| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹2.9 LAccepted-AOC VILL PO BUNGWAN KALAN TALBEHAT LALITPUR UTTAR PRADESH 284136 | TALBEHAT | LALITPUR | UTTAR PRADESH | 284136 | 1 | Accepted-AOC LOWEST BIDDER | |
| 2 | 2₹3.0 L+₹4,332 (1.47%)Rejected-Finance | 2 | Rejected-Finance NOT LOWEST BIDDER | |
| 3 | 3₹3.1 L+₹11,361 (3.85%)Rejected-Finance CIVIL LINE MATATILA ROAD TALBEHAT DISTT LALITPUR U P | TALBEHAT | LALITPUR | U P | 3 | Rejected-Finance NOT LOWEST BIDDER |
Tender Value
₹4.0 L
EMD Value
₹8,020
Closing Date
27 Dec 2023, 6:00 pmClosed
AJAY KUMAR SINGH
LAKE VIEW CAMP MILITARY STATION TALBEHAT, PIN-284125
PROVN OF SENTRY ROOM AND PARKING SHED IN ZONE-10 AT TALBEHAT MIL STN
2023_MES_629268_1
AGE(I)/TBT/TOK-69/2023-24
Open Tender
Civil Works
Item Rate
180 days
TALBEHAT MIL STN
7 documents required · 7 mandatory
₹500
AGE I TALBEHAT
₹8,020
14 Feb 2024
22 Nov 2023
29 Dec 2023
29 Nov 2023
27 Dec 2023
6 Dec 2023
Amount
M&L for Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soft/loose soil.
M&L for PCC 1:4:8, type D-2 using 40mm graded stone aggregate as in foundations, fillings, mass concreting complete all as specified and directed.
M&L for RCC nominal mix 1:1.5:3 type A-1(using 20mm graded stone aggregate) for Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
M&L for RCC nominal mix 1:1.5:3 type (using 20mm graded stone aggregate) A-1 for Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M&L for RCC nominal mix 1:1.5:3 type A-1(using 20mm graded stone aggregate) for Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
M&L for RCC nominal mix 1:1.5:3 type A-1(using 20mm graded stone aggregate) for Columns, pillars, piers, posts and struts complete all as specified and directed.
M&L for RCC nominal mix 1:1.5:3 type A-1(using 20mm graded stone aggregate) for Chajjas complete all as specified and directed.
M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed.
M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed.
M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc.complete all as specified and directed.
M&L for Formwork to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and directed.
M&L for Formwork to chullah hoods, chajjas, troughs and similar items including edges
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm.complete all as specified and directed.
Removing excavated material exc. 250 m but n exc. 500 m and depositing where directed
M&L Brickwork with fly ash Old size bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6, complete all as specified and directed
M&L PCC (1:4:8) type D-2 (using 20mm graded stone aggregate) 75mm thick as in sub base of floors all as specified and directed.
M&L PCC (1:2:4) type B-0 (using 12.5mm graded stone aggregate) 25mm thick as in floors all as specified and directed.
M&L PCC (1:3:6) type C-2 using 20mm graded stone aggregate 75mm thick as in plinth protection finished surface even and smooth with using extra cement laid in alternate bays n.exc 2m in length all as specified and directed.
M&L for Hardcore Broken stone or boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed.
S&F for 165mmx60mm Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified and as directed.
S&F M.S work as in holdfasts., wind ties , plane angle cleats for securing purlins to wooden trusses or rafters etc. complete all as specified and as directed
M & L cement concrete type B-0 1:2:4 (12.5 mm graded agg ) as in bed block , coping & filling to PS Frame etc complete all as specified and as directed
S&F Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for Chain link fencing confirming to Fe 410-w (Gde E-250) complete all as specified and directed.
S&F Mild steel TMT bars but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders cut to length, bent to shape required, including cranking, bending spirally for hooping confirming to Fe 410-w (Gde E-250) complete all as specified and directed.
S&F powder coated anodized aluminium frames for door, window , ventilators with one or more rebates including joining cleats for fixing etc complete all as specified and as directed by Engr-in-charge
S&F powder coated aluminium anodized side hung type window/ventilators shutter without sash bars section weight not less than 0.55Kg/RM with extruded built up standard tubular and other sections of approved make according to IS(thickness of powder coating not less than 50micron including necessay glazing clips weight not less than 0.124Kg/Rm for fixing sheet glass anodized aluminium fittings/fixtures such as required number of roller of suitable size interlocking cleats/ plates etc as required for complete fixing window shutters complete all as specified and as directed by Engr-in-charge. Note:- Only aluminium shutters for the window shall be measured in sqm sheet glass and wiremesh etc shall be measured and paid in respective items
Supply and fixing 4.8mm thick sheet glass tinted of ordinary quality in squares n. exc 0.5 sq.m each pane complete all as specified and as directed.
S&F II nd class HW, 35 mm thick plain framed panelled shutter (two panel) with lock rail and panel of 9 mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (part I) kiln seasoned and chemically pressure treated complete all as specified and as directed
S&F 35mm thick IInd class hard wood glazed skelton shutters open rebated and prepaired to recive glass,guage etc, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc size of members of sutters as specified in SSR part - I section - 8, clause 8.20 (a). S&F to chowkhat complete all as specified and as directed
M&L for MS framed work such as framed guard bars / railings design/pattern aaproved by Engr-in-Charge conforming to Fe 290-0 or Fe 330-0 welded to ventilator/window complete all as specified and directed
S & F Stailess steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed on wooden/steel frames with tinned tacks or galvanized wire staple & complete all as specified and directed.
S&F 150mm size aluminium alloy handles, febricated type extruded section, ISI marked complete all as specified and as directed
S&F for aluminium anodized barrel tower bolts 200 mm of extruded section and fixed complete all as specified and as directed
S & F 300mm long aluminium alloy, anodised, sliding door bolts with hasps, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and directed.
S&F Stainless steel 20mm dia curtain rod including fixing brackets and stainless steel knobs complete all as specified and directed.
M&L rendering 5 mm thick in cement plaster on ceiling in cement mortar 1:3 on concrete surface finished even and smooth without using extra cement complete all as specified and as directed
M&L rendering 10mm thick in cement plaster 1:6 on walls surfaces of brick work/ concrete and surface finished even and smooth without using extra cement complete all as specified and as directed
M&L rendering 15mm thick in cement plaster 1:4 on walls surfaces of brick work/ concrete and surface finished even and smooth without using extra cement complete all as specified and as directed
M&L for preparation of new plastered surfaces of walls and applying two coats of oil bound distemper all as over a coat of primer complete all as specified and directed
M&L for preparation of new plastered surfaces of walls and applying two coats of Cement base paint all as over a coat of primer complete all as specified and directed
Material and labour for preparation of newly plastered surfaces and applying three coats of white wash on ceilings.
M &L for coloured non skid ceramic tiles 7 to 8 mm thick (square /rectangular) area of each tile exceeding 0.11 sqm but n.exc 0.18 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over 15mm thick screed in CM (1:4) complete all as spd and as directed..
All as the item above but as in skirting but over 10mm thick CM (1:4) plaster complete all as specified.
M & L for preparation of new wooden surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer all as specified
M & L for preparation of new steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide zinc crome primer all as specified
M&L rendering 10mm thick in cement plaster 1:4 on surfaces of brick work/ concrete and surface finished even and smooth without using extra cement on roof slab apply when the surface is green complete all as specified and as directed
Surface excavation in loose soil n. exc (not exceeding) 30 cm deep and averaging 15 cm deep and getting out
Excavating in post holes (or similar holes) each n. exc 0.5 cu m, getting out,in soft/loose soil, returning filling in and ramming earth or broken mixed with earth around in layers not exceeding 25 cm
M&L PCC (1:4:8) type D-2 (using 20mm graded stone aggregate)100 mm thick as in sub base of floors all as specified and directed.
S&F rolled mild steel section work as in main and cross beam, hip and jack rafters purlins where connected to common rafters and running rails and guides for sliding door fixed with angle cleats or other connecting plates and cooler stand and similar work confirming to Fe 410W(Gde E-250 quality A) complete all as specified
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5 mm thick,Trapezoidal roofing profile with 190 mm Pitch & 29 mm depth of profile of any colour having tensile strength of 550 Mpa fixed with self tapping screws as specified & directed.(For sun shed)
M&L Painting to new steel and iron surface of any description over 10cm in width or girth not otherwise described with two coats of synthetic enamel paint over coat of red oxide primer complete all as specified and directed
M&L for providing plain cement concrete 1:3:6 type C1 using 20mm graded stone aggregate as kerb or benching to wall and similar work complete all as specified and as directed by Engr-in-Charge
Machine pressed precast concrete interlocking paver block with grey cement pigment any shape and size confirming to IS 15658-2006 of 80 mm thickness,M- 40 Grade of approved quality,laid over and include 50mm thick sand cushion vibtrated with mecanical vibrator complete all as specified and as directed.
Supply and laying or fixing or passing through pipe in replacement, 1100 volts grade heavy duty cable with PVC insulated aluminium stranded conductor served with an inner sheathing of PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more than 1.00 meter apart including 4mm dia suspension wire one twin core cable flat or circular of size 10 sqmm 2 core complete all as specified and directed by Engineer in charge.
S&F house service bracket hook type complete with 3.00 Mtr Long GI Pipe 40mm dia medium grade, 02 Numbers 90 degree bends MS hook and stay or guy.
Material and Labour for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground( earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in electrical plate No 3 of SSR Pt I including necessary excavation and earth work PCC (1:3:6) type C-1 with 50 mm thick pre cast RCC ( 1:2:4) type B-1 cover slab framed with 50X30X4 mm MS angle (reinforced with 6 mm dia deformed bar @ 15 cm C/C both ways and suitable handle of 10 mm dia round bar) including providing charcoal or coke and magnesium sulphate in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (medium grade) wire mesh, copper lugs, complete in all respect., GI earth wire protected by 40 mm bore (light grade) galvanized iron pipe and other end connected to the earth bar (test point) made of MS flat (400X32X6 mm) bend in ‘D’ shape and fixed to wall by means of fast nut or bolt grouted in to wall at 1 mtr from plinth height. 4sqmm PVC insulated (colour green) copper conductor single run as earth continuity conductor along with 15 mm PVC conduit grouted in wall or fixed on wall surface to be continued up to main switch board and fix with common earth dolly as directed by EIC . Disposal of soil to a distance not exceeding 50 mtr and necessary testing on completion complete all as specified and as directed.
M/L for point wiring concealed type with 1.5sq mm FRLS PVC insulated unsheathed single core multithreaded copper conductor cable 1100 volts grade incl 1.5 Sq mm PVC insulated unsheathed copper conductor cable as earth continuity conductor drown through in and incl FRLS PVC rigid conduit not less than 20 mm dia with its accessories pressed steel terminal box incl 3mm thick ISI marked laminated sheet cover for fixing switches/socket/regulators etc for the following: Note:- On RCC ceiling/column, false ceiling, AC/Metallic Sheet ceiling wiring done on surface with conduit/PVC Casing caping and its accessories.
One light/fan point controlled by one No piano type switch 5 Amps single pole one way
One socket outlet 5/3 pin 6 AMPS controlled by one switch on the same board.
One socket outlet 5/3 pin 6 AMPS controlled by one switch on independent board.
All as per item No 3 above but 3 pin socket out let 15/16 Amps on the independent Board all as spfd with single core unsheathed PVC insulated cable multistranded copper conductor of size 2.5 sq mm for phase & neutral & 2.5 sq mm for earth continuity conductor.
S&F Switch Piano Flush button single pole one way 5/6 Amp.
S&F Switch Piano Flush button single pole one way 15/16 Amp.
S&F socket outlet 2 in 1, 3 pin & 2 pin, 5/6 Amp, 240 volt.
S&F socket outlet 2 in 1 , 3 pin & 2 pin, 5/6 Amp and 15/16 Amp, 240 volt.
S&F ceiling rose surface bakelite 65mmx50mm 100watt three terminal.
S&F step type electronic fan regulator flush type on the existing phenolic laminated sheet.
S&F Lamp hoder/Batten holder PVC/Polycarbonate insulated body with metal ring and back plate for batten fitting.
S&F sheet metal enclosure double door for MCB DB single pole and neutral 8 way with 200 Amps rated bus bar 240 volts double door (Metallic) type.
S&F MCB SP 5 to 32 Amps 240 volts 'C' series, 10 KA, 50 Hz including connection in the DB and testing/commissioning. Make:- As approved Make of DB
S&F MCB SPN 32/40 Amps 240 volts 'C' series, 10 KA, 50 Hz. Make:- As approved Make of DB
Supply and fixing LED lights fitting 1x 18W, 4 feet, 220V,AC decorative box type with driver, holder including LED light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
S&F LED Lamp 9W B22 Type all as specified and directed.
Supply and fixing ceiling fans complete with blades, down rods and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor(BLDC)
supply & Installation of desert cooler electric driven (single phase) having nominal air flow capacity 6000 cum/ hour (or nearest size) incl PVC water pipe connection with brass coupling nuts at both ends and PVC float valve including plug top complete all as specified and directed.
Note :- Debris obtained from all items should be removed in low lying areas as directed by Engr-in-charge out of MOD Land. (Rates quoted for items are deemed to be included for this, where removal of debris in the items is not considered.)
M/s Indu Enterprises
HARNAM SINGH ANIL SINGH
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .