Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.7 LAccepted-AOC 10 2 NARAYAN BAG INDORE M P | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹26.0 L+₹4,918 (0.19%)Rejected-Finance | L2 | Rejected-Finance BEING L2 |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
13 Nov 2021, 6:00 pmClosed
GE (MIS) MHOW
GARRISON ENGINEER (MAINT) INF SCHOOL MHOW
REPAIR MAINT OF SOLAR WATER HEATER GYSERS AC WATER COOLER OXYGEN PIPE LINE AND OTHER CONNECTED WORKS UNDER GE MI) MHOW
2021_MES_481041_1
8428/GE (MIS) /Mhow
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (MIS) MHOW
as per tender documents
8 documents required · 8 mandatory
₹500
GE (MIS) MHOW
₹70,000
Yes
22 Dec 2021
12 Oct 2021
15 Nov 2021
12 Oct 2021
13 Nov 2021
30 Oct 2021
Amount
REPAIRS TO SOLAR WATER HEATER:
M & L in Replacement of Gl tubing medium grade 15mm bore with fitting , fixed to walls and ceilings or laid in floors complete all as specified and directed Make- Tata, Swastik, Jindal, Prakash, Surya.
S&F in replacement of GI coupling union 15 mm bore, ISI marked complete.
S&F Bib taps 15 mm , chromium plated fancy type cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed down,screwed for iron pipe or for unions and fixed.
S&F Stop valves 15 mm , chromium plated fancy type cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed.
S&F in replacement of 16 mm external dia Chlorinated Poly Vinyl Chloride (CPVC) pipe consisting of high grade polymer effectively bonded in the inside and outside of an aluminium tube CPVC-AL-CPVC by melt adhesive(including joining/fixing with cement solvent) suitable for hot water supply from solar water heater to the bathrooms and fixed to wall, ceiling etc. including all materials, fittings and fixing works and testing of pipe line test for solvent cement joints and adhesive joints and testing of all materials shall be as per manufactures instructions, literature and confirming to IS-15450 : 2004 or ASTM -1282 including making good the disturbed surfaces complete all as specified and directed.
Repair the unserviceable solar water heating system and de-scaling with auth agent and making serviceable by filling the Distilled water, cleaning the solar toughned glass, stopping the leackage with replacing the old unserviceable CPVC pipe/tee/bend/broken glass tubes etc. complete all as specified and directed. Note 1:- Distilled water, CPVC pipe /glass tubes,CPVC acessories will be measured and paid saperately in respective item. Note2 :- The contractor ensure that all materials/spares once the incorporated in the work, they should maintain warranty for the same through the contract period from the date of executing.
Supply only Distilled water in the Solar water Heating systems at different location and distilled water will be filled in existing distilled water pot connected on solar tank complete all as specified and directed at site Note :- Distilled water will be supplied in sealed containers.
S&F in replacement of heating element thread type 3.0 KW and fixed at solar water heater tank complete with 9" long thermostate veriable type complete with ISI Mark.As approved by GE
Taking down carefully existing storage type water heater (Geysers) of any make and capacity (25/50 litres) including disconnecting water connection (inlet and outlet) for repairing/painting etc and refixing the same and connecting up after cleaning, repairing & painting complete. Note 1 : (a) Defect developed while taking out the geysers, such as leaking of joints, damaging of thread of pipe/geyser and other GI fittings such as elbow, nipple, union, socket, etc shall be rectified/replaced by the contractor at his own cost. (b) Replacing the PVC connection, Heating element,thermostate and painting work shall be measured & paid separately. Note 2 :- The contractor ensure that all materials/spares once the incorporated in the work, they should maintain warranty for the same through the contract period from the date of executing.
M&L for Scrapping the old painted surfaces of geyser, cleaning and painting with two coats of white synthetic enamel paint over & including a coat of red oxide primer including writing MES No. with black paint with minimum 25 mm size of letters all as directed at site for 25 liters capacity geysers complete.
M&L for Taking out geyser inner tank from geyser body, 25 liter capacity making the tank leak proof by necessary brazing/welding work, repair to collar, testing for leakage and fixing back to the body with collar gasket complete.
All as per item No. 11 hereinbefore but geyser 50 liter capacity complete.
S&F in replacement of geyser inner tank made out of stainless steel sheet, minimum weight 1.20 kg suitable for 25 liter capacity geyser, including ‘O’ ring, coupling set, necessary drilling work, nuts, bolts, washers, etc complete.
All as per item No. 13 but suitable for geyser of capacity 50 liter and weight not less than 1.70 kg complete all as specified and directed at site.
S&F in replacement of apparatus plate assembly of brass complete with collar, gasket, in let, out let and housing for heating element, thermostat, thermal cut out and fixed to geyser of 25 liters capacity, including necessary drilling work, nut, bolts, washers etc complete.
All as per item No 15 but of 50 litres capacity geyser complete.
M&L for Checking the unserviceable geyser and making serviceable by replacing the thermostate/heating element, PVC connection etc as per site requirement and tightening the connection, adjusting the thermostat, checking the power point of geyser and making servicing by tightening/replacing screws/ replacing the small piece of wire, etc. complete.
Note 1 :- (a). Petty stores like insulation tape, screws, small piece of cable, etc shall be provided by the Contractor without any extra cost to the department.
(b). Replacing the PVC connection, Heating element and thermostate shall be measured & paid separately. Note 2 :- The contractor ensure that all materials/spares once the incorporated in the work, they should maintain warranty for the same through the contract period from the date of executing.
S&F heating element push type 1.5 KW ISI Marked complete all as specified and directed .
All as per item No. 18 but 2 KW capacity complete all as specified and directed .
Supply only heating element triangle type 1.5 KW ISI Marked complete all as specified and directed .
All as per item No. 20 but 2 KW capacity complete all as specified and directed .
Supply only heating element thread type 1.5KW with ISI Mark complete all as specified and directed .
All as per item No. 22 but 2 KW capacity complete all as specified and directed .
S&F geyser thermostat of ISI marked, suitable for 20 degree to 80 degree centigrade in 25/50 liter capacity geyser complete all as specified and directed .
S&F safety valve, vertical type made out of brass chromium plated, size 15 mm, heavy duty complete.
S&F non return valve, vertical type, made out of brass suitable for 15 mm GI pipe including cutting & threading of G.I. pipe and G.I. fittings such as socket, union, elbow, nipple, etc complete.
S&F PVC connection hot water grade 18” long 15 mm dia with two Nos coupling nut of brass, heavy duty, complete.
Supply only PVC connection hot water grade 24” long 15 mm dia with two Nos coupling nut of brass, heavy duty, complete.
S&F in replacement Heavy duty water connection pipe (Flexible steel) 18” long and 15 mm dia with two Nos coupling nut of brass, heavy duty, complete.
S&F in replacement of indicating lamp, round shape, red/green colour with connecting lead suitable for AC 230 volts complete.
S&F in replacement of indicating lamp, rectangular shape, red/green colour with connecting lead suitable for AC 230 volts complete.
Supply and fixing in replacement bottom base covers of geysers 25 ltr capacity in two halves duly painted with white colour including screws, nut bolt if required complete all as directed at site.
S&F in replacement of flexible copper wire 3 core PVC insulated and PVC sheathed size 2.5 Sqmm X 3 core complete (Make : Plaza/ Finolex/ Sieko/ ISI marked).
S&F in replacement of metal clad plug two pole with earth terminal capacity 20 Amps complete in existing single pole and neutral enclosure.(Make: HPL cat No. HP2P20 or equivalent in Standard/ Havell's/HPL)
S&F in replacement of metal clad socket two pole with earth terminal capacity 20 Amps complete in existing single pole and neutral enclosure.(Make: HPL cat No. HP2S20 or equivalent in Standard/ Havell's/HPL)
S&F in replacement of MCB single pole 6 to 20 Amps, 230 volts 'C' series, 10 KA breaking capacity complete.
S&F in replacement of MCB single pole and neutral 40 Amps, 230 volts 'C' series, 10 KA breaking capacity complete.
S&F in replacement of glass wool in 25/50 liter capacity geyser by taking out inner & outer tank and reassembling complete.
S&F in replacement of sheet metal enclosure with socket plug two pin and earth plug top and complete with single pole MCB of 20 Amps capacity complete all as specified and directed. Make:- Havells/Legrand/HPL
S&F in replacement of sheet metal enclosures 2 way, 240 volt for DBs (single door) suitable for MCB SPN, complete all as specified and directed
S&F in replacement of sheet metal enclosures 4 way, 240 volt with 200 Amp rated bus bar for DBs (double door) , complete all as specified and directed
S&F in repairs MCB TPN, 415 volts, 40 Amps, 10KA breaking capacity, 'C' type including connection with suitable size almuminium/copper lugs complete all as directed.
M&L in repair earthing complete with galvanised steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground vertically to a depth not less than 2.25m below ground level with top edge of the earth plate at a depth not less than 1.5m below ground level earth plate surrounded by and packed with 15cm thick layer of char coal dust and common salt earth lead GI wire 4.00mm dia by means of volts, nuts, check nuts and washers of galvanised iron and thimble and other end of earth wire connected to main switch board and protected by galvanised iron pipe light grade 15mm bore and water pipe 20mm bore GI light grade with funnel and wire mesh PCC chamber in cement in cement concrete 1:3:6 type C-2 and RCC cover all as specified and shown in elect plate No 3 of SSR Part-I of 2009. Note:- (i) Earth lead beyond 7.5 m from electrode to earth terminal point shall be measured seperately (ii) If desired results are not met on testing the earthing will be redone at no extra cost.
M&L for earth continuity conductor 4 mm dia GI earth lead wire fixed to equipments or any other indicated situation complete all as specified and directed.
M&L plug top, 3 pin 15 Amp, SP, 230 V fixed in repairs complete
M&L switch socket combination piano type 5/15 Amp, 230 V fixed in repairs complete
Supply and fxing in replacement of solar collector plate with touch end glass size 1 x 4 M and 4 mm thick fixed on solar collector complete all as site requirement and directed by Engr-in-charge.
S & F in replacement of 100 LPD Puf insulated stainless steel hot water storage tank for 100 LPD solar water heater storage tank material 316 grade stanless steel outer clading material powdar coated GI sheet with inlet and outlet water connections. complete all as per site requirement and directed by Engr-in-charge.
S & F in replacement of 200 LPD Puf insulated stainless steel hot water storage tank for 200 LPD solar water heater storage tank material 316 grade stanless steel outer clading material powdar coated GI sheet with inlet and outlet water connections. complete all as per site requirement and directed by Engr-in-charge.
S & F in replacement of 300 LPD Puf insulated stainless steel hot water storage tank for 300 LPD solar water heater storage tank material 316 grade stanless steel outer clading material powdar coated GI sheet with inlet and outlet water connections. complete all as per site requirement and directed by Engr-in-charge.
S&F in replacement of anti rust ring for 1500 x 47 mm size special grade borocilicate glass tube complete all as specified and directed,
S&F silicon ring for 1500 x 47 mm size Tata BP special grade borocilivate glass tube complete all as specified and directed,
S&F plastic tube holder for 1500 x 47 mm size Tata BP special grade borocilivate glass tube complete all as specified and directed,
S&F in replacement of brass elbo suitable for CPVC pipe line of size 16 mm complete jointing etc all as specified and directed.
S&F in replacement of brass elbo suitable for CPVC pipe line of size 20 mm complete jointing etc all as specified and directed.
S&F in replacement of brass Tee suitable for CPVC pipe line of size 16mm complete jointing etc all as specified and directed.
S&F brass in replacement of Tee suitable for CPVC pipe line of size 20 mm complete jointing etc all as specified and directed.
S&F in replacement of Female brass threaded adopter suitable for CPVC pipe line of size 16mm complete jointing etc all as specified and directed.
S&F in replacement of Female brass threaded adopter suitable for CPVC pipe line of size 20mm complete jointing etc all as specified and directed.
S&F composite pressure pipe of size 32 mm inner dia and 40 mm outer dia including necessary connection and required accessories such as elbows,tees, reducers, couplers, short pieces,connectors etc. complete all as specified and directed by Engr-in-Charge. Make Kitec
S&F Rotational moulded PVC water storage tank (Cylindrical vertical with closed top) hoisted and fixed in position of capacity 500 ltrs complete all as directed at site.
S&F of sub main wiring with two runs of single core PVC insulated and unsheathed multistranded, copper conductor cable of size 4.00 sqmm LT, 1100 volts grade, drawn through and including 25 mm dia PVC non metallic conduit with accessories such as socket, elbow, junction box, bell mouth, reducer, bend and flexible conduit etc. and fittings and one run of 4 sqmm single core multistranded copper conductor cable green colour as earth continuity conductor. Note:- (i) Two runs of cable one run of earth wire and one run of PVC non metallic conduit of 25mm dia shall be measured as one run lenght. (ii) Cable required for connection to DBs shall deemed to be included and shall not be measured seperately. (iii) Earth wire shall run inside the PVC conduit.
Supply and Fix in replacement of Projection Lamp for operation surgical light Type 7027 Cat Part No BRL/BCD AI/220 of 12 V, 50 Wand 50Hz frequence
M&L for Point wiring with FRLS PVC insulated and unsheathed electric cable 1100 volts grade single core having multistranded copper conductor of 2.5 Sqmm nominal cross sectional area for phase & neutral, drawn in and including non metallic rigid PVC conduit in concelead in walls not less than 25mm base size with all fitting and fixing accessories and with 2.5 Sqmm green FRLS PVC insulated unsheathed multistranded copper conductor cable as continuous earth conductor connected to earth dolly by providing suitable lugs excluding galvanised boxes of suitable size with white laminated bakelite sheet for mounting switches,sockets etc complete for 15 amps socket point on independent board controlled by one switch.
S&F MCB SPN, 32 AMP rating 240 V, 10 KA breking capacity "C " curve in the MCB DB complete with connection testing and commissioning all as specified & directed.
REPAIR/MAINTENANCE OF AC,WATER COOLER,OXYGEN PIPE LINE :
Supply and lay in repair/replacement of 22mm outer dia , 0.9mm thickness copper pipe with elbows,flanges,specials ,steel support , other fittings etc as required at site for medical gases complete all as specified and directed by Engineer in charge. NOTE: The copper pipe shall be solid drawn seamless deoxidised, un-arsenical, half hard, tempered and of degreased material conforming to BS-EN 1057/13348 of copper pipe with colour coded.
Supply and lay in repair/replacement of 15mm outer dia , 0.9mm thickness copper pipe with elbows,flanges,specials ,steel support , other fittings etc as required at site for medical gases complete all as specified and directed by Engineer in charge. NOTE: The copper pipe shall be solid drawn seamless deoxidised, un-arsenical, half hard, tempered and of degreased material conforming to BS-EN 1057/13348 of copper pipe with colour coded.
Supply and lay in repair/replacement of 12mm outer dia , 0.9mm thickness copper pipe with elbows,flanges,specials ,steel support , other fittings etc as required at site for medical gases complete all as specified and directed by Engineer in charge. NOTE: The copper pipe shall be solid drawn seamless deoxidised, un-arsenical, half hard, tempered and of degreased material conforming to BS-EN 1057/13348 of copper pipe with colour coded.
Supply and fix in repair/replacement of oxygen outlet/oxygen shutter type specific for the services indicated to accept only compatible quick connect Geometric Index type steel adapters as HTM/NFPA standard as required all as specified and directed by Engineer in charge.
Supply and fix in repair/replacement of oxygen flow meter with mask made from brass, chrome plated ,back pressure compensated type having housing of Polycarbonate auto clavable reusable flow range 0-15 LPM fitted with suitable matching adopter for oxygen outlet point and humidifier compatible with Flowmeter and reusable and as per specifications and as required with suitable steel adopter etc complete all as specified and directed by Engineer in charge.
Supply and fix in repair/replacement of Isolation valves 22mm are to be ball valves, with stainless steel balls and PTFE or Teflon seals. They shall be suitable for a working pressure of 10.2 Kg/cm² gauge. Valves shall be fitted into the pipeline by means of capillary hard soldered joints containing silver. it should be open/close with help of handle with rotation of 90 degree etc complete all as specified and directed by Engineer in charge.
Supply and fix in repair/replacement of isolation valve 15mm , ball valves with stainless steel balls and PTFE or Teflon seals , suitable for a working pressure of 10.2 Kg/cm² gauge ,fitted into the pipeline by means of capillary hard soldered joints containing silver , open/close with help of handle with rotation of 90 degree etc complete all as specified and directed by Engineer in charge.
M&L as required for repairing existing unserviceable oxygen points and making into functional of servicing the exiting oxygen gas discharge points of area line alarm complete all specified and directed by Engineer in charge.
Supply and fix in repair/replacement of vacuum outlet gas specific for the services indicated to accept only compatible quick connect Geometric index type complete all specified and directed by Engineer in charge.
Supply and fix in repair/replacement of vacuum Jar with rubber tubings complete with regulator capable of controlling vaccum between 0 to 760 mm Hg and Polycarbonate autoclavable reusable type receiver jar of not less 600 ml ,vacuum regulator with dial gauge, on/off switch, valve control knob and as per specifications and as required. with suitable steel adopter etc complete all as specified and directed by Engineer in charge.
Supply and lay in repair/replacement of 16mm outer dia , 0.9mm thickness copper pipe with elbows,flanges,specials ,steel support , other fittings etc as required at site for medical gases complete all as specified and directed by Engineer in charge. NOTE: The copper pipe shall be solid drawn seamless deoxidised, un-arsenical, half hard, tempered and of degreased material conforming to BS-EN 1057/13348 of copper pipe with colour coded.
Supply , installing, commissioning and testing in repair of Oxygen Manifold Main confirming to ISO standards with Middle Frames 2 Banks x 4 Cylinder per Each bank Oxygen Manifold (without cylinders) , suitable to withstand a pressure of 145 Kg/cm2, along with high-pressure copper annealed tail pipes with end Brass adapter suitable for oxygen cylinders and manifold ,top frame comprising of high pressure copper pipes of size 1/2” I.D. x 15 swg with high pressure brass fittings made of high tensile brass and connections through non- return valves , high pressure copper tail pipes, made of high pressure copper pipe of size 1/4” I.D. x 15 swg .The design of middle and bottom frames shall be provided to fit both round and flat bottom cylinders safely. The manifold shall be tested (hydraulically) at 3500 psig and necessary test certificates accompany along with the supply. Non Halogenated Polymer materials only shall be used in the Non Return Valves supplied along with the manifold complete all as specified and directed by Engineer-in-Charge. Make: Oxicareengineers/ Globalmedlife Solution/ Lifeline Medisol/ Aktiv/LMPL
Repair,servicing,testing, work carried out for cold storage CHILLER ROOM 1 as per under mentioned specifications including testing and commissioning all as per directed by Engr-in-Charge :- (a) Dimensions : 170''Lx162''Wx108''H (in inches) (b) Ambient Tempature : 43 degree centrigrade (c) Room Tempature : 2 degree centrigrade to 12 degree centrigrade (d) Product to be stored : Dry fruits/Dairy products (e) Cooling time : 24 Hrs (f) Product incoming temp : (+) 25 degree centrigrade (g) Door opening per hrs : 1-2 times/ Hr (h) Insulation : Pre feb modular PUF panels- Ecofriendly panel (j) Thickness of insulation : 60 mm thick, density 40+/- 2 Kg/cubic meter (k) Lamination of panels (wall & celling) : Internal & External Exposed : PP/PP (l) Door Details : Swing door with PP inside and outside, 60 mm thick 34''x78'' clear opening single leaf door (m) Refrigeration systems : Refrigerent R22, split type, Aircooled (n) Refrigeration capacity: 20000BTUx1 No, total 20000 BTU/Hr (o) Refrigeration unit : Blue star make with matching condensing unit (p) Compressor type : Hermetic recip compressor (q) power supply requirement : 415 V/3Ph/50 Hz (r) Digital temperature controller: provided (s) power consumption : 3.2 Kw/Hr
Repair,servicing,testing, work carried out for cold storage CHILLER ROOM 2 as per under mentioned specifications including testing and commissioning all as per directed by Engr-in-Charge . (a) Dimensions : 72.5''Lx162''Wx108''H (in inches) (b) Ambient Tempature : 43 degree centrigrade (c) Room Tempature : 2 degree centrigrade to 12 degree centrigrade (d) Product to be stored : Dry fruits/Dairy products (e) Cooling time : 24 Hrs (f) Product incoming temp : (+) 25 degree centrigrade (g) Door opening per hrs : 1-2 times/ Hr (h) Insulation : Pre feb modular PUF panels- Ecofriendly panel (j) Thickness of insulation : 60 mm thick, density 40+/- 2 Kg/cubic meter (k) Lamination of panels (wall & celling) : Internal & External Exposed : PP/PP (l) Door Details : Swing door with PP inside and outside, 60 mm thick 34''x78'' clear opening single leaf door (m) Refrigeration systems : refrigerent R22, split type, Aircooled (n) Refrigeration capacity: 10,000BTUx1 No, total 10,000 BTU/Hr (o) Refrigeration unit : Blue star make with matching condensing unit (p) Compressor type : Hermetic recip compressor (q) power supply requirement : 230 V/1Ph/50 Hz (r) Digital temperature controller: provided (s) power consumption : 1.8 Kw/Hr
M&L for transporting Air Conditioner of any type after checking at site to workshop at E/M yard, taking out compressor from Air conditioner of window / Split type, 1.5 / 2.0 ton capacity by opening including cutting & brazing of suction / discharge tubing, complete all as specified and directed.
S&F Sealed compressor unit of capacity 1.5 Ton for window type air conditioner / split type AC, complete all as specified and directed. MAKE:- ACCEL/ CARRIER / KIRLOSKAR COPLAND / VOLTAS or other equivalent as approved by GE.
S&F Sealed compressor unit of capacity 2.0 Ton for window type air conditioner / split type AC, complete all as specified and directed. MAKE:- ACCEL/ CARRIER / KIRLOSKAR COPLAND / VOLTAS or other equivalent as approved by GE.
Supply and fill gas charging in Air conditioner window / Split AC 1.5 / 2 Ton Capacity with suitable refrigerant Gas not eceeding 1.0kg after fixing new compressor including replacement of filter strainer and testing on completion all as specified and directed.
M&L for detecting the cause of leakage , rectifying the same as per existing material , ensure the complete AC system leak proof and finally gas charging with suitable refrigerant gas not exceeding 1.0 kg for window type AC / split type AC including testing for smooth functioning, complete all as specified and directed.
Repair / Servicing window type / split type AC 1.5 ton / 2 ton capacity of any make by opening the unit ,checking blower motor, condenser fan motor, fan blade, blower drum any type, cleaning and servicing of serviceable parts, replacement of wiring kit, knob and unserviceable spare parts , replacement of insulation foam 3 mm thick, air filter and re- assembling the serviceable parts ,checking / lubricating of all parts, tighening electrical connection etc and testing for smooth functioning and make complete unit in perfect condition to the entire satisfaction of Engineer-in-charge NOTE:- (a) Spare parts as required shall be measured and paid seperatly as 'Supply and fix' under respective items of this Schedule.
S&F the following spares/ items for window type / split type AC unit of any capacity including dismantling the old unserviceable items complete all as specified and directed.
Running capacitor 36 / 45 / 50 + 6mF ± 5%, 440 Volt AC. MAKE:- Usha / Asian / Crompton greaves / Sriram / Havells / Epicos / Totaline or other equivalent as approved by GE.
Relay for window AC of capacity 1.5 Ton / 2 Ton
Thermostate for AC
Blower motor, single phase, 230Volt AC for window type air condtioner. MAKE:- KIRLOSKAR / JYOTI / BEACON or other equivalent as approved by GE.
Blower fan blade made of plastic for window or split air conditioner.
Condensor fan blade made of plastic for window or split air conditioner.
Indoor unit complete for 1.5 ton split type air conditioner.
Condensor motor 0.1 HP (1/10) , single phase, 230 V, AC electric supply for outdoor unit of split type air conditioner any capacity
Condensor motor 0.05 HP (1/20) single phase, 230 V, AC electric supply for outdoor unit of split type air conditioner any capacity
Programmable Logic Controller (PLC) unit for split type air conditioner, same make and capacity as existing MAKE:- CARRIER / VOLTAS / ACCEL / LG / SAMSUNG / BLUE STAR or other equivalent as approved by GE.
Contactor, single phase, 230V of suitable capacity for Split type AC of 1.5 Ton / 2 Ton capacity including coil. MAKE:- CARRIER / VOLTAS / ACCEL or other equivalent as approved by GE.
S&F sub main wiring complete with 2 runs of 6 sq.mm PVC insulated and unsheathed 1100V grade multistranded FRLS grade copper conductor cable drawn through and including provision of rigid PVC conduit 25mm dia including conduit accessories and connecting terminal ends to DB's including providing 1 run of 6 sq.mm PVC insulated unsheathed multistranded FRLS grade copper cable as earth continuity conductor and connecting to common earth dolly, complete all as specified and directed. NOTE:- (i) Two runs of 6 sq.mm copper conductor, one run of 6 sq.mm copper earth continuity conductor and one run of PVC conduit and conduit accessories shall be measured as one unit length. (ii) Extra length of cable / wire required for connection to MCBs shall not be measured and the rate quoted per unit shall deemed to be inclusive of the same accordingly.
S&F sheet metal enclosure with three pin earth plug and socket complete with MCB 20 Amp, Single Pole 240 Volt 'C' curve and 10kA breaking capacity including taking down existing unserviceable sheet metal enclosure, complete all as specified and directed.
M&L for transporting water cooler of any type and capacity after checking at site to workshop at E/M yard, taking out compressor from water cooler by opening including cutting & brazing of suction / discharge tubing, complete all as specified and directed.
S&F sealed compressor unit of water cooler 60 / 120 litre cooling capacity and make suitable for existing water cooler, complete all as specified and directed. MAKE:- Copeland, Usha , Tecum sheh, Voltas, Blue Star, Accel, Hitachi, LG.
S&F sealed compressor unit of water cooler 40 / 80 litre cooling capacity and make suitable for existing water cooler, complete all as specified and directed. MAKE:- Copeland, Usha , Tecum sheh, Voltas, Blue Star, Accel, Hitachi, LG.
Supply and fill gas charging in water cooler of any capacity with suitable refrigerant Gas not eceeding 1.0kg after fixing new compressor including replacement of filter strainer and testing on completion all as specified and directed.
M&L for detecting the cause of leakage , rectifying the same as per existing material , ensure the complete water cooler system leak proof and finally gas charging with suitable refrigerant gas not exceeding 1.0 kg for water cooler including testing for smooth functioning, complete all as specified and directed.
Labour only for disconnecting of existing electric connection and water connection of water cooler, opening the condensor fan motor blade, electrical accessories and other spare parts of system carefully and replace defective spare parts as required , oiling of fan motor etc., reassembling all spare parts including rewiring of internal connection of water cooler, re-connecting electric and water connection, testing and commissioning, complete all as specified and directed. NOTE:- (i) Spare parts shall be measured and paid separately as 'Supply and fix' under respective items of this Schedule. (ii) Nut, bolts, washers etc as required for smooth functioning shall be provided and deemed to be included in unit rate quoted. (iii) Minor repair such as chassis by brazing / welding work shall be done and deemed to be included in unit rate quoted.
Supply and fix following spare parts for water coolers of any capacity, complete all as specified and directed :-
Running capacitor 25 / 36 mF ± 5%, 440 Volt AC supply. MAKE:- Usha / Asian / Crompton Greaves / Sriram / Havells / Epicos/ Totaline other equivalent as approved by GE.
Running capacitor 20 / 10 mF ± 5%, 440 Volt AC supply. MAKE:- Usha / Asian / Crompton Greaves / Sriram / Havells / Epicos / Totaline other equivalent as approved by GE.
Starting capacitor 60 / 70 mF. MAKE:- Usha / Asian / Crompton Greaves / Sriram / Havells / Epicos / Totaline other equivalent as approved by GE.
Starting capacitor 40 / 50 mF. MAKE:- Usha / Asian / Crompton Greaves / Sriram / Havells / Epicos / Totaline other equivalent as approved by GE.
Starting capacitor 80 mF. MAKE:- Usha / Asian / Crompton Greaves / Sriram / Havells / Epicos / Totaline other equivalent as approved by GE.
Start Relay for water cooler, any capacity.
Over load protector, make and capacity shall be same as that of existing
Thermostat of capacity as exisitng at site.
Condensor motor 0.02857 (1/35) hp, single phase, 230V.
Condensor motor 0.04167 (1/24) hp, single phase, 230V.
Condensing coil
Plastic drain hose pipe, of length not exceeding 1.5 metre.
Push cock / lift cock, brass, chromium plated.
Capillary Tube, of length not exceeding 0.60 metre.
Float Valve 12.70 mm (1/2") including assembly brass made
M&L for detection and rectification of leakage of storage tank of water cooler by brazing, soldering / welding as required at site or at work shop and repalcement of unserveciable spare parts such as Nipple adaptor, Push cock, Float valve and Bush, nut, bolt, washer, rubber / plasting packing for smooth functioning and testing for leak proof, complete all as specified and directed. NOTE:- The unit rate quoted shall deemed to be include the cost of spares as mentioned above and no extra claim what-so-ever shall be admissible at a later stage.
M&L for preparation of old surfaces of water cooler and applying one coat of synthetic enamel paint of approved tint using spray machine, complete all as specified and directed.
supply and replacement of drain tray with PVC pipe for water cooler, electroplating (chromium plating) of drain tray after repair by denting including refixing back in original position, complete all as specified and directed.
Vinayak Trading House
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .