Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.7 LAccepted-AOC 606 80 FEET ROAD 7TH BLOCK 2ND PHASE BANASHANKARI 3RD STAGE BANGALORE 560 085 | BENGALURU URBAN | KARNATAKA | 560085 | L1 | Accepted-AOC AWARD OF CONTRACT | |
| 2 | L2₹47.9 L+₹3.9 L (8.98%)Rejected-Finance | L2 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 3 | Rejected-Technical 121004 | - | Rejected-Technical REJECTED DUE TO CONTRACTOR NOT ENLISTED IN PARTICULAR CATEGORY c (vi) | |
| 4 | Rejected-Technical DOOR NO 6 1 JOTHI NAGAR 6TH STREET VARATHARAJAPURAM UPPLIPALAYAM PO COIMBATORE 641015 | COIMBATORE | COIMBATORE | TAMIL NADU | 641015 | - | Rejected-Technical REJECTED DUE TO CONTRACTOR NOT ENLISTED IN PARTICULAR CATEGORY c (vi) | |
| 5 | Rejected-Technical 16 176 A BHARATHI PURAM NAGAI NAGAR DINDUGUL 3 | DINDUGUL | DINDIGUL | TAMIL NADU | - | Rejected-Technical REJECTED DUE TO CONTRACTOR NOT ENLISTED IN PARTICULAR CATEGORY c (vi) |
Tender Value
Refer Docs
EMD Value
₹99,000
Closing Date
12 Sept 2024, 6:00 pmClosed
GE (AF) SULUR
Garrison Engineer AF Sulur Military Engineer Services Kangayampalayam Post Sulur Coimbatore 641 401
COMPREHENSIVE MAINT AND REPAIR/REPLACEMENT OF FIRE ALARM SYSTEM/FIRE DETECTOR SYSTEM/ UVIR DETECTOR SYSTEM/ FOURUM PROTECTION SYSTEM/ CO2 FLOODING SYSTEM AND OTHER CONNECTED ITEMS AT AF STN SULUR
2024_MES_667876_1
8694/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
GE (AF) SULUR
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Yes
GE (AF) SULUR
₹99,000
Yes
20 Nov 2024
25 Jul 2024
14 Sept 2024
25 Jul 2024
12 Sept 2024
1 Aug 2024
25 Jul 2024 - 30 Jul 2024
Amount
SCHEDULE A BOQ
M & L for periodical maintenance of automatic fire alarm and smoke detectors system comprising of following mentioned items including attending fault testing of system, monthly checking of system including preventive maintenance by replacing small spare parts and technician will attend the complaints at site whenever deffect occur in fire alarm/detection system and rectifed complete all as specified and directed:- (a) VISONIC (Existing make) Wireless Fire Alarm Control Panel : Using wireless technology that is highly secure, the Power Master-10 G2 delivers superior range, long battery life and unmatched wireless robustness. (b) VISONIC (Existing make) Wireless Smoke and Heat Detector :- It alerts occupants of the room by activating the built-in 85db alarm buzzer and flashing LED light when smoke or temperature exceeding 57°C (135°F) are detected (c) VISONIC(Existing make) Wireless Outdoor Siren: is a two-way wireless outdoor siren (IP55). It provides the perfect security solution for home owners with a Power Master system who are looking for an affordable and easy to install outdoor siren. The SR-740 PG2 excels in offering cabling-free installation and optional extended time between battery changes. (d) VISONIC(Existing make) Wireless Repeater: extends the communication range between the PowerMaster control panels and other Power G devices Locations: T5, T6, T7, T8, T31, Pionerring Depot, Signal Station, Navy Hanger, AFNET, Avionics Lab, BCR, CCR, HRDF Hut, Transmitter
M & L for periodical maintenance of automatic fire alarm and smoke detectors system comprising of following mentioned items including attending fault testing of system, monthly checking of system including preventive maintenance by replacing small spare parts and technician will attend the complaints at site whenever deffect occur in fire alarm/detection system and rectifed complete all as specified and directed:- (a) HONEYWELL (Existing make) 4 Loop Control Panel: This addressable four-loop, fire detection system supports Morley protocol. It comes with two sounder circuits (1A max), A2A power source, a general relay (Alarm and Fault), one programmable relay, a fixed auxiliary output and resettable 24V 250mA output, two keys and two inputs for programmable functions. It also includes a 6 x 40 LCD graphic display (b) HONEYWELL (Existing make) Smoke Detector: The HM Series photoelectric smoke detectors by Honeywell have a completely new detection chamber design , integrated LED for 360Deg visibility Advanced protocol and smoothing filter to suppress false alarm, EN54-17: 2005 EN54-7: 2000+A1:2002+A2:2006 LPCB approved (c) HONEYWELL (Existing make) Loop Card: The new Loop Card is designed to fully comply with EN54-23 and is available on EN54 versions of the Vigilon range of panels. The increased power allows for up to 100 EN54-23 sensor-sounder-strobes on a 2km loop, managing up to 200 devices in total
(d) HONEYWELL (Existing make) Sounder: VAD-series wall mount sounder beacon is a high quality loop powered device designed to alert building occupants of an emergency. It utilises the B501AP base for improved installation flexibility (e) HONEYWELL (Existing make) Input Output Module: The MI-DMMI and MI-DMM2I use a unique mechanical design allowing each module to be mounted either in a wall box (M200E-SMB) or on a DIN rail (using M200E-DIN). (f) HONEYWELL (Existing make) Heat Detector: Low profile, 2 inches, including base Absolute temperature device Simple and reliable addressing Uses digital communication protocol The SD505-HEAT is UL Listed and meets the requirements outlined in NFPA 72 InspectionTesting and Maintenance Locations: New ATC, DWR, JFS Test Cell
M & L for periodical maintenance of automatic fire alarm and smoke detectors system comprising of following mentioned items including attending fault testing of system, monthly checking of system including preventive maintenance by replacing small spare parts and technician will attend the complaints at site whenever deffect occur in fire alarm/detection system and rectifed complete all as specified and directed:- (a) HOTCHIKI (Existing make) 4 Zone Conventional Panel: Product Code: 0100-19340 The HCV-X series of conventional fire control panels are available with 2, 4, or 8 initiating circuits which may be extensively configured via a simple front panel operated programming method.Standard Features UL864 approved (b) HOTCHIKI (Existing make) Smoke Detector: The SOE-24V (UL 268 7th edition listed) is the newly developed multi-spectrum smoke categorization technology Photodiode Supply Voltage Operating Voltage Range 8 – 35VDC Absolute Max Voltage 42VDC Maximum Voltage Ripple 8200mVAC Maximum Input Capacitance 0.01uF Current Consumption Standby Current 59A Minimum Allowable Alarm Current 5mA Maximum Allowable Alarm Current 150mA Startup Time 25s (Max) Current 160A (Max) Reset Time 100ms (Min) Voltage 2.5V (Max) Smoke Density Range 1.82-3.16%/ft@ Open area 1.82-4.55%/ft@300FPM in Duct 1.82-3.96%/ft@1000FPM in Duct 1.82-4.19%/ft@2000FPM in Duct 1.82-4.07%/ft@3000FPM in Duct 1.82-4.20%/ft@4000FPM in Duct Detector Compatibility ID HD Compatible Bases NS4-100, NS6-100, NS4-220, NS6-220, NS4-221, NS6-221, NS4-224, NS6-224, HSC-220R, HSC-221R, HSC-224R, HSC-4R, HSC-4R12
(f) HOTCHIKI (Existing make) Repeter Panel: The HFP CP range of conventional fire control panels are high specification IP Rating IP30 Finish Epoxy powder coated Colour - lid & box BS 00 A 05 grey - fine texture Colour - controls plate & labels RAL 7047 light grey - satin Weight 6kg Supply voltage 20-30V DC Mains supply fuse 1.6 Amp 250V Power supply DC rating 24V 1 Amps Maximum battery size 7Ah 12V (2 per panel) Fault contact rating 30V DC1 Amp Fire contact rating 30V DC1 Amp Cable capacity 2.5mm2 per terminal Operating temperature -5°C to +40°C Operating Humidity <95% (non condensing) Dimensions (mm) 385 x 310 x 60 Location: Avaro Hanger 1 Avaro Hanger 2 Dornier Hanger Radiography Hanger (g) RAVEL (Existing make) Conventional Panel 2 Zone: As per IS -15908: 2011 Standard. 16 X 2 Dot Matrix LCD Display. Standby battery backup with built in charging. Fire / Fault status in unambiguous colored LED indication.Switch Mode Power SupplyTactile Keypad for easy panel operation System on indication.
(h) RAVEL (Existing make) Smoke Detector: UL listed.Dual LED’s for 360° visibility.Advanced detection and communication protocol.Easy installation and maintenance.Sleek low-profile housing design.Regular 100mm base. Operating Voltage 9 ~ 33V DC Operating Temperature:-10 °C to 37.8 °C Storage Temperature:-10 °C to 60 °CHumidity:0 – 95% RH, non-condensing Reset Voltage (j) RAVEL (Existing make) Manual Call Point: Alarm status is indicated By Red colour LED Operates on 24 VDC. Green Colored for Emergency Release. Yellow Colored for Abort. 1 No’s of CO & NC Output (Optional).Operating Voltage :24VDC (k) RAVEL (Existing make) Sounder: Slim and Sleek Wall or Ceiling mountable Mini Horn with BackBox 24VDC Operation They are used in Fire, Burglar & Emergency Alarm System. Operating Voltage:24V DC Operating Current:40mA Sound
M & L for periodical maintenance of automatic fire alarm and smoke detectors system comprising of following mentioned items including attending fault testing of system, monthly checking of system including preventive maintenance by replacing small spare parts and technician will attend the complaints at site whenever deffect accur in fire alarm/detection system and rectifed complete all as specified and directed:- (a) Siemens (Existing make) addressable Fire Alarm Control Panel : Automatic alaram grade 10 to 30 mA, Ac input power 230 V, addressable 5 loop control panel no of addrees 505 upto 8 loop extended programble input output 12 nos . (b) Siemens (Existing make) Smoke and Heat Detector :- 24 Vdc , PVC white automatic, photo electric (c) Siemens (Existing make) Outdoor Siren: (d) Siemens (Existing make) manual call pont & Repeater: (f) Addressable type Flame detectors with UV/IR detection capacity (g) Control CO2 flooding system :- release panel model RE-25AR make- Ravel, UL listed (9th Edison), including switch mode power supply, battery polarity and deep discharge suitable for CO2 flooding system installed at SRE bldg (h) Edward Make control panel at FMS, wireless detectors, hooter/strobe, MCP and indicators Locations: 18 Sqn Hanger, 43 Sqn Hanger, Tech flt Hanger and FMS Note:- Requirement of tools/lifting vehicle/ladder for maint of UV detector and smoke detector and connected wires inclusive in quoted rate.
Note for item No 2 to 9 :- (a) The contractor shall make AMC contract with the authorised service agency of any make for fire fighting equipments and the repairs/ maintenance shall be carried out through the Authorised service agency only as per instructions recommended by the original manufacturer.
(b) The rate quoted shall be deemed to include for carried out all repairs noticed during the period.
(c) The authorised service agency must attend as and when called for urgent nature of repair of the fire fighting system up to 9 month contract period as whenever required.
(d) Checking of Alarm signal should not lost when primery power failure untill the alarm signal processed.
(e) Checking of audio amplifiers and tone genrating equipment.
(f) Checking of smoke detector sensibility
(g) Checking of all speaker circuit and loops.
(h) Periodicity of servicing shall be around 01 months or as per manufacturers recommendation.
S&F in replacement of VISONIC (Existing make) Wireless Fire Alarm Control Panel : Using wireless technology that is highly secure, the PowerMaster-10 G2 delivers superior range, long battery life and unmatched wireless robustness. A perfect solution for monitoring service providers who require high performance at a low cost. Suitable for large residential and small to mid-size business installations. Two-way communication eliminates lost alarms and unnecessary re-transmissions. Efficiently overcomes interference and jamming through multi-channel frequency hopping. Advanced radio technology delivers large transmission range enabling repeater-free installations.30 wireless zones, 8 user codes, Supports partitions,12 or 24-hour battery, A single wired zone, Optional LTE and IP modules, Available in multiple languages complete all as specified and directed by Engr-in-Charge. Locations: T5, T6, T7, T8, T31, Pionerring Depot, Signal Station, Navy Hanger, AFNET, Avionics Lab, BCR, CCR, HRDF Hut, Transmitter
S&F in replacement of VISONIC (Existing make) Wireless Smoke and Heat Detector: reliably sends early warnings in case of smoke or fire with a fully supervised, photoelectric smoke and heat detector. It alerts occupants of the room by activating the built-in 85db alarm buzzer and flashing LED light when smoke or temperature exceeding 57°C (135°F) are detected. At the same time, it transmits a coded signal to the control panel to activate the system siren, alerting the end user and/or central monitoring station to send onsite assistance.Fully ceritifed by the most stringent internal standards.Includes additional alerts for low battery, smoke sensor trouble, maintenance required, device tampering, and test mode.Ultra-reliable, two way 128-bit AES encrypted communication and iron-clad protection blocks interference to deliver unparalleled cyber protection. Provides accurate early fire warning, with audio and visual alerts, when smoke or high temperature is detected Enhances safety and maintenance, with alerts for device tampering and low battery Ensures performance using built-in PowerG leading-edge wireless intrusion technology with two-way communication Offers long-lasting value with a 3-year battery life (with typical use) Large transmission range enables repeater free installations Speeds up installations with visible link quality indicator on the device Simple wall or ceiling installation, with bracket Protected by a back tamper complete all as specified and directed by Engr-in-Charge Locations: T5, T6, T7, T8, T31, Pionerring Depot, Signal Station, Navy Hanger, AFNET, Avionics Lab, BCR, CCR, HRDF Hut, Transmitter
S&F in replacement of VISONIC (Existing make) Wireless Outdoor Siren: is a two-way wireless outdoor siren (IP55). It provides the perfect security solution for home owners with a PowerMaster system who are looking for an affordable and easy to install outdoor siren. The SR-740 PG2 excels in offering cabling-free installation and optional extended time between battery changes. Fully wireless outdoor siren designed for installation in areas in which wiring is dificult or impossible. The sounder is activated for a predefined "Bell Time" according to local authority's requirements, or until the system is disarmed, whichever occurs first. Includes sound types for burglar, fire, gas (CO), and flood. Prolonged battery life (up to 8 years with typical use) Loud 110db piezo siren Sleek design and robust weatherproof housing (IP55) with high power strobe light Large print screen area for customizable logos Large transmission range enabling installations Dimensions: 295 x 186 x 63mm (11.63 x 7.31 x 2.5in) complete all as specified and directed by Engr-in-Charge Locations: T5, T6, T7, T8, T31, Pionerring Depot, Signal Station, Navy Hanger, AFNET, Avionics Lab, BCR, CCR, HRDF Hut, Transmitter
S&F in replacement of VISONIC (Existing make) Wireless Repeater: extends the communication range between the PowerMaster control panels and other PowerG devices. It receives alarm, status and control messages from the wireless devices and sends these messages to the control panel.Visible link quality indication shown directly on the device.Compact and easy to install.LED indications for power failure, activity, and installation performance diagnostics.Transmission range is by far greater than the industry standard complete all as specified and directed by Engr-in-Charge Dimensions: 161 x 161 x 50mm (6.44 x 6.445 x 1.74in) Powered with 48 hour backup battery (rechargeable). Locations: T5, T6, T7, T8, T31, Pionerring Depot, Signal Station, Navy Hanger, AFNET, Avionics Lab, BCR, CCR, HRDF Hut, Transmitter
S&F in replacement of HONEYWELL (Existing make) 4 Loop Control Panel: CONTROL PANELThis addressable four-loop, fire detection system supports Morley protocol. It comes with two sounder circuits (1A max), a 2A power source, a general relay (Alarm and Fault), one programmable relay, a fixed auxiliary output and resettable 24V 250mA output, two keys and two inputs for programmable functions. It also includes a 6 * 40 LCD graphic display, an integrated USB port for PC programming and an RS485 port for repeaters. The DXc2 can operate as a stand-alone or as part of a networked system with other DXc series panels up to 16 loops.The CD contains a loop and battery calculator, manuals and programming software that allow the display to be customised and address labels to be imported from an Excel file.Total Loop Capacity (396 Detector +396 Devices)Networking up to 16 loops 6x40 characters, blue liquid crystal display with backlight illumination Configuration by keypad and PC 160 Fire Zones Fire, Fault and Auxiliary relays Loop-Battery calculator for reliable system design 7 day timer Onboard diagnostic EN54-2, EN54- 4 LPCB approved Optional: 40, 80 or 160 zone alarm LEDs complete all as specified and directed by Engr-in-Charge Locations: New ATC, DWR, JFS Test Cell
S&F in replacement of HONEYWELL (Existing make) Smoke Detector: The HM Series photoelectric smoke detectors by Honeywell have a completely new detection chamber design, the result of many years of research and development. This delivers improved responsiveness, reduced sensitivity changes caused by settling dust and reduced false alarms resulting from ingress of insect and other debris. The plug-in unit uses sophisticated processing circuitry that incorporates smoothing filters to help eliminate transient environmental noise conditions that can be the cause of unwanted alarms.Available with or without short circuit isolation Dual integrated LED for 360Deg visibility Advanced protocol and smoothing filter to suppress false alarm Enhanced smoke chamber design to reduce false alarms by dust or contamination Worldwide proved reliability Certifications: EN54-17: 2005 EN54-7: 2000+A1:2002+A2:2006 LPCB approved complete all as specified and directed by Engr-in-Charge Locations: New ATC, DWR, JFS Test Cell
S&F in replacement of HONEYWELL (Existing make) Loop Card: The new Loop Card is designed to fully comply with EN54-23 and is available on EN54 versions of the Vigilon range of panels. The increased power allows for up to 100 EN54-23 sensor-sounder-strobes on a 2km loop, managing up to 200 devices in total.Benefits Improved efficiency with 2 times more alarm power with no loss of standby Supports up to 100 S-Quad Sensor-Sounder-VADs certified to EN54-23 Increased capacity for loop powered devices including the new EN54-23 visual alarm devices Supports longer loop lengths up to 2km (Use of the loop load design tool may result in longer loops being allowed) Loop current increased to 800mA when used with the latest S-Quad and S-Cubed devices PC based diagnostic tool to ensure optimum system integrity complete all as specified and directed by Engr-in-Charge Locations: New ATC, DWR, JFS Test Cell
S&F in replacement of HONEYWELL (Existing make) Manual Call Point: The call point is an addressable break glass manual call point which has a simple rotary decade switch at the rear of the unit for addressing. A specialist test key may be inserted into the bottom of the unit to lower the glass and release the micro-switch and thus a full functional test is achieved. The HM-MCP-GLASS-AP Call Point is designed to provide a manual alarm interface to Morley IAS’s fire alarm control panel. Installation efficiency, compliance with the latest standards are at the heart of the call point range The LED status is controlled by fire panel and shows blinking RED each time the device is polled, or continuous RED to indicate fire. Unique ‘Plug & Play’installation concept Analogue addressable communications Fully compliant with EN54, Part 11 Integral LED Backward Compatibility complete all as specified and directed by Engr-in-Charge Locations: New ATC, DWR, JFS Test Cell
S&F in replacement of HONEYWELL (Existing make) Sounder: VAD-series wall mount sounder beacon is a high quality loop powered device designed to alert building occupants of an emergency. It utilises the B501AP base for improved installation flexibility. When triggered by the fire panel its powerful sounder and intense beacon give a visible and audible warning. A choice of output levels and tones make the device suitable for a wide variety of applications Faster installation Reduced full life costs Flexible installation Reduced inventory count Excellent system performance Certifications: EN54-23 approved LPCB VdS Approved & Listed to AS 7240.3 SAI Global Listing# SMK40640-5 AS 7240.23 complete all as specified and directed by Engr-in-Charge. Locations: New ATC, DWR, JFS Test Cell
S&F in replacement of HONEYWELL (Existing make) Heat Detector: Low profile, 2 inches, including base Absolute temperature device Simple and reliable addressing Uses digital communication protocol The SD505-HEAT is UL Listed and meets the requirements outlined in NFPA 72 InspectionTesting and Maintenance, Chapter 7. CFSM listed MEA listed FM approved Operating Voltage: 17 to 41 VDC Current Consumption:Standby: .55 mA Alarm: .55 mA Detection Temperature Range: 135°F to 150°F (57°C TO 65°C) Ambient Temperature: 32ºF to 120ºF (0ºC to 49ºC)Mounting: 4" SQR, 4" OCT Single gang mud ring Rated Spacing: 70’ between sensors on smooth ceilings.Compatible Bases: SD505-6AB (Sold Separately) SD505-6SB SD505-6IB SD505-6RB P/N: 350963 Rev complete all as specified and directed by Engr-in-Charge. Locations: New ATC, DWR, JFS Test Cell
S&F in replacement of HOTCHIKI (Existing make) Smoke Detector: The SOE-24V (UL 268 7th edition listed) is the newly developed multi-spectrum smoke categorization technology that detects smoldering and flaming fires fueled by traditional materials and polyurethane while reducing nuisance alarms. It is a reliable, high-quality multi-criteria Photoelectric Smoke Detector and can be used in all open areas where Photoelectric Smoke Detectors are required Optimized reduction to false alarms and enhanced reaction time to real fires High signal-to-noise ratio and sensitivity stability effective in a wide range of environmental conditions Wide viewing angle alarm indicators Automatic drift compensation and maintenance indication Built-in magnetic test feature reak-away, hidden locking feature for use with NS bases Sensing Element Smoke IR LED, Blue LED, Photodiode Supply Voltage Operating Voltage Range 8 – 35VDC Absolute Max Voltage 42VDC Maximum Voltage Ripple 8200mVAC Maximum Input Capacitance 0.01uF Current Consumption Standby Current 59A Minimum Allowable Alarm Current 5mA Maximum Allowable Alarm Current 150mA Startup Time 25s (Max) Current 160A (Max) Reset Time 100ms (Min) Voltage 2.5V (Max) Smoke Density Range 1.82-3.16%/ft@ Open area 1.82-4.55%/ft@300FPM in Duct 1.82-3.96%/ft@1000FPM in Duct 1.82-4.19%/ft@2000FPM in Duct 1.82-4.20%/ft@4000FPM in Duct Detector Compatibility ID HD Compatible Bases NS4-100, NS6-100, NS4-220, NS6-220, NS4-221, NS6-221, NS4-224, NS6-224, HSC-220R, HSC-221R, HSC-224R, HSC-4R, HSC-4R12 *W suffix (not listed above) indicates white color Operating Temperature Range 32F ~ 120F UL Listed Ambient Temperature 32F ~ 120F Storage Temperature Range -22F ~ +140F Operating Humidity Limit <95%RH at 104F, <80%RH at 120F Dimensions 3.94” diameter x 1.77” tall Color SOE-24V – Ivory, SOE-24V (WHT) – White complete all as specified and directed by Engr-in-Charge. Location: Avaro Hanger 1 Avaro Hanger 2 Dornier Hanger Radiography Hanger
S&F in replacement of HOTCHIKI (Existing make) Flame Detectorn: The RFD-2000X UV/IR Flame Detector by REZONTECH responds to light frequencies emitted from flames during combustion. This detector is used to detect flames from burning aviation fuels, butane, grain & feeds, hydrogen, paper, natural gas, and petrol.FM Approved Built-in Ultra Violet and Infrared flame Sensors Explosion Proof (ATEX Ex d IIB + H2) Range of view up to 100ft. (30m) Reduces false alarm by built-in combination filters and signal processing techniques IP67 Rated for water and dust tight protection 4-20mA Output 3 built-in relays (Alarm, Fault & Warning Alarm) Models: RFD-2000X Rated Voltage 17 - 32 VDC Alarm Current 20mA Relay Contact Voltage 28 VDC max. Relay Contact Current 2A max. Detector Output 4-20mA Wiring Gauge 14 AWG - 24 AWG shielded Range of View 100 ft. (30m) Field of View 90° Horizontal & Vertical IP Rating IP67 Operating Temperature -40°C(-40°F) ~ 75°C(167°F) Storage Temperature -50°C(-50°F) ~ 80°C(176°F) Relative Humidity 95%, Non-Condensing Color / Material Metal / Stainless Steel 316 Dimensions 5.3" W x 4.6" H x 4.7" D (134mm x 117mm x 120mm) complete all as specified and directed by Engr-in-Charge. Location: Avaro Hanger 1 Avaro Hanger 2 Dornier Hanger Radiography Hanger
S&F in replacement of HOTCHIKI (Existing make) Repeter Panel: The HFP CP range of conventional fire control panels are high specification, fully featured control units designed for the most demanding of conventional fire detection and alarm system applications.HFP CP is available with 2, 4 or 8 detection zones in standard or installation saving, “2 wire” versions. The extensive range of configuration features available ensure suitability for new installations or panel replacements on older systems.Configuration options are stored in non-volatile memory and are easily accessed via an intuitive user interface which allows the configuration data to be viewed and changed simply and easily. HFP CP control panels are compatible with most standard, conventional detectors, call points and sounders and are also compatible with “2 wire” detector bases from Hochiki. An integral 2 Amp power supply and temperature compensated battery charger provides ample power for the two, 0.5 Amp rated standard sounder outputs, zonal sounder outputs on “2 wire” versions and an auxiliary 24V supply output Construction 1.2mm mild sheet steel IP Rating IP30 Finish Epoxy powder coated Colour - lid & box BS 00 A 05 grey - fine texture Colour - controls plate & labels RAL 7047 light grey - satin Weight 6kg Supply voltage 20-30V DC Mains supply fuse 1.6 Amp 250V Power supply DC rating 24V 1 Amps Maximum battery size 7Ah 12V (2 per panel) Fault contact rating 30V DC1 Amp Fire contact rating 30V DC1 Amp Cable capacity 2.5mm2 per terminal Operating temperature -5°C to +40°C Operating Humidity <95% (non condensing) Dimensions (mm) 385 x 310 x 60 complete all as specified and directed by Engr-in-Charge. Location: Avaro Hanger 1 Avaro Hanger 2 Dornier Hanger Radiography Hanger
S&F in replacement of RAVEL (Existing make) Conventional Panel 2 Zone: Ravel Indian Manufacturer, International standard. Switch Mode Power Supply. Modular Construction, Serviceable. Surface Mount Technology. Battery polarity & deep discharge protection. As per IS -15908: 2011 Standard. 16 X 2 Dot Matrix LCD Display. Standby battery backup with built in charging. Fire / Fault status in unambiguous colored LED indication.Switch Mode Power SupplyTactile Keypad for easy panel operation.System on indication. Main, Standby status indication.Low Battery visual warning with audible tone.Relay output for actuators for Fire and Fault. Lamp Test facilityZone wise one man walk Test Facility.Zone wise Isolation facility with loop voltage cut off.Compatible to all type of Conventional Detectors.Optional Zone Wise Sounder / Zone Wise Contact complete all as specified and directed by Engr-in-Charge.
S&F in replacement of RAVEL (Existing make) Smoke Detector: UL listed.Dual LED’s for 360° visibility.Advanced detection and communication protocol.Easy installation and maintenance.Sleek low-profile housing design.Regular 100mm base. Operating Voltage 9 ~ 33V DC Operating Temperature:-10 °C to 37.8 °C Storage Temperature:-10 °C to 60 °CHumidity:0 – 95% RH, non-condensing Reset Voltage:less than 1VStandby Current:-50 μA Start up Time:60s Start-Up Current:170 μA. Alarm Current:90 mA.(Max). Remote Output:15mA maximum open collector Smoke Sensitivity:(1.96 ± 0.76) % / ftAir Velocity:0 – 4000 fpm.Cycle time:5 Sec Installation Space :5 meters Mechanical Specification Height:46 mm with base Diameter:100 mm dia Weight :130g with base IP Rating:IP – 42 complete all as specified and directed by Engr-in-Charge.
S&F in replacement of RAVEL (Existing make) Manual Call Point: Alarm status is indicated By Red colour LED Operates on 24 VDC. Green Colored for Emergency Release. Yellow Colored for Abort. 1 No’s of CO & NC Output (Optional).Operating Voltage :24VDC Operating Current:30mA Colour:Green / Yellow / Red Material:Plastic IP Rating:IP-50 Size:86 X 86 X 50 mm complete all as specified and directed by Engr-in-Charge.
S&F in replacement of RAVEL (Existing make) Sounder: Slim and Sleek Wall or Ceiling mountable Mini Horn with BackBox 24VDC Operation They are used in Fire, Burglar & Emergency Alarm System. Operating Voltage:24V DC Operating Current:40mA Sound Level:85dB@1m Operating Temperature:0 – 49° C / 32-120° F.Sounder Type :Piezo Electric TypeTone Type:Fire Engine Siren Material :ABS Plastic Colour:Red Dimensions :96 H mm X 76 L mm X 28 D mm Back Box95 H mm X 75 L mm X 58 D mm Mounting Type:Surface / Flush Mount complete all as specified and directed by Engr-in-Charge.
Supply and install in replacement External Wireless Siren Strobe– A Fully Supervised Power Code Outdoor (IP55) Wireless Siren and Strobe Light. Designed For External Installation.Wirefree Connection between Control panel and Siren, Covenient and Rapid No-Mess installation, Separate Fire Alarm Signals, 98db Piezo Siren and High Power Strobe Light , Weather – Resistant IP55 , Two- Way Communication, For Local & Remote Diagnostics, Plug-in Power Supply, NIMH Rechargeable Backup Battery, Transmits Status, Tamper, Low Battery Supervisory and AC Loss Messages to the Control Panel, Tri- State Tamper Switch Identifies Screw Manipulation Removal of Cover or Prying from the Wall complete all as specified and directed. Location : Dornier Hangar, Transmitter bldg, BCR bldg, Avionics Lab, HRDF hut, RT cabin, AFNET, 33 Sqn DWR, ATC Exchange, SRE, CCR, 33 Sqn DSS - 13 Nos.
Supply and fix in repairs of Addressable type Flame detectors with UV/IR detection capacity (add up cost of module to be a complete set, the type of module shall be relay type module complete all as specified and directed by Engr-in-Charge. Loc-Dornier Hangar, 18 Sqn Hanger, Tech flt Hanger, 43 Sqn Hanger
Supply and fixing in replacement of unserviceable battery suitable for smoke detector 3 Volt Alkaline or Lithium Battery complete all as specified and directed.
Supply & fix in repairs of battery maintenance free 12 volt 24 AH complete all as specified and directed by Engineer in Charge.
Supply & fix in repairs of battery maintenance free 6 volt 7 AH complete all as specified and directed by Engineer in Charge.
Supply and fix in replacement of unserviceable RS485 interface module, model : RE-45AR make Ravel suitable for CO2 flooding system installed at SRE bldg complete all as specified and directed.
Supply and fix in replacement of unserviceable release panel model RE-25AR make- Ravel, UL listed (9th Edison), including switch mode power supply, battery polarity and deep discharge suitable for CO2 flooding system installed at SRE bldg complete all as specified and directed.
Supply, installation, testing and commissioning of fault isolator with base with termination preferably after every 20–30 devices and shall be able to isolate electrical short circuit in the wiring etc. complete all as specified and directed.
Supply & fix of 4"x4" MS junction box for detector mounting complete all as specified and directed by Engineer in Charge.
Supply & fix of zone card for fire alarm panel complete all as specified and as directed by Engineer-in-charge
Supply, installation, testing and commissioning of Response Indicators for getting fire indications of detectors installed above false ceiling area interconnecting to loop cable complete all as specified and directed.
Supply, installation, testing and commissioning of Analog Addressable type Active/ Passive Repeater Fire Alarm panel with Backlit LCD Display, having Controls For Reset, Mute, Accept , Silence alarms and Self Test Conforming to BS5839 Standards and Duly Approved by EN54/LPCB/VDS/UL/BSA. complete all as specified and directed.
Supply & fix of addressable type loop card for siemens panel addressable complete all as specified and directed by Engineer in Charge.
Supply & fix of cable 2x1.5 sqmm PVC insulated armoured copper conductor and all fixing arrangements on walls complete all as specified and as directed by Engineer-in-charge. Note : The copper conductor cable of size 1.5sqmm shall be ZHLS/FRLS type.
Supply an fix only of rigid PVC conduit pipe conforming to IS-9537 (Part-III) with all fittings medium duty of size 20mm complete all as specified and directed by Engineer in Charge.
S & F Loop driver card suitable for fire alarm/detection control panel all as specifed and directed by Engr-in-Charge
S & F Internal Printer Module for control panel all as specifed and directed by Engr-in-Charge
S& F in replacement of Neumaric UPS 600 VA, input volt 140V-300V , output voltage 230 Volt, frequency 50 Hz , comunication option 232 UPS for fir alram system all as specifed and directed by Engr-in-Charge
Supply & fixing of in repairs Manual Pull Station along with glass covered box (M.S.) Manual Activation Mechanical all as specified and directed by Engr-in-Charge.
Supply & fixing in replacement of M S Container Strap for mounting and fixing the Agent containers to the wall all as specified and directed by Engr-in-Charge.
Supply & filling in replacement of Gas (1,1,1,2,3,3,3, Hepta fluro propane) Zero ODP stored presure all as specified and directed by Engr-in-Charge.
Supply & fixing in replacement of Brass Discharge Nozzles are designed to provide the proper flow rate and distribution of agent to total flood a hazard area : 180 deg. / 360 deg. End connection - female thread type (NPT / BSPT). all as specified and directed by Engr-in-Charge.
Supply & fixing in replacement of Brass pneumatic actuator allow for pneumatic actuation of slave's cylinder valves in case of master and slave, mounted directly on top of the slave cylinder valve all as specified and directed by Engr-in-Charge.
Supply,Installation,Testing & Commissioning in replacement of Automatic Fire Ext. modular fire extinguisher (Ceiling Mounted)-HCFC123 - 10Kg MS SP Red complete including proper mounting brackets, MS chanels and screw nut bolts etc as required as per specification complete all as specified and as directed by Engineer-in-charge
Supply,Installation,Testing & Commissioning in replacement of Automatic Fire Ext. modular fire extinguisher (Ceiling Mounted)-HCFC123 - 5Kg MS SP Red complete including proper mounting brackets, MS chanels and screw nut bolts etc as required as per specification complete all as specified and as directed by Engineer-in-charge
Supply and filling in replacement of AFFF foam liquid 20 ltrs container filling in fire hydrant foarm sytem all as specified and directed by Engr-in-charge
Archana Enterprises (BID ID -3091673)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .