| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.9 LAccepted-AOC | L1 | Accepted-AOC Being over all reasonable | |
| 2 | L2₹31.6 L+₹90,570 (2.95%)Rejected-Finance OFFICE NO 101 MALAN PLAZA NEXT TO ESSAR PETROL PUMP NEAR GODAMBLE CORNER RAHATNI PIMPRI DP ROAD RAHATANI PUNE 411 017 | PUNE | PUNE | MAHARASHTRA | 411017 | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹32.0 L+₹1.3 L (4.18%)Rejected-Finance 24 25 MANGAL ARCADE TELCO ROAD OPP HOTEL DOUBLE TREE MOHAN NAGAR CHINCHWAD PUNE 411019 | PUNE | MAHARASHTRA | 411019 | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹32.4 L+₹1.7 L (5.38%)Rejected-Finance | L4 | Rejected-Finance Not Lowest Bidder | |
| 5 | L5₹34.8 L+₹4.1 L (13.2%)Rejected-Finance | L5 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹39.5 L
EMD Value
₹78,980
Closing Date
21 Jun 2021, 6:00 pmClosed
GE CENTRAL KIRKEE
GE CENTRAL KIRKEE RANGE HILLS ROAD KIRKEE PUNE 411003
REPAIR MAINT OF CERTAIN INTERNAL WIRING DISTRIBUTION BOARDS AND REPLACEMENT OF CONVENTIONAL HIGH BAY LIGHTS WITH LED HIGH BAY LIGHTS CEILING LIGHTS AND CONNECTED REPAIRS IN VARIOUS BLDGS AT 512 ABWS IN AGE EM II UNDER GE C KIRKEE
2021_MES_445145_1
8479/E8 OF 2021-2022
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
KIRKEE
AS PER NIT
7 documents required · 7 mandatory
₹500
Yes
GE CENTRAL KIRKEE
₹78,980
Yes
12 Jul 2021
24 May 2021
23 Jun 2021
24 May 2021
21 Jun 2021
7 Jun 2021
24 May 2021 - 5 Jun 2021
Amount
Dismantling and Taking out old unserviceable copper/aluminium sub main wiring/Unarmoured cable (used as Sub main wiring) from any height of any Size and Core with all connecting accessories incld. conduit or casing caping and incld. making good to the disturbed wall and painting the same with matching paint as of existing wall including material all as specified and directed by Engineer in charge.
Material & Labour for Sub main wiring at any height with 2 single core PVC insulated, multi stranded copper conductor cable (FRLSH), unsheathed, 2.5 sqmm, 1100 volt grade conforming to IS drawn through and including New 20 mm size steel conduit and including one single core PVC insulated multi stranded unsheathed copper conductor cable, 2.5 sqmm,, FRLSH green in colour as continuous earth wire including all accessories and fixing arrengements, supporting clamps, bends, sockets and connecting items etc. all as specified and directed.
Material and labour for Sub main wiring at any height and surface with and including two single core PVC insulated multi stranded copper conductor cable, conforming to IS, FRLSH type, 4.0 Sqmm, 1100 volts grade, drawn through and including New PVC non metallic conduit 20 mm dia including connected accessories and one single core PVC insulated multi stranded unsheathed copper conductor cable, FRLSH type, 4.0 sqmm, 1100 Volts grade,,green in colour as earth contuinity wire all as specified and directed by Engineer in charge.
Material and labour for Sub main wiring at any height and surface with and including two single core PVC insulated multi stranded copper conductor cable, conforming to IS FRLSH type, 4.0 Sqmm, 1100 volts grade, drawn through and including New 20 mm size steel conduit and including connected accessories and one single core PVC insulated multi stranded unsheathed copper conductor cable, FRLSH type, 4.0 sqmm, 1100 Volts grade,green in colour , as earth contuinity wire all as specified and directed by Engineer in charge. (Note for item No 2 to 4) :- Two runs of cables & continuous earth wire in new PVC casing and caping / PVC non metallic conduit/ steel Conduit will be measured as one length of sub main wiring).
Dismantling and drawing out old unserviceable Sub Main Aluminium/copper wiring from Existing Steel/PVC Conduit of any size and any type from any height with all connecting accessaries (excluding conduit or casing caping) and making good the disturbed wall and painting the same with matching to existing wall including material all as specified and directed by Engineer in charge.
Material and labour Sub main wiring at any height including using two single core PVC insulated copper conductor cable (FRLSH) of size 1.5 sqmm 1100 volt grade conforming to IS drawn through existing Steel/ PVC conduit including 1.5 sqmm. PVC multi stranded copper conductor cable (FRLSH) green in colour for continuous earthing all as specified and directed.
Material and labour Sub main wiring at any height including using two single core PVC insulated copper conductor cable (FRLSH) of size 2.5 sqmm 1100 volt grade conforming to IS drawn through existing Steel/ PVC conduit including 2.5 sqmm. PVC multi stranded copper conductor cable (FRLSH) green in colour for continuous earthing all as specified and directed.
Material and Labour for Sub main wiring at any height with four single core PVC insulated copper conductor cable (FRLSH) of size 6 sqmm 1100 volt grade conforming to IS drawn through Existing Steel / PVC conduit including two single core 6.0 sqmm PVC multi stranded copper conductor cable (FRLSH) green in colour for continuous earthing all as specified and directed. (Note for item No 2 to 8) - (a). Two/Four runs of wiring cable and One/two runs of earth continuity wire shall be measured as one length.
Disconnecting and taking down old existing damaged metallic rigid steel conduit of any size and any type from any height with all fittings complete.
Supply & fixing hot galvanised rigid steel conduit 25 mm dia, light grade, at any height with and incld. of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks, screws, clips, plugs, clamps etc. for securing , conduits etc. to walls,ceiling, steel joists etc. complete all as directed by Engr-in-Charge.
Supply & fixing hot galvanised rigid steel conduit 20 mm dia, light grade, at any height with and incld. of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks, screws, clips, plugs, clamps etc. for securing , conduits etc. to walls,ceiling, steel joists etc. complete all as directed by Engr-in-Charge.
Disconnecting and taking down old switch fuse type distribution Box with MCB/fuse grip TPN/SPN DB 2 Way to 12 Way old type DB including taking out all cable connections of any description and in any position and M&L for making good the disturbed surface of walls, to match with the existing surfaces complete all as specified and directed by Engineer in charge.
S&F, connecting & testing of VTPN DB of 12 way suitable for MCCB up to 160A as a incomer & SP / TP MCB as a outgoings with IP 43 -IK09 as conforming to IEC 61439-3 & made of high quality CRCA sheet shall have integrated door earthing system, shall have reversible door facility, ergonomic design with rounded corners to protect against damage like bending, peeling of paint hence preventing rusting. DB shall be with Insulated Busbar with withstand capacity of 36kA, shrouded neutral bar, Door earthing, corner Safe. wiresets, shrouded Neutral bar, earth bar & wire ties, all as specified & directed. Note : MCCB, MCB will be measured and paid separately under relevant item of this schedule.
S&F, connecting & testing of VTPN DB of 8 way suitable for MCCB up to 160A as a incomer & SP / TP MCB as a outgoings with IP 43 -IK09 as conforming to IEC 61439-3 & made of high quality CRCA sheet shall have integrated door earthing system, shall have reversible door facility, ergonomic design with rounded corners to protect against damage like bending, peeling of paint hence preventing rusting. DB shall be with Insulated Busbar with withstand capacity of 36kA, shrouded neutral bar, Door earthing, corner Safe. wiresets, shrouded Neutral bar, earth bar & wire ties, all as specified & directed. Note : MCCB , MCB will be measured and paid separately under relevant item of this schedule.
S&F, connecting & testing of VTPN DB of 4 way suitable for MCCB up to 160A as a incomer & SP / TP MCB as a outgoings with IP 43 -IK09 as conforming to IEC 61439-3 & made of high quality CRCA sheet shall have integrated door earthing system, shall have reversible door facility, ergonomic design with rounded corners to protect against damages like bending, peeling of paint hence preventing rusting. DB shall be with Insulated Busbar with withstand capacity of 36kA, shrouded neutral bar, Door earthing, corner Safe. wiresets, shrouded Neutral bar, earth bar & wire ties, all as specified & directed. Note : MCCB, MCB will be measured and paid separately under relevant item of this schedule.
S&F, connecting & testing SPN DBs of 8 way for using MCBs / MCB isolators suitable for single pole and neutral, with IP 43 -IK09 as conforming to IEC 61439-3 & made of high quality CRCA sheet shall have integrated door earthing system, shall have reversible door facility, ergonomic design with rounded corners to protect against damages like bending, peeling of paint hence preventing rusting. DB shall be with Insulated Busbar with withstand capacity of 10kA, shrouded neutral bar, Door earthing, corner Safe. wiresets, shrouded Neutral bar, earth bar & wire ties, all as specified & directed.
S&F, connecting & testing SPN DBs of 12 way for using MCBs / MCB isolators suitable for single pole and neutral, with IP 43 -IK09 as conforming to IEC 61439-3 & made of high quality CRCA sheet shall have integrated door earthing system, shall have reversible door facility, ergonomic design with rounded corners to protect against damages like bending, peeling of paint hence preventing rusting. DB shall be with Insulated Busbar with withstand capacity of 10kA, shrouded neutral bar, Door earthing, corner Safe. wiresets, shrouded Neutral bar, earth bar & wire ties, all as specified & directed.
S&F, Thermal magnetic adjustable MCCB 160 Amps 4 pole with breaking capacity 25 KA & shall be Ics=Icu 100%, complete all as specified and directed.
S&F, Thermal magnetic adjustable MCCB 100 Amps 4 pole with breaking capacity 25 KA & shall be Ics=Icu 100%, complete all as specified and directed.
S&F, Thermal magnetic adjustable MCCB 63 Amps 4 pole with breaking capacity 25 KA & shall be Ics=Icu 100%, complete all as specified and directed.
Supplying & fixing MCB 6 to 32 Amps, single pole and neutral, "C" curve 10 kA breaking capacity with integrated label holder, sliding bottom clamp, color coded On/Off indication on dolly complete all as specified and directed.
Supplying & fixing MCB 6 to 32 Amps, single pole, 10 kA breaking capacity with integrated label holder, sliding bottom clamp, color coded On/Off indication on dolly, complete all as specified and directed.
Removing of old HPMV / MH high bay light fittings at 12 to 15 mtr height carefully without dammaging connector or ceiling rose. If any damage made to the government property the same shall be repaired by the contractor without any extra cost.
Supply and fixing at height 9 to 15mtr 150W LED high bay made from pressure die cast aluminium with minimum system efficiency > 18000 lm (130 lm/w) using LEDs with efficiency 140 lm/w and life of > 50000 burning hrs. LEDs should be mounted on MCPCB LEDS should have CRI> 70 and CCT of 5700K +/- 300K LED should have 120 degree beam angle luminaire should be provided with isolated vibration proof heavy duty potted drivers with 4kv on board surge protection and 10kv external surge protection . efficiency of drive should be >85% operating voltage should be rating between 100V-300V with under voltage and over voltage protection at 320V. Driver should sustain 440V or8hrs power factor should be 0.95 and THD should be < 10% driver should be EMC complaint. Driver heat sink material should be aluminium extrusion SELV protection and electrical safety of class 1 to be provided optical should be polycarbonate lens screwed to the MCPCB for better strength with 60-90 degree beam angle luminaire should be IP66 luminaire should comply to IS10322 Part5-sec3 and BIS registered with R number operating temperature 0-50 deg C Mounting should be with eyebolt. LM79 report from NABL accredited lab and LM80 report from LED manufacture to be provided to Engineer-in-Charge. NOTE :- The quoted rates are deemed to be included the cost of Nut-bolts washars or clamps required to be replaced if old one are found unserviciable or of differant size/shape for completion of work.
Removing of old main switch after disconecting the incoming and out going cables and supply and fix MCCB thermal magnetic release four pole 25 KA 63 Amps with one way metal inclosure and making conections of cables with suitable size nutbolt etc including making good the disturbed suface of wall including material complate all as specifide and directed.
Removing of old main switch after disconecting the incoming and out going cables and supply and fix MCCB thermal magnetic release four pole 25 KA 100 Amps with one way metal inclosure and making conections of cables with suitable size nutbolt etc including making good the disturbed suface of wall including material complate all as specifide and directed.
Removing of old main switch after disconecting the incoming and out going cables and supply and fix MCCB thermal magnetic release four pole 25 KA 160 Amps with one way metal inclosure and making conections of cables with suitable size nutbolt etc including making good the disturbed suface of wall including material complate all as specifide and directed.
Removing of old main switch after disconecting the incoming and out going cables and supply and fix Industrial plug and socket board TP 32 Amps including plug top and MCB "C" curve 10 KA 32 Amps and making conections of cables with suitable size nutbolt etc including making good the disturbed suface of wall including material complate all as specifide and directed.
Removing of old main switch after disconecting the incoming and out going cables and supply and fix one way metal inclosure and MCB "C" curve TPN 10 KA 32Amps and making conections of cables with suitable size nut bolt etc. including making good the disturbed suface of wall including material complate all as specifide and directed.
Taking down carefully existing unserviceable aluminum / copper point wiring of any description & in any position with and including existing steel conduit / PVC Conduit / Casing caping fixed on surface/wall/angle/gardder and including all fitting, accessories & fixtures such as switches, ceiling roses, pendants, regulators, sockets, etc including sunken boxes/junction boxes and making good the disturbed surface of walls, floors, ceiling etc to match with the existing surfaces complete all as specified and directed.
M&L for point wiring in non metallic PVC coduit of suitable size but not less than 20mm including all fittings such as elbow, bends, junction boxes, saddles, etc. on surface with and including ISI marked two runs of PVC insulated unsheathed multistranded copper conductor cable (FRLSH) 1.5 sqmm nominal cross sectional area, 1100 volts grade and including one run of 1.5 sqmm (green colour) ISI marked PVC insulated unsheathed multistranded (FRLSH) copper conductor cable as earth wire to be terminated in and incl PVC rectangular block of suitable size for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover for one light point or one fan point controlled by one switch including making good the disturbed wall and painting the same with matching to existing wall all as specified and directed by Engineer in charge.
All as per Srl item No 31 above but point wiring for 5 pin socket outlet, 5 Amps on same board with other switches.
All as per Srl item No 31 above but point wiring for 5 pin socket outlet, 5 Amps on independent board.
All as per Srl item No 31 above but point wiring for one five pin socket outlet, 15 Amps & 5 Amp on independent board using 2.5 sqmm two run and one run 2.5 sqmm (nominal area) stranded copper conductor cable.
M&L for point wiring in non metallic white coloured PVC casing & caping of suitable size but not less than 20mm including all fittings such as elbow, bends, junction boxes, saddles, etc. on surface with and including ISI marked two runs of PVC insulated unsheathed multistranded copper conductor cable (FRLSH) 1.5 sqmm nominal cross sectional area, 1100 volts grade and including one run of 1.5 sqmm (green colour) ISI marked PVC insulated unsheathed multistranded (FRLSH) copper conductor cable as earth wire to be terminated in and incl PVC rectangular block of suitable size for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover for one light point or one fan point controlled by one switch including making good the disturbed wall and painting the same with matching to existing wall all as specified and directed by Engineer in charge.
All as per Srl item No 35 above but One bell/buzzer point controlled by one push button on the same board with other switches or independent with cables1.5 sq.mm. Size.
All as per Srl item No 35 above but point wiring for 5 pin socket outlet, 5 Amps on same board with other switches.
All as per Srl item No 35 above but point wiring for 5 pin socket outlet, 5 Amps on independent board.
All as per Srl item No 35 above but point wiring for one five pin socket outlet, 15 Amps & 5 Amp on independent board using 2.5 sqmm two run and one run 2.5 sqmm (nominal area) stranded copper conductor cable.
Material and labour for point wiring for one light/ fan/ bell point controlled by one switch in and including steel conduit with and including all steel enamelled fittings such as elbow bends, junction boxes, supporting clamps for proper hanging arregements made out from 20x1mm flat aluminium patti including nuts, bolts and bending to shape etc. of appropriate size but not less than 20mm on surface with two run of PVC insulated unsheathed multistranded copper conductor cable (FRLSH) 1.5 Sqmm nominal cross sectional area 1100 volts grade and including one run of 1.5 sqmm (green colour) PVC insulated unsheathed multistranded (FRLSH) copper conductor cable as earth wire incl. suitable size sunken type Galvanised pressed sheet steel 1.6 mm thick terminal box of suitable size with 3 mm thick laminated hylum sheet for mounting switches, sockets etc. and making good the disturbed wall and painting the same with matching colour of the existing wall, incld material all as specified and directed.
All as per Srl item No 40 above but point wiring for 5 pin socket outlet, 5 Amps on same board with other switches.
All as per Srl item No 40 above but point wiring for 5 pin socket outlet, 5 Amps on independent board.
All as per Srl item No 40 above but point wiring for one five pin switch socket outlet combination, 15 Amps & 5 Amp (independent) with using 2.5 sqmm two run and one run 2.5 sqmm (nominal area) stranded copper conductor.
Supplying & fixing switch flush type, 5 Amps, single pole, one way, 230 volts AC circuit complete all as specified & directed.
Supplying & fixing switch flush type, 5 Amps, Bell push, flush type, 230 volts AC circuit complete all as specified & directed.
Supplying & fixing socket outlet, five pin, 5 Amps, flush type, multipurpose, 230 volts AC circuit complete all as specified & directed.
Supplying & fixing switch flush type, 15 Amps, single pole, one way, 230 volts AC circuit complete all as specified & directed.
Supplying & fixing Socket outlet 2 in 1, 3 pin, 5 and 15 amp flush type, flush type, 230 volts AC circuit complete all as specified & directed.
Supplying & fixing ceiling rose PVC/polycarbonate, isolated body, three terminals, complete all as specified & directed.
Supply and fixing in replacement Stepped type electronic fan regulator flush type suitable for ceiling fans, prewired 230 volts AC 50Hz supply 100Watt complete all as specified & directed.
Supply, fixing, connecting and testing in replacement Industrial Earth Plug & socket with sheet metal enclosure of IP44 rating electric driven single phase including MCB 'C' series SP 20 Amps and supplied with neutral links complete all as specified and directed.
Supply, fixing, connecting and testing in replacement Industrial Earth Plug & socket with sheet metal enclosure of IP44 rating electric driven three phase including MCB 'C' series TP 20 Amps and supplied with neutral links complete all as specified and directed.
M & L for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending colt or hot, drilling holes for bolts, at any height, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint for mounting Air Circulator / Exhaust Fan / Ceiling Fan for fixing arrangements complete.
Dismantling and Taking down unserviceable existing light fittings 1X 40 Watt / 2X 40 Watt/ 70 watt or any other wattage security lihgts of any size and capacity from any location/height after disconnecting of electrical connection complete including all connected accessories all as directed by Engr-in-Charge.
Supplying, fixing, connecting up to existing/new ceiling rose and testing industrial box type batten with precoated CRCA body. LED tube light fitting suitable for and including 1x20 Watt 4 feet long tube with polycarbonate diffuser ,LED lamp efficay -110 Lum/W ,THD ≤15% with operating voltage range 100-300V, driver efficency >85%, surge voltage withstand 2.5 KV , power factor ≥0.9 including connecting with 23/0.0076 copper conductor flexible twisted three core cable including all accessories for fixing on steel trusses / false ceiling / ceing suspended by 2 nos. Ø19/20 mm dia rigid stove enamelled black steel conduit 0.50 to 0.75 mtrs length with bell mouth threaded sockets or with chains at a distance of 700mm complete including dismantling of old fittings all as specified & directed.
Supplying, fixing, connecting in at any height up to existing/new ceiling rose and testing LED luminarie made up of precoated CRCA housing provided with cum reflector finished in white powder coating, completely prewired with accessories up to terminal block suiatble for 2x20W 4 feet long LED tubes(High Lumen-110 Lumen/Watt) and including connecting with 23/0.0076 copper conductor flexible twisted three core cable and fixing arrangements for fixing on steel trusses / false ceiling/ ceiling suspended by 2 nos. Ø19/20 mm rigid stove enamelled black steel conduit 0.50 to 0.75 mtrs length with bell mouth threaded sockets or with chains at a distance of 700mm complete including dismantling of old fittings all as specified & directed. Note for item No 55 and 56 -1 ; Stove enamelled black steel conduit or cahin only will be measured and paid under relevant items of this schedule. 2 ; Quoted rate is deemed to be inclusive of conduit fittings and bell mouthed threaded sockets.complete all as specified & directed. 3 ; Quoted rate is deemed to be inclusive any misc materials required for fixing new luminaries.
Supplying, fixing, connecting in at any height up to existing/new ceiling rose and testing LED batten with 20 W LED light source in integral module with polycarbonate/Acrylic diffuser more than 85%efficiency of light with LED lamp efficay as 110 Lum/W THD ≤15% with operating voltage range 100-300V, driver efficency >85%, surge voltage withstand 2.5 KV , power factor ≥0.9, and connecting with 23/0.0076 copper conductor flexible twisted three/ two core cable fittings conection complete all as specified & directed. NOTE - Quoted rate is deemed to be inclusive of any misc materials required for fixing new luminaries.
M/S. Niksun Electro-Infra Private Limited
metro electrical services
M/S. OM ENTERPRISES
KSP ENTERPRISES
AN-ICON Engineering Technologies And Infrastructure Developments Pvt. Ltd
R. T. Saluji
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .