Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.6 LAccepted-AOC 02 PADRI SHIV NAGAR SHIV NAGAR MAHARAJGANJ UTTAR PRADESH 273303 | MAHARAJGANJ | UTTAR PRADESH | 273303 | L1 | Accepted-AOC Being overall reasonable | |
| 2 | L2₹30.8 L+₹2.1 L (7.48%)Rejected-Finance OFFICE NO 101 MALAN PLAZA NEXT TO ESSAR PETROL PUMP NEAR GODAMBLE CORNER RAHATNI PIMPRI DP ROAD RAHATANI PUNE 411 017 | PUNE | PUNE | MAHARASHTRA | 411017 | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹33.5 L+₹4.8 L (16.9%)Rejected-Finance | L3 | Rejected-Finance Not lowest bidder | |
| 4 | L4₹34.7 L+₹6.1 L (21.3%)Rejected-Finance | L4 | Rejected-Finance Not lowest bidder | |
| 5 | L5₹37.2 L+₹8.6 L (30.0%)Rejected-Finance FLAT NO S 2 SHRI CHINTAMANI S NO 1 1148 MAHAJAN PETH MODEL COLONY SHIVAJI NAGAR PUNE 411016 | PUNE | PUNE | MAHARASHTRA | 411016 | L5 | Rejected-Finance Not lowest bidder |
Tender Value
₹41.0 L
EMD Value
₹81,920
Closing Date
20 Feb 2021, 6:00 pmClosed
GE CENTRAL KIRKEE
GE CENTRAL KIRKEE RANGE HILLS ROAD PUNE-411003
MAINT RENEWAL AND REP OF INTERNAL ELECTRIFICATION INCL ALL INTERNAL ACESSORIES SUBMAIN WIRING FAN AND GEYSER OF MD ACCN OTM AND SINGLE LIVING ACCN OF OFFICER JCOS AND OR AT TBI AND DEPOT BN AT BEG CENTRE UNDER AGE EMI IN GE C KKE
2021_MES_415524_1
8444/E8 OF 2020-2021
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
KIRKEE
AS PER NIT
7 documents required · 7 mandatory
₹500
Yes
GE CENTRAL KIRKEE
₹81,920
Yes
25 Mar 2021
23 Jan 2021
22 Feb 2021
23 Jan 2021
20 Feb 2021
8 Feb 2021
23 Jan 2021 - 6 Feb 2021
Amount
M & L for surface point wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn in and including PVC casing caping of required size with all fittings and accessories alongwith one single core green colour PVC insulated 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly for one light point or one fan point or one call bell point controlled by one, one way switch including PVC switch board of required size or 3mm thick hylam sheet screwed with 04 nos cadmium coated screws & cup washer on existing MS concealled box for mounting of switch, regulators or bell push and casing caping terminal box for mounting ceiling rose/ holders etc incl dismentling taking down old unserviceable point wiring and making good to disturbed surfaces all as specified and directed.
M & L for surface point wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn in and including PVC casing caping of required size with all fittings and accessories alongwith one single core green colour PVC insulated 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly for one 5 amps socket point independent including PVC switch board of required size or 3mm thick hylam sheet screwed with 04 nos cadmium coated screws & cup washer on existing MS concealled box for mounting of switch, socket incl dismentling taking down old unserviceable point wiring and making good to disturbed surfaces all as specified and directed.
M & L for surface point wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn in and including PVC casing caping of required size with all fittings and accessories alongwith one single core green colour PVC insulated 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly for one 5 amps socket point on same board with other switches incl dismentling taking down old unserviceable point wiring and making good to disturbed surfaces all as specified and directed.
M & L for surface point wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn in and including PVC casing caping of required size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly for one two way light point controlled by two, two way switch including PVC switch board of required size or 3mm thick hylam sheet screwed with 04 nos cadmium coated screws & cup washer on existing MS concealled box for mounting of switch etc incl dismentling taking down old unserviceable point wiring and making good to disturbed surfaces all as specified and directed.
M & L for surface point wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 2.5 sqmm (Nominal area) drawn in and including PVC casing caping of required size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 2.5 sqmm as earth lead and connected to earth dolly for one 16amps socket (Power) point independent including PVC switch board of required size or 3mm thick hylam sheet screwed with 04 nos cadmium coated screws & cup washer on existing MS concealled box for mounting of switch, socket all as specified and directed.
M & L for surface submain wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn through in and including PVC casing caping/PVC conduit size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly incl dismentling taking down old unserviceable wiring and making good to disturbed surfaces all as specified and directed. NOTE: (a) Two run of cable with one run of earth wire and one run of casing capping/conduit will be measured as one length.
M & L for surface submain wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 2.5 sqmm (Nominal area) drawn through in and including PVC casing caping/PVC conduit size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 2.5 sqmm as earth lead and connected to earth dolly incl dismentling taking down old unserviceable wiring and making good to disturbed surfaces all as specified and directed. NOTE: (a) Two run of cable with one run of earth wire and one run of casing capping/conduit will be measured as one length.
M & L for surface sub main wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 6.0 sqmm (Nominal area) drawn through in and including PVC casing caping/PVC conduit size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 6.0 sqmm as earth lead and connected to earth dolly incl dismentling taking down old unserviceable wiring and making good to disturbed surfaces all as specified and directed. NOTE: (a)Two run of cable with one run of earth wire and one run of casing capping/conduit will be measured as one length.
M & L for surface sub main wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 10.0 sqmm (Nominal area) drawn through in and including PVC casing caping/PVC conduit size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 10.0 sqmm as earth lead and connected to earth dolly incl dismentling taking down old unserviceable wiring and making good to disturbed surfaces all as specified and directed. NOTE: (a)Two run of cable with one run of earth wire and one run of casing capping/conduit will be measured as one length.
M&L including fixing 5 Amp switch piano type single pole one way incl dismentling taking down unsv one all as specified and as directed
M&L including fixing 5 Amp switch piano type single pole two way incl dismentling taking down unsv one all as specified and as directed
M&L including fixing bell push piano type one way 240 volt incl dismentling taking down unsv one . all as specified and as directed
M&L including fixing socket flush type 6 amps, 5 pin, 230v incl dismentling taking down unsv one all as specified and as directed
M&L including fixing switch socket combination multipurpose 2-in-1 flush type 3 pin 16 amps and 3 pin 6 amps, 230v incl dismentling taking down unsv one all as specified and as directed
M&L including fixing lamp Holder insulated body with back plate for batten fitting incl dismentling taking down unsv one all as specified and as directed
M&L including fixing LED lamp 12 watt, CDL, B-22 cap, (Pin type), 230V, PF-0.95 (min) incl dismentling taking out unsv CFL. Make-HPL/Havells/CG/Bajaj/ Philips
M&L including fixing LED lamp 3 watt, CDL, E-14 cap, (Small thread type), 230V, PF-0.95 (min) incl dismentling taking out unsv CFL. Make-HPL/Havells/CG/Bajaj/ Philips
M&L including fixing ceiling rose surface Bakelite three terminal incl taking down unsv one all as specified and as directed.
M&L including fixing call bell electric, ding dong, AC 240 volt, 50 HZ. incl taking down unsv one all as specified and as directed.
M&L including fixing flush type electronic fan regulator with 5 step type,120 W, AC 240 Volts, 50 Hz incl dismentling taking down unsv one all as specified and as directed.
M&L including fixing MCB, Single Pole, 6 to 32 amps, 240 Volts, 10 KA breaking cap, ‘’C” curve incl dismentling taking down unsv one all as specified and directed. MAKE- Cat Part No- 4085-87 to 4085-95 of Legrand or equivalent of Schneider/ABB.
M&L including fixing MCB, Double Pole, 6 to 32 amps, 415 Volts, 10 KA breaking cap, ‘’C” curve incl dismentling taking down unsv one all as specified and directed. MAKE- Cat Part No- 4086-28 to 4086-36 of Legrand or equivalent of Schneider/ABB
M&L including fixing MCB, Four Pole, 40 to 63 amps, 415 Volts incl dismentling taking down unsv one all as specified and directed. MAKE- Cat Part No- 4087-00 to 4087-02 of Legrand or equivalent of Schneider/ABB
M&L including fixing Sheet metal enclosure two way, IP-30 incl dismentling taking down unsv one all as specified and directed. MAKE- Cat Part No-5077 91 to -5077 93 of Legrand or equivalent of Schneider/ABB.
M&L including fixing MCB distribution board, Double door, metal enclosure, SPN, 230 Volts, 4 way incl dismentling taking down unsv one all as specified and directed. MAKE- Cat Part No- 5076 10 of Legrand or equivalent of Schneider/ABB
M&L including fixing MCB distribution board, Double door, metal enclosure, SPN, 230 Volts, 8 way incl dismentling taking down unsv one all as specified and directed. MAKE- Cat Part No- 5076 11 of Legrand or equivalent of Schneider/ABB
M&L including fixing MCB distribution board, Double door, metal enclosure, SPN, 230 Volts,12 way incl dismentling taking down unsv one all as specified and directed. MAKE- Cat Part No- 5076 12 of Legrand or equivalent of Schneider/ABB
M&L including fixing MCB distribution board, Double door, metal enclosure, TPN, 415 Volts, 4 way incl dismentling taking down unsv one all as specified and directed. MAKE- Cat Part No- 5076-70 of Legrand or equivalent of Schneider/ABB
M&L including fixing Vertical MCB distribution board, as MCB incomer, Double door, metal enclosure, TPN, 415 Volts, 4 way incl dismentling taking down unsv one all as specified and directed. MAKE- Cat Part No- 5077-25 of Legrand or equivalent of Schneider/ABB
M&L including fixing Vertical MCB distribution board, as MCCB incomer, Double door, metal enclosure, TPN, 415 Volts, 4 way incl dismentling taking down unsv one all as specified and directed. MAKE- Cat Part No-507745 of Legrand or equivalent of Schneider/ABB
M&L including fixing Metal plug and socket board with MCB SP 20 amp, 16 KA incl dismentling taking down unsv one all as specified and directed. MAKE- Cat Part No- 5078 11 of Legrand or equivalent of Schneider/ABB
M&L including fixing PVC rectangular switch board of size 300mmx 250mm x50mm incl necessary cutting slots for mounting switch sockets etc incl dismentling taking down unsv one all as specified and directed. MAKE- Presto Teak/Press Fit/Plaza.
M&L including fixing PVC rectangular switch board of size 200mmx 150mm x50mm incl necessary cutting slots for mounting switch sockets etc incl dismentling taking down unsv one all as specified and directed. MAKE- Presto Teak/Press Fit/Plaza.
M&L including fixing PVC rectangular switch board of size 175mmx 100mm x50mm incl necessary cutting slots for mounting switch sockets etc incl dismentling taking down unsv one all as specified and directed. MAKE- Presto Teak/Press Fit/Plaza.
M&L including fixing PVC rectangular switch board of size 100mmx 100mm x50mm incl necessary cutting slots for mounting switch sockets etc incl dismentling taking down unsv one all as specified and directed. MAKE- Presto Teak/Press Fit/Plaza.
M&L including fixing Hylam Sheet 3mm thick on existing concealled MS/CI ractangular or Squar or round box with 04 nos cadmium coated screws and cup washer incl cutting slots for mounting switch/socket/fan regulator/ batten holder etc incl dismentling taking down unsv one
M&L including fixing PL LED tube, 12 watt, 2 pin, 230V and incl dismentling taking out unsv CFL. Make-HPL/Havells/CG/Bajaj/ Philips.
M&L including fixing PL LED tube, 12 watt, 4 pin 230V, and incl dismentling taking out unsv CFL. Make-HPL/Havells/CG/Bajaj/ Philips.
M&L including fixing PL LED tube, 18 watt, 4 pin 230V and incl dismentling taking out unsv CFL. Make-HPL/Havells/CG/Bajaj/ Philips.
M&L including fixing round shaped recess mounted LED Flat panel down lighter, 12 watt (8"dia), suitable for POP celing complete with all fixing accessories and including connecting up to ceiling rose with 0.5 sqmm two core copper flexible conductor cable incl dismentling taking down unsv fitting any type all as specified and directed. Make-Havells , Cat Part No LHEAABP7L1W012or equivalent in Bajaj/Philips/HPL/Havells
M&L including fixing quare shaped shaped recess mounted LED Flat panel down lighter, 12 watt suitable for POP celing complete with all fixing accessories and including connecting up to ceiling rose with 0.5 sqmm two core copper flexible conductor cable incl dismentling taking down unsv fitting any type all as specified and directed. Make-Havells , Cat Part No LHEAABP7L1W012or equivalent in Bajaj/Philips/HPL/Havells
M&L including fixing Square shaped recess mounted LED slim Flat panel suitable for fixing in aluminium framed ceilling, 36 watt, 2'x2'size, complete with all accessories and including connecting up to ceiling rose with 0.5 sqmm two core copper flexible conductor cable incl dismentling taking down unsv fitting any type all as specified and directed. Make-CG, Cat Part No LCPL-36-CDL (2x2) (Aura) or equivalent in Bajaj/Philips/HPL/Havells
M&L including fixing LED tube 20 watt to existing fluorescent FTL (T-8) fitting surface mounted after taking downelectronic ballast, internal wiring and complete rewiring with 0.5 sqmm copper flexible conductor from connector block to one end of Bipi holder and including connecting up to ceiling rose with 0.5 sqmm two core flexible copper conductor cable all as specified and directed. Make-Cat Part No HLPLEDT8PCP20CW HPL or equivalemt in Bajaj/Philips/Crompton Greaves /Havells
M&L including fixing industrial box type LED Batten with CRCA body, pre coated with white and prewired suitable for LED tube 1x18/20 watt 4'long incl dismentling taking down unsv fitting any type all as specified and directed. Make-HPL, Cat Part No-HLPLEDT801WT or equivelent of Bajaj/Philips/CG/Havells
M&L including fixing LED battenfitting, 20 watt, CDL, 230 Volts, 4 feet long , complete with all accssories internally pre wired and including connecting up to ceiling rose with 0.5 sqmm twin core copper flexible conductor cable incl LED lamp and mounting casing box 2 nos incl dismentling taking down unsv fitting any type all as specified and directed. Make-HPL, Cat Part No HPLLEDT5PC20W or equivalemt in Bajaj/Philips/CG/Havells
M&L including fixing LED batten fitting, 2'long, 09 watt, 230 Volts , complete with all accssories internally pre wired and including connecting up to ceiling rose with 0.5 sqmm two core copper flexible conductor cable with mounting casing box 2 nos incl dismentling taking down unsv fitting any type all as specified and directed. Make-HPL Cat Part No-Neptune Gold, HLPT51509PCGCW or equivalemt in Bajaj/Philips/CG/Havells
M&L including fixing LED building security light 15 watt, 230V complete with all accessories and including connecting up to ceiling rose with 0.5 sqmm three core copper flexible conductor cable, One GI medium grade 20mm dia bracket of total length 50 cm and fixed to wall with 2 Nos MS Clamp and fastener incl dismentling taking down unsv fitting any type all as specified and directed. Make-CG, Cat Part No LSTS-15-CDL or equivalent in Bajaj/Philips/HPL/Havells
REPAIR TO CEILING FANS WITH FOLLOWING ITEMS OF WORK :- M&L for Rewinding of Ceiling fan 1200 mm sweep after dismenting complete motor assy, bearings, bushings, removal of burnt copper wire, cleaning of core, inserting proper insulating paper in slots, winding with and as per existing size/turn of super enamelled copper wire, heating, vernishing, replacement of unsv bearings / bushings, assemble of rotor and stator unit with capacitor, connecting wire, down rod, blades and testing complete. Note: 1. Contractor will collect fans from the complaint cells of specified area and bring back to complaint cell after repair. Cost of transportation will be inclusive of quoted rate. 2. Spares require for replacement such as bearing, Bushing, capacitor shall be measured and paid separately as supply & Fixing only. 3. Cost of Connector bock and capacitor holder shall be inclusive of the quoted rate.
All as per item No- 46 here-in-above but for Exhaust fan 450 mm sweep industrial type.
All as per item No- 46 here-in-above but for Exhaust fan 300/380 mm sweep industrial type.
All as per item No- 46 here-in-above but for Exhaust fan 225/250/300 mm sweep domestic type.
All as per item No- 46 here-in-above but for wall fan
M&L including fixing ball bearing No 6201/6202/6203/6204 of SKF/Tata/NBC.
M&L including fixing G.M. Bush bearing for ceiling fan as per existing pattern.
M&L including fixing capacitor AC for 230 volts 50 Hz of capacity 2.0/2.25/2.5 Mfd.
M&L including fixingcapacitor AC for 230 volts 50 Hz of capacity 3.15 Mfd.
M&L including fixing capacitor AC for 230 volts 50 Hz of capacity 4.0 Mfd.
Painting of ceiling fan 1200/1400 mm including scrapping , cleaning & revmoving dust from the blade and body and applying two coat of enamel paint over, one coat of primer all as directed and specified.
M&L including fixing exhaust fan 300 mm PVC body, 230 vol incl dismentling taking down unsv fitting any type all as specified and directed. Make Bajaj or equivalent
M&L including fixing PVC insulated PVC sheathed copper flexiable wire multistrand 4sqmm 3 core, ISI marked
M&L including fixing in repair thermostat suitable for geysers 25 Ltrs to 50 Ltrs Capacity. Make- Bajaj/Venus/Recold all as specified and directed.
M&L including fixing in repair fusible plug suitable for 25 and 50 ltrs capacity Geysers all as specified and directed.
M&L including fixingin repair heating element round/triangular bas, push type or thread type including rubber washers for 1.5/2.0 KW all as specified and directed.
M&L including fixing in repair innner water container made of SS, vertical or horizontal type for 25/50 ltr capacity gyser all as specified and directed.
M&L including fixing in repair of aparatus plate suitable for vertical/horizintal type Geyser 25 or 50 ltr cap all as specified and directed.
M&L including fixing in repair heavy duty PVC connections pipe with brass hexagonal adoptersat both side 15mm dia and 450mm long for hot /cold water all as specified and directed.
M&L for testing of earth resistance value of building earth for electrical purpose, using analog/digital earth resistance tester by suitably inserting spikes as per norms and recording earth resistance value of building in presence of MES Rep and User rep and submission of recorded value in form of hard copy duly signed all as specified and directed.
M & L for Earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 3 mtr long buried directly and vertically in ground with top edge at ground level after making bore hole of size not less than 300 mm dia and 3.0 Mtr long using suitable mechanical drilling rig (for drilling near the specified bldg), connected with galvanised steel earthing lead of 4mm dia all as shown in Plate No-2, connected to the earthing test point, concrete pit in PCC 1:3:6 type C-2with RCC precast pit cover slab 400mmx400mmx80mm with handle for lifting made out of 8mm dia MS rod, funnel, wiremesh, 15 mm dia light grade GI tubing for protection of GI wire 4mm dia, charcoal and salt in alternate 150mm thick layers around GI earth pipe, including necessary returning filling in & removal all as specified or indicated in SSR Part-I, including testing to achieve earth resistance value as per IS specification on completion.
M/S. Niksun Electro-Infra Private Limited
M/S VR Construction Services
PURVA ELECTRICALS AND ENGINEERS
Horizon Construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .