Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.5 LAccepted-AOC 1 225 5 6 SADAR BAZAR DELHI CANTT 110010 | NEW DELHI | DELHI | 110010 | ₹35.5 L Quoted ₹17.9 L | L1 | Accepted-AOC LOWEST |
| 2 | L2₹37.8 L+₹20.0 L (111.8%)Rejected-Finance 205 PARSHAV VIHAR PLOT NO 50 IP EXTN PARPARGANJ DELHI 110092 | EAST | DELHI | 110092 | ₹37.8 L+₹20.0 L (111.8%) | L2 | Rejected-Finance OTHER THAN LOWEST |
| 3 | L3₹38.7 L+₹20.8 L (116.6%)Rejected-Finance A 303 VEENA CGHS LTD PLOT NO 5D SECTOR 22 DWARKA NEW DELHI 110077 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110077 | ₹38.7 L+₹20.8 L (116.6%) | L3 | Rejected-Finance OTHER THAN LOWEST |
| 4 | L4₹44.9 L+₹27.0 L (151.3%)Rejected-Finance | ₹44.9 L+₹27.0 L (151.3%) | L4 | Rejected-Finance OTHER THAN LOWEST |
| 5 | L5₹46.0 L+₹28.1 L (157.4%)Rejected-Finance | ₹46.0 L+₹28.1 L (157.4%) | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹49.9 L
EMD Value
₹99,880
Closing Date
8 Feb 2020, 6:00 pmClosed
GE E/M BASE HOSP DELHI CANTT
GE E/M BASE HOSP DELHI CANTT
REPAIR/REPLACEMENT OF UNSV FOR DG SETS, OVERHAULLING OF DG SETS ENGINE, REPAIRING OF GOOD LIFT AND CONNECTED MISC E/M WORKS UNDER GE E/M BASE HOSPITAL DELHI CANTT-10
2019_MES_306218_2
GE/BH-47/2019-20
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE E/M BASE HOSP DELHI CANTT
Meeting enlistment criteria of MES with regard to having satisfactory completed requisite value works annual turnover, working capital, fixed assets. No recovery outstanding in any govt dept security clearance etc.
7 documents required · 7 mandatory
₹500
GE E/M BASE HOSP DELHI CANTT
₹99,880
Yes
13 Mar 2020
24 Jan 2020
10 Feb 2020
24 Jan 2020
8 Feb 2020
1 Feb 2020
Amount
M&L for disconnecting power supply from HT load break switch of capacity 400 Amps for repair works, complete servicing of the same through de-carbonising, cleaning the isolating contacts, lubricating moving part, cleaning with CRC, removing dust particles from bus bar chamber, spout gear mechanism and moving parts, checking proper operation of trolley all as directed and testing, and putting on load complete all as specified and directed.
Disconnecting LT supply and servicing of Air circuit breaker of capacity 630 to 1500 Amps and rating 1100 Volts by cleaning and de-carbonising the contacts point, cleaning with CRC, checking proper operating of moving parts, repair to charge spring mechanism, checking of AC supply, parts tightening all nuts and bolts of components, lubricating moving parts with petroleum jelly as directed and testing complete and keeping in on load complete all as specified and directed.
Repairs/maintenance of 11KV HT VCB Panel including bus coupler of any type, size and capacity complete including the following complete all as specified and directed:- (a) Taking out 11KV HT VCB of 400/630/800 Amps rating trolley from HT Panel after switching off electric supply, Checking of mechanical system for proper functioning of upward/downward movement of HT VCB trolley including opening the VCB & checking the quality of insulating, Cleaning & servicing the fixed/ moving contact & blowing out dust and applying the proper lubrication/ greasing and reassembling the VCB connection to HT panel complete. (b) Taking out all types of relay from HT11KV VCB panel and cleaning the contact and adjust the contact. Calibration all type of relay i.e.. master tripping relay, earth fault tripping relay, over current, over voltage relay, circuit supervision relay etc through relay testing kit & proper plug setting as per reqd load & time delay and fixing the relay set in HT panels complete.
S&F in replacement PT unit three phase three limb upto 11 KV draw out type single ratio having primary 11 KV & secondary voltage 110 volts 200 VA class I, including necessary bus bar connection & wiring for metering after disconnecting of HT supply from HT VCB of capacity 100 to 630 Amps for repair works, taking out unserviceable PT unit complete all as specified and directed.
Supply, installation and commissioning in replacement HT 11 KV current transformer double wound cast resin type with sprout of ratio 600-400/5+5, 300-150/5+5, 200-100/5+5 & 60/5+5 amps complete all as specified and directed.
S&F in replacement fixed contact block complete suitable for 11 KV HT VCB of capacity 400/630/800/1250 Amps, complete all as specified and directed.
S&F in replacement moving contact block complete suitable for 11 KV HT VCB of capacity 800 Amps complete all as specified and directed.
S&F in replacement tripping coil assembly for 110/50/24 Volt DC for 11 KV HT VCB of capacity 800 Amps capacity complete all as specified and directed.
S & F in replacement closing coil assembly 110/50/24 volts DC for 11 KV HT VCB of capacity 400/630/800/1250 Amps capacity complete all as specified and directed.
S & F in replacement motor & gear assembly 220 Volt AC motorised mechanism of V.C.B 12KV upto 1250 Amps capacity including testing & putting on load complete all as specified & directed.
S & F in replacement auxiliary switch (7 No + 7NC) for HT V.C.B 12KV 400/630/800 Amps capacity complete all as specified & directed.
M&L for carrying out load balance distribution on LT side by checking the existing load on the feeder (3 phase, 4 wire system) and accordingly shifting & connecting service cables to another phase conductor in accordance with balancing of Electric load complete all as specified & directed. Contractor shall submit reports before load balance and after load balance as per format given by the department complete all as specified & directed.
S&F in replacement Male Contacts for air break switch contact complete all as specified and directed.
S&F in replacement Female Contacts for air break switch contact complete all as specified and directed.
S&F in replacement post insulator for air break switch with metal part suitable for HT 11KV confirming to IS 5572-1972 complete all as specified and directed.
Maintenance & repairing of 1.1 KV LT ACB panel, dusting, oiling if any, setting of over current and earth fault relay setting all as specified laid and servicing like all mechanical function including replacement of no volt coil tripping device complete all as specified and directed.
M&L for pipe earthing (PIP) comprising of GI 80mm Dia x 3 Mtr with one bag of BFC (50 Kg) as per IS 3043-1987 tubing filled with jelly earthing compound duly inserted in soil boring of 100mm bore filled with back filled compound including fibre chamber cover 1x1feet openable type complete all as specified and directed. Note: On testing after completion, if the earth resistance < 2 Ohms is not obtain earthing will be rejuvenated at no extra cost till the desired earth resistance is obtain.
S & F in repair 630 Amp MCCB 4 Pole, 50 KA including necessary sheet metal enclosure of size 0.15 x 0.125 x 0.125cm made out of 1.6 mm MS sheet duly powder coated with necessary copper cable for & flexible PVC conduit for internal connection for distribution complete all as specified and directed. Make- L&T/Legrand/Havells
All as per item No. 18 here in before but 400 Amp MCCB TPN 35 KA complete all as specified and directed. Make- L&T/Legrand/Havells
S&F in repair MCCB 4 pole, 415V adjustable, 250 Amps with breaking capacity of 35KVA including cable connections in existing panel complete all as specified and directed. Make- L&T/Legrand/Havells
All as per item No.20 here in before but 200 Amps, breaking capacity of 35 KA complete all as specified and directed. Make- L&T/Legrand/Havells
All as per item No. 20 here in before but 100 Amps adjustable thermal & adjustable magnetic setting ( breaking capacity of 35 KA complete all as specified and directed. Make- L&T/Legrand/Havells
Labour only for re-routing of LT UG cable, XLPE insulated (ISI Marked), PVC sheathed, heavy duty, 1100 volts grade with aluminium multi stranded conductor of any size any core etc including taking down UG cable from existing trenches and relaying in new route complete all as specified and directed. Note:- (i) Necessary Excavation, earthwork, sand cushioning & brick protection shall be measured & paid separately. (ii) Old serviceable bricks shall be kept in good condition for reuse at site.
S & F cable jointing kit for 11 KV (earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm complete all as specified and directed.
M & L for testing earthing pit with digital type earth tester at different locations of BHDC up to the entire satisfaction of Ward Master of BHDC & submitting the earth result to JE E&M /AGE E&M and pouring of water in Earthing pit complete all as specified and directed.
Demolition of the broken earth pit chamber and construction of new earth pit chamber including and PCC chamber cover complete as per SSR Pt -I of 2010 including new wire mesh funnel complete all as specified and directed.
M & L for removing the existing damaged test point terminal block and replacing the same with new test point terminal block made out of gun metal or phosphorus bronze of size 75 x 75 x 25mm drilled and screwed including 3 hole 8mm dia 25mm long hexagonal head with nut and washers etc complete all as specified and directed.
M & L for recharging of earthing including repair of PCC pit, jointing of GI wire/GI strip and replacement of MS earth pit cover including adapted following procedure during recharging:-
(a) Excavating earth pit up to 3 ft depth and 3 ft radius around the pit, without damaging existing electrode and keeping the excavated soil near to the pit to reuse for refilling along with the chemicals.
(b) Each earth pit requires 25 Kg (appx) of chemical as per distribution mentioned below. Prepare the chemical mixture for the earth pit and keep it near to the pit for filling.
(i) Magnesium : 10 Kg
(ii) Salt : 10 Kg
(iii) Charcoal: 5 Kg
(c) Fill back chemical mixture prepared in above step and loose soil at alternate layers of 15cm. The top most layer must be of soil (excavated soil) and shall be of minimum 2 ft depth to avoid erosion of chemicals.
(d) Fill the pit with water for 3-4 hrs continuously for dissipation of the chemical. The same procedure shall be followed for next seven days for even distribution of the chemical around the electrode.
(e) Check the connection between electrode and copper strip. All rusted nut and bolts shall be replaced with new one and tightened. Use contact cleaner to clean the connection point. Apply petroleum jelly to the connection point to avoid rusting and moisture accumulation.
(f) Inspect the copper strip running between the earth pit and equipment room. All connection point shall be inspected for tightness and rusting.
(g) Check termination of equipment earth cable on the junction box. All loose connection shall be tightened. Check for the availability of thimble and if it is broken replace it with spare.
Taking down old unserviceable cable from trenches/ walls/pipes/poles etc complete of size upto 10 Sqmm to 25sqmm and also removing old connection of cable complete all as specified and directed.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth and getting out in soft/loose soil complete all as specified and directed .
Supply and laying clean dry sand for cable cushion including gently punning complete all as specified and as directed. Note: Punned thickness of sand shall be measured for payment purpose.
M&L for burnt brick sub class ‘B’ laid in trenches abutting each other width equal to length of bricks all as specified and as directed.
Laying only old serviceable bricks (Obtained from item Nos 23 & 29), laid in trenches abutting each other width equal to length of bricks complete all as specified and as directed.
Returning, filling in trenches including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each layer complete all as specified and as directed.
Removing the surplus soil to a distance not exceeding 50 mtrs and depositing where directed at level not exc 1.5 mtr above the starting point complete all as specified and directed.
S&F in repair feeder pillar box, outdoor type, double door, made out of 3.15 mm thick CRCA sheet with of 40x40x5mm angle iron frame, upto 1.2 mtr length from ground level duly powder coated of size 900x600x350mm including necessary PCC & connection & duly prewired & comprising the following Accessories complete all as specified and directed:- Make- Conelec/BBN Energy/Universal Switch Gear/Shalabh
(i) MCCB 100 Amp (AC 415), TPN 16 KA - 01No (incoming) (ii) 63 Amp MCB, TPN,10 KA - 02 Nos (Outgoing) (iii) 32 Amp SPN MCB 10KA - 02 Nos (iv) Copper bus bar 200 Amp -01 set (v) Button Holder - 01 No (vi) Two-in one Socket - 02 Nos (vii) One way Switch - 03 Nos (viii) 5/15 Amp Socket - 04 No (ix) 15 Amp Switch -04 No (x) Three pole and neutral enclosure with two pin and earth plug and socket complete with one TPN MCB 32 Amps - 03 Nos
S& F in repair set of Copper lead (Wire) 2.50 mtr long with clamp for 12Volts 180 AH Batteries complete all as specified and directed.
S&F in repair Lead Acid Battery 12Volts, 180AH suitable for DG set complete all as specified and directed. Make:- EXIDE/Amaron/SUKAM/Luminous
Dismantling following size cable armoured/unarmoured cutting burnt damaged portion of cable and replacement of lugs heavy duty Aluminium/copper and connecting in position including tighting cable gland including necessary excavation/earth work complete all as specified and directed.
(a) Cable of size 2/4 core 16 Sqmm to 3.5 core 50 Sqmm
(b) Cable of size 3.5 core 70 Sqmm to 3.5 core 95 Sqmm
M&L cable jointing kit for 1.1 KV grade cable for straight through joint complete with jointing material (Epoxy based) and accessories suitable for 3.5 to 4 core XLPE armoured AL conductor cable of size 70 to 120 Sqmm complete all as specified and directed.
Maintenance and repairing of 1.1 KV LT ACB Panel, Dusting oiling if any setting of over current and earth fault relay all as specifications laid and servicing like all mechanical function including replacement of no volt coil tripping device complete all as specified and directed.
Disconnection terminal of LT cable and locating pin point fault in LT cable 1100V grade of any size including to & pro hire charge of special T&P complete all as specified and directed.
Disconnection terminal of HT cable and locating pin point fault in HT cable 11000V grade of any size including to & pro hire charge of special T&P complete all as specified and directed.
Supply, installation, testing and commissioning LT outdoor switch gear panel board manufactured by CPRI approved factory, platform mounted, totally enclosed dust and vermin proof, size 1800 x 1500 x 450 mm, made out of 50 x 50 x 6 mm MS angle iron frame and CRCA sheet of not less than 3.15 mm thick and legs of size 0.5m long as per IS 5039, cubical type front and rear side openable, provision of air vent and provision of cable alley with 3000 Amps Aluminium rated bus bar for phases and 400 Amps rated bus bar for neutral, duly painted with powder coated paint of approved shade after seven tank treatment process. The panel shall be suitable for 415 Volts, 50 Hz, 3 Phase, 4 wire system and bus bars fixed on porcelain or PVC insulators, thimbles, glands of brass and shall be complete including necessary earth work and PCC foundation complete all as required with following accessories including taking down old LT panel board complete all as specified and directed: - Make-Conelec/BBN Energy/Universal Switch Gear/Shalabh (a) Incomming 400 A 36 KA MCCB Microprocessor Based release for LSIG protection with ROH, AUX, Trip Contact. (b) Metering and Indication (i) Digital Multifunction Meter with RS 485 Port, CI -1 (ii) CT for Meter CI -1.0,15VA 400/5A-03 Nos (iii) RYB phase Indication light (iv) On /off/trip indication light - ACB (v) Control MCB SP (c) Out Goings - (i) TPN MCCB Thermal Magnetic based release for (O/L &S/C) protection with ROH -200A, 25 KA -01 Nos (ii)TPN MCCB Thermal Magnetic based release for (O/L &S/C) protection with ROH -100A,25 KA -05(iii) TPN MCCB Thermal Magnetic based release for (O/L &S/C) protection with ROH -63A, 25 KA -02 (iv) Aluminium Bus Bar - 600 Amp Make of MCCBs - ABB/Siemens Schneider/L&T
Supply, installation, testing and commissioning LT outdoor switch gear panel board manufactured by CPRI approved factory, platform mounted, totally enclosed, dust and vermin proof, Size - 3700x1800x1000mm, made out of 50 x 50 x 6 mm thick MS angle iron frame and CRCA sheet of thickness not less than 3.15 mm and legs of size 0.5m long as per IS 5039, cubical type, front and rear side openable, provision of air vent and provision of cable alloy with 3000 Amps Aluminium rated bus bar for phases and 400 Amps rated bus bar for neutral duly painted with powder coated paint of approved shade after seven tank treatment process. The panel shall be suitable for 415 Volts, 50 Hz 3 Phase, 4 wire system and bus bars fixed on porcelain or PVC insulators, thimbles, glands of brass and shall be complete including necessary earth work and PCC foundation complete all as required with following accessories including taking down old LT panel board complete all as specified and directed: - Make- Conelec/BBN Energy/Universal Switch Gear/Shalabh (a) Incomming (i) EDO 2000 A 50 KA ACB Microprocessor Based release for LSIG protection and UVR (ii) TNC Switch (b) Metering and Indication (i) Digital Multifunction Meter with RS 485 Port, CI -1 (ii) CT for Meter CI -1.0,15VA (iii) RYB phase Indication light (iv) On /off/trip indication light-ACB (v) Control MCB SP (c) Out Goings - (i) TPN MCCB Micro processor based release for (O/L &S/C) protection with ROH -800A,50 KA -02 Nos (ii)TPN MCCB Micro processor based release for (O/L &S/C) protection with ROH -630A,50 KA -01(iii) TPN MCCB Micro processor based release for (O/L &S/C) protection with ROH -400A, 50 KA -04 (iv) TPN MCCB Thermal magnetic based release for (O/L &S/C) protection with ROH -250A,50 KA -06 NOs (v) TPN MCCB Thermal magnetic based release for (O/L &S/C) protection with ROH -63A, 50 KA -02 Nos. (vi) Aluminium Bus Bar 3000 Amp. Make- Of MCCBs -ABB/Siemens Schneider/L&T
Supply & laying in repair XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 630 Sqmm single core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc including taking down old cable complete all as specified & directed.
S&F in repair On load change over switch of 800 Amp capacity, 4 pole by pass switch along with MS Enclosure made of 3.15 mm thick steel sheet Enclosure and extensible handle mounting stand made from 35 x 35 x 5mm thick MS channel, floor mounted and fixing in ground and necessary mounting accessories complete all as specified and directed. Make:- Havells Cat No IHCBFO0800 or equivalent model of L&T/ Schneider/Legrand
S&F in repair On load change over switch of 1000 Amp capacity, 4 pole by pass switch with MS Enclosure made of 3.15 mm thick steel sheet Enclosure and extensible handle mounting stand made from 35 x 35 x 5mm thick channel floor mounted and fixing in ground and necessary mounting accessories complete all as specified and directed. Make:- Havells Cat No IHCBFO1000 or equivalent model of L&T/ Schneider/Legrand
Supply, Design, fabrication, erection and commissioning of Boom Barrier for 6000 mm opening with remote receive (LED illumination, warning plate push button, receiver, remote control including wiring complete, opening time 06 sec, boom type straight, 90 degree, boom length 6 mtrs, 220 V , motor power 100 watt, working temp 35 degree, IP 54 Protection, remote control distance up to 100 feets, barrier dimension 55x80mm, manual release on power failure, left or right type as per site requirement, integration possible with car parking system equipments, Limit switch safety, radio frequency based remote control, motor cooling fan, solving the problem of over heat protection, boom with protection rubber band, complete all as specified and directed. Make- Perfect/Godrej/Rib/Gandhi Automation/Livfuture Note:- Civil Work required for installation of Barrier shall deemed to be inclusive in rate quoted by the contractor.
M&L for comprehensive maintenance of 02 Nos Motorized door complete all as specified and directed. Contract Details:- (i) Free maintenance and repair of Normal accessories (Spare Parts) - 02 Nos Doors. (ii) Preventive maintenance of all systems on quarterly basis and upkeep of log book. (iii) Attending all complaints within 24 working hours. (iv) Field service report will be maintained and submitted to the JE after expiry of every quarter. Note:- (a) The work is required to be completed within AMC. (b) The rates quoted by the contractor shall deemed to be inclusive of T&P etc (c) Major Spares Parts shall be measured and paid separately under respective item of this Schedule.
S&F in repair AC single phase 230 V induction motor for motorized door of carrying capacity 1600 kg to carry the load with safety sensor limit switches to ensure end stationing of the gate to safeguard over travelling and over loading of drives, controlling through remote and other connecting accessories and guide bar complete all as specified and directed.
M&L for comprehensive maintenance of 04 Nos sensor door complete all as specified and directed. Contract Details:- (i) Free maintenance and repair of Normal accessories (Spare Parts) .- 04 Nos Doors. (ii) Preventive maintenance of all systems on quarterly basis and upkeep of log book. (iii) Attending all complaints within 24 working hours. (iv) Field service report will be maintained and submitted to the JE after expiry of every quarter. Note:- (a) The work is required to be completed within AMC. (b) The rates quoted by the contractor shall deemed to be inclusive of T&P etc (c) Major Spares Part shall be measured and paid for separately under respective item of this Schedule as supply only.
Supply only Dorma Anti Jump Wheel suitable for sensor door complete all as specified and directed.
Supply only Dorma Main Roller suitable for sensor door complete all as specified and directed.
Supply only Radar suitable for sensor door complete all as specified and directed.
Supply only Motor Assembly suitable for sensor door complete all as specified and directed.
Supply only Control Unit Assembly suitable for sensor door complete all as specified and directed.
Supply only Torroidal Transformer suitable for sensor door complete all as specified and directed.
Supply only Timer Belt with Accessories suitable for sensor door complete all as specified and directed.
Supply, fixing, testing & commissioning Auto main failure (AMF) panel 15 SWG for 220 KVA DG Set Cubical consist of sheet steel enclosure of 2.00 mm thick, totally enclosed, dust proof, duly painted with powder coated, (shade No. 7032 Siemens gray) fully wired up and ready to connect load & control lines in, comprising the following accessories complete all as specified and directed. Make- Conelec/BBN Energy/Universal Switch Gear
(a) Under Voltage relay 415V AC for main - 01 No.
b) Under voltage relay 415 V AC for DG – 01 No.
c) AC Timer 230 Volt , 2 No. +2 NC - 01 No.
d) DC Timer 12/24 V - 01 No.
e) Engine Start relay 12/ 24 V- 01 No.
f) Control MCB SP 6 Amp. 230 V – 01 No.
g) Transformer 12 / 24 V – 01 No.
h) Rectifier suitable size – 01 No.
i) LED Indicating Light for Main & DG - 06 Nos.
j) LED Indicating Light for Main & Gen. ON – 02 Nos.
k) LED Indicating Light for battery Charger – 01 No.
n) CT Coil 500 / 5 - 06 Nos.
o) DC Volt Meter 15/30 V - 01 No.
p) DC Amp Meter 0-15 A. - 01 No.
q) Trickle / Boost switch – 01 No.
r) Auto / Manual Switch - 01 No.
s) Start & Stop Push Button - 02 Nos.
t) Frequency Meter – 01 No.
u) Power Contactor MNX 630 A 3 Pole 415V for DG. - 01 No.
v) Power Contactor MNX 630 A 3 Pole 415V for Main. - 01 No.
w) MCCB 400 A 35 KA 3 Pole - 02 Nos.
x) Control Relay - 01 Set.
y) Over Load Relay 2.5-4A. – 01 No.
z) Hooter 24 V DC - 01 No.
aa) C/O Switch 630 A. for bye Pass Main Supply & DG – 02 Nos.
Supply, fabrication, printing & erection in repair multicoloured outdoor Digital glow sign board layout plan board of size 3mx2m with all required electrical accessories for layout plan/Schematic diagram board of external electrification and layout plan board of Main Receiving station, ICU substation, GE Centre Substation, MT four pole substation, OT Substation, Laundry Plant, X-ray substation, Chiller plant Substation, PCC Substation complete with lighting and writing/drawing details complete all as specified and as directed with the following specification:- (a) Acrylic backlit glow sign board (b) 20 mm Stainless Steel square tubing frame including 20mm SS breeding all around SS sheet 16 gauge box for housing tubes etc with backlite front side (c) Necessary LED Lighting arrangement with fittings. (Make- Samsung/Philips/Wipro)
Servicing & repairing of existing 630 Amp 3 phase VCB of Make ALSTOM complete all as specified and directed. Note: Replacement of spare parts shall be measured and paid for separately under Item Nos 63 to 66 of this Schedule.
S&F Epoxy spout insulator assembly with C.C parts up to 800 amps B/B inside complete all as specified and directed.
S&F Current transformer 400+5+5 Amp complete all as specified and directed.
S&F Power pack with battery back up of 24Volt/10 Amp complete all as specified and directed.
S&F vacuum Interrupter type WL 3379 Grade complete all as specified and directed.
Repairing of Battery Charger 24 V, 10 Amp for DG Set complete with suitable size of transformer, Rectifier, Fuse, on Off indicator, Electronic card etc complete all as specified and directed.
Supply and topping Distilled Water for DG Set battery complete all as specified and directed.
S&F in repair HT terminal protector 3 core 11 KV up to 95 to 300 Sqmm Size Right Angled Cold Applied Boots complete all as specified and directed. Make- 3M/M-Seal/Raychem
S&F in repair Roly Tray PVC Channel 100mmx100mmx1mtr including laying of existing XLPE cable complete all as specified and directed.
S&F in repair PVC Flexible Pipe 50mm internal dia including laying of existing XLPE cable complete all as specified and directed.
S&F in repair Nylon cable tie, UL approved 66, 94V-2, with good tensile strength and insulation, not easy to get aging, Low Smoke and Halogen Free, size 380mmx7.60mm, tensile strength 55 kg, pack of 100 Pcs complete all as specified and directed.
S&F in repair Scotch 23 Self bonding Electrical Tape High and low voltage insulation, self fusing rubber tape 1. Polyethylene (high and low density) 2. Cross-linked Polyethylene (XLP) 3. Polyvinyl Chloride (PVC) 4. Butyl Rubber 5. Ethylene Propylene Rubber (PVC) 6. Oil-based rubber, Primary electrical insulation for splicing cable from 600 volts through 69,000 volts on all solid dielectric cables, thickness -30 mils (0.76 mm), Tensile Strength* 8 lbs/in (1,4 KN/m),Ultimate Elongation* 1000%, Operating Temperature194°F (90°C), size (38mmx9.15mmx0.75mm) complete all as specified and directed.
S&F in repair HT Tape 25mmx5 mtrs, self adhesive type complete all as specified and directed. Make Pidilite/3M/Raychem
S&F in repair LT Tape 25mmx50 mtrs, self adhesive type complete all as specified and directed. Make Pidilite/3M/Raychem
Cleaning of fuel tank made of MS sheet of 750/250 KVA DG Set of 1000 ltr capacity approx by draining out fuel in a separate container, taking out all silt/ dirt deposition inside the tank, cleaning it completely by manual labour and necessary T&P and refitting and connecting with fuel pipes with DG sets all as per site requirement complete all as specified and directed.
M&L for cleaning the body, surface of panel by rubbing with emery Paper to remove oil stains, dust etc and applying two coat of synthetic enamel paint by spray paint incl writing Ser No and area as per existing pattern complete all as specified and directed.
M&L taking out rusted Top/Bottom part of outdoor LT Panel and replaced with new 3.15mm thick GI sheet of size 0.5mx0.5m including tightening/welding of loose LT Panel door with hinges including necessary painting to match with the existing pannel complete all as specified and directed.
M&L for removal of bushes by cutting, removing vegetation, garbage, waste materials etc from site, making approach way to valve pits, pipelines, FP Boxes and cleaning the surroundings of installations complete all as specified and directed.
Saini Enterprises
Ridhi engineers and builders
BLUE HILL ELECTRICAL AND ELECTRONICS
M/s Birja Nand
Bidder Name
M P TYAGI ENGINEERS AND CONTRACTORS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .