical duct or Snake (Vertigo), vertical duct shall be made of 0.7mm CRCA sheet confirming to IS 513:2008.Horizontally wire shall float in switch mounted box 400LX174DX125H shall be made of 0.7mm CRCA sheet confirming to IS 513:2008. Switch plate is provided on Switch Mounting Box. Switch Plate shall be made up of 1.5mm CRCA sheet confirming to IS 513:2008 and switch plate can be screwed on switch mounting box or cable tray by using 8x15 mm Pan Head ST Screw. Access flap will be fitted on work top above to the switch mounting box. Access flap and its components shall be made of aluminum extrusions of material AL6963-T6. The product must be from a Manufacturer having ISO 9001,ISO 14001,Latest BIFMA 5.1 certificates for few of its products.
HIGH BACK CHAIR CONFERENCE Room Adjustable Seat Height, Armrest, Locking Mechanism, Seat Lock, Swivel, Wheels, Head Support W x H : 63 cm x 114 cm Frame Material : Sold Wood Upholstery Type : Cushion Diy : Basic assembly to be done with simple tools by the customer, comes with instructions.
CONFERENCE ROOM CHAIRS Loop – Specification Backrest : Mid back Upholstery : Backrest : Mesh (Black) Seat : Fabric Armrest : Fixed Arm, Mechanism : Synchro 1P, Gaslift : Class 4, 120mm Stroke Base : Nylon Dia 660mm Castor : Nylon, Dia 60mm Lumber : Yes
SINGLE BED WITH MATRESS @2020LX960DX750/600HT. (H) WITH SIDE TABLE @ 450LX450DX520HT. FOR ROOM Material Specification : W Single Bed Head / Tail / Side Board : Made up of 18mm THK Pre- Lam Particle board with 2mm thk PVC lipping Bed Board : Made up of 18mm THK Pre- Lam Particle board with 0.8mm thk PVC edge banding. Pre-Lam Particle board conforms to IS 12823:1990 with a thickness of 2mm and PVC lipping with JOWAT-280.58 glue. Metal Understructure : 'C' type frame & Cross members are made up of in 25X25X1.2mm THK MS Square pipe conforms to IS 4923 and the frame finished with powder coat up to 50 -60 MICRON. Foot pad : Made up of injection moulded in Nylon, Diameter 15mm and 7mm thk on the Head and Tail Board and 25 X 25 X 3thk Injection moulded nylon bush on Square pipe. Suitable mattress size : 78"X36" Construction : Flat Pack BED SIDE TABLE:- Made up of 18mm THK Pre- Lam Particle board with 2mm thk PVC edge banding. Drawer Assembly: Drawer fascia made up of 18mm THK Pre- Lam Particle board with 2.0mm thk PVC edge banding. Drawer internal made up of 18mm THK Pre- Lam Particle board with 0.8mm thk PVC edge banding.. Drawer Talia is made up of 9mm THK Pre- Lam Particle board . Pre-Lam Particle board conforms to IS 12823:2015 with a thickness of 2mm and PVC lipping with JOWAT-280.58 glue. KNOB: Made up of mild steel and finished with chrome, Diameter 20mm and 20mm Long. FOOT PAD : Made up of injection moulded in Nylon, Diameter 15mm and 7mm thk Dimensions : 450 (L) x 450 (W) X450 (H) HANDEL: Made up of mild steel and finished with crome. Construction : Flat Pack
SS DINING TABLE WITH FIXED CHAIR- FOR CANTEEN Top- Top is made up of Stainless steel having a length of 1800(L) X 760(D) X 750(H) confirming the grade 304 Understructure- legs vertical member are made up of 40 x 40 x 1.2 mm thick MS pipe confirming the IS 4932 with powder coated finish up to 50 to 60 Micron. Horizontal member is made up of 25 x 25 x 1.2 mm thick confirming the IS 4923with powder coated finish up to 50 to 60 Micron. Both the horizontal and vertical pipes are welded together by MIG welding confirming to IS standard IS 816:1969 and it is welding also tested by confirming to IS 822:1970. Understructure height will be 725mm from the ground, and the bench height will be 500mm from the ground.
METAL STORAGE @ 900LX450DX1980HT. Storage body- The construction and material of storage body shall be of 0.8mm thick CRCA and skirting shall be of 1.2mm thick CRCA sheet confirming to IS 513: 2008 with powder coated finish up to 50 to 60 Micron. The storage top shall be made up of 2mm thick CRCA sheet with 0.7 mm thick CRCA sheet T-HAT for extra support. Shelf shall be made up of 0.8mm CRCA sheet confirming to IS 513: 2008 with 0.8mm Thick CRCA sheet T-HAT is given for extra support. Shelf shall be mounted with the Metal shelf support pin made of 2mm thick CRCA sheet with Nickel or Chrome plating. Load bearing capacity of the shelf shall be 30Kgs UDL. The construction shall be aesthetically appealing completely welded. M10 screw leveler is given with height adjustment up to 12mm to 15mm Glass shutter- Glass shutter can be offered with 4mm toughened clear glass which is surrounded with 1mm thick Aluminum Extrusion frame confirming the IS 733:1983.Shutter is hinged shutter with equal width hung with 0 Crank side panels. Multipurpose square lock is used to lock the shutter. SS C type SS brush finish handle is used in both the shutter of 96mm CD (center to center distance of handle hole)
SLOTTED ANGLE RACK @ 900LX600DX2100HT Slotted Angle Rack Supply and installation of slotted angle rack Slotted angle- Slotted angle is made up 2mm thick CRCA sheet confirming the IS grade IS 513:2008 coated with final finish consisting of epoxy polyester powder coat of approved color & shade with a Dry Film Thickness of minimum 50 to 60 microns. Angle length is equivalent to the height of the storage which is approx. 2100mm or 1830mm Shelf-Is made up of 0.8mm CRCA sheet confirming the IS grade IS 513:2008. All the four edge is having a bend of 25mm. Shelf is supported by T-Hat in the middle portion. T-hat is made up of 0.8mm CRCA sheet confirming the IS Grade IS 513:2008.Each shelf is having loading carrying capacity of 18kg UDL and total load carrying capacity of unit is 50kg UDL. Finish- The bodies including shelves are given anti-rust surface treatment & are powder coated with epoxy polyester powder. It involves an Oxsilan pre-treatment consisting of Hot water degreasing, cold water rinse I & cold water rinse II, iron phosphate, cold water rinse, and passivation & dry off oven treatment. Final finish consists of epoxy polyester powder coating of approved color & shade with a Dry Film Thickness of 50 to 60 (+\- 5) microns. The material is then oven baked with a controlled temperature of 180 deg.C to 200 deg.C. Fasteners:- Assembly is done with the help of M8 NUT nuts & HEX BOLT M8 X 16.
Electrical Work Supplying and erecting HMS PVC conduit FRLS grade 20 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
Supplying and laying HMS PVC conduit FRLS grade 20 mm dia. with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.
Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.
Supplying and erecting HMS PVC conduit FRLS grade 32 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
Supplying and laying HMS PVC conduit FRLS grade 32mm dia. with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.
Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
Supplying and erecting mains with 1x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting mains with 1x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting mains with 1x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting mains with 2x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting mains with 4x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting mains with 1x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting mains with 4x10 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
Supplying and erecting mains with 1x10 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type bell-push 6A / 10A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type switch 16 / 20 A with indicator, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting PVC Surface modular switch box with double mounting plate for 2 module duly erected.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting 16 / 20 / 25 A starter (modular range) 2 module for AC unit on provided box complete & duly concealed with necessary material and connected.
Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/CW
Point wiring for ceiling fan concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/CW
Point wiring for light/bell/exhaust fan in 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW.
Point wiring for light/bell hybrid type (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/HW
Point wiring for ceiling fan (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/HW
Wiring for plug on board with Switch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification No: WG-PW/CW
Supplying and erecting LED square / circular Max. 18 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
Supplying and erecting LED square / circular Max. 25 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2750 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., THD<10%, p.f. >0.95, operating range of 140-260V, in built surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty.
Supplying and erecting anodized aluminium corridor / passage / mirror light LED fitting (2 feet) Max. 12W with high transitivity diffuser with min. system lumens output of 1200 lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver with end caps on provided PVC Block / wooden board with 3 years warranty.
Supplying and erecting CRCA powder coated corridor/passage light LED fitting (4 feet) Max. 17W with high transitivity diffuser with system lumens output of Min. 2000 lumens , min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver, with end caps on provided PVC Block / wooden board with 3 years warranty.
Supplying and erecting ding dong / electronic musical type call bell with heavy duty coil suitable to operate on 230V A.C. supply erected on polished double wooden block/sunmica block of suitable size.
Supplying and erecting luminous / modular type call bell indicator with plastic body, heavy duty coil and indicator lamp working on 230V A.C. supply with resetting arrangement complete erected on double wooden/ sunmica board.
Supplying and erecting integrated LED street light fitting 40 to 50W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 4400 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K,THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2.
Supplying and erecting street light Wall bracket made from 40 mm. dia ‘ G.I. pipe 1.2 m. in total length complete as per specification no. FG-BKT/WB
Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 300mm. 1400 RPM rust proof body & blades, wire mesh, duly erected, complete.
Supplying and erecting exhaust fan heavy duty 230 V, A.C. 50 cycles 375/380 mm. 900 RPM complete erected in position as per specification no. FG-FN/EXF
Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1200 mm, max. energy consumption of 28W having service ratio (CMM/W) of Min. 8 , PF>0.9, THD<10% with IR remote control/compatible speed regulator, Temperature Rise of Max. 40 deg. C, having external mounted control PCB completely erected in position as per specification no. FG-FN/CF
Supplying and erecting fan hook of 10 mm. M.S. round bar grouted in RCC slab with making the site as original.
Supplying and erecting ‘B’ class G.I .pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire. (444X1.2 = 532.8 Mtr )
Providing recess in brick wall suitable for erection of exhaust fan up to 450mm. sweep complete with grouting of nut, bolts, plastering and colour washing to match the colour of the wall for the wall thickness of 225 mm.
Supplying & erecting 22 SWG G.I sheet metal cawl sector shaped with 25 x 25 x 3 (mm) angle iron frame, metal mesh to avoid birds entry with necessary material, suitable for exhaust fan of 300 mm as per specification no FG-FAS/MSC
Supplying & erecting 22 SWG G.I sheet metal cawl sector shaped with 25 x 25 x 3 (mm) angle iron frame, metal mesh to avoid birds entry with necessary material, suitable for exhaust fan of 400 mm as per specification no FG-FAS/MSC
Supplying, erecting, testing and commissioning self contained water cooler 230/250V 50Hz nominal cooling capacity of 150 litres per hour and storage capacity 150 litres with partially stainless steel body as per specification no. AP-WCR/WC
Supplying and erecting ultra violet storage type water purifier (RO+UV+UF) with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire and two indicator lamps with output of purified water minimum 0.33 litre/min with activated carbon filter and softener operating on 230V, single phase A.C. supply with UV fail & filter change indication system .(for TDS more than 200)
Supplying & erecting four pole ON LOAD change over switch, 415V, 200A, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, operational current category AC23A complying to IS/IEC 60947-3 Part-1/3.
Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking TPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting and marking four pole isolators only switch version of miniature circuit breakers of 63A in provided distribution board.
Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 4 ways/phase (12 poles), with door, 1.2mm thickness, surface/flush mounted, IP 43 protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB
Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 8 ways / phase (24 poles), with door, 1.2mm thickness surface/ flush mounted, IP 43 Protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB
Supplying & erecting triple pole and neutral distribution board (TPNDB), SP/TP MCBs total 4 ways /12 Poles, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB
Supplying & erecting triple pole and neutral distribution board (TPNDB), SP/TP MCBs total 8 ways /24 poles, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB
Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB
Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame.
Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/ 4 pole MCCB as incomer & outgoing SP MCB (12 poles) or TP MCB of 4 ways (12 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1
Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/4 pole MCCB as incomer & outgoing SP MCB (24 poles) or TP MCB of 8 ways (24 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1
Providing & erecting 3 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB
Providing & erecting 4 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB ( 5309 * 1.2 = 6370.80 )
Providing & erecting 4 Pole MCCB 415V, 250A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu) adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB ( 14159 * 1.2 = 16990.80 )
Supplying, fixing and commissioning 2 pole RCBO 32/40A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO
Supplying, fixing and commissioning 4 pole RCBO 32/40A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO
Supplying, fixing and commissioning 4 pole RCBO 63A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO
Providing & erecting floor/wall mounting, MCCB panel board, with door, suitable for four pole incoming 250A, 8 ways Four pole outgoing, up to 100 A MCCBs on iron frame, as per specification no SW-SWR/MCCBPB. (Excluding MCCBs)
Providing & erecting incoming and outgoing cable alleys suitable for MCCB panel board with door, 250A incoming and 8 way outgoing or 400A incoming and 6 way outgoing made from CRCA sheet 1.6 mm thick duly powder coated and having vertical insulated partition for shielding between the shared face of cableway and DB.
Providing & erecting prewired meter module suitable for MCCB panel board with CTs and emfs VIF meter.
Supplying & erecting porcelain/epoxy bus bar support complete erected in provided M.S. box for 200/300A
Supplying and erecting metal work in CRCA sheet including Iron work for supports with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete.
Supplying and erecting GI sheet 1.6 mm (16 SWG) caution board of size 200 x 150 mm duly painted with red oxide and enamel paint in Marathi, Hindi and English erected at position for medium voltage (415 Volt) installation with compliance to IS 2551-1982
Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.
Supplying and erecting of any size electrolyte aluminium patti or bar in bus bar chamber / in panel or any other purpose, 500 V with require capacity 99.9% aluminium purity with E91E Grade as per IS 5082 & Current Density 0.8 A per sq. mm. with fixing arrangement (like lug or bottle type lug) to both the end with high grade polyolefin insulation sleeve complete as per specification no. BCP-BB ( 40 x10 mm.) ( 24 mt @ 1.08 kg./mtr = 25.92 say 26 kg. )
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 50 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 150 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 300 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 25 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying & erecting G.I. pipe ‘A’ class 75 mm dia. erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE
Supplying & laying (including excavation) reinforced cement concrete pipe of IS 458:2003 NP-2 class of 150 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 120 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP
Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP
Providing earthing with copper earth plate size 60 x 60 x 0.315 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover with minimum 25 kg Carbon based environment friendly back fill Ground Enhancing compound complete with all materials, testing & recording the results as per specification no ESE -LA
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.
Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws complete.
Providing and back filling ground enhancing compound 25 kg bag complete.
Lumpsump provision for MSEDCL Connection
Lan Van Wiring Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.
Supplying and erecting modular type computer Jack RJ45 with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and installing cat-6 LSZH cable suitable for networking as per specification no. WG-COC/NC
Supplying and erecting LSZH armoured multimode optical fibre cable with 6 fibres, core dia 50/125 µm (OM3), suitable upto 10 GBPS, ethernet distance at 850 nm of wavelength, on wall/ceiling or laid in provided pipe/trench as per specification no. WG-COC/OFC LSZH
Supplying and fixing 1 m UTP patch cord of Cat 6 type in position as per specification No. WG-COC/PC
Supplying and fixing 3 m UTP patch cord of Cat 6 type in position as per specification No. WG-COC/PC
Supplying, fixing, and configuring 24 ports with 4 (SFP+) port, ethernet managed switch with web view/CLI, 6KV surge protection on ethernet port and console port for management in provided rack as per specification no. WG-NWC/GBS
Supplying, fixing, and configuring broadband ADSL router with all accessories, on provided rack as per specification No. WG-NWC/ADSL
Supplying and fixing tool-less IO (Ethernet) flush/surface type in provided modular box as per specification no. WG-NAS/IO
Supplying and fixing 24 port patch panel with tool-less keystone jacks in provided U Rack complete as per specification no. WG-NAS/PP
Supplying and fixing 6U wall mount rack (Dimension-DxWxH – 500x600x367 mm) as per specification No. WG-NAS/RAK
Street lights Supplying and erecting 25 mm dia. corrugated flexible polypropylene conduit
Supplying and erecting mains with 4x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting PVC insulated PVC round sheathed 2.5 sq.mm (50 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV
Supplying and erecting integrated LED street light fitting 70-75W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 7700 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K,THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2.
Supplying and erecting integrated LED Bollard Cylindrical/Cubical shaped 800mm 8W IP65 & IK10 class having extrusion aluminium housing with polycarbonate diffuser, having system lumens output of Min. 800 Lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-240V, inbuilt surge protection of 2 kV, Life class of 25,000 Hrs. at L50B50, including driver complete with 2 Year warranty as per specification No FG-ODF/FLS2.
Supplying, erecting & marking SPMCB 0.5A to 5A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying & erecting G.I. pipe ‘A’ class 40 mm dia. erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
Providing & erecting 8 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 135 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL
Providing and erecting galvanised 1500 mm single arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT
Providing and erecting galvanised 1500 mm double arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT
Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP
Providing and back filling ground enhancing compound 25 kg bag complete.
Excavating hard Rock or bituminous road by chiselling for preparing pit for pole / stay/earth plate / for laying cable/ pipe & clearing the site by removing debris & making the site as required complete. (V = 7 X 0.45 X 0.4 X 2 nos) + (0.4x.45x0.4 x2 ) = 2.52 + 0.144 = 2.66 say 3 cu.mtr. )
Making cement concrete foundation in 1:3:6 cement concrete, (20 to 25) mm. stone metal duly plastered with necessary curing for complete. (pole muffing or any other purpose). (V = 7 X 0.45 X 0.4 X 2 nos) + (0.4x.45x0.4 x2 ) = 2.52 + 0.144 = 2.66 say 3 cu.mtr. ))
Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 6m to 8m high octagonal /conical GI pole).
Supplying and erecting ISI mark GI pipe 50 mm dia.‘B’ class at position with accessories complete as per specification no. CW-PLB/GP.
Submersible Pump set on Sump / Bore Well Supplying and erecting 25 mm dia. corrugated flexible polypropylene conduit
Supplying and erecting mains with 4x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting switch disconnector fuse (SDF) 415V, 25/32A, with enclosure, triple pole and neutral link AC23 A rated with terminal shrouds on both sides and phase barriers along with telescopic shaft for depth adjustments and door interlock and padlock complying to IS/IEC 60947-3 Part-1/3 HRC - DIN type fuse switch , insulation voltage 1000 V, with rotary handle for ON / OFF operation (without HRC fuse)
Supplying & erecting four pole ON LOAD change over switch, 415V, 40A, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, rotary handle,operational current category AC23A complying to IS/IEC 60947-3 Part-1/3.
Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying & erecting triple pole and neutral distribution board (TPNDB), SP/TP MCBs total 4 ways /12 Poles, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB
Supplying, fixing and commissioning 4 pole RCBO 63A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO
Supplying and erecting metal work in CRCA sheet including Iron work for supports with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete.
Supplying and erecting plywood 12 mm thick fixed to wall or on provided panel board with necessary materials such as screws, wall fasteners supports, nuts bolts etc. complete.
Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 25 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying & erecting G.I. pipe ‘A’ class 25 mm dia. erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE
Supplying & erecting G.I. pipe ‘A’ class 40 mm dia. erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP
Providing and back filling ground enhancing compound 25 kg bag complete.
Supplying and erecting minimum Three & above star rated submersible pump set of 4.5 KW/6 HP with 415 V, 50 c/s AC supply suitable for 150 mm dia. borewell suitable for 60 to 180 LPM discharge at 177 to 88 m head & discharge & delivery pipe of Size-50 mm diameter with a necessary H type clamps as per specification No. WP-SMP
Supplying and erecting minimum Three & above star rated submersible pump set suitable for erection on open well of 5.625 KW/7.5 HP with 415 V 50 c/s. A.C. supply, having delivery head from 57 to 22 m and discharge from 120 to 900 litres. . per minute & pipe of Suction 75 mm/Delivery 65 mm diameter erected with necessary H type clamps as per specification No. WP-OSP
Supplying & erecting flat flexible 3 core 6 sq.mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete.
Supplying & erecting automatic control panel for 3 Phase , 415 volt, A.C, Submersible/centrifugal pump set up to 7.5 HP consisting of DOL starter having relay range 9-14 AMP,S.P.P., Combined ammeter/ voltmeter, phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing, phase reversal, phase imbalance etc .
Making cement concrete foundation in 1:3:6 cement concrete, (20 to 25) mm. stone metal duly plastered with necessary curing for complete. (pole muffing or any other purpose).
Supplying and erecting ISI mark GI pipe 65 mm. dia. ‘B’ class at position with accessories complete as per specification no. CW-PLB/GP.
Supplying and erecting high density polythene pipe ISI mark 50 mm. dia. suitable for pressure of 6 kg. / cm2 connected to jet/submersible pump with required material complete.
Supplying and erecting 65 mm dia. gun metal sluice valve at position with necessary materials complete.
Supplying and erecting non return valve 65 mm dia in position made of gun metal complete.
Supplying and erecting CI flange 65 mm. dia with necessary nuts bolts and washers with rubber seal in position complete.
Diesel Generator Set of 200 KVA capacity Supplying and erecting GI sheet 1.6 mm (16 SWG) caution board of size 200 x 150 mm duly painted with red oxide and enamel paint in Marathi, Hindi and English erected at position for medium voltage (415 Volt) installation with compliance to IS 2551-1982
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 185 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying & erecting G.I. pipe ‘A’ class 75 mm dia. erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE
Supplying & laying (including excavation) reinforced cement concrete pipe of IS 458:2003 NP-2 class of 150 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 120 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP
Supplying and erecting aluminium strip of high purity required sizes used for earthing on wall and/or any other purpose with necessary aluminium clamps fixed on wall painted with bituminous paint with joints required as per specification no EA-EP.
Supplying, erecting, testing and commissioning of diesel generating set with alternator of 200 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C supply, a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with performance class G2 and maximum fuel consumption 34.40 Ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level up to 75 dB(A) at 1.0 m, provided with first filling of oil, diesel not less than 300 Ltr etc. on provided M20 Grade CC Foundation as per specification no. GEN-DG
Supplying, erecting, testing and commissioning of microprocessor based AMF panel suitable for diesel generating set of above 180 kVA up to 200 kVA capacity Three phase, 415 Volts, 50Hz A.C. with all standard features, safeties etc as per specification no. GEN-AMF. ( FR- 185054 /- Reduce by 10 % = 166548.60 )
Excavating hard Rock or bituminous road by chiselling for preparing pit for pole / stay/earth plate / for laying cable/ pipe & clearing the site by removing debris & making the site as required complete. (5 X 3 X 0.7+5X3X 0.7=10.50 CuM )
Making cement concrete foundation in 1:3:6 cement concrete, (20 to 25) mm. stone metal duly plastered with necessary curing for complete. (pole muffing or any other purpose). (4.5 X 2.5 X 1+4.5 X 2.5 X 1= 11.25 +11.25 CuM )
Supplying and erecting ISI mark GI pipe 75/80 mm dia. ‘B’ class at position with accessories complete. Specification no. CW-PLB/GP.
Air Conditioning system Supplying, erecting, testing and commissioning of 10HP, VRF/VRV air conditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56° C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000m operation in cooling mode with inverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete.
Supplying, erecting, testing and commissioning 16 HP Each HP, VRF / VRV air conditioning system, out door unit (ODU) complying type-IV OEM standards working on HFC free refrigerant R410A or other required/suitable green equivalent refrigerant, for cooling capacity delivering 100% at 47 deg. celcius and non stop cooling even at 56 deg. celsius and coefficient of performance (COP) 3.00 to 4.00, modular type horizontal/vertical hot air discharge suitable for total piping length upto 1000 metre operation in cooling mode with inverter based VRF/VRV technology microprocessor based control compressor starter/control panel complete with scroll compressor, air cooled anti corrosive copper condenser coil of suitable shape for increasing maximum heat transfer area, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V ± 10%, 50 Hz, 3 phase power supply, internal copper refrigerant piping, internal wiring and first charge of refrigerant, etc. all housed in powder coated weather proof cabinet on provided angle iron frame or suitable foundation connected to the system in approved manner complete.
Cassetee AC Supply, installation, testing and commissioning of VRF/VRV Each based ceiling suspended 4 Way cassette indor unit (IDU) compact / standard size of nominal cooling capacity 2.0TR ( 618 cfm ) / 2.3TR ( 671 cfm ) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. Indoor Units complete with in-built drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anticorrosive coating suitable for coastal area complete in all respects, to operate on 1-phase, 230V, 50Hz, AC input supply, consisting with any additional refrigerant and oil charge as per requirement during installation and connected to the system complete
Supplying and installation of high pressure grade required size copper connection Y or T- Joints / refnet for liquid and suction line complete erected on wall/ceiling with supports/raceways, Nitrile rubber insulation, painting etc. with brazing and testing for leakages confirming the normal operation of the VRV / VRF air conditioning system
Supplying, erecting, testing and commissioning centralised programmable remote contol panel (HMI) touch manager controls minimum 16 system of minimum 64 ODU's can be controlled and up to 992 IDU's can be individually mounted and controlled indoor units having minimum 200 mm size colour LCD touch panel, yearly schedule, power proportional distribution function, temperature limitation, history function complete erected on wall with an arrangement to integrate with provided fire alarm system
Supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor. room air conditioning unit 1.7TR to 2.0TR capacity having ISEER minimum 5.0 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position in provided recess with wooden frame complete specification no. AP-AC/WAC
Supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 12mm complete.
Supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 16mm complete.
Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 41.3 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.
Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 34.9 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees,valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.
Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 28.6 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.
Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 22.2 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system
Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 19.1 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.
Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 15.9 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.
Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 12.7 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.
Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 9.5 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.
Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 6.4 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.
Supply, Installation, Testing and Commissioning of drain piping conformimg to IS :1239 /3589 heavy class inculding all fitting like anchor fasteners , pipe supporting , frame structure , coupling , bends, elbows, tees, flanges, tappings, wall sleeves, hangers and rigid polyurethane foam block etc. Pipe should be insulated with 9 mm thick EPDM rubber with adhesive.25 mm Dia
Supply, Installation, Testing and Commissioning of drain piping conformimg to IS :1239 /3589 heavy class inculding all fitting like anchor fasteners , pipe supporting , frame structure , coupling , bends, elbows, tees, flanges, tappings, wall sleeves, hangers and rigid polyurethane foam block etc. Pipe should be insulated with 9 mm thick EPDM rubber with adhesive.32 mm Dia
Supplying and erecting iron, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.
Providing vaccumising the airconditioner system to 200 micron and charging with R-410A/R32 refrigerant for air conditioning unit.
Providing & erecting Hot dipped galvanized ladder type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 500 mm width & 100 mm height comprising all required standard accessories
Providing & erecting Hot dipped galvanized cover suitable for perforated type cable tray manufactured from 18 swg (1.2 mm thick) GI sheet of 500 mm width & 20 mm height complete with necessary hardware in approved manner.
Supplying, erecting & terminating XLPE armoured cable 3 core 2.5 sq. mm. copper conductor continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying, erecting & terminating XLPE armoured cable 4 core 6 sq. mm. copper conductor continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying and erecting PVC insulated PVC round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 Kv
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 4 sq. mm. aluminium m 135 conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Carrying out core cutting of size 3" to 5" dia x 15" length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original. (CSR-3-11-77)
Fire Fighting System Supplying, installation, testing and commissioning of main fire pump (MFP / EP) suitable for water discharge of 2280 to 2850LPM at 80 to 60 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 45kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal type, single stage, centrifugal/split casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/EP
Supplying, installation, testing and commissioning of jockey fire pump (JP) suitable for water discharge of 180 to 240 LPM at 90 to 70 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 9.3 kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal/vertical type, multi stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003)complete, as per specification no. FF-MFP/JP
Supplying, installation, testing and commissioning of booster fire pump [BP] suitable for water discharge of 900 LPM at 35 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 7.5 kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal/vertical type, single/multi stage, centrifugal casing pump of cast iron body & bronze/CI impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation on with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d)Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/BP
Supplying, installation, testing and commissioning of main fire pump (MFP/DP) suitable for water discharge of 2280 to 2850 LPM at 90 to 60 m head driven by 76 HP or suitable HP capacity diesel engine at required working speed suitable for manual/automatic operation and consisting of following : (a) Horizontal type, single stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520. (b) Water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12/24 volts DC electric starting equipment with battery of required AH capacity with necessary charger suitable to work on 230v, 50Hz AC supply, diesel tank of minimum 150ltr capacity with first filling of diesel up to 100% level with necessary piping with valves up to engine, exhaust pipe extended up to 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications etc. as required. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with engine assembly and accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/DP
For main electric motor driven fire hydrant system pump of 45kW capacity & relevant capacity jockey pump add Rs….
for 5.5/ 7.5 kW centrifugal type booster pump 1no(1working) , add Rs…....
Supplying and erecting G.I. pipe ‘C’ class ERW 25 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe ‘C’ class ERW 50 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe ‘C’ class ERW 65 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe ‘C’ class ERW 75/80 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe ‘C’ class ERW 100 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe ‘C’ class ERW 150 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe ‘C’ class ERW 200 mm dia with necessary fittings complete as per specification no. FF-PP
Providing coating of bitumen paint & 4mm thick wrapping for underground 100 mm ring main of fire fighting system.
Providing coating of bitumen paint & 4mm thick wrapping for underground 150 mm ring main of fire fighting system.
Supplying and erecting 100 mm dia cast iron foot valve ball type/flap type with strainer for negative suction complete as per specification no. FF-VL/FV
Supplying and erecting 150 mm dia cast iron foot valve ball type/flap type with strainer for negative suction complete as per specification no. FF-VL/FV
Supplying and erecting 100 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SS screen, end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS
Supplying and erecting 50 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
Supplying and erecting 75/80 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
Supplying and erecting 100 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
Supplying and erecting 150 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
Supplying and erecting 75/80 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV
Supplying and erecting 100 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV
Supplying and erecting 150 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV
Supplying and erecting 25 mm dia gun metal gate valve complete with PN16 pressure rating, as per specification no. FF-VL/GV
Supplying and erecting stainless steel single outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV
Supplying and installing one piece moulded HDPE / fibre water tank for negative suction only, having capacity 1000 litres fitted with necessary accessories complete as per specification no. FF-FFA/PT
Supplying and installing wall mounting swinging hose reel drum fitted with 19 mm dia. 30m long high pressure polypropylene (Polyhose) along with necessary accessories complete as per specification no. FF-FFA/HV
Supplying and erecting 63mm dia, reinforced rubber lined (R.R.L.) hose pipe, 15m in length, fitted with necessary accessories complete as per specification no. FF-FFA/RRL
Supplying and erecting stainless steel branch pipe 63 mm dia fitted with 20 mm dia detachable hexagonal nozzle complete as per specifications no. FFFFA/ NZ
Supplying and erecting fire brigade header of 150 mm dia, for supplying water in fire tank complete as per specification no. FFFA/ FBC
Supplying and erecting 150 mm dia fire brigade header suitable for supplying water in fire tank complete as per specification no. FF-FA/FBC
Supplying and erecting 300 mm dia 1.5m in height air vessel / tank fabricated from min 5mm thick M.S. sheet complete as per specification no. FF-FFA/ACT
Supplying and erecting 20/25mm dia gun metal air release cock, with necessary G.I. coupling to be fitted on top of air vessel or on wet riser complete as per specification no. FF-FFA/ARV
Supplying and erecting 100 mm dia. pressure gauge , 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, erected with provided G.I. pipe, elbow etc. complete as per specification no. FF-FFA/PG
Supplying and erecting 12/15 mm dia pressure switch with provided isolation valve, G.I. nipple, elbow, etc complete as per specification no. FF-FFA/PS
Supplying and erecting brass orifice plate having 6 mm. thickness, 140 mm outer dia with required diameter of inner hole at every single outlet hydrant valve as per specification no. FF-FFA/OP
Supplying and erecting M.S./CRCA cabinet for housing Floor Hydrant valve, hose pipe, hose reel and branch pipe (size 1000 x 736 x 736 mm.) made from 16 SWG sheet and angle iron 25 x 25 x 4 mm. having front doors with viewing glass (8"x6") and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5)
Supplying, erecting, testing and commissioning of quartzoid bulb sprinkler, 15 mm (½") dia. NBCM Body chrome finished, 68º C fixed temperature rating with deflector disc of conventional construction complete as per specification no. FFSPR.
Supplying, erecting, testing and commissioning vane type water flow detector 100 mm dia. with 1) Visual switch activation 2) Rugged switch assembly 3) Heavy duty aluminium pipe saddles 4)Durable metal enclosure 5) Steel U bolts for secure mounting 6) Two SPDT ( Single pole double track ) synchronised switches 7) serviceable without draining pipes.
Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete.
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 70 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, installing, testing and commissioning FR, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU
Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 150 mm width & 75 mm height complete with necessary coupler plates & hardware.
Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.
Supplying and erecting non return valve 50 mm dia in position made of gun metal complete.
Excavating soft murum / soft soil road by chiselling for preparing pit for poles stay or earth plates or for laying cables, pipes & clearing the site by removing debris & making the site good complete.
Carrying out core cutting of size 3" to 5" dia x 15" length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original.
Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.
Supplying and erecting ABC powder type fire extinguisher as per IS : 13849 /15683 of 6 kg capacity with necessary clamp for erection on wall. (Note this rate are taken from CSR 2021-2022 dated 1st Septecmber 2021 Chapter No. 10 iten No. 10-2-34)
Providing Round bottom fire bucket of 9 Litres capacity as per IS : 2546 made out of 24 gauge G.I. sheet with extra handle at bottom duly painted white inside and red outside with FIRE Mark, on provided stand/ wall hook complete. (Note this rateare taken from CSR 2021-2022 dated 1st Septecmber 2021 Chapter No. 10 iten No. 10-2-24)
Providing Floor mounting stand for keeping 4 Nos. of FIRE buckets 1500mm in length, 900mm in height frame made out of 30x30x4 mm angle iron with cross supports for legs, welded with 4 hooks and duly painted with one coat of red lead and two coats of silver paint complete. (Note this rate are taken from CSR 2021-2022 dated 1st Septecmber 2021 Chapter No. 10 iten No. 10-2-25)
Supply, fixing & testing of illuminated LED Exit signages with battery backup upto 8 hrs at prominent place for identification in case of emergency.
Supply, installation, testing and commissioning of 150 mm dia. Installation Wet Alarm Valve with Water Motor Gong, Pressure Gauges, Test Lines with Ball Valves with necessary GI (H) piping with threaded fittings of required sizes complete.
Providing and fixing UL/Fm listed SS unbraided flexible pipe 1000/1200mm long with accessories complete with all accessories specified in technical specifications(Size=15B)
Fire door : Providing , supplying , fabricating & Installing of 120 minutes fire rated Hinged Metal Fire Door 1200x2100 mm of make Rated Un insulated Single 50 mm thk with honeycomb infill Sgl/Dbl Rbt 143 x 57 mm frame straight with anchor fastners frame 1.0 & shutter 0.9 mm, Powder coated to RAL Shade , SFP SS Ball Bearing 4" X 3" X 3 mm Hinge For Steel , Dorset Sash Lock Body EC Dorset Both Side Key 70 mm Dorset SS Mortise/Lever Handle on Rose 22 mm dialngersoll Rand Briton 121.NCE.SES Door Closer Size 3 with Standard Arm, Sprayed Silver Finish with all fixtures & fasteners including all Taxes and as per drawing directed as per Engineer - in - charge . fire rated Hinged Metal Fire Door 1200x2100 mm
Supplying, installing, testing and commissioning remote response indicators suitable to operate on 5 -28 V dc supply having FR Polymer ABS Housing complete as per specification no. FF-FAAS/RRI
Supplying, installing, testing and commissioning FR, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU
Supplying, installing, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the 8 loop capacity and capable of supporting upto 250 devices and detectors per loop, with on-board LCD display with min 16 lines of text, operating at 230 V 50 HZ - AC with inbuilt Battery Backup of a minimum 24 hours in normal condition and 30 min in alarm condition, suitable provision for network connectivity, interfacing with third party equipment via a MODBUS/ OPC/ L-ON interface etc. conforming to IS 15908:2021, IS 2189: 2008, EN 54 & VDS / FM/ UL 864 (10th edition) with 3 years replacement warranty FF-AFAS/CP
Supplying, installing, testing and commissioning of repeater panel with suitable battery backup of a minimum of 24 hours in normal condition and 30 min in alarm condition, 80 backlit alphanumeric LCD display with inbuilt buzzer to indicate fault/fire alarm, manual control keys for silence/mute and to reset the FACP from the repeater station. Panel size shall not more than 175 x 275 x 65 mm conforming to EN 54 or UL approved with 3 years equipment replacement warranty FF-AFAS/RP
Supplying, installing, testing and commissioning of addressable optical smoke detector, single/twin LED’s with 360 degree view, suitable for low voltage 15 to 32 V DC two wires supply, in-built locking mechanism to check the removal and pilferage of the detector, in built isolation mode, start up current 300μA and alarm condition current shall be maximum 6.5 mA, operating temperature 0°C to 50°C, humidity 0-95% RH, IP 41, conforming to IS 2189: 2008, 11360_1985_Reff2020 EN 54 or UL Approved with 3 years equipment replacement warranty FFAFAS/ SD .
Supplying, installing, testing and commissioning of intelligent addressable thermal/ heat detector with rate of rise cum fixed temperature thermistor complete with base as required, suitable for temperature variations from - 20°C to 38 °C for fixed-heat and rate-of-rise type detectors whereas 0°C to 90°C for high heat type detectors, in built isolation mode, suitable for industrial/ kitchen/ boiler room etc. with 3 years equipment replacement warranty, IS : 2175-1988 reaffirmed 2000, IS 15908:2021 standards FF-AFAS/SD.
Supplying, installing, testing and commissioning of addressable manual call points ( break glass type/pull station type), made of addressable break glass plastic square in shape surface/flush mounted with "Break Glass" massage embedded on the glass, complete erected with mounting base and required accessories conforming to EN 54 or UL listed with 3 years equipment replacement warranty FF-AFAS/MCP.
Supplying, installing, testing and commissioning of addressable fire control/relay module complete as required, with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 reed relays, EN 54 or UL Listed FF-AFAS/CRM
Supplying, installing, testing and commissioning of addressable fire monitor module complete as required. EN 54 or UL Listed with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 Reed relays FF-AFAS/MM
Supplying, installing, testing and commissioning of addressable fire isolator module complete as required. EN 54 /FM or UL Listed with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 Reed relays FF-AFAS/ISM
Supplying, installing, testing and commissioning of addressable horn cum strobe sound/ hooter, output frequency 500 to 1000 Hz with dB as per Chart given in IS 15908:2021, with flashing at 1 Hz over the strobe’s entire operating voltage range EN 54, conforming to IS 2189: 2008, IS 15908:2021 standards with 3 years equipment replacement warranty FF-AFAS/SSH.
Supplying, erecting, testing and commissioning 120 W amplifier suitable to operate on 230 Volts A.C. / 12 Volts D.C. supply complete as per specification no. FF-PA/AFR
Supplying, erecting, testing and commissioning 15 to 30 Watts sound column or ceiling mounted complete as per specification no. FF-PA/SOC
Supplying, erecting, testing and commissioning stand mounted/handheld type wired microphone having 2 mV/Pa sensitivity, impedance level limit 300 ohms and 50 - 16000 Hz suitable to operate in -10 deg C to +55 deg C with min. 7 metre shielded cable and 3 Pin Professional XLR Connector, stereo jack complete as per specification no. FF-PA/MIC
Supplying, erecting, testing and commissioning rust free microphone floor stand of chrome plating/powder coating or S.S. material , 500 mm to 1500 mm height and sturdy mechanism ensuring trouble free movement complete.
Supplying, erecting, testing and commissioning of 2 core shielded cable complete as per specification no. FF-PA/MCC
Supplying, erecting, testing and commissioning of 1.5 sq. mm speaker wire complete.
CCTV Arrangement Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.
Supplying and erecting 20mm dia. corrugated flexible polypropylene conduit
Supplying and erecting 25 mm dia. corrugated flexible polypropylene conduit
Supplying and erecting 15m HDMI cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19 pin HDMI connectors complete.
Supplying and installing enhanced cat-6 cable with 4-connector channel, performance test report as per ANSI/TIA-568.2-D suitable for networking complete as per specification.
Supplying, fixing, and configuring 8-ports managed gigabit, Layer-2 switch, 10/100/1000 base-T, POE smart switch plus 2 SFP erected in provided rack complete.
Supplying, fixing, and configuring 24 ports, POE switch in provided rack as per specification No. WG-NWC/ENS
Supplying, installing and testing UTP connector (RJ-45) as per specification No. WG-NAS/UTPC.
Supplying and fixing 6U wall mount rack (Dimension-DxWxH – 500x600x367 mm) as per specification No. WG-NAS/RAK
Supplying and fixing 32 U floor mount server Rack (Dimension-DxWxH - 800X1000x1620 mm) as per specification No. WG-NAS/RAK
Supplying and erecting LSZH armoured multimode optical fibre cable with 6 fibres, core dia 50/125 µm (OM3), suitable upto 10 GBPS, ethernet distance at 850 nm of wavelength, on wall/ceiling or laid in provided pipe/trench as per specification no. WG-COC/OFC LSZH
Supplying, erecting, testing and commissioning of 2kVA capacity online pure sine wave, with backup time of ....... hrs. PWM & IGBT based UPS with 0.8 to unity output pf, single phase input & 1 phase output complete with all protections as per specification no. AP-UPS
Supplying, erecting, Testing & Commissioning of 4MP Camera Bullet with necessary accessories i).Video Compression Ultra 265, H.265, H.264, MJPEG ii)Video Resolution Sub Stream:2MP (1920×1080): Max. 30 fps; Third Stream: D1(720×576) : Max. 30fps iii)Frame Rate Main Stream:4MP (2592×1520): . 20 fps,4MP (2560×1440): Max 25 fps,3MP (2048×1520): Max. 30 fps; Sub Stream:2MP (1920×1080 iv)Image Sensor Intrusion, crossing line, motion detection v)Lens Type 1/3", progressive scan ,4.0 megapixel, CMOS vi)Lens [email protected] vii) Minimum Illmage Settings SMART Behavior Detection Intrusion, crossing line, motion detection , Intelligent Identification Face detection, IP Address Filtering viii) Image settings Rotate Mode, Saturation, Brightness, Contrast, Sharpness adjustable by client software or web browser ix)Audio Two-way audio Supported STORAGE Edge Storage Micro SD, up to 128 GB Network Storage ANR, NAS (Network Attached Storage) x) Protocol L2TP, IPv4,IGMP,ICMP,ARP,TCP,UDP,DHCP,PPPoE, FTP, UPnP, HTTP, HTTPS, SMTP, SIP, 802.1x xi) Security IP Address Filtering, output, Access Policy,ARP Protection, RTSP Authentication, User Authentication xii)Operating Conditions Wide temperature range: -35°C to + 60°C (-31°F to 140°F), Humidity < 95% RH ( Non -Condensing) xiii) Intelligent Identification Face detection, Defocus, Scene Change xiv) Edge Storage Micro SD, up to 128 GB xv) Casing Metal
Supplying, erecting, Testing & Commissioning of 4MP Camera Dome with necessary accessories : i).Video Compression Ultra 265, H.265, H.264, MJPEG ii)Video Resolution Sub Stream:2MP (1920×1080): Max. 30 fps; Third Stream: D1(720×576) : Max. 30fps iii)Frame Rate Main Stream:4MP (2592×1520): , 20 fps,4MP (2560×1440): Max 25 fps,3MP (2048×1520): Max. 30 fps; Sub Stream:2MP (1920×1080 iv)Image Sensor Intrusion, crossing line, motion detection v)Lens Type 1/3", progressive scan ,4.0 megapixel, CMOS vi)Lens 3.6mm @ F2.0, Angle of view ( H): 72.0° vii) Minimum Illmage Settings SMART Behavior Detection Intrusion, crossing line, motion detection , Intelligent Identification Face detection, IP Address Filtering viii) Image settings Rotate Mode, Saturation, Brightness, Contrast, Sharpness adjustable by client software or web browser ix)Audio Two-way audio Supported STORAGE Edge Storage Micro SD, up to 128 GB Network Storage ANR, NAS (Network Attached Storage) x) Protocol L2TP, IPv4,IGMP,ICMP,ARP,TCP,UDP,DHCP,PPPoE, FTP, UPnP, HTTP, HTTPS, SMTP, SIP, 802.1x xi) Security IP Address Filtering, output, Access Policy,ARP Protection, RTSP Authentication, User Authentication xii)Operating Conditions Wide temperature range: -35°C to + 60°C (-31°F to 140°F), Humidity < 95% RH ( Non -Condensing) xiii) Intelligent Identification Face detection xiv) Edge Storage Micro SD, up to 128 xv) Casing Metal
Supplying, erecting, Testing & Commissioning 4MP Camera PTZ with necessary accessories i).Video Compression:-H.265 /H.264 / MJPEG ii).Video Resolution :-1080P(1920×1080)/720P(1280×720)/D1(704×576/ 704×480), CIF(352×288/352×240, iii)Frame Rate :-Main Stream : 1080P(1~25/30fps), 720P(1~50/60fps), Sub Stream 2: 1080P/720P/D1/CIF (1 ~ 25/30fps), Sub Stream 1: D1/CIF(1 ~ 25/30fps) iv).Image Sensor :-1/1.9" CMOS, Activate Preset/ Scan/ Tour/ Pattern if there is no command in the specied period v).Lens Type :-Powerful 30x optical zoom/ Fixed focal/Vary focal vi).Lens :-1/1.9” 4 Megapixel CMOS,4XDigital Zoom,10X optical Zoom vii) lmage Settings :-Max. 25/30fps@1080P and 50/60fps@720P Compression,Colour,Brightness, Sharpness,Contrast,White Balance,Exposure control,Back light compensation ,Auto tracking,Pre-set tour settings viii).Panning Range :-Pan: 0° ~ 360° endless; Tilt: -20° ~ 90°,auto ip 180° ix).Tilting Range :-Pan: 0° ~ 360° endless; Tilt: -0° ~ 90°,auto ip 180° ix).Tilting Range :-Pan: 0° ~ 360° endless; Tilt: -0° ~ 90°,auto ip 180° x) Manual Control Speed :-Pan: 0.1° ~200° /s; Tilt: 0.1° ~120° /s xi).Image settings :- Auto xii).Audio :-one way audio Supported Storage/Built in microphone xiii).Protocol :-NETWORK Protocols IPv4, IGMP, ICMP, ARP, TCP, UDP, DHCP, PPPoE, RTP, RTSP, RTCP, DNS, DDNS, NTP, FTP, UPnP, HTTP, HTTPS, SMTP, 802.1x xiv).Security :-IP Address Filtering, output, Access Policy,ARP Protection, RTSP Authentication, User Authentication xv) Operating Conditions :-Wide temperature range: -40°C to 60°C (-40°F to 140°F) xvi ) Casing :-Metal ,IP-66 xvii) Minimum illumination :- Colour : 0.5 lux,B/W :0.1 lux(at30 IRE)
64ch Network Video Recorder-Connect Up to 64 IP Cameras, Up to 12 Megapixels Resolution,Two independent HDMI outputs, one HDMI output of 4K resolution,1 VGA output with output upto 1920 × 1080, Support H.265, MJPEG,Supports N+1 hot spare system,Supports RAID0, RAID1, RAID5, RAID6 and RAID10 ,Supports HDD hot swap, Supports Dual Power-Redundant,Incoming Bandwidth 320 Mbps, 8 SATA Hard Disks, ANR Technology, 8 SATA interfaces for 8 HDDs and capacity of each HDD upto 6TB, 3 × USB at least 1 × USB with 3.0, Alarm I/O 16/4, RS-485, RS-232, 2 RJ-45 10 /100/1000 Mbps self-adaptive Ethernet interface, Multiple network monitoring: Web viewer.
Supplying, erecting,testing and commissioning of 4 TB Capacity internal SATA HDD
Supplying, erecting, Commissioning & Testing Screen (108 Cm) /43 Inch pecifications General o Screen Size : 108 cm (43) • Screen Type : LED • HD Technology & Resolution : Full HD TV , 1920 x 1080 • HDMI : 3, USB : 1 • Launch Year : 2018 onnectivity Features : HDMI, 2 Side : USB o 1 Side Video Features • Contrast Ratio : Mega Contrast (Static) • Picture Engine : Hyper real • View Angle : 178 Degree • Panel Type : A+, Digital Noise Filter : Yes • LED Display Type : Direct • Aspect Ratio 16:09 • Refresh Rate o 60 Hz • Other Video Features o PMI 300: Clarity, Color, Contrast, Active Noise Reduction, Dynamic Color Enhancer o Picture Mode: 8 Modes (Vivid, Standard, APS, Cinema, Cricket, Game, Expert1, Expert2) o Picture: JPEG, Digital Noise Reduction, Movies Support in USB Mode, MPEG H.264 Decoder o Response Time: 6.5 ms, Still Image, Wide Color Enhancer (Plus), Film Mode, Cricket mode Audio Features • Number of Speakers : 2 • Speaker Type: Down Firing with Bass Reflex • Sound Technology : Dolby Digital Plus • Speaker Output RMS : 20 W Warranty • Warranty Summary : 1 Year Comprehensive and 1 Year Additional on Panel
Atal Realtech Ltd
D. V. Patel and Company
M/s. Tirupati Construction Company
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf