Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.9 LAccepted-AOC GARH ROAD MEERUT UTTAR PRADESH 250002 INDIA | MEERUT | UTTAR PRADESH | 250002 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹13.3 L+₹1.1 L (8.98%)Rejected-AOC LAMA VILLA DYMMIEW SHILLONG 793002 | EAST KHASI HILLS | MEGHALAYA | 793002 | L2 | Rejected-AOC Not Lowest |
Tender Value
Refer Docs
EMD Value
₹33,500
Closing Date
9 Dec 2020, 6:00 pmClosed
GE Guwahati
GE GUWAHATI PO SATGAON DISTT KAMRUP - 781027
REPAIR/MAINT OF TRANSFORMER, LT PANELS, LT CABLES, STREET LIGHT AND OTHER ALLIED WORKS AT CDA RESIDENTIAL COMPLEX UNDER GE GUWAHATI
2020_MES_395067_1
GE/GUW/T/39/2020-21/8988
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Guwahati
As per tender documents
7 documents required · 7 mandatory
₹500
GE Guwahati
₹33,500
Yes
28 Mar 2021
13 Nov 2020
11 Dec 2020
13 Nov 2020
9 Dec 2020
27 Nov 2020
13 Nov 2020 - 26 Nov 2020
Amount
Excavating in trenches not exc. 1.5 m wide and not exc. 1.5 m in depth for foundation, laying of pipes, etc. and not exceeding 10 Sqm on plan and notexceeding 1.5 m in depth and getting out as in soft/loose soil, complete all as specified and directed.
Excavation in trenches not exceeding 1.50 m wide and exceeding 1.50 m deep and not exceeding 3.0 m in depth for foundations or for shafts, wells, cesspits, manholes, pier holes etc. not exceeding 10 Sqm on plan and exceeding 1.50 m deep and not exceeding 3.0 m in depth and getting out in soft/loose soil, complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in soft loose soil, complete all as specified and directed.
Removing excavated surplus soils to a distance not exceeding 50 metres and depositing where directed, at a level not exceeding 1.5 metre above the starting point, complete as specified.
Supply and laying well burnt brick, Sub class ‘B’, old size as in cable protection, laid across in trenches, complete all as specified and directed.
M & L for sand cushioning with clean, dry sand in trenches for protection of UG cables, complete all as specified and directed.
S&F in repairs Tubes , light grade galvanised with all fittings 40 mm bore for laying of cable under trenches , road fixed to wall/pole with suitable size of MS flat clamps for cable protection, complete all as specified and directed.
S&F in repairs Tubes , light grade galvanised with all fittings 80 mm bore for laying of cable under trenches , road fixed to wall/pole with suitable size of MS flat clamps for cable protection, complete all as specified and directed.
M&L Hard surface cutting as in road, pavement, etc. for laying of cables, pipes etc of any size up to a approximate width 45 cm and depth 60 cm and making good to surfaces with PCC 1:3:6 type C-2 complete after laying of cable, pipe etc as required, complete all as specified and directed.
M&L for making hole by suitable means for insertion of GI pipe 40mm bore to 80mm for passing cable across the road without cutting the road complete as required and as directed by the Engr-in-Charge.
Taking out old underground cables, any size or capacity from trenches, ducts, floor, pipes including cable protection and removing materials from site of work complete all as directed by Engineer-in-Charge. (Note : Excavation and earth work shall be measured and paid separately)
Supply & laying in trenches / fixed to pole, walls. etc LT, XLPE insulated, armoured, heavy duty electric power cable with aluminum conductor, 1100 Volts grade, cross sectional area 10 Sqmm, 2.0 core conforming to IS-7098 (Part-I)-1988 and testing, complete all as specified and directed.
Supply & laying in trenches / fixed to pole, walls. etc LT, XLPE insulated, armoured, heavy duty electric power cable with aluminum conductor, 1100 Volts grade, cross sectional area 16 Sqmm, 4.0 core conforming to IS-7098 (Part-I)-1988 and testing, complete all as specified and directed.
Supply & laying in trenches / fixed to pole, walls. etc LT, XLPE insulated, armoured, heavy duty electric power cable with aluminum conductor, 1100 Volts grade, cross sectional area 25 Sqmm, 4.0 core conforming to IS-7098 (Part-I)-1988 and testing, complete all as specified and directed.
Supply & laying in trenches / fixed to pole, walls. etc LT, XLPE insulated, armoured, heavy duty electric power cable with aluminum conductor, 1100 Volts grade, cross sectional area 95 Sqmm, 3.5 core conforming to IS-7098 (Part-I)-1988 and testing, complete all as specified and directed.
Supply & laying in trenches / fixed to pole, walls. etc LT, XLPE insulated, armoured, heavy duty electric power cable with aluminum conductor, 1100 Volts grade, cross sectional area 240 Sqmm, 3.5 core conforming to IS-7098 (Part-I)-1988 and testing, complete all as specified and directed.
Supply , Installation and Testing XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts grade, cross sectional area 95 Sq mm, 3 core, complete all as specified and directed.
Only Laying and Testing of XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts grade, cross sectional area 95 Sq mm, 3 core. ( Cable to be supplied by MES ), complete all as specified and directed.
Supply and laying un-reinforced precast concrete cable cover, class HV, type I flat size of 300 x 180 mm x 40 mm, complete all as specified and directed.
M & L for Cable jointing Kit for 11 KV ( Earthed) grade cable for outdoor termination cold shrink type Joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium cable of size 95 Sqmm 3.0 core including taking down of Old Jointing Kit all as specified and directed by Engr-in-Charge.
M & L for Switch air break gang (11 KV) operated triple pole, mechanically operated, mounted on insulator and steel frame with operating mechanism worked from ground level for current rating upto 200 Amps including dismantling of old unsv one from 4 pole structure, complete all as specified and directed.
Material and labour for expulsion fuse assembly single pole vertically mounted on MS channel 11000 volts grade upto 100 amp capacity including making connections with HT cables/ GOD with provision of jumper, including dismantling of old unsv one, complete all as specified and directed.
S&F Single disc assembly with disc insulator, porcelain, vitreous 145 mm high and 225 mm dia ball and socket type white, brown or green for tension with tension clamps for conductors working pressure 11000 Volts grade, including taking down of insulator, complete all as specified and directed.
Supply only cable jointing kit for 1.1 KV grade cable for outdoor termination heat shrinkable joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 to 240 Sqmm including taking down of Old Jointing Kit, complete all as specified and directed. Make: M Seal/ Birla-3 M/Denson
M & L for preparation of old painted surfaces of LT steel tubular pole 9.00 / 11.0 m long, cross arms, bracings, supports, clamps, back plate with nut bolts washers and providing one coat of aluminium paint including numbering and making strips in circular shape of diameter 150 mm black colour letter of height 50 mm complete all as directed by Engr in Charge not exceeding 150 mm upto 1.5 mtr above ground level with alternate layer of yellow and black paint, complete all as specified and directed.
S&F in repairs Bracket suitable for fixing of street light fitting made out from 40mm bore GI pipe, medium grade 1.5 metre in length, made to shape as required, fixed to pole/ wall with MS flat iron clamp of size 25x4mm duly welded, bent to shape and making holes etc complete including necessary nuts, bolts & washer etc as required, complete all as specified and directed.
S&F in repairs, thermoplastic cable junction box IP 66 with metric knockouts for cable entry and 4 way terminal of size 205 x 255 x 112 mm , fixed in position with aluminium clamps of size 25x3mm and screws, complete all as specified and directed. (Make : Hensel, Cat No KF 2525 G )
S&F in replacement, PVC insulated, sheathed aluminium conductor cables 4.00 Sqmm twin core for connection from kisok box to street light fitting through pole etc. as required complete with suitable clamps as specified and directed.
S&F in repairs MCCB 125 Amps ,4 pole , Adjustable thermal & fixed magnetic setting, breaking capacity 25 KA incl electric connections with in existing panel board all as directed. Make: Havells ( IHLASF0125 ) or equv in Indoasian/ L & T
S&F in repairs MCCB 63 Amps ,4 pole , Adjustable thermal & fixed magnetic setting, breaking capacity 25 KA incl electric connections with in existing panel board, complete all as specified and directed. Make: Havells ( IHLASF0063 ) or equv in Indoasian/ L & T
S&F in repairs Pressure die-cast aluminium housing 60 W LED street light luminiare with epoxy powder coated with weather proof gasket for LEDs and control gear compartments suitable for pole mounting including electric connectionincluding taking down of old fittings, complete all as specified and directed. Make : Crompton PINNACLE PLUS (Product Cat No LST-60-CDL) or equivalent in Philips/Bajaj
S&F in repairs 50 W LED flood light luminaire, IP-65 ,die-cast aluminium flood light with high power LEDs as light source, suitable for highlighting architectural features or Area Lighting including electric connection with twin core PVC insulated aluminium conductor, multistranded cable of specified size testing including taking down of old fittings, complete all as specified and directed. (Make : Crompton PROFILE+ NEO (Product Cat No LFL-60-CDL/60-M) or equivalent in Philips/Bajaj
S&F in repair 35 W LED post top gate light luminaire with spun aluminum landscape luminaries with high power LEDs as light source. including electric connection with twin core PVC insulated aluminium conductor, multistranded cable of specified size and necessary clamps to fit the luminaire on pipe, complete all as specified and directed. (Make : Havells RUBY (CLEAR) - IP65 (Product code No RUBYPT35WLED757PSYMTOPC) or equivalent in Philips/SURYA
Disconnecting HT/LT side cable connections and removing 200 KVA transformer from mounting platform, draining out transformer oil for repair/maintenance of transformer complete all as specified and directed.
Maintenance of transformer such as cleaning of core and winding by means of washing down with clean dry oil to remove dust/sludge on core and coil, cleaning of oil tank to remove sludge deposits, replacement of old rusted gasket set, burnt out spindle, broken/unserviceable HT and LT ceramic bushing, broken arc horn surge arrester,painting of outside surface of transformer complete for transformer of following capacity all as required and directed by Engineer-in-Charge :- (Note : (a) Cost of oil for cleaning shall be deemed included in the quoted rate. (b) New Spares required at site against the replacement of old unserviceable one shall be measured and paid separately as ‘Supply only’ under relevant items here-in-after.) item No. 28 to 30
Supply only breather assembly of approved make filled with silica gel suitable for transformer of 200 KVA complete all as specified and directed.
Supply only gasket set for top lid cover of LT and HT terminal bushing suitable for transformer of 200 KVA complete all as specified and directed.
Supply only brass spindle for terminal on HT side threaded complete with nut washers etc of suitable dia for transformer of 150 - 250 KVA capacity, complete all as specified and directed.
Supply only brass spindle for terminal on LT side threaded complete with nut washers etc of suitable dia for transformer of 150 - 250 KVA capacity, complete all as specified and directed.
Supply only ceramic bushing on HT side suitable for transformer of 150 - 250 KVA capacity, complete all as specified and directed.
Supply only transformer oil of approved quality as per IS having dielectric strength of 40-60 KV in 2.5mm gap for filling in transformer or for topping up as required and directed. (Make : Gulf/Savita/Trans Power Oil as approved)
Dehydration and filtration of transformer oil by means of centrifugal filtration plant to achieve desired dielectric strength of 35 to 40 KV at 2.5mm gap in existing position of transformer of any capacity and topping up transformer oil at various Sub-Stations all as required and directed by the Engr-in-Charge. (Note : Deficient quantity of transformer oil required for topping up will be paid under item here in before).
Disconnecting of both HT and LT connection from cable end box and taking down the disconnected transformer (Out Door/Indoor type) of 150 to 250 KVA capacity from platform with the help of recovery/Hydra, chain pulley and other T&P required at site, and transportation of unserviceable transformer to authorized civil workshop and bringing back at same location after repair in a suitable vehicle including loading, unloading, complete all as directed .
Installation of transformer of same capacity or higher capacity (upto 250 KVA) in place of unsv transformer (which found major repair and taking to wksp for repair), on hire basis for maximum period of 10 days when ordered. Note:- Repairing of transformer have to be completed with in 10 days duration, no extra cost will be paid toward hiring charges beyond 10 days. Moreover contractor will not be allowed to shift the hired transformer until it is replaced by the repaired transformer. Any thing goes wrong in the hired transformer, no extra cost will be paid towards repairing of hired transformer. Contractor should check the available infrastructure and to be sure regarding safety of transformer before installation. The rate quoted is deemed to be included transportation cost, connecting incoming & outgoing cables, earthing leads lifting/lowering arrangement, labour etc., complete all as specified and directed.
Supply and Fixing in repair 20 W LED post top lantern(garden light) with spun aluminium landscape luminaries with high power LEDs as light source including electric connection with twin core PVC insulated aluminium conductor, multistranded cable of specified size and necessary clamps to fit the luminaire on pipe complete all as specified and directed. (Make : Crompton Heritage (Product code No LPTH-20-CDL) or equivalent in Philips/SURYA
S & F in repair Multi function meter digital type of LCD display, size 95 Sqmm square type including making incoming/outgoing connections in Existing Panel , Showing Max demand complete all as specified and directed. Make: (L & T MFM 4410 LED meter Cl 1 Cat No. WL442010OOOO)
Supply and fixing in repair Electronic driver suitable for 48-60 Watt street light fittings complete all as specified and directed
Supply and Fixing in repair Synthetic insulation mat of dimension 2m X 1m X 25mm for suitable insulation near LT Panels and DG Set including removing of old synthetic mat complete all as specified and directed.
Dismantling old unserv Earthing , M&L Earthing complete with galvanised steel earth plate electrode 600mmx600mm x 6mm thick, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m deep below normal ground level, connected with GI earth strip of size 25 X 4 mm as earth lead up to test point by means of nuts, bolts, check nuts protected by and including GI pipe 40mm bore (light grade) and connected to main test point as directed and including concrete pit in PCC (1:3:6) type C-1, precast RCC (1:2:4) type B-1 cover slab 30cm x 30cm x 10 cm, reinforced with 8mm dia TMT bars @ 100 mm C/C both ways with one handle for lifting, made out of 8mm dia TMT bar embedded in pre cast cover slab, funnel, wire mesh, 15mm bore GI pipe (medium grade) for watering, charcoal and salt in alternate layers, including necessary excavation and earth work in any type of soil complete all as shown on Electrical Plate No 3 of SSR Part-I, complete all as specified including taking down old one and as directed.
Dismantling old unserv Earthing , M&L Earthing complete with galvanised steel earth plate electrode 600mmx600mm x 6mm thick, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m deep below normal ground level, connected with GI earth strip of size 32 X 6 mm as earth lead up to test point by means of nuts, bolts, check nuts protected by and including GI pipe 40mm bore (light grade) and connected to main test point as directed and including concrete pit in PCC (1:3:6) type C-1, precast RCC (1:2:4) type B-1 cover slab 30cm x 30cm x 10 cm, reinforced with 8mm dia TMT bars @ 100 mm C/C both ways with one handle for lifting, made out of 8mm dia TMT bar embedded in pre cast cover slab, funnel, wire mesh, 15mm bore GI pipe (medium grade) for watering, charcoal and salt in alternate layers, including necessary excavation and earth work in any type of soil complete all as shown on Electrical Plate No 3 of SSR Part-I, complete all as specified including taking down old one and as directed.
Material and Labour in repair for Steel tubular swaged poles complete with cast iron base plate finial taper plug, bolts, nuts and screws as specified type 410 SP-55(11 mtrs long ) and painting with 2 coats of aluminium paint over a coat of primer complete all as specified and directed.
Material and Labour in repair for Aluminium conductor steel reinforced (ACSR) in LT/HT OH lines or Street lights of sqirrel/weasel as per site requirement complete all as specified and directed.
Material and Labour in repair for MS Cross arms, bracings, supports etc. incl nuts, bolts, washers, welding, bending, drilling inclusive of one primer coat, 1 under coat and 1 finishing coat of paint complete all as specified and directed.
Material and Labour in repair for Pin type insulator porcelain vitreous white or brown including 1 galvanized mild steel spindle, 2 galvanized iron washers, 1 galvanized iron nut, 150 mm height, 150 mm dia, 11000 volts grade complete all as specified and directed.
M & L for Plain Cement concrete M-10(Nominal Mix) using 40 mm graded stone aggregate in foundation filling and mass concrete including dismantling of old foundation complete all as specified and as directed.
M & L for Plain Cement Concrete M-15(Nominal Mix) using 20 mm graded stone aggregate as in street light pole coping including dismantling of old coping complete all as specified and as directed.
S & F in repair AC Single phase static Energy meter( Kwh type ) of accuracy class 1.0 rating 5-30 Amp, including polycarbonate body with LCD display Box covering, pilfer proof meter box complete all as specified and directed and transported back to MES store for safe keeping . Make: (L & T Cat No. WM101BC5DDHBOX)
S & F in repair AC Three phase static Energy meter( Kwh type ) of accuracy class 1.0 rating 10-60 Amp, including polycarbonate body with LCD display Box covering, pilfer proof meter box complete all as specified and directed and transported back to MES store for safe keeping . Make: (L & T Cat No. WM301BC6D20)
S&F in repair Sub main wiring with 2 runs of single core, 6 Sqmm PVC insulated, unsheathed, 1100 volts grade multi-stranded, copper conductor cables (FRLS quality) drawn through PVC caing caping fixed on roof, walls, ceiling etc including 4 Sqmm PVC insulated, unsheathed, single core, multistranded,, copper conductor as earth continuity wire complete as specified and directed. (Note : (i) PVC Casing Caping and its accessories measured and paid separately (ii) Two runs of cable and one run of earth wire shall be measured as one run length )
Disconnecting electrically of Automatic power factor correcting panel (APFC panel ), of 25 / 50 kVAr capacity by taking out the enclosure including all components ,checking of power factor correction capacitors, APFC relay, capacitor duty contactors complete and refixing the same after duly repaied and replacement of unserviceable components/parts and testing of power factor after reparing complete all as specified and directed by Engr-in charge Note:- New Spare/Parts shall be measured and paid separately under relevent items as “Supply only”)
Supply only power factor correction capacitors heavy duty cylindrical (Gas filled) 2.5 KVAr , 440 Volts, , complete all as specified and directed. Make: (L&T /Schenider/Havells)
Supply only power factor correction capacitors heavy duty cylindrical (Gas filled) 5 KVAr , 440 Volts, complete all as specified and directed. Make: (L&T / Schenider/Havells)
Supply only Capacitor duty contactor 50 KVAr , 415V , 3 Ph , 50 Hz , Type MO C 50 built in auxiliary contacts 1 NO , 1NC, complete all as specified and directed. Make: L&T(Cat No CS96324) or equivalent Schenider/Havells
M/S DIL SINGH BISWA AND CO
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .