Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹33.0 LAccepted-AOC WZ 1000 B NANGAL RAYA PANKHA ROAD NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | 1 | Accepted-AOC AWARDS | |
| 2 | 2₹33.5 L+₹55,384.60 (1.68%)Rejected-Finance SHOP NO 33 GOPI NATH BAZAR DELHI CANTT 10 | DELHI CANTT | NEW DELHI | DELHI | 110010 | 2 | Rejected-Finance Rejected being not L1 | |
| 3 | 3₹34.3 L+₹1.3 L (4.07%)Rejected-Finance RZ 212F D BLOCK RAJ NAGAR PART II PALAM COLONY NEW DELHI 110077 | SOUTH WEST | DELHI | 110077 | 3 | Rejected-Finance Rejected being not L1 | |
| 4 | 4₹36.1 L+₹3.1 L (9.52%)Rejected-Finance | 4 | Rejected-Finance Rejected being not L1 | |
| 5 | 5₹36.6 L+₹3.6 L (10.9%)Rejected-Finance NO 9 BYRAVESHWARA INDUSTRIAL ESTATE ANDRAHALLI MAIN ROAD NEAR PEENYA 2ND STAGE BENGALURU 560 091 | BENGALURU URBAN | KARNATAKA | 560091 | 5 | Rejected-Finance Rejected being not L1 |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
25 Sept 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE UTILITY ELEC SUPPLY
GE UTILITY ELEC SUPPLY DELHI CANTT
PROVISION OF EXTERNAL ELECTRIC SUPPLY 11 KV FOR THE PROJECT CONSTRUCTION OF TRANSIT FACILITY FOR OFFICERS AT PALAM UNDER GE U ELECT SUPPLY DELHI CANTT 10
2024_MES_671347_1
GE ELECT/D-47/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE UTILITY ELEC SUPPLY
AS PER TENDER DOCUMENT
7 documents required · 7 mandatory
₹500
GE UTILITY ELEC SUPPLY
₹94,000
Yes
13 Nov 2024
4 Sept 2024
26 Sept 2024
4 Sept 2024
25 Sept 2024
18 Sept 2024
Amount
Excavation in trenches in soft and loose soil n.exc 1.5 mtr wide and n.exc. 1.5 mtr depth for laying and taking out of electric power cable and getting out all as specified and directed by Engineer –in-charge.
Material & Labour for returing filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and directed by Engr-in-Charge.
Material & Labour for for removing of excavated material n exc. 50m and depostiting where directed at a level n exc. 1.5m in soils complete all as specified and directed by Engr-in-Charge.
Material & Labour for sand as in sand cushioning to underground XLPE cable incl punning down of sand layer complete all as specified and directed by Engr-in-Charge.
Supply and laying unreinforced precast concrete cable covers class HV Type -1 with flat size 300 x 180 x 40 mm complete all as specified and directed by Engr-in-Charge.
Material & Labour for boring of holes under road/pavement/hard standing by trenchless technology using ultra sound technique and necessary machine including material and labour for HDPE pipe of 160 mm dia suitable for 06 Kg/cm working pressure. Wall thickness of pipe not less than 6.5 mm complete all as specified and directed by Engr-in-Charge. Note :-The contractor will be responsible for taking permission from appropriate authority i.e. NHAI / IGL or other Units , if needed, for above said work.
Supply and laying cable XLPE insulated screened PVC bedded,galvinised steel strip or wire armoured, electric power cables (heavy duty) 11000 Volt grade with stranded aluminium conductor of size 240 Sqmm 3 core complete all as specified and directed by Engr-in-Charge.
Supply and laying cable XLPE insulated screened PVC bedded,galvinised steel strip or wire armoured, electric power cables (heavy duty) 11000 Volt grade with stranded aluminium conductor of size 120 Sqmm 3 core complete all as specified and directed by Engr-in-Charge.
Supply and laying cable end jointing kit for 11 KV grade cable for outdoor terminal heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 240 sqmm complete all as specified and directed by Engr-in-Charge.
Supply and fixing cable end jointing kit for 11 KV grade cable for outdoor terminal heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 120 sqmm complete all as specified and directed by Engr-in-Charge.
Supply, jointing and testing, straight through joint, heat shrinkable type, suitable for HT, 11 KV (E) XLPE cables, aluminium stranded conductors cable 3 core, 240 Sqmm complete all as specified and directed by Engr-in-Charge.
Supply and installation , testing and commissioning of 11 KV, 630 Amps, 21 KA/3 sec outdoor type Ring main unit IP 54 protection plug in type extensible on one side SF 6 gas insulated two incoming and one outgoing (3 way ) with metering plate form mounted compact switch gear consisting of 02 Nos load break switch as incommer and 01 Nos outgoing VCBs , all live parts, bus bars VCB will be enclosed in robotically/manual welded minimum 2 mm thick stainless steel tank filled with SF 6 gas IP 67 Degree of protection and tested for internal arc 20 KA/1 sec as per latest IEC 62271-200 complete installed on plateform as recommended by OEM, including the cost of PCC foundation for placing of RMU on plinth complete all as specified and as directed. The unit shall include the following with all necessary standard fitting required at site : - (A) Incoming Load Break Module - 02 Nos each switching unit shall be designed as a three position switch. This three function switch combines the functions of switch disconnector and earthing switch cables switch 12 KV, 630 Amp, 21 KA - 01 Set. Snap action mechanism for motorised and manual(Both) operation with integrated earthing switch - 01 Nos. Cable bushing 630 Amp standard C bushing - 01. Fault passage indicator, On(N-1) load break switch where n= no of load break switch >>s/c & E/F FPI with digital display to be added for detection of cable fault. ON, OFF, EARTH mechanical indication on the front mimic of the panel - 01. Capacitive voltage indication fixed type LED display - 01. ON, OFF, TRIP mechanical indication on the front mimic of the panel - 01. Cable box for termination of cable up to 1 No. x 185 sq.mm - 01. Cable cover standard - 01. Set of 12kV Cable Termination Boots - 01. Cable entry bottom, front - 01
(B) (i) Out going VCB - 01 No consisting of following - function unit consist of vaccum circuit breaker in combination with a three position switch. The three position switch fulfills the operation of the disconnector function and earthing function circuits breaker unit is equipped with an over current transformer for the protection of distribution Transformer/circuit vaccum circuit breaker 12 KV, not less than 400 A, 21 KA - 01. Spring assisted closing with stored Energy triping mechanism for motorised operation with integrated earthing switch - 01. live cable LED indicators through capacitor voltage dividers mounted on the bushings push button for breaker trip - 01 sec O/C + E/F self powered numerical protection relay with low and High set for Over current and earth fault Relay should have facility to display the maximum loaded phase current also current also relay shall record minimum 5 fault records with time stamping - 01 Alram trip indication 6 window anuciator for transformer faults Mechanical ON/OFF/EARTH indication -01. Auxliary contacts on load switch are 1 No+2NC & Auxiliary conract on earth switch is 1 No+ 1NC-01. Self powered electronic numerical protection relay providing 3 over-currents & 1 E/F protection - 01, shunt trip coil 24 V DC-01 capactive voltage indication fixed type LED display -01 ON/OFF/Trip mechanical indication on the front mimic of panel-01 cable box for termination boots-01. Metering Equipment incl. 01 x Digital Voltmeter (Acc.Cl.0.5), 01 x Digital Ammeter (Acc.Cl.0.5), 01 x Tri-VectorMeter (Acc.Cl.0.5) for measuring of PF,KVAR,KVA, KWH ,frequency, voltage with accuracy 1.0 for avtive energy, Auxliary relay for transformer protection -06. The relay having faciliate to Transformer protection and connected with buchhol relay of Transformer complete all as specified and directed. (B) (ii) Out going VCBs - 01 No, One consisting of CT 100/1 -5p10.2.5VA- 03. (C ) Additional equipment deliverd separately or mounted seperatly, Bus connected with battery charger and inbuilt battries for motor power supply-01 (i) PT ratio 11KV/3/110/v3, 100 va, 0.5 class for measurement with volts meter(ii) Auxliary transformer of 11KV/230V, 1 KVA for powering the motors and battery charger (iii ) 24 V DC battery charger and battries for motor power supply. Standard mano meter -01, Operating handle - 02 , cable clamping provision(standard)-01 Operation and maintance manual - o1, installation and commissioning manual - 01, cost of PCC works for placing RMU on plinth is deemed to be included in the cost, Height of plinth shouldnot be less than 0.45 mtrs from ground level.
Supply and installation , testing and commissioning of 11 KV, 630 Amps, 21 KA/3 sec outdoor type Ring main unit IP 54 protection plug in type extensible on one side SF 6 gas insulated two incoming and two outgoing (4 way ) with metering plate form mounted compact switch gear consisting of 02 Nos load break switch as incommer and 02 Nos outgoing VCBs , all live parts, bus bars VCB will be enclosed in robotically/manual welded minimum 2 mm thick stainless steel tank filled with SF 6 gas IP 67 Degree of protection and tested for internal arc 20 KA/1 sec as per latest IEC 62271-200 complete installed on plateform as recommended by OEM, including the cost of PCC foundation for placing of RMU on plinth complete all as specified and as directed. The unit shall include the following with all necessary standard fitting required at site : - Including the cost of PCC foundation for placing of RMU on plinth complete all as specified and as directed (A) Incoming Load Break Module - 02 Nos each switching unit shall be designed as a three position switch. This three function switch combines the functions of switch disconnector and earthing switch cables switch 12 KV, 630 Amp, 21 KA - 01 Set. Snap action mechanism for motorised and manual(Both) operation with integrated earthing switch - 01 Nos. Cable bushing 630 Amp standard C bushing - 02 Fault passage indicator, On(N-1) load break switch where n= no of load break switch >>s/c & E/F FPI with digital display to be added for detection of cable fault. ON, OFF, EARTH mechanical indication on the front mimic of the panel - 01. Capacitive voltage indication fixed type LED display - 01. ON, OFF, TRIP mechanical indication on the front mimic of the panel - 01. Cable box for termination of cable up to 1 No. x 120 sq.mm - 01. Cable cover standard - 01. Set of 12kV Cable Termination Boots - 01. Cable entry bottom, front - 01
(B) (i) Out going VCB - 02 No consisting of following - function unit consist of vaccum circuit breaker in combination with a three position switch. The three position switch fulfills the operation of the disconnector function and earthing function circuits breaker unit is equipped with an over current transformer for the protection of distribution Transformer/circuit vaccum circuit breaker 12 KV, not less than 400 A, 21 KA - 01. Spring assisted closing with stored Energy triping mechanism for motorised operation with integrated earthing switch - 01. live cable LED indicators through capacitor voltage dividers mounted on the bushings push button for breaker trip - 01 sec O/C + E/F self powered numerical protection relay with low and High set for Over current and earth fault Relay should have facility to display the maximum loaded phase current also current also relay shall record minimum 5 fault records with time stamping - 01 Alram trip indication 6 window anuciator for transformer faults Mechanical ON/OFF/EARTH indication -01. Auxliary contacts on load switch are 1 No+2NC & Auxiliary conract on earth switch is 1 No+ 1NC-01. Self powered electronic numerical protection relay providing 3 over-currents & 1 E/F protection - 01, shunt trip coil 24 V DC-01 capactive voltage indication fixed type LED display -01 ON/OFF/Trip mechanical indication on the front mimic of panel-01 cable box for termination boots-01. Metering Equipment incl. 01 x Digital Voltmeter (Acc.Cl.0.5), 01 x Digital Ammeter (Acc.Cl.0.5), 01 x Tri-VectorMeter (Acc.Cl.0.5) for measuring of PF,KVAR,KVA, KWH ,frequency, voltage with accuracy 1.0 for avtive energy, Auxliary relay for transformer protection -06. The relay having faciliate to Transformer protection and connected with buchhol relay of Transformer complete all as specified and directed. (B) (ii) Out going RMU - 02 Nos, One consisting of CT 100/1 -5p10.2.5VA- 03. (C ) Additional equipment deliverd separately or mounted seperatly, Bus connected with battery charger and inbuilt battries for motor power supply-01 (i) PT ratio 11KV/3/110/v3, 100 va, 0.5 class for measurement with volts meter(ii) Auxliary transformer of 11KV/230V, 1 KVA for powering the motors and battery charger (iii ) 24 V DC battery charger and battries for motor power supply. Standard mano meter -01, Operating handle - 02 , cable clamping provision(standard)-01 Operation and maintance manual - o1, installation and commissioning manual - 01, cost of PCC works for placing RMU on plinth is deemed to be included in the cost, Height of plinth shouldnot be less than 0.45 mtrs from ground level.
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth strip 32 x6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test complete all as specified and directed by Engr-in-Charge. point all as specified or indicated including testing on completion.
Material & Labour for danger notice board of 1.6 mm thick mild steel,vitreous enamelled white with letters,figures and conventional skull and bones in signal red colour and fixed with MS clamps,bolts and nuts of approved size for HT 25 x 20 CM size complete all as specified and directed by Engr-in-Charge.
Supply and fixing screw bolts(machine made) with hexagonal or square heads at one end and screwed the other each screw to be fitted with one washers and one hexagonal or square nut length of bolts n.exc 5cm and dia of shank 10mm complete all as specified and directed by Engr-in-Charge.
Material & Labour for Cement concrete 1:3:6 type C-2 (using 20mm graded crushed stone aggregate) as in foundation filling and mass concrete as in channel/drains complete all as specified and directed by Engr-in-Charge.
Excavation in post holes n.exc 0.5 cum each getting out,returning filling in and ramming earth in layers n.exc 25cm watering and removing surplus soil to a distance n.exc 50m and making good surface in soft/loose soil complete all as specified and directed by Engr-in-Charge.
Supply only chain link MS galvanised fencing, any size or type Size is 50 x 50 mm Mesh Size with 4.00 mm Hot Dip G.I Wire. In this case, as per IS: 2721, etc complete all as specified and directed by Engr-in-Charge.
Fixing only chain link fencing including line wires, any mesh , size and type to any type of standards , rails , straining bolts, etc. including provision of binding wire complete all as specified and directed by Engr-in-Charge.
Material & Labour for two coats of synthetic enamel paint over a coat of primer including preparation of new steel surfaces of any description over 10cm girth or width complete all as specified and directed by Engr-in-Charge.
Supply & fixing in MS work such as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc and similar work conforming to Fe 290 Gde E-165 complete all as specified and directed by Engr-in-Charge.
Note : contractor should procure and provide 50 % of the material as listed above within 15 days of the placing of work order and shall be verified by the Engr-in-charge
M/s JAIMAA ASSOCIATES (BID ID -3113372)
MV Engineers And Contractors (BID ID -3100065)
Rajindera Enterprises (BID ID -3109917)
Vijay Electricals (BID ID -3110650)
M P TYAGI ENGINEERS AND CONTRACTORS (BID ID -3110368)
Commercial Traders (BID ID -3111608)
M/s VINOD KUMAR SHARMA (BID ID -3113348)
Ridhi engineers and builders (BID ID -3112484)
M/S VEDHANT ASSOCIATES (BID ID -3113209)
DS CONSTRUCTION (BID ID -3109430)
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .