Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.0 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹47.1 L+₹5.5 L (13.1%)Rejected-Finance 72 USMAN ENCAVE SECTOR O ALIGANJ LUCKNOW 226004 UP | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226004 | L2 | Rejected-Finance L2 | |
| 3 | Rejected-Technical | - | Rejected-Technical Due to renewal of enlistment for period 2025 to 2032 not uploaded |
| Sl No | Description | Qty | Unit | Unnati Engineers L2 | GYAN ENTERPRISES L1 |
|---|---|---|---|---|---|
| 1.00 | Excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in soft / loose soil for laying / taking up/ taking down of cables and getting out and levelling of bottom suface to required level all as specified and directed by Engineer-in-Charge. | 250 | Cum | 90 ₹22,500 Lowest | 190 ₹47,500 |
| 2.00 | Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick using excavated soil complete all as specified and as directed. | 146 | Cum | 45 ₹6,570 Lowest | 80 ₹11,680 |
| 3.00 | Removing excavated soil n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and as directed. | 97 | Cum | 45 ₹4,365 Lowest | 80 ₹7,760 |
| 4.00 | Material and labour for dry river sand, washed and screened dry for cushioning to under ground cable in trenches below and around under ground cable including spreading, levelling & punning complete as specified and directed .
Note :- Punned thickness (18 cm) shall only be considered for payment. | 73 | Cum | 450 ₹32,850 Lowest | 459 ₹33,507 |
| 5.00 | M&L laying well burnt old size bricks, sub class "B" bricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection complete all as specified & directed by Engr-in-Charge. | 8,100 | Each | 4.5 ₹36,450 Lowest | 6.5 ₹52,650 |
| 6.00 | M&L for demolition /cutting of road/ path/hardstading/ concrete in floor, etc for laying of cable complete all as directed at site by Engr-in-charge | 0.5 | Cum | 400 ₹200 Lowest | 6,000 ₹3,000 |
| 7.00 | Material and labour for PCC 1:2:4 type B-2 using 40 mm graded stone aggregates for filling of cutting of roads/path/hardstanding etc complete all as specified and as directed by Engineer-in-Charge. | 0.5 | Cum | 4,200 ₹2,100 | 4,000 ₹2,000 Lowest |
| 8.00 | Deployment of tools & manpower for Boring /drilling (Horizontly) manually / mechanically under existing road max 10 M in width) suitable for passing pipe of any descreption of dia 40 to 100 mm complete all as specified and directed by Engineer in Charge | 25 | RM | 200 ₹5,000 Lowest | 600 ₹15,000 |
| 9.00 | M&L for 80 mm bore mild steel galvanised water tubing, light grade with all fittings and fixed to walls or laid on floors / fixed to poles / or passing under road crossing, for protection of UG cable including taking down old cable complete all as specified and directed by Engr-in-Charge. | 5 | RM | 450 ₹2,250 Lowest | 1,000 ₹5,000 |
| 10.00 | M&L for 50 mm bore mild steel galvanised water tubing, light grade with all fittings and fixed to walls or laid on floors / fixed to poles / or passing under road crossing, for protection of UG cable including taking down old cable complete all as specified and directed by Engr-in-Charge. | 10 | RM | 280 ₹2,800 Lowest | 650 ₹6,500 |
Tender Value
₹37.9 L
EMD Value
₹75,720
Closing Date
19 Dec 2025, 6:00 pmClosed
GE E/M Lucknow
Garrison Engineer E/M, 36 LBS Marg, Lucknow Cantt, Lucknow (U.P.) PIN 226002
SPECIAL REPAIR TO LT PANEL/BUS BAR PANEL AND CONNECTED ITEMS AT MRA VIHAR USMAN ROAD MUPSA CANTEEN 44 SUPPLY DEPOT ATAL ROAD ZRO NIRBHAY VIHAR 71 MTN BDE RSV AND YOGENDER VIHAR AREA UNDER GE E/M LUCKNOW
2025_MES_741812_1
GE/EM/LKO/EXT(ELECT)/T-49 OF 2025-2026
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Lucknow
As per NIT
8 documents required · 8 mandatory
₹500
GE E/M Lucknow
₹75,720
Yes
21 Feb 2026
28 Nov 2025
22 Dec 2025
28 Nov 2025
19 Dec 2025
12 Dec 2025
Excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in soft / loose soil for laying / taking up/ taking down of cables and getting out and levelling of bottom suface to required level all as specified and directed by Engineer-in-Charge.
Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick using excavated soil complete all as specified and as directed.
Removing excavated soil n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and as directed.
M&L laying well burnt old size bricks, sub class "B" bricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection complete all as specified & directed by Engr-in-Charge.
M&L for demolition /cutting of road/ path/hardstading/ concrete in floor, etc for laying of cable complete all as directed at site by Engr-in-charge
Material and labour for PCC 1:2:4 type B-2 using 40 mm graded stone aggregates for filling of cutting of roads/path/hardstanding etc complete all as specified and as directed by Engineer-in-Charge.
Material & Laying, jointing and testing in replacement of LT under ground electric power cable crossed linked polyethylene ( XLPE) insulated, galvanised steel strip or wire armoured, ISI-7098 Marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of size 10 sqmm cross sectional area, 2 core, complete all as specified laid in trenches / laid under floor or fixed naked with walls / on poles/ in ducts / in GI pipes etc. with and including MS Clamps, nuts, bolts, washers complete all as specified and directed. Note :- Excavation, earth work, sand cushioning, protection bricks/ tiles/ block and pipe shall be measured and paid separately under appropriate items.
All as per item No 12 above but LT under ground cable of size 16 Sqmm 2 core
All as per item No 12 above but LT under ground cable of size 16 Sqmm 4 core
All as per item No 12 above but LT under ground cable of size 25 Sqmm 4 core
All as per item No 12 above but LT under ground cable of size 35 Sqmm 3.5 core
Disconnecting the existing cable from Panel / Pole, preparing the end for jointing including all earth work, Supply and fixing Cable end termination heat shrinkable joint including sleeves suitable for LT XLPE cable of size 3.5 core 150 to 185 Sqmm
(a) Incoming :- (i) MCCB 4 pole, 400 Amps, 50 Hz, 415 Volts, 36 KA, Ics=100% Icu with thermal magnetic release - 01 Nos (ii) on load change over 315 Amp,415 volt grade 01 No. (iii) Digital VAF+PF meter with RS 485 CL1 -01No (iv) CTs ratio 400/5 A ,class 1, ISI marked -01 sets of three (v) Indicating lamp- 01 set of three (vi) Four Pole , Aluminium bus bar 800 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators.
(b) Outgoing (i) MCCB 4 pole, 160 Amps, 50 Hz,415 Volts, 27KA, Ics=100% Icu thermal magnetic release - 02 Nos (ii) MCCB 4 pole, 125Amps, 50 Hz,415 Volts, 27 KA,Ics=100% Icu thermal magnetic release - 02 Nos (iii) MCCB 4 pole, 63 Amps, 50 Hz,415 Volts, 27 KA, Ics=100% Icu thermal magnetic release - 02 Nos Note for MCCB : All incoming & outgoing MCCB shall have double make, double break with Arc Chute per pole.
(c) Platform of Panel. Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45 cm above the nearest road level.
Note :- (i) All out going feeder shall be connected by cable through suitable size gland plate / glands. (ii) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint. (iii) The MCCB should have Ics=100% Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer
(a) Incoming :- (i) MCCB 4 pole, 400 Amps, 50 Hz,415 Volts, 36 KA, with thermal magnetic release - 01 Nos (ii) Digital VAF+PF meter with RS 485 CL1 -01 No (iii) CTs ratio 400 / 5 A, class 1, ISI marked -01 sets of three (iv) Indicating lamp- 01 set of three (v) Four Pole , Aluminium bus bar 800 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators.
(b) Outgoing (i) MCCB 4 pole, 200 Amps, 50 Hz, 415 Volts, 36 KA thermal magnetic release - 02 Nos (ii) MCCB 4 pole, 160 Amps, 50 Hz, 415 Volts, 27 KA thermal magnetic release - 02 Nos Note for MCCB : All incoming & outgoing MCCB shall have double make, double break with Arc Chute per pole.
(a) Incoming :- (i) MCCB 4 pole , 250 Amps,50 Hz,415 Volts, 36 KA, with thermal magnetic release - 01 Nos (ii) Digital VAF+PF meter with RS 485 CL1 -01No (iii) CTs ratio 200/5 A ,class 1, ISI marked -01 sets of three (iv) Indicating lamp- 01 set of three (v) Four Pole , Aluminium bus bar 500 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators.
(b) Outgoing (i) MCCB 4 pole , 63 Amps,50 Hz,415 Volts, 27KA thermal magnetic release - 8 Nos Note for MCCB : All incoming & outgoing MCCB shall have double make, double break with Arc Chute per pole.
(a) Incoming :- (i) MCCB 4 pole, 400 Amps, 50 Hz,415 Volts, 36 KA, with thermal magnetic release - 01 Nos (ii) Digital VAF+PF meter with RS 485 CL1 -01No (iii) CTs ratio 400 / 5 A ,class 1, ISI marked -01 sets of three (iv) Indicating lamp- 01 set of three (v) Four Pole, Aluminium bus bar 800 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators.
(b) Outgoing (i) MCCB 4 pole, 250 Amps, 50 Hz,415 Volts, 36 KA thermal magnetic release - 03 Nos Note for MCCB : All incoming & outgoing MCCB shall have double make, double break with Arc Chute per pole.
(a) Incoming :- (i) MCCB 4 pole , 250 Amps,50 Hz,415 Volts, 36 KA, with thermal magnetic release - 01 Nos (ii) Digital VAF+PF meter with RS 485 CL1 -01No (iii) CTs ratio 200/5 A ,class 1, ISI marked -01 sets of three (iv) Indicating lamp- 01 set of three (v) Four Pole , Aluminium bus bar 500 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators
(b) Outgoing (i) MCCB 4 pole , 100 Amps,50 Hz,415 Volts, 27KA thermal magnetic release - 05 Nos Note for MCCB : All incoming & outgoing MCCB shall have double make, double break with Arc Chute per pole.
(a) Incoming :- (i) MCCB 4 pole , 320 Amps,50 Hz,415 Volts, 36 KA, with thermal magnetic release - 01 Nos (ii) Digital VAF+PF meter with RS 485 CL1 -01No (iii) CTs ratio 320/5 A ,class 1, ISI marked -01 sets of three (iv) Indicating lamp- 01 set of three (v) Four Pole , Aluminium bus bar 800 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators.
(b) Outgoing (i) MCCB 4 pole , 100 Amps,50 Hz,415 Volts, 25 KA thermal magnetic release - 03 Nos (ii) MCCB 4 pole, 200 Amps, 50 Hz, 415 volts, 36 KA, thermal magnetic release-01 No Note for MCCB : All incoming & outgoing
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.33 MB
Tender49.pdf
Tender Documents • 1.11 MB
BOQ_830668.xls
BOQ • 0.40 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .