| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.0 LAccepted-AOC | L1 | Accepted-AOC Being L1 Bidder | |
| 2 | L2₹16.8 L+₹78,165 (4.89%)Rejected-Finance | L2 | Rejected-Finance Being L2 Bidder | |
| 3 | L3₹16.8 L+₹80,282 (5.02%)Rejected-Finance | L3 | Rejected-Finance Being L3 Bidder | |
| 4 | L4₹17.0 L+₹1.0 L (6.37%)Rejected-Finance INDIRA HATIA BIRBHUM | BIRBHUM | WEST BENGAL | L4 | Rejected-Finance Being L4 Bidder |
Tender Value
Refer Docs
EMD Value
₹32,000
Closing Date
22 Aug 2019, 6:55 pmClosed
Exe Eng,Birbhum Elec Divn.
Laldighipara, P.O. Suri Dist. Birbhum. Pin. 731101 Near Suri Sadar Hospital
Construction of two pump fire station at Sainthia in the district of Birbhum during the year 2016-17..... Additional E.I works with S and F of fittings and Fixtures and SITC of Compound light, LC, LED sign Board and AC.
2019_WBPWD_237162_1
BIRED/03/e-Q (2nd call) of 2019-20
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
Suri
Please refer Tender documents.
8 documents required · 8 mandatory
₹32,000
20 Jul 2020
7 Aug 2019
26 Aug 2019
7 Aug 2019
22 Aug 2019
7 Aug 2019
Amount
Supply of following PVC/XLPE insulated & Sheathed cables for Working Voltage up to 1100 Volts of following sizes [Make- Havells / Polycab/ Gloster / Currency / KEI / As per choice of EIC]
4 core 2.5 sq. mm. multy stranded copper conductor unarmoured cable.
4 core 6 sq. mm. multy stranded alluminium conductor Armoured cable.
Supplying and fixing compression type gland and finishing those for following XLPE / PVC armoured cable (2/4 / 3.5)Core as per GS.
4 Core 2.5 Sq. mm [8-b(x)/F-5]
4 Core 6 Sq. mm [7(c)/F-4]
Laying of one No. cable upto 35 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. as per GS. [1(a)/ F- 2]
Laying of cable having following size, on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting.
Upto 2 core 25 sqmm [2(a)/F-1]
Upto 3/4 core 25 sqmm [2(b)/F-1]
S & F G.I cable looping box of size (250x150x100)mm with all accessories as per GS on wall. [5/H-5]
Supplying & fixing medium gauge 25 mm dia GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required. [ 11(a)/ F- 6 ]
Fixing only single/twin florescent light fitting complete with all accessories Directly on wall/ceiling as per GS. [14(d)/C-2]
Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps as per GS. [ 17 /C-2]
Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. [ 16 /C-2]
S & F 10W LED Bulb [Essential /PHILIPS /Magik] on existing batten holder/As directed by EIC.
Supply of 4 Ft. 20 Watt single/twin LED light fitting for indoor application, complete with all accessories having following Model / Cat No. [Make:-Crompton /Magik /As per choice of EIC]
Cat No.- IGP161LT8-16/Similar model
Cat No.- IGP162LT8-16/Similar model
Supply of 4 Ft. 16 Watt single/twin LED light for indoor application, having following Model / Cat No. [Make:- Crompton Cat No.- LTT8-16/Similar model /Magik /As per choice of EIC]
S&F following model, LED out door luminaire on existing arm bracket. [Make:- Crompton /Magik /Phillips /As per Coice of EIC]
(Cat no:- LSTP-45-CDL/Similar Model)
(Cat no:- LSTP-72-CDL/Similar Model)
(Cat no:- LSTN-90-CDL-A/Similar Model)
(Cat no:- LSTN-120-CDL-A/Similar Model)
(Cat no:- LSTN-150-CDL-A/Similar Model)
S&F 10W LED Flood Light on Ceiling by nut bolts arrangement. [Make:- Magik Atlantis-FWAT010C0761/Similar Model of Crompton /Phillips /As per Coice of EIC]
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc as per GS [ 21 (a) / C-3 ]
Engraving the deptt. number with 10 mm lettering on the body of fan upto 10 letters incl. hifen, stroke or stop [ 24 (a) / C-3 ]
Extra for additional one letter incl. hifen, stroke and stop[ 24 (b) / C-3 ]
Painting upto 10 letters of the engraved number with approved black /red paint as required[ 26 (a) / C-3 ]
Extra painting for additional one letter of the engraved number with hifen, stroke etc. with black or red paint [ 26 (b) / C-3 ]
Fixing only 30 cm (12") exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection [ 28 (b) / C-4 ]
Fixing only louver shutter/cowl on wall with necy. bolts & nuts (6 mm dia x 62 mm long) For 30 cm (12") Exhaust fan [ 30 (b) / C-4]
Supply of 1200 mm sweep ceiling fan complete with blades, canopy, fork, rubber bush etc as per GS (Make - USHA- Stiker Galoxy /Crompton- Aura Metalic/ As per choice of EIC )
Supply of 12" ( 300mm ) Speed 1420 RPM Exhaust fans complete with all accessories having the following Model / Cat No. ( Make -EPC /Usha/Crompton/ As per choice of EIC)
Supply & fixing of 18mm &8mm heavy gauge copper pipe line from indoor unit to outdoor unit including keno foam insulation & electrical line from indoor unit to outdoor unit with 4 X 2.5 Sq.mm copper wire cable
SITC of 2.0 TR split type room Air Conditiner (cooling only) having the following specification & features.: a) Cooling capacity nominal (BTU /HR): 24907; Cooling Cap(min) Guaranteed (BTU/HR):25248 b) Star Rating -4 star c) Rated Voltage-230 V + / -5%, Frequency -50 Hz d) Compressor type- Rotary e) Mini. Room Discharge Air Flow Rate-1300CMH f) Refrigrant: R- 410A f) Cordless Remote Arrangement with all modernized provision of temperature setting , Fan speed option ( Low. Medium /High ) Auto Swing h) Operating Outdoor Temparature :- 50ºC and above. (Make :- MITSUBISHI Hevy/O' General/DIKINAs per choice of EIC, ) With 15A plug top, 2mt long input cord , & all other installation kit except indoor to out door unit connecting pipes & cables, out door unit will be fixed on wall with heavy type wall base.Incl supply of wall base./on floor with necessary iron chair (300mm hight). fixed on roof floor.
Supply & fixing of 20 mm dia Schedule 40 PVC pipe for drain out the water from cooling unit.
SITC of Microprocessor Base Call Bell with individual as well as master control switch/Road signaling system for controling road vehicles when even fire fighting viehicle make entry & exit from fire station/ Numbering Display Control Box for awareness of driver present at parking lot. having following features:- 1).Supply Voltage:- 230 Volts; 2).Frequency:- 50 Hz; 3).Mounting Type:- Mounted on wall/As per directed by EIC; 4).Surge Protection:- Yes; 5).Size:-24" x 18" x 6-12", Double Door, 14 SWG MS Box; 6).Microprocessor Base Contact:- As required; 7).Indication Lamp:- (i)amber- As required, (ii)red- As required, (iii)green- As required; 8).6A Bell push switch:- As required; 9).6A switch:- As required; 10).Make:- As per choice of EIC. 11).Neutral & Earth Bar:- As per direction of EIC; 12).20 Way, 6A, Backlite Connector:- As required; 13).32A DP Isolator:- As required; 14).6A SPMCB (C-Characteristic)[Make:- Legrand]:- As required; 15).Real Time Base microprocessor unit incl. Digital Display Unit, having scroll up/down/erase/add option for show the last 100 data storing register with 12V DC, 7.2A-hr Battery back up unit; 16).Computer Base Software system incl. HDMI/VGA Cable having atleast 3 Mtr Length/As directed by EIC; incl. fixing of 1.5/2.5/4 sqmm copper control wire, cable marker ferrule, socket, DIN rail as required and painting by powder coated paint as per choice of EIC.
SITC of Real Time Base microprocessor unit incl. Digital Display Unit, having scroll up/down/erase/add option for show the last 100 data storing register with 12V DC, 7.2A-hr Battery back up unit for Fire Station Annunciator Unit including Computer Base Software system incl. HDMI/VGA Cable having 3 Mtr Length for computer base operation.
SITC (0 to 9)showing One Digit Numbering Display with Control Unit, having following features:- 1).Supply Voltage:- 230 Volts; 2).Frequency:- 50 Hz; 3).Mounting Type:-(i).Display Unit Mounting On:- Fire station Garage/As per directed by EIC, (ii).Control Unit Mounting On:- Control Box/As per directed by EIC; 4).Surge Protection:- Yes; 5).Display Unit Size:- 12" x 12"; 6).Bit Size:- 4" x 1/2"; 7).Control with Power Cable Length:- 65 Mtr; incl. required nuts, bolts, etc., Display Unit Covered by Alluminium housing and painting the same by powder coated paint.
Supply of Red-Green 100mm dia. each, LED Signal Light having following features:- Supply Voltage:- 230 Volts; Frequency:- 50 Hz; Mounting Type:- Horizontal Mounting; Surge Protection:- Yes; Make:- As per choice of EIC. The lights are assembled in the same housing, which is painting by powder coated paint as per choice of EIC and fixing the same with1.5x1.5 inch angel / flate iron frame.
Wiring with 3X 1.5 Sqmm PVC copper wire in 13mm dia polythene pipe from loop box to LED Traffic Light. (average run 8mt)
S&making with1.5x1.5 inch angel / flate iron frame approx length 5feet and fixing the same in two nos. GI Octagonal Pole by nuts bolts arrangement & proper fixing of signal lighting & painting the avove frame work incl. Necesary connection of suitable copper wire from loop box to signal light.
Plan Drawing with details Electrical Drawing incl. Single Line Diagram of whole system, as directed by EIC.
S & F Lightning conductor Air-terminals made of 15 mm dia 1500 mm long GI pipe (ISI Medium) having five prongs of 4 SWG GI (Hot Dip) wire at top with 85 mm dia 6 mm thick GI base plate at bottom incl. necessary holes etc. duly grouted on the parapet etc. in CC mortar (4:2:1)
Supply & fixing GI (Hot Dip) strips 20 mm x 3 mm thick for horizontal run on the Parapet/Roof/ Wall with GI Saddles 1100 mm apart incl. mending good the damages to building works
Supply & fixing of GI (Hot Dip) strips 20 mm x 3 mm thick for vertical run on wall with GI saddles spaced not exceeding 1000 mm apart incl. mending good damages to building work
Making soldered joints between conductors and down pipes/ other metallic objects for 14 SWG GI (Hot Dip) wire including supply of necessary 4 SWG GI (Hot Dip) wire, jointing materials and painting with 2 (two) coats of bituminous paint
Cutting cornices/ steps etc. including cutting recess in buildings etc. & supply & fixing 15 mm bore (ISI-Medium) GI pipe protection as below and mending good damages to the building works:Length upto 0.5 Mtr
Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage, for LC installation, per storey of building per vertical run
Excavation of soil for installation of Earth Electrode and filling & ramming. For Morrum Soil
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By ISI-Medium GI pipe
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe
Extra for treatment of soil by using salt & charcoal or coke for plate electrode
Supply, installation, testing and commissioning of LED illuminated 18’ x 4’ x 3” size sign board made of 1” x1” Iron hollow square bar with sufficient support bar in between the structure and fitted in wall with L channel and angle iron at the front side of the building. Thickness of the board in four side including 3’’ back side of the board should be covered with same ACP sheet and back portion of the board should be covered with 20 swg aluminum sheet to resist unwanted water seepage. 3 mm ACP of blue colour in the front of the structure and milky white 2.0” projected laser cut male and female acrylic letter will be fixed at the top of the ACP sheet with dark colour of acrylic sheet in side of male part to resist unwanted illumination from side of the letter. Female letter will consist of 1.5 watt sufficient Nos of water resist outdoor type LED module (make Bajaj / GE/Samsong) including supply and fixing controller in MS box outside of the structure.LED should cool milky white in colour, minimum 10000 burning hours, should have similar intensity at every point on the board, and should operate satisfactory up to 50 degree centigrade. Acrylic letter will be fixed on ACP base with such space so that all letters may read clearly from sufficient distance the four edges of the Boards should be fixed 40mmx40mm angle sheet channel with necessary steel screw .The cost including carrying (from companies work shop to Lalbagh) and scaffolding charges(for 4 storied building) and painting with 2 coat of RO primer and one coat of synthetic enamel paint. The letter of following inscription below as per direction of EIC:- Tentative matter & final matter willbe approved by authority.
Supply, Installation, Testing and commissioning of LED Illumination sign board fabricated by 12' x 4' (ft) x 6" (inch) depth ACP box supported with 1"x1" MS hollow square pipe or Aluminium Hollow square pipe of 18 swg. All around. The 3 mm ACO facial should be provide 3d with Laser cutting 6 mm laser cut Acrylic letters out of which 5 mm rising and border line of the front side shold with cover 1" Alluminium channel as per the direction of EIC. The sign board should be glow by 1.5 W LED module cool white in colour including 12 V 250 W power supply. Back side of the board should be covered with 26 swg GI sheet to protect rain water. The sign board should be fixed at the wall by using nut, bolt, washers etc. after making MS structure and grouting the same at wall and mending good the damages as per direction of EIC. The cost of transportation and scaffolding charges are included. inscription of the sign board should be as per direction of authority and as per direction of EIC.
Supplying, fabrication & installation of 12"x12" Hollow MS bar structure by welding 4 nos 50x50x5 mm thick angle iron pillar(2 nos) for resting 16ftx4ft Glow Sign Board to a height of 6mtr, consisting of 1"x1" hollow bar interconnecting each other of 4 Nos. angle iron to the requisite height to be install on 14"x14"x10mm base plate heighted by 4ft 25mm dia. foundation build up to 4ft from ground level and cement concreting at a proportion of 0.6x0.6x.45m each made by CC(4:2:1) including plasting and net cement finish asso mending good the damages and top of the pillar welded by 12"x12"x10mm base plate to rest the sign board at a gape of 4mtr of 2 pillar.(390kg iron for 2 nos pillar)
Wiring with 3X 1.5 Sqmm PVC copper wire in 13mm dia polythene pipe from loop box to LED fitting. (average run 7mt)
Supply and installation of 6 Mtrs. long G.I.octagonal pole with single arm including 01 no. 230/415V, 6A, C-Curve [Legrand Make] SP MCB on DIN rail and 4 pole connector and One nos. G.I. Arm bracket as per dimension-Top dia -70mm, bottom dia-130mm section-1 length 6000mm, thick-3mm blank plate 225x225x6mm PCD-225mm incl. foundation accessories (Make-Utkarsh/Bansal/Skipper /C.G./As per Choice of EIC). it required, to withstand wind speed upto 50m/sec etc. complete with cap etc. on top of CC foundation with help of 4nos 24inch long 20mm dia GI nut- bolt. CC foundation dimension Size 0.6x0.6x1.70 mts (Proportion 6:3:2)with hard jhama metal/Stone chips including CC (6:3:2) muffing 0.30 mts. above ground level including 3 mm thick neat cemented finish and GI earth bolt after making drilled holes etc. on pole including Supply and laying two nos. 25mm dia 1.5 mtr long Polythene pipe/suction pipe for cable entry including filling up the excavated earth pit with shifted soil and ramming properly as per instruction of EIC.
Excavation of soil for installation of Earth Electrode and filling & ramming. For Morrum Soil. [ 1(b)/G-1 ]
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:By TATA-Medium GI pipe. [ 2(a)/G-1 ]
Connecting the equipments to earth busbar including S & F 8 SWG GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages [ 5a(iii)/G-2 ]
MODERN ENGINEERING ENTERPRISE
RIK ENTERPRISE
B M ELECTRIC
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .