Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹7.8 LAccepted-AOC | 1 | Accepted-AOC BEING LOWEST | |
| 2 | 2₹8.9 L+₹45,300 (5.35%)Rejected-Finance | 2 | Rejected-Finance BEING NOT LOWEST | |
| 3 | 3₹9.0 L+₹48,970 (5.78%)Rejected-Finance 65 MATA KA MANDIR RAM NAGAR COLONY SHAHJAHANPUR 242001 UP | SHAHJAHANPUR | SHAHJAHANPUR | UP | 242001 | 3 | Rejected-Finance BEING NOT LOWEST | |
| 4 | 4₹9.6 L+₹1.1 L (13.0%)Rejected-Finance 1 215 BHOOSA MANDI FATEHGARH FATEHGARH FARRUKHABAD UTTAR PRADESH 209601 | FARRUKHABAD | UTTAR PRADESH | 209601 | 4 | Rejected-Finance BEING NOT LOWEST |
Tender Value
₹9.9 L
EMD Value
₹20,000
Closing Date
5 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE(I) Fatehgarh
AGE(I) Fatehgarh
REPAIR/ MAINT OF EXTERNAL ELECTRICAL SUPPLY SYSTEM AT FATEHGARH CANTT.
2024_MES_636055_1
AGE(I)/FAT/ET-45 OF 2023-2024
Open Tender
Miscellaneous Works
Item Rate
180 days
AGE(I) Fatehgarh
As per tender docu
8 documents required · 8 mandatory
₹500
₹20,000
Yes
1 Mar 2024
8 Jan 2024
12 Feb 2024
8 Jan 2024
5 Feb 2024
23 Jan 2024
8 Jan 2024 - 22 Jan 2024
Amount
Excavation in trenches n. exc 1.5 m wide and n.exc 1.5 m in depth and getting out soft/loose soil complete all as specified and as directed for laying of under ground cable, foundation of pole and stay etc. complete all as specified and as directed
Returning, filling in, including spreading, levelling, watering and well remmining in layers not exc 25 cm. complete all as specified and as directed
Removing excavated material n.exc 50 m and depositing where directed at a level n. exc 1.5 m above the starting point all as directed.
M&L for sand cushioning to U/G cable in layers of 23 cm thick( 8 Cm before laying the cable and 15 Cm thick after laying the cable) in trenches complete all as specified and directed .Note :- Only Puned down volume shall be measured.
Supply and lay burnt best quality locally available old size sub class 'B' bricks laid in trenches perpendicular to U/G cable for cable protection complete all as specified and as directed.
Laying only serviceable bricks obtained from the items specified here-in-before (i.e during taking out of under ground cable),laid flat dry, in trenches with width of the bricks laid to the axis of cable for protection of cable complete all as specified and as directed
Taking out unserviceable LT U/G cable from trenches of size 6 Sqmm to 120 Sqmm 2/3.5/4 core complete all as specified and as directed.
Supply and lay in trenches or passing through pipe XLPE insulated armoured, heavy duty electric cable with aluminium conductor 1100 volts grade, cross-sectional area 70 Sqmm 3.5 core complete all as specified and as directed.
…..ditto as above but for size 50 Sqmm 3.5 core…. Ditto….
…..ditto as above but for size 25 Sqmm 4 core…. Ditto….
…..ditto as above but for size 16 Sqmm 4 core…. Ditto….
…..ditto as above but for size 6 Sqmm 2 core…. Ditto….
Relaying of existing serviceable underground cable of size 6 Sqmm 2/4 Core to 120 Sqmm 3.5 core obtained from the items specified (i.e during taking out of under ground cable) complete all as specified and as directed.
M&L MS clamp made out of 50x6 mm flat iron bending cold or hot,drilling holes for bolts , in any shape or size as indicated or directed and inclusive of one primer coat,one under coat and one finishing aluminium coat of paint complete all as specified and as directed.
Boring holes horizontally under road without damaging the surface of road ( minimum 1.0 Metre below the road surface with the help of GI tubing not exc 80 mm bore(dia) for passing UG cable, complete all as specified and as directed. NOTE : - GI Pipe laid will be measured and paid separately under respective item
S&F in replacement of 40 mm bore GI tubing light grade with all fittings laid across road, in trenches or across PCC drain, along electric pole or floor/wall for cable protection with suitable size of MS clamps and nut and botls/washers complete all as specified .
S&F in replacement of 25 mm bore GI tubing light grade with all fittings laid across road, in trenches or across PCC drain, along electric pole or floor/wall for cable protection with suitable size of MS clamps and nut and botls/washers complete all as specified .
M&L for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick, burried directly into the ground (earth pit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to GI earth strip 25 x 4 mm by means of bolts, nuts, check nuts, and washers of galvanised iron or steel all as shown iln electrical plate No. 3 connected to earthing test point all as specified or indicated including excavation and connected earth work, PCC chamber and cover, watering pipe, funnel wire mesh but without earth lead protection pipe and test on completion after dismantling unserviceable erthing (above GL only) complete all as directed.
M & L for aluminium strip 25 x 3 .15 mm with base insulators and screws etc fixed on wall/ floor for extension of earthing lead complete all specified
Dismantling existing unserviceable feeder pillar box including disconnection from different sites complete all specified and directed.
Fabrication, supply, installation, commissioning and testingin replacement of outdoor type feeder pillar box floor mounted made out from 3.15 mm thick MS sheet ( CPRI type tested) with canopy type roof and front operated, two part hinged doors with locking arrangement comprising of copper bus bar suitable for 3 phase, 4 wire, 415 volts,50 Hz, AC supply mounted on suitable bus bar insulators, 200 Amps rating suitably drilled and tapped for bolts with openable two part front and rear shutter with heat strinkable PVC sleeving having RYB-B colour code drilling holes for connection of incoming and outgoing cable, complete powder coated painting, testing and installation complete in embedded in PCC 1:3:6 type C-2 ( using 40 mm graded aggregate ) n. exc. 0.45 cum and provision of following accessories complete all as specified and as directed ( Note :-MCCB will be measured and paid separately.)
M & L for DK Thermoplastic cable junction boxes IP 65 with metric knockouts for cable entry, weather proof for outdoor installation and including glands and with 4 terminals for terminating one incoming and outgoing UG cable of size 10/16 sqmm 3.5/4 core and including 40 mm GI pipe for holding LED light and fixed to the PCC/Steel Poles by means of suitable size of clamps with nut and bolts and all specified and directed.
S & F in replacement of MCCB 400 Amps, 4 pole, 415 volts, 50 Hz 36 KA breaking capacity with adjustable thermal magnetic release with spreader link on both sides with existing size and make as suitable to fit in the existing LT FPB all as specified and directed
S & F in replacement of MCCB 250 Amps, 4 pole, 415 volts, 50 Hz 36 KA breaking capacity with adjustable thermal magnetic release with spreader link on both sides with existing size and make as suitable to fit in the existing LT FPB all as specified and directed
S & F in replacement of MCCB 160 Amps, 4 pole, 415 volts, 50 Hz 25 KA breaking capacity with adjustable thermal magnetic release with spreader link on both sides with existing size and make as suitable to fit in the existing LT FPB all as specified and directed
S & F in replacement of MCCB 200 Amps, 4 pole, 415 volts, 50 Hz 36 KA breaking capacity with adjustable thermal magnetic release with spreader link on both sides with existing size and make as suitable to fit in the existing LT FPB all as specified and directed
M&L straight through joints( epoxy) for LT underground cable including joint kits suitable for aluminium conductor cable 3.5 core 6 sqmm to 120 sqmm all as specified and directed
M&L outdoor LT END Termination Heat Shrink Kits for LT underground cable suitable for aluminium conductor cable of size 6 sqmm to 120 Sqmm (3.5/4C) all as specified and directed
S&F in replacement of Busbar chamber in sheet metal enclosure 100 Amp, 4 way TPN 415 Volt of aluminium busbar drilled holes including cadmium coated nuts, bolts, washer etc fixed on wall complete all as specified and directed.
S&F in replacement of Busbar chamber in sheet metal enclosure 200 Amp, 4 way TPN 415 Volt of aluminium busbar drilled holes including cadmium coated nuts, bolts, washer etc fixed on wall complete all as specified and directed.
Disconnection and dismantling of existing serviceable under ground cable of size 6 Sqmm to 120 Sqmm 2/4 core from LT Panel/FPB and taking out cable/cable loop from underground by excavtion of soft/loose soil and insertion of heat shrinkable PVC colour sleeves on cable cores and crimping of suitable size aluminium cable lugs as required and refixing the same in its original position complete all as specified and as directed.
M/S J.B.AND SONS
M/S CHAUHAN ELECTRIC WORKS
M/S SRI JAGDAMBE TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .