Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹54.5 LAccepted-AOC GROUND FLOOR ASHFAQ HUSSAIN AL ABASS A S RELIEF TRUST BUILDING KARAN NAGAR SRINAGAR 91495 SRINAGAR JAMMU AND KASHMIR 190010 | SRINAGAR | JAMMU AND KASHMIR | 190010 | L1 | Accepted-AOC Lowest Bid | |
| 2 | L2₹66.4 L+₹11.9 L (21.9%)Rejected-Finance | L2 | Rejected-Finance Higher bid | |
| 3 | L3₹73.2 L+₹18.7 L (34.3%)Rejected-Finance 1ST FLOOR HRECF OFFICE NEAR JNV SCHOOL MIAN GATE TIA RAY RONG CHOGLAMSAR LEH LADAKH 194101 | LEH LADAKH | LADAKH | 194101 | L3 | Rejected-Finance Higher Bid | |
| 4 | L4₹2.3 Cr+₹1.8 Cr (324.2%)Rejected-Finance 0 S F ENTERPRISES CHANDAK CHANDAK POONCH POONCH JAMMU KASHMIR 185101 UDYAM JK 14 0008974 | POONCH | JAMMU AND KASHMIR | 185101 | L4 | Rejected-Finance Higher Bid | |
| 5 | Rejected-Technical | - | Rejected-Technical Not submitted all document |
Tender Value
Refer Docs
EMD Value
₹99,200
Closing Date
10 Sept 2024, 1:00 pmClosed
Executive Engineer STD Leh
Executive Engineer STD Leh
Supply, Installation, Erection, Testing and Commissioning of Additional 11KV VCB Panel and Cable trench at 1X6.3MVA, 66/11KV Substation Lungmar Leh.
2024_PDNRE_13915_1
e NIT No STD Leh 07 of 2024 25
Open Tender
Electrical Works
Turn-key
90 days
Lungmar Leh
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,000
Executive Engineer STD
₹99,200
Executive Engineer STD Choglamsar Leh
5 Oct 2024
29 Aug 2024
11 Sept 2024
30 Aug 2024
10 Sept 2024
3 Sept 2024
2 Sept 2024 - 5 Sept 2024
2 Sept 2024
Amount
Supply and erection
11kv VCB Panel (12KV , 26.3kA for 1 Secs., 1250A, 500MVA rupturing capacity ) indoor VCB switchgearpanel 24V DC operated with required PTs, CTs, protective relays, metering equipment, auxiliary equipment, extensible (both sides) copper busbars, complete cable termination Kits complying IEC 62271-200 & 100 and IS 13118(1991) and all relay shall be of numerical type with suitable for IEC 61850 protocol as per technical specification. 1. 1250A Incoming feeder = 1 Nos. for each transformer Core-1:600-300 / 5A Cl-0.2s, 15 VA, ISF=<5 Core-2: 600-300/5A, 5P20, 15 VA Core-3: 600-300/5A, PS To be provided with one Tri-vector meter on each incomer and outgoing 2. 400 A outgoing feeder = 5 Nos Core-1: 200-100/5A Cl- 0.2s, 15 VA, ISF=<5 Core-2: 200-100/5A 5P10, 15 VA 3.1250 A Buscoupler with adapter panel = 1 Nos., CTR : 600-300/5-5 A, 2 Core Refer CT design parameters as per technical specifications. ( Note: The complete inter connection of panels alongwith existing panels included in the scope)
Earthing complete set for Panels ( chemical)
Rubber mats for control room building near 11 kv panels as per voltage rating requirement conforming to IS-15652 with latest amendments (complete running set)
11KV , 3 Core 185sqmm, Al condcutor, XLPE insulated, PVC Sheathed, Armoured PVC Outer Sheath cable for 11KV outgoing panels to 11KV double pole with FRLS features
11KV outdoor termination kits (3Cx185sqmm)
11KV indoor termination kits (3Cx185sqmm)
Trench Work
Demolishing cement concrete manually/mechanical means including disposal of materials within 50 mtrs lead as per direction of engineer incharge 15 2.1 1:3:6 or richer mix ( i/c equivalent design mix)
Demolishing brick work manually/by mechanical means including stacking of serviceable materials and disposal of unserviceable material within 50 mtrs lead as per direction of engineer incharge: in cement mortar
EARTH WORK
Earth work in excavation by mechanical means (hydraulic excavator) in trenches for Foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts,wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres:2.9.1 all kind of soil
Earth work in excavation by manual means in trenches for foundation,drains, pipes, cable etc ( not exceeding 1.5M in width) and for shafts,wells,cesspits and the like not exceeding 10 sqm on ramming of bottoms lift upto 1.5m , including getting out excavated earth and disposal of surplus excavated earth as directed, all kind of soil.
SOILING/PCC
Soiling including cost of stone
Providing and laying in position cement, cencreate of specified grade including curing but excluding the cost of centering and shuttering. All work upto plinth level with 1:4:8 ( one cement : 3 coarse sand: 6 graded stone aggregate 20mm nominal size
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with. 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 40mm nominal size).
Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering/shuttering/finishing and reinforcement. All works upto plinth level 1:1 1/2:3 ( one cement: 1 1/2 coarse sand : 3 graded stone aggregate 20mm nominal size)
Steel reinforcement for RCC work including straightening, cutting, bending,placing in position and binding all complete upto plinth level six thermo mechanically treated bars of grade 5000 or more @90kg/cum
CENTERING & SHUTTERING
Centering and shuttering including strutting,propping etc and removal of form work for 4.6.1 foundation,footing,basis for columns
Providing & fixing upto floor five level precast cement concrete solid blocks including hoisting and setting in position in cement mortar 1:3 (1cement:3 coarse sand), cost of required centring, shuttering and curing complete 1:3:6 (1 cement : 3 coarse sand : 6 graded crushed stone aggregate 20 mm nominal size)
WALL PLASTER - CEMENT PLASTER (IN FINE SAND) 12mm Cement plaster of mix:1 : 4 ( 1 cement : 4 fine sand) Exterior/interior
Finishing wall with water proofing cement paint of required shade on new work (two or more coats [email protected]/10sqm)
providing and applying plaster of paris putty of 2mm thichness over plastered surface to prepare the surface even and smooth complete
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on new work (two or more coats) over and includeing priming coat with water thinnable cement primer
Steel Section
Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works : QTY.: chequered plate @ 56.148kg/sqm inside the control room, 40x40x5 along the periphery of the trench cover,wall mounted cable holder to be placed at one side or both side of the trench at 1m distance
Carriage of material by MT from source to site of work including loading, unloading complete job
Cement and steel ....5km,sand....10km, stone aggregate,soiling
M/S LADAKH HIMALAYAN RENEWABLE ENERGY (BID ID -134259)
HIMALAYAN RENEWABLE ENERGY AND CONSTRUCTION FIRM (HRECF) (BID ID -134271)
M/s S. F. ENTERPRISES (BID ID -134294)
stage.html
html • 0.05 MB
tech_eval.pdf
PDF • 0.33 MB
boq_comp_chart.xlsx
xlsx • 0.01 MB
fin_eval.pdf
PDF • 0.26 MB
aoc.pdf
PDF • 2.17 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .