Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.2 LAccepted-AOC RAJADHAP WARD NO 13 P O P S SONARI DIST CHARAIDEO PIN 785690 | CHARAIDEO | ASSAM | 785690 | L1 | Accepted-AOC The work is awarded as per accepted rate. | |
| 2 | L2₹29.4 L+₹14,689.04 (0.50%)Rejected-Finance ASSAM AS | NAGAON | ASSAM | 782136 | L2 | Rejected-Finance Due to rate quoted more than the other bidder |
Tender Value
₹29.4 L
EMD Value
₹58,758
Closing Date
26 Jun 2024, 1:00 pmClosed
EXECUTIVE ENGINEER, Sonari Mahmora Division(I)
O/o The Executive Engineer, Sonari-Mahmora Division (I), Sonari
RENOVATION OF CANAL SYSTEM , MECHANICAL WORKS (BARGE) AND L.T ELECTRICAL WORK OF LIS FROM RIVER DESANG IN KHALOIGHUGURA AND BOKOTA MAUZA
2024_ID_37551_1
SMD(I)/T-6/3077 Dated 10/06/2024
Open Tender
Civil Works – Lift Irrigation Schemes
Item Rate
120 days
Khaloighugura
As per Standard Bid Document
5 documents required · 5 mandatory
₹2,000
Yes
₹58,758
Yes
Sonari-Mahmora Division(I), Sonari
6 Jul 2024
12 Jun 2024
27 Jun 2024
12 Jun 2024
26 Jun 2024
13 Jun 2024
17 Jun 2024
Amount
Cutting jungles and trees upto 50 cm girth including uprooting roots and stumps and removing them from site of work etc, complete as directed.(ii) Medium jungles.
Labour charge for dismantling of old CC works of canal structures and carriage the spoils and depositing the same in a safe distance as directed. Carriage up to lead of 30m and lift up to 1.50 M
Labour cost for dismantling of old CC canal lining and carriage of the materials and depositing the same in a safe distance as directed complete. : Carriage up to lead of 30 M and lift upto 1.50 M
Soiling in foundation at all levels including filling intersides, ramming etc complete as directed and of specified thickness with 9cm brick on flat including sand packing.
C.C works in porportion 1:3:6 in foundation/ abutment/piers/wing walls etc with hard broken stone aggregate of size 13 mm to 38 mm including curing including dewatering with necessary timber shuttering, scaffolding etc. where necessary, complete as directed. (shuttering, scaffolding cost will be paid separately.
1st class brick work in cement motar in abutment and wing wall, parapet wall etc including racking out joints and curing etc completed as directed. (I) In proportion 1:4
12 mm thick cement plastering including clearing surface and curing complete as directed (ii) In prop 1:4
Neat cement finishing 3 mm thick with cement slurry prepared by mixing 27.50 Kg of fresh cement in appropriate quantity of clean water to cover 10 (ten) SqM of work area and to give a smooth and hard finishing including rounding corners, brooming, curing etc, complete as directed.
Dry docking of the barge for fabrication
Bottom, side & deck portion of the Barge : Supply, repairing and fabrication of M.S. Plate, M.S. Angle, etc. of bottom plate, water cut portion & deck portion of the barge of size, 7.6 m x 4.58 m x 1.37 m along with supply & fabrication of M.S. Channel for installation of pump sets, starter and M.S. Angle for pipe support, etc, complete as directed by the Department as per drawing. The job also includes painting of the barge with 2 (two) coats of anticorrosive metal primer followed by 2 (two) coats of anticorrosive black bituminous paints, Each successive coat of the paint is to be applied after normal drying of the previous coat, complete as directed by the Department.
Super structure of the Barge : Supply, fabrication & erection of 8 nos of roof support of height 1.9 m providing post of M.S. angle with necessary clamping and welding at the top of barge along with roof truss and purline made of M.S. blank pipe fitted with necessary welding and bolting, complete as directed by the Department.
Roofing items of barge : Providing TATA/DYNAROOOF make C.G.I. sheet / Roofing of size 3050mm(L) x 910mm (B) x 0.50mm (T). The job includes supply of C.G.I. sheet, G.I. Ridging & fitting, fixing of entire roof with necessary J-Hooks, Nuts & Bolts with washer, complete as directed.
Rain protection shed & railing of the Barge : Supply, fitting, fixing of B.P. Sheet along with post of M.S. Angle, G.I. Pipe for railing with necessary welding & bolting, completed as directed. The job also includes painting of pipes, etc, by two coats of metalic primer to be followed by two coats paints of reputed brand, complete as directed.
Floating of the Barge at the intake point from the place of fabrication including supply and fitting of 19mm dia steel wire rope as directed.
Self Priming Centrifugal pump set (Size : Suction 150 mm and delivery 150 mm dia) 60 LPS minimum discharge at 10.00 mtr head (approx), working efficiency at head range 2.00 to 15.00 mtr (Make : Reputed brand) and to be coupled with H.D. squirrel cage induction motor having E/B class insulation conforming to IS - 325/78 (Make : Reputed brand) to be connected to power source 400/440 V, 50 Hz, 3Ph complete with 415 V, 50 Hz, 3 ph FASD starter in sheet enclosure, coupling, HD base frame , fitted in accurate alignment.
Installation of 20 H.P Centrifugal Pump set on (Horizontal Split casing type, size: 150 mm(suction) x 125 mm dia. (delivery) of 60 LPS minimum discharge at 13.00 Mt head coupled with 3 ph, 415 V, 50 Hz, 1450 RPM squirrel cage induction motor of complete Pumpset. The job includes necessary transportation of pump set to the site and its installation on Barge/ Pontoon in proper position with accurate alignment by means of foundation nuts and bolts, etc. including testing & commissioning at site at full load condition complete with all works.
Starter Stand: Supply & Installation of MS Starter Stand made of MS Angle of size 50mmx50mmx5mm including of providence C.C Block Foundation for installation of starter stand along with the required cement concrete works etc. The work includes painting of the starter stand with 1(one) coat of red oxide metal primer to be followed by 2(Two) coats of anticorrosive smoke grey paint to be applied after air drying of each previous coat.
Supply and compressing of graphite greased gland packing of reputed quality as required quantity around the rotating shaft of the pump set against the gland pressure plate to form a water tight seal and adjusting with the help of gland nut in order to accommodate continuous operation.
Laying and connection of cables such as Feeder cable, priming motor cable, lighting cable etc. i) 35 sq mm x 3 ½core
C.I. Foot valve : Heavy Duty CI Foot Valve, Flange type, the holes of the flange should be drilled as per BSS No. 10, Part -1, Table- D. The materials of construcation and all componenets of the Foot Valve should strictly conform to IS : 10805 - 1986 and having marked with manufacture's name and trade mark. Size : 150 mm dia. Make : Kirloskar/ Upadyaya/ Zolato/ Venus & Equivalent.
MSDF Pipes : Fabricated heavy duty Pipe confirming to IS 1239 (Part-I) 2004, with G.I. Flange at both end (G.I. Flange having 8 nos. holeas per B.S.S.-10 Part-I, table-D, of Size : a) 150 mm Ф x 0.30 mtr Long
MSDF Pipes : Fabricated heavy duty Pipe confirming to IS 1239 (Part-I) 2004, with G.I. Flange at both end (G.I. Flange having 8 nos. holeas per B.S.S.-10 Part-I, table-D, of Size : b) 150 mm Ф x 3.00 mtr Long
MSDF Pipes : Fabricated heavy duty Pipe confirming to IS 1239 (Part-I) 2004, with G.I. Flange at both end (G.I. Flange having 8 nos. holeas per B.S.S.-10 Part-I, table-D, of Size : c) 150 mm Ф x 2.00 mtr Long
MSDF Pipes : Fabricated heavy duty Pipe confirming to IS 1239 (Part-I) 2004, with G.I. Flange at both end (G.I. Flange having 8 nos. holeas per B.S.S.-10 Part-I, table-D, of Size : d) 150 mm Ф x 0.60 mtr Long
GI Bend : Fabricated heavy duty G.I. Bend confirming to IS– 1239 (Part-I) 2004, with G.I. Flange at both end (G.I. Flange having 8 nos. hole as per B.S.S.-10 Part-I, table-D, of size : a) 150 mm Ф x 90°.
GI Bend : Fabricated heavy duty G.I. Bend confirming to IS– 1239 (Part-I) 2004, with G.I. Flange at both end (G.I. Flange having 8 nos. hole as per B.S.S.-10 Part-I, table-D, of size : b) 150 mm Ф x 45°.
FLEXIBLE RUBBER HOSE PIPE : Flexible rubber hose pipe as per construction schedule with required nos of wire reinforcement inside at different layers, without / with MS built in type flange coupling on both ends having drilled as per BSS No. 10, Part – I, Table – D. The hose pipes should be capable of withstanding a pressure equal to 1.5 times the designed working pressure without failure as per IS : 443 - 1975 and also withstand vacuum drawn upto 625 mm of mercury (approx.).The schedule of construction of the hose pipe should conform to IS : 3549 – 1983. B.With MS built in type flange (i) 150 mm nominal dia X 4.50 Mtr in length
Fitting, fixing and laying of G.I. Pipes with Accessories in Suction side including in delivery side : Laying, fitting, fixing and connection of suction pipe line for each pump set with 150mm dia. G.I. pipes of different length, fabricated G.I. pipes with different length, fabricated bends, tapper including foot valve for suction side. Reflex valve, sluice valve for delivery side of each pump set with 150 mm dia. G.I. pipes with different length, bends, fabricated G.I. pipes with different length as per drawing. The joints should be with the best quality pipe joining sets of required size comprises of 60mm thick black moulded rubber gasket, necessary nuts, bolts and washer. Every joint should be leak proof and should be completed in all respect from foot valve to the pump flange for suction side and fr4om delivery flange is the water flow through at proper F.S.L for the delivery side. The pipes lines with accessories must be proper painting.
Providing, fitting, fixing and erection of pipe supports for each pipeline at on interval of 3.00 Mtr. (approx) made of M.S. Channel (ISMC 75) 1.50 Mtr. height with angle bracing erected on CC block of size 0.45mX0.30mX0.60m below ground.
Supply, Fitting-fixing of Heavy duty CIDF sluice valve inside screw, non raising, vertical spindle type with hand wheel operation, need for water purpose. The rotation of closing should be counter clock wise. The holes of the flange should be drilled as per BSS No. 10, part-I, Table-D. All materials construction and components should strictly conform to IS:14846 – 2000 and having marked with manufacturers name and trade mark in the delivery pipe layout as directed/ as per drawing along with HD GI flange, pipe jointing materials and painting in complete as directed (iii) 150 mm dia
Supply, Fitting-fixing of Heavy duty CIDF Reflex valve, swing check type, with bypass arrangement, horizontal operating.The holes of the flange to be as per BSS No. 10, Part-I, TableD and the material, construction and all components should strictly conform to IS : 5312 (Part-I) – 2004 and having marked with manufacturers name and trade mark in the delivery pipe layout as directed/ as per drawing along with HD GI flange, pipe jointing set and painting in complete as directed (iii) 150 mm dia
Hacksaw blade (12MM X 300MM)
M.S. Nuts & Bolts (Assorted Size) B.Q.
M.S. Washer (Assorted Size) B.Q.
G.I. Nipple (both end threaded) of length 0.30 m. b) 150 mm dia.
M. Seal (100 grams Pkt.)
Emery cloth
Waste cotton (Best Quality)
W B grease (Best Quality)
Steel wire brush (Std. Size) (Best quality)
Pipe jointing set complete with 6 mm thick moulded Rubber Gasket, M.S. Nuts & bolts with washer suitable for:c) 150 mm dia flanged pipe
Nylon rope (16 mm to 25 mm dia) (Best quality).
Manila rope (16 mm to 25 mm dia) (Best quality)
Black/ Red Electrical resistant rubber sheet, one side with chequred and other side is cloth finish tested upto 15 KVA as per ISS of ISI approve made size : 1.81M (L) X 0.90M (B) X 10mm (T)
Disconnecting the transformer from the 11 kV line of APDCL lifting it from the pad/pole by labourers/ crane and loading it on carriage vehicle and carrying the same to workshop upto a distance of 35 KM and unloading it by manual labour/crane as required and as directed. b) 100 kVA Al
Opening, Preliminary checking and lifting of Core Coil assembly. b) 100 kVA Al
Supply & fitting of new HV coils conforming to original gauge, shape & size and deducting the salvage value of scraps. b) 100 kVA Al
Supply & fitting of new LV coils conforming to original gauge,shape & size and deducting the salvage value of scraps. b) 100 kVA Al
Making of core coil assembly, varnishing & heating of core coil assembly in vacuum heat chamber till requisite insulation level is attained. b) 100 kVA Al
Cleaning the transformer tank, removing dust, dirt, rust etc completely then painting outside & vernishing the inside of tank with approved quality & colour of paints as directed. c) 100 kVA Al
Supply & fitting of new porcelain HV bushing
Supply & fitting of new porcelain LV bushing
Supply & fitting of new HV stud
Supply & fitting of new LV stud
Tanking of the core coil assembly, making all necessary connections with HV/LV studs/OLTC etc as required
Supply & filling fresh transformer oil conforming to ISS 353/1993 including necessary filtering
Testing of the transformer at workshop after repairing under the supervision of depatmental staff
Carriage of the repaired transformer from workshop to site, reinstallation on pole structure/ pad at substation and complete connection on HV and LV side by skilled labourer under supervision of Electrical Supervisor having trade licence and, testing of the whole installation, then reconnection of power as directed by the department.
Supply and Laying of PVC/ XLPE Insulated ArmouredLT Power Cable 1.1 kV Grade with Al Conductor of size 120 mm2× 3.5 Core in double line,ConformingIS 7098(Part I) 1988, direct in ground includingdigging of trench of 0.3 Mtr wide × 0.75 Metre deep including Sand Cushioning (7.5 cm + 7.5 cm) and refilling alongwith fitting, fixing of Brass Compression Gland and Aluminium Cable Lug etc. as directed. 120 Sq mm × 3½ core
Supplying fitting fixing of LT Power Capacitor 415 Volt AC 3 φ (Single Unit) of following KVAR Rating and making connection with Busbar in the existing Panel. The Capacitor is to be placed in existing Platform. (6 kVAR
Supplying, fabrication and erection of Iron Angle Stand for erection of LT Power Capacitor made of MS Angle of size 30 mmX 30mm X5 mm with 4 Nos of legs 400mm high and cross pieces having Bakelite Sheet horizontal platform as directed. Size of the Frame : (300 mm x 300 mm) x 400 mm
Supplying including fitting, fixing and connection of TPN Main Switch (SDFU- Switch Disconnector Fuse Unit) with HRC fuses, 415V AC, Open Execution, Panel Mounting type of following rating in already fabricated Control Panel Board housing , along with lugs, connecting cable and all other necessary materials as directed, (100 Amps)
Supplying including fitting, fixing and connection of three pole 415V, AC 50 Hz Motor Protection Circuit Breaker (MPCB) with adjustable thermal and magnetic setting with rotary handle of following current/HP ratings in already fabricated LT Control Panel Board housing along with lugs, connection cable and all other necessary materials for connection as directed. (32 A / 20 H.P.)
Supply and Laying of 3 (Three) Core PVC/ XLPE Insulated Armoured LT Power Cable 1.1 kV Grade with Al Conductor in existing open trench/ in air including fixing with necessary clamps etc. in wall/pole/ other support including End Termination with Brass Compression Gland and Cable Lug as required and as directed ( As per SOR ELE, 2023-24) (9.1 B. ii) Size of Cable : 50 mm2 × 3 Core ( Single Line)
(SUPPLY & ERECTION OF EARTH PIPE) Supply & Erection of C.I. Earth Pipe 100 mm dia × 2.5 Metre long perpendicular to the ground including digging of Earth Pit, putting Salt and Charcoal in alternate layers surrounding the pipe along with fitting of hinged CI top Cover Plate and necessary C.C. work as directed
(COPPER EARTH WIRE), Supply & Erection of 6 SWG Copper Earth Wire and making Earth connection of different Substation Items by connecting the existing Earth Pipes with necessary Lugs as directed
Bubul Gogoi
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .