Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.3 LAccepted-AOC | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹31.0 L+₹2.2 L (7.46%)Rejected-Finance | L2 | Rejected-Finance Not Being Lowest | |
| 3 | L3₹32.9 L+₹4.1 L (14.1%)Rejected-Finance 137 3 STREET NO 4 RAJINDER NAGAR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L3 | Rejected-Finance Not Being Lowest | |
| 4 | L4₹33.0 L+₹4.2 L (14.4%)Rejected-Finance | L4 | Rejected-Finance Not Being Lowest | |
| 5 | L5₹38.7 L+₹9.9 L (34.3%)Rejected-Finance | L5 | Rejected-Finance Not Being Lowest |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
8 Oct 2022, 6:00 pmClosed
GE (Central) Delhi Cantt-10
GE (Central) Delhi Cantt-10
REPAIR/ REPLACEMENT OF OLD UNSV ELECTRICAL FITTING WITH LED LIGHT FITTING INCLUDING BLDG SECURITY LIGHT AND DISTRIBUTION BOARD ALONGWITH PETTY REPAIR AND MISC E/M WKS AT SANJAY VIHAR HQ 5 SIG GP 500 I SIG COY 6 SIKH 1 ARMY HQ SIG REGT ARMY CYBER GP C
2022_MES_551545_1
GE/C-51/2022-23
Open Tender
Civil Works
Item Rate
335 days
GE (Central) Delhi Cantt-10
As per NIT
9 documents required · 9 mandatory
₹500
Yes
GE (Central) Delhi Cantt-10
₹1 L
Yes
15 Oct 2022
13 Sept 2022
10 Oct 2022
13 Sept 2022
8 Oct 2022
26 Sept 2022
13 Sept 2022 - 26 Sept 2022
Amount
Taking down care fully copper/aluminium point wiring from wooden batten or conduits (light, fan, socket or power) complete excluding fittings such as switches, sockets, ceiling roses, pendents, regulators, light fittings any type etc to be measured seperately) and making good disturbed surfaces of walls, floors etc.
M & L for Point wiring complete with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn through and including non-metalic rigid new PVC conduit medium grade ISI Marked and all conduit accessories concealed in wall/ceiling/fixed to roof/truss/columns etc and including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuty, fabricated branded new metal flush box duly make embossed, concealed in walls with for housing switches , socket out let and fan regulators etc , all as specified and as directed for the followings:-
(a) One light/Exh fan point controlled by one No one way switch
(c) One 3 pin 5 Amps socket outlet point controlled by one No one way switch on independent board.
(d) One 3 pin 5 Amps socket outlet point controlled by one No one way switch on same board
All as per item No 2 but point wiring with 2.5 Sqmm single core copper cable and earth continuity wire with 2.5 Sqmm single core stranded copper cable for one three pin 15 socket outlet point on independent board. Note (i) PVC conduit shall be Medium grade, ISI marked.
M&L point wiring with PVC unsheathed multi stranded copper conductor cable 1.5 sqmm (nominal dia) FRLS 1100 Volts in existing PVC concealed conduit in new M S steel terminal boxes of wall thickness not less than 1.6mm including 3 mm thick laminated top sheet cover including using 1.5 sqmm FRLS 1100 Volts copper conductor cable as earth continuity connected to common earth all as specified and directed by Engr-in-Charge.
(a) One light/Exh fan point controlled by one No one way switch
(b) One bell / buzzer point controlled by one bell push
(c) One light point controlled by two Nos two way switches
(d) One 3 pin 5 Amps socket outlet point controlled by one No one way switch on independent board.
(e) One 3 pin 5 Amps socket outlet point controlled by one No one way switch on same board
M&L point wiring with PVC unsheathed multi stranded copper conductor cable 2.5 sqmm (nominal dia) FRLS 1100 Volts in existing PVC concealed conduit in new M S steel terminal boxes of wall thickness not less than 1.6 mm including 3 mm thick laminated top sheet cover including using 2.5 sqmm FRLS 1100 Volts copper conductor cable as earth continuity connected to common earth for one power point, all as specified and directed by Engr-in-Charge.
Checking electrical points for continuous electric supply system and replacement of unserviceable spares for all electrical fixtures, ceiling/exhaust fans of any size and capacity and carrying out minor repairs, fixing screws, tightening of loose wires, any type renewal of small pieces of electric wire upto 1.00 mtr length and maintenance work complete on all working days including holidays all as directed by Engr-in-charge, at Sanjay Vihar, HQ 5 SIG GP, APS Colony, 1 AHQSR, Bath Road, 105 TA, Karan VIhar, Uri Enclave, 1 WEC, RR COlony, Sabre Mess, Church Road & Gym Road and other connected area under GE (Central) Delhi Cantt-10.
Attending to Geyser complaints at site including checking and rectification of any electric fault/ water leakage and making good in all respects including minor repairs, replacement of unserviceable spares, burnt copper wire connections wherever required and repairing any type of switch, socket, plug top etc complete all as specified and directed. Notes for Item No. 6 and 7 (a) Supply only spares shall be measured and paid under relevant item of Sch 'A'/ BOQ (b) Contractors are advised to visit the sites before quoting their rates. (c) Materials for minor and maintenance repair works as directed by Engineer-in-Charge shall be supplied by the contractor within one week from the date of issue of work order. (e) Contractor shall provide and deploy adequate experienced Exp. professional to carry out day to day complaints and tradesman will remain present in Sanjay Vihar and Bath Road Complainet Cell from 0830Hrs to 1800 Hrs from Monday to Sunday (02 Electrcian and 02 Helper at Sanjay Vihar and Bath Road) . In case of any breakdown/ emergency, contractor shall make arrangement to attend and rectify the complaints in odd hours on sunday/ holiday also. The rates quoted in sch 'A' respective items shall be deemed to be included and nothing extra shall be admissible on this account.Note:whatever be the nature of electrcal complaint the wholesole rectification responsibilty lies with the contractor. (f) Contractor shall be penalised @ Rs. 100/- per complaint per day, if he fails to attend the complaint within 8 hours.
Taking down sub main wiring off sizes etc complete all as specified and directed.
Supply, laying and drawing in existing concealed PVC rigid surfaces as per existing surfaces or as directed on walls 02 runs of IC x 6.00 sqmm (Main Cable and neutral) and one run of IC x 6.0 sqmm (as earth wire) of stranded copper conductor PVC insulated unsheathed cables of 1100 volts grade conforming to IS : 694 of 1990 complete including connection all as specified and directed.
Supply only sheet metal enclosure single pole and neutral enclosure with a two pin earth plug and socket complete with one single pole MCB 20 Amp complete all as specified and directed.
Supply only sheet metal enclosure single pole and neutral enclosure with a two pin earth plug and socket complete with one single pole MCB 10 Amp complete all as specified and directed.
Supply only LED batten luminaire surface mounted, 4 feet system wattage of 22 Watts, > 2400 systems lumen outputwith lifetime of 50000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.95, THD< 10%, colour temperature - 6500K, surge protection 2.5KV in CM, IP-20 protected, meets LED IS specifications, Class - 1, Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 DegreeC and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete all as specified and directed.
Supply only LED batten luminaire surface mounted 2 feet system wattage of 10 watts and not less than 1000 lm with life time of 50000 burning hours with 70% of its initial lumen maintained. CRI > 80, power factor > 0.95, THD < 10%, color temperature > 6500 K , surge protection 2.5 KV in CM IP- 20 protected meets LED IS specifications, voltage range - 150 to 270 volts AC, temperature range 0 to 50 Degree C, system efficiancy at luminarie level ≥100 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire fixed complete all as specified and directed.
Supply LED 9/10 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP65 Protection, System level efficacy of the Luminary is > 90 lm/W with a life class of 50,000 burning hours at L70 criteria, Power Factor >0.95, driver with Voltage range 150-270V, Temperature range 0 to 50 Deg, Driver efficiency >85%, THD<10%, CRI>80, Color Temperature-6000K, Surge protection of 2.5 KV, including connecting up with necessary PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed.
Supply only surface ceiling mounted, round LED down light fitting 12 watts with die cast aluminium housing and system wattage of 12W, system efficacy at luminary level ≥ 80 Lumens/watt, 50000 burning hours, 6500K color temperature with CRI >80, Power Factor > 0.90, Driver should meet IEC compliant for safety with multi stage high Isolate CC-CV operated driver with voltage variation range - 150 to 270 Volts AC, and surge protection of 2.5 KV, and including connecting up with PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed.
Supply only 14W LED Bulbs, high energy efficiency LED luminaries to be fitted on existing holders 240 V,50 Hz
Supply only 9 W LED Bulbs, high energy efficiency LED luminaries to be fitted on existing holders 240 V,50 Hz,
Supply only replacement of capacitor 3.15 Mfd, 240 V complete all as specified and directed.
Supply only replacement of capacitor 2.5 Mfd, 240 V complete all as specified and directed.
Supply only batten/angle holder including with connections complete all as specified and directed.
Supply only switch piano flush button type single pole one way 6 Amps all as specified.
Supply only switch piano 6 amp SP two way, ISI marked
Supply only socket piano outlet 6 Amp flush button type all as specified
Supply only bell push single pole 6 Amps all as specified
Supply only switch piano flush button type single pole 16 Amps.
Supply only socket piano outlet, 2 in 1, 3 pin 6 and 16 Amp single pole .
Supply only Ceiling fan regulator electronic step switch type 120 Watt 230/250 Volts single phase complete. :
Supply only switch Modular type 6 Amps one way 230V AC complete all as specified and directed by Engineer in charge.
Supply only Modular socket outlet 5 pin 6 Amp socket 2 moduler complete all as specified and directed by Engineer in charge.
Supply only switch Modular type 16 Amps one way 230V AC complete all as specified and directed by Engineer in charge.
Supply only Modular socket outlet 5 pin 6/16 Amp universal socket 2 module complete all as specified and directed by Engineer in charge.
Supply only Modular five stepped type electronic fan regulator 2 module 230V AC complete all as specified and directed by Engineer in charge.
Supply only swich & socket combined 5 pin 6 Amp sp
Supply only swich & socket combined 5 pin 16 Amp sp
Supply only ceiling rose surface PVC 65x50 mm type with three terminals.
Supply only relacement plug top 16 Amps 3 pin 230- volts
Supply only Electric bell Ding-Dong AC 230 Volt etc complete all as specified and directed.
Supply only MCCB 160 Amp 4 pole 16 KA at 415 V with fixed thermal magnetic release complete all as specified directed.
Supply only MCCB 125 Amp 4 pole 16 KA at 415 V with fixed thermal magnetic release complete all as specified directed.
Supply only double pole MCB 40 amp, 240 v, 50 Hz AC Made from moulded self-extinguishing thermostat plastic and suitable for 10 KA breaking capacity, complete all as specified and directed..
Supply only Single pole MCB 6 to 32 amp, 240 v, 50 Hz AC Made from moulded self-extinguishing thermostat plastic and suitable for 10 KA breaking capacity, complete all as specified and directed.
Supply only r MCB SPN 40 Amps 240 volts 10 KA 50 HZ 'C' curve complete.
Supply only MCB DP 20 Amps 240 volts 10 KA 50 HZ 'C' curve complete.
Supply onlyr MCB DP 32 Amps 240 volts 10 KA 50 HZ 'C' curve complete.
Supply only MCB DP 63 Amps 240 volts 10 KA 50 HZ 'C' curve complete.
Supply only FRLS insulated single core unsheathed multistranded copper conductor 1100 volt 1.5 sqmm with approved colour code completed all as specified.
Supply only FRLS insulated single core unsheathed multistranded copper conductor 1100 volt 2.5 sqmm with approved coloured code completed all as specified.
Supply only FRLS insulated single core unsheathed multistranded copper conductor 1100 volt 4 sqmm with approved coloured code completed all as specified.
Supply only heating element of 2 KW triangular type with nut bolt washer complete all as directed.
Supply only heating element of 2 KW circular type with nut bolt washer complete all as directed.
Supply only heating element of 1.5 KW triangular type with nut bolt washer complete all as directed.
Supply only non return valve 15mm dia (ISI Marked) for Geysers of 50/35/25 Ltr capacity including GI Socket,Nipple, elbow ,bend etc and connecting up complete all as directed.
Supply only for safety pressure valve of size 15 mm dia, ISI marked for geysers complete all as directed by Engineer-in-charge.
S&F of thermostat for 25/35/50 ltrs capacity of geysers complete all as directed.
Supply only hylum sheets 3 mm thick (ISI marked) of the following sizes :-
(a) Sheet 4" x 4" single cutting suitable for one piano switch
(b) Sheet 4" x 4" two cuttings suitable for two piano switches
(c) Sheet 4" x 7" three cuttings suitable for three piano switches
(d) Sheet 4" x 7" one cutting for 6 Amp socket and two cuttings for piano switches
(e) Sheet 8" x 10" incl cuttings for switches and sockets 6/16Amps as directed.
(f) Sheet 10" x 12" incl cuttings for switches and sockets 6/16Amps as directed.
Taking down carefully geysers 25/35/50 ltrs capacity opening for inspection reassembling and re-fixing in position after carrying out repairs rates included for replacement of pressed rubber gasket nuts, bolts etc complete all as directed. Note- Spare Parts such as tank, apparatus plate, outer body shall be measured and paid separately under relevant item of supply only.
Supply only base plate assembly (confirming to ISI ) complete for 25/35 Ltrs capacity copper tank geyser including inlet, outlet and thermostat pipe with drain plug and screws for fixing the element inclusive of clamps for holding the elements with nut, bolts & air release valve suitable for any type/make of geysers installed at site as directed.
M & L chromium plated copper connection pipe 60 Cm long with two brass adopters and connecting up complete all as directed.
Supply only inner still tank for geysers of capacity 25/35 ltr as per existing of approved make complete all as directed
S&F in replacement of decorative type (Comet) wall mounted luminaire with unbreakable poly carbonate materials suitable for 1x14 watt LED bulb B22 base.
S &F Wall fan 400 mm 3 blade in replacement sweep metal type including provision of 3 core PVC insulated sheathed 1100 volts grade flexible cable with stranded copper conductor, length as per requirement at site.
supply and fix recessed mounting LED FLAT panel 2"x2" made of crca sheet steel duly power coated with high efficient LED and glaire free full opal diffuser , IP 20 Suitable for 36 watt,230 volts ,50 Hz AC Supply, Neutral White,with electronic driver and incluiding all fixing accessories complete all as specified and directed.
M&L for submain wiring with two single core PVC insulated FRLS 1100 Volts unseathed stranded copper conductor cable 4 Sqmm in and including PVC conduit for submain wiring and connection complete including rigid PVC conduit FRLS grade,unsheathed copper conuctor cable of 4 Sqmm size stranded conductor as earthwire.
M&L in replacement copper cable flexible 3 core PVC insulated of size 23/.0076 ll as specified and directed by Engr-in-Charge.
M&L in replacement copper cable flexible 3 core PVC insulated of size 40/.0076 ll as specified and directed by Engr-in-Charge.
S & F hole fastner madeup of MS 6" long with complete nut bolt all as specified.Make:as per sample
S & F hole fastner madeup of MS 4" long with complete nut bolt all as specified.Make:as per sample
Supply & fix in repair factory made epoxy powder coated Distribution Board TPN-4 ways with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amp copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removeable gland plates with knockouts and suitable for one TPN- MCCB 125/160 Amp as incomer and 40 to 63 Amp SP MCBs outgoing complete all as specified and conforming to IS : 8623.
Supply and fix MCB DB SPN 12 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and DP/SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete all as directed by Engineer -in- Charge.
Supply and fix MCB DB SPN 8 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and DP/SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete all as directed by Engineer -in- Charge.
Supply only exhaust fan motor capacity 1/4 HP 230 volts suitable for 250 mm size exhaust fan complete all as directed.
S &F exhaust fan 300 mm in replacement sweep metal type including provision of 3 core PVC insulated sheathed 1100 volts grade flexible cable with stranded copper conductor from ceiling rose to fan, length as per requirement at site.
Supply and fixing Ventilating Fan 250 mm sweep, 1250 RPM, non metallic resin body, single phase 240 volts AC 50 Hz and connecting up complete including louvers and provision of copper cable 3 core of size 0.5 sqmmincluding writing MES NO. 2 CM height with synthetic enamelled black paint complete all as specified and as directed.
Cutting the existing wall/removing existing steel bar to make a hole for fixing of exhaust fan through packing of wooden ply to support the ventilating/ air circulating fan including necessary nut and bolts of suitable size incl make good of disturbed surface complete all as directed by Engr-in charge.
M&L for earthing complete with galvanized steel earth plate 600 x 600 x 6 mm thick, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized iron wire 4 mm dia as earthing lead by means of bolts, nuts, check-nuts, and washers of galvanized iron or steel besides welding at all joints including excavation and earth work, GI pipe light grade 15mm bore for protection of G.I. wire from earth electrode to the Main switch/Distr Board, supplying and laying charcoal dust, common salt, PCC 1:2:4 type B-1 using 20mm graded stone aggregate chamber and MS angle iron frame 40 x 40 x 3 mm and RCC cover 40 mm thick RCC (1:2:4) type B-1 using 20 mm graded stone aggregate reinforced with 6 mm dia round bars @ 75 mm C/C both ways with MS handle 12 mm dia, round, PGI funnel and wire mesh, 20 mm dia GI pipe light grade for watering all as shown in Plate No. 3 of SSR Part I of 2009 and connected to earth test point including testing complete all as specified & directed.
Supply and fix in repair Sub main wiring complete with two runs of 10 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 10 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 25 mm dia non metallic rigid PVC conduit and conduit accessories(Surface) in walls all as specified and as directed. Note:- PVC rigid conduit ISI marked FRLS Grade.
S&F GI Pipe bracket bent to shape drilled welded made out of light grade GI pipe 32mm dia 1.5 mtr long and fixing on the wall where as directed by the Engr-in-Charge for fixing of building security light fitting including clamps, nuts, bolts and washers complete all as specified by the Engr-in-Charge .
Supply and Fix in repair 45 W High efficient LED Street light fitting with pressure die cast LM6 Aluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover. System level efficacy of the Luminarie is 100lm/W with a life class of 50,000 burning hours at L70. The color temperature is around 6500 K with a color rendering index of 70. The luminaire is IP:66 protected with IK05 impact resistance. It has an electronic driver complaint to IEC safety standards with a power factor>.0.9, voltage variation range 120-270V, THD<20%, High and low protection along with a surge protection of 4 KV including provision of 40mm dia GI light grade pipe1.5 meter length bend to shape and necessary clamps etc for fixing the light fittings on pole fixed complete as specified and directed.
Schedule of Credit
NAVDURGA BUILDERS
M/S ANIL KUMAR
Microsys Controls India
MODERN CONCEPT CONSTRUCTIONS
MRITUNJYA ASSOCIATES
LAMBA ENTERPRISES
POONAM ENTERPRISES
m/s VK construction company
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .