| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.2 LAccepted-AOC 11 82 GROUND FLOOR BLOCK 11 KALYANPURI EAST DELHI DELHI 110091 | EAST DELHI | DELHI | 110091 | L1 | Accepted-AOC ACCEPTANCE | |
| 2 | L2₹40.7 L+₹76,380 (1.91%)Rejected-Finance S NO 279 1 1A PLOT NO 113 KUTWAL COLONY SASTHE WASTI LOHEGAON PUNE 411 047 | PUNE | MAHARASHTRA | 411047 | L2 | Rejected-Finance L2 | |
| 3 | L3₹41.6 L+₹1.6 L (4.00%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | L4₹42.4 L+₹2.4 L (6.04%)Rejected-Finance PITHORAGARH PIN 900 336 C O 56 APO | 900336 | L4 | Rejected-Finance L4 |
Tender Value
₹45.8 L
EMD Value
₹91,500
Closing Date
4 Sept 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
COL BHUPINDER SINGH CWE NAVY VASCO
CWE NAVY VASCO VASCO DA GAMA GOA 403802
PREMONSOON MAINT UPKEEP OF HT LT FEEDER UNDER AGE EM II OF GE(NW) VASCO
2024_MES_662150_1
85792/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
CWE NAVY VASCO
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE (NW) VASCO
₹91,500
Yes
20 Nov 2024
26 Jun 2024
6 Sept 2024
26 Jun 2024
4 Sept 2024
10 Jul 2024
Amount
M&L for outdoor type Gang Operated Air break switch triple pole, mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level with GI pipe medium grade, for current rating upto 200 Amps suitable for vertical mounting fixed type complete with 09 Nos HT insulators suitable for HT 11 KV complete all as specified and as directed.
S&F Cable jointing kit for 11KV grade cable for Outdoor end termination heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sq mm all as specified and as directed.
S&F Cable jointing kit for 11KV grade cable for Indoor end termination heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sq mm all as specified and as directed.
S&F Cable jointing kit for 11KV grade cable for Straight through joint heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sq mm all as specified and as directed.
M&L for taking out old coarse aggregate (broken stone or boulders) of any size and M&L for graded coarse aggregate of size 40 mm for spreading and leveling at substation yard all as specified and as directed.
Taking out burnt/UNSV Vaccum arc quenching chamber ,replacement & Installation with new vaccum arc quenching chamber with help of tools and safety gears of HT complete all as specified and directed.
Opening the UNSV VCB panel with the help of tools and properly cleaning the VCB with CRC-226 i.e- an electric contact cleaner, clean any old grease in the VCB , Check the condition of the fixed and floating contacts, inspect the positioning of the contacts. Replacement of Vacuum arc quenching chamber, Current terminals, traction insulator (spout), control element and electromagnetic actuator. Replacement of vacuum arc quenching chamber-02 Nos complete all as specified & directed.
Supply & Lay , Testing and Commissioning HT 11KV XLPE cable , PVC insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cable, heavy duty with aluminium conductor 11000 Volts grade (earthed), 3 core 95 sqmm laid in trenches / floor / duct / fixed on poles / through GI tubing including brass cable glands complete all as specified and as directed.
M&L for preparation of old cement coated surface, cleaning the surface of the RCC HT/LT pole above the ground level including coping area with 2 coats of exterior Emulsion paint over a coat of cement primer after preparation of surface including 12 cm black paint around the pole and pole number in red paint all as specified and as directed.
M&L for disc type insulator, single disc assembly, heavy polymeric insulator to suit 11 KV HT working Pressure of size 145 mm height, 255 mm dia , including one galvanized mild steel spindle, two galvanized iron washer and one GI nut complete including dismantling existing old insulator from position all as specified and as directed.
M&L for pin type heavy polymer insulator to suitable 11 KV HT of working pressure of size 150mm height, 150mm dia, including one galvanized mild steel spindle, two galvanished iron washer and one GI nut complete including dismantling existing old insulator from position all as specified and as directed.
M&L for post type heavy polymer insulator suitable for 11 KV HT working pressure including all connected accessories including dismantling existing old insulator from position all as specified and as directed.
Replacement of ACSR type jumpers(appx 1.5 RM to 2.0 RM in length) of suitable dia including aluminium lugs of suitable size for HT structures and yards including PVC insulation pipe and cleaning of carbon deposited on joints, applying jelly to each contact points and GOD male & female contacts and dismantling old jumpers complete all as specified and as directed.
Taking down 11 KV HT Drop out fuse assembly with DO Fuse unit and Triple pole Air break switch mechanism complete all as specified and as directed.
M&L for HT Drop out fuse assembly of 11 KV Current Rating of 200 Amps with 2 post type heavy polymer insulator per phase, double stack channel type including steel base mounting frame,new jumpers of ACSR with ends crimpled aluminium lugs, MS Nuts and bolts complete all as specified and as directed.
M&L for lightning arrestor (LA) zinc oxide type complete with all fittings transmission class, discharge capacity 10 KA, suitable for 12 KV complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying & removing of cable any sizes and getting out in hard/dense soil all as specified and as directed.
All as per Item No. 17 here in before but in soft disintegreted rock/ laterite rock all as specified and as directed.
Returning filling in excavated earth work including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in any strata all as specified and as directed.
Removing excavated soil to a distance not exceeding 50m, depositing where directed at a level not exceeding 1.5 m above the starting point all as specified and as directed.
Supply/ Lay dry river sand in trenches for cable protection all as specified and as directed. Note : Punned down thickness of sand only shall be measured & paid.
Supply and lay precast concrete cable covers,class HV,type- I flat size (300 x 180 x 40) mm all as specified and as directed.
Supply & Lay , Testing and Commissioning HT 11KV XLPE cable , PVC insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cable, heavy duty with aluminium conductor 11000 Volts grade (earthed), 3 core 120 sqmm laid in trenches / floor / duct / fixed on poles / through GI tubing including brass cable glands complete all as specified and as directed.
M & L preparation of old painted external surfaces of HT 2 pole structures consisting of cross arms, GOD assy with pipe, DO fuse assy, clamps etc., of any description and applying one coat of Aluminium paint by mannualy (Except PCC/RCC Pole) all as specified and as directed.
All as per item No 24 here in before but for 4 pole structure all as specified and as directed. Note for item No 24 to 25 :- This rate inclusive of painting all minor items such as clamps, brackets, nuts, bolts and washers which is not particularly mentioned in the structures & each job will be measured and paid.
Repair /replacement of defctive spares to made funtional the vaccum circuit breaker panel's troolleies installed at MRS NOFRA and under AGE (E/M)II complete all as specified and directed by Engr-in-Charge. Note:- The spares i.e- Vaccum intrrupter botteles (vaccum quenching chamber) will be paid and measured seperately. This item includes the replacement of charging spring, spouts , traction insulators, control element,electromagnetic actuator, defective closing button , replacement of charging handle, replacement of defective electronic trip relay , replacement of front cover of trolley, position indicator, drawout profile, auxilary relay, closing coil, gear lock, movable shunt, fixed contact, circuit breaker connection conductor etc
Carryout Material/machinaries & labour for fault finding of 33 KV or 11KV HT Under ground Cable of length up to 1.5 KM in case of cable fault such as short circuit / burn out of earth fault etc including carryout necessary hypot test by injecting high voltage up to 50 KV , complete all as specified and as directed. Note :- The contractor shall excavate the fault location and shall confirm the cable fault all as directed. Quoted rate deemed to be including charges for necessary T&P items, excavation & earthwork all as specified and as directed.
M & L for painting on surfaces of outdoor HT feeder pillar box by scrapping or with wire brush after preparing the surfaces by removing dust etc applying two coats of synthetic enamell paint over a coat of red oxide on the external surfaces of HT Feeder pillar box including writing "DANGER, HT 33 KV SUPPLY" all as specified and as directed.
Removing grass and bushes including its roots growing at Substation yard and keep the sub station yard neat and clean complete all as specified and as directed. Note:- one length shall be measured in six months.
Supply, Fixing and testing of metering & protection Current Transformer (CT) resin cast dry type indoor type of 11 KV capacity dual ratio 100-50/5 Amps, 15 VA burden class I accuracy for metering and 15 VA/5P-10 for protection including dismantling old existing CT all as specified and as directed.
Supply, Fixing and testing of metering & protection Potential Transformer (PT) resin cast dry type indoor type of 11 KV capacity ratio 11 KV/ 110 V, 200 VA burden including dismantling old existing PT all as specified and as directed.
M&L for servicing of 11KV VCB at Nofra & MAP Pahse 1, Kirti Enclave and P-404 dismantling cleaning greasing the complete VCB with attached numerical relays, bus bar etc insulation testing setting the contact gap by measuring as required reassembling the VCB and reinstalling back to its original position checking repairing the current circuit panel wiring ,relay testing and commissioning and provision of minor spares as required complete including operational testing and commissioning all as specified and directed.
M&L for replacement of the following for HT VCB 11 KV 800 A 25KA 250MVA all as directed including dismantling old unserviceable one.
a) Closing coil 30V DC
b) tripping coil 30V DC
c) control Relay 30V DC
d) LED type indicator lamp assembly
e) Vacuum Interupter for indoor VCB
f ) spout incoming side
g) spout outgoing side
M&L for primary injection test of 11 KV Current transformer and checking the electrical circuits for fault condition and proper functioning and also submitting the test report all as specified and as directed.
M&L for primary injection test of 11 KV Potential transformer by applying low voltage on HV Side including testing of secondary wiring for its healthiness all as specified and as directed. Note for Item Nos.34 to 35:- Testing and calibration of Relays, CTs, PTs etc shall be carried through OEM approved agencies and Original test results shall be submitted in triplicate.
M&L for primary injection test of 33 KV current transformer and checking the electrical circuits for fault condition and proper functioning and also submitting the test report all as specified and as directed.
M&L for primary injection test of 11 KV or 33 KV Potential transformer by applying low voltage on HV Side including testing of secondary wiring for its healthiness all as specified and as directed. Note for Item Nos.36 to 37:- Testing and calibration of Relays, CTs, PTs etc shall be carried through OEM approved agencies and Original test results shall be submitted in triplicate.
M&L for Mild steel cross arms, angles ,bracing supports ,clamps and back plates fabricated from structural steel sections including nut bolts washers welding bending cold or hot drilling hole for bolts in any shapes or size as indicated or directed and inclusive of one primer coat and one finishing coat of silver paint all as specified and as directed.
M&L for ACSR Conductor (ferret) as per required of side for LT/HT connection all as specified and as directed.
M&L for earthing complete with galvanized steel earth plate electrode of size 60cm x 60cm x 6 mm thick buried directly in ground earth pit not less than 3 m deep below the ground level with top edge of the plate n. less than 1.5 m below ground level and filling with cotton soil of volume 0.5 Cum brought from outside and Magnesium sulphate of 100 kg, salt of 100 kg and charcoal of 100 kg and connected to GI Strip 32 x 6 mm by means of bolts ,nuts ,checks nuts and washers of galvanized steel including necessary earth work and excavation in any strata and PCC 1:3:6 type C2 chamber and chamber RCC cover and light grade GI pipe 50 mm dia of required length for protection of GI strip and water funnel and wire mesh with GI pipe medium grade 20 mm dia etc complete all as per electrical plate No. 3 of SSR Part-I and as directed including connections and testing on completion all as specified and as directed. Note : GI earth strip upto 7.5 RM is included in the unit rate quoted.
Taking out old concrete poles of 11M long embedded in concrete upto bottom of foundation,Supply & Erect new Pre stressed concrete pole, 11 m long, 180 X 160 mm at top and 300 X 160 mm at bottom, class-9, erected in position complete all as specified and as directed.
M&L for PCC type D-2 , 1:4:8 using 40 mm graded stone aggregate including use and waste of form work of concrete for pole and stay foundation etc similaar works complete all as specified and as directed.
M&L for PCC type C-1, 1:3:6 using 20 mm graded stone aggregate including use and waste of form work for pole coping all as specified and as directed.
Supply only WD-40 spray of 420 ml for cleaning all as specified and as directed.
Supply only CRC spray of 500 ml for penetrates, lubricates and prevents corrosion from the metal all as specified and as directed.
Supply only electrical rubber hand gloves suitable on working pressure of 11 KV all as specified and as directed.
Suplly & Fix including taking down old UNSV Air Circuit Breaker at diffrent sub stations with new air circuit breaker of capacity 4 pole 415 V electrical drawout type of capacity 800 Amps 3 phase 4 wire 415 V electric supply withrated current of over current trip device of 800 Amp rated ultimate breaking / making capacity of 50 KA and rated service breaking/making capacity of 45 KA with thermal magnetic release complete all as specified & directed by Engr-in-Charge.
Suplly & Fix including taking down old UNSV Air Circuit Breaker at different sub stations with new air circuit breaker of capacity 4 pole 415 V electrical drawout type of capacity 1250 Amps 3 phase 4 wire 415 V electric supply withrated current of over current trip device of 1250 Amp rated ultimate breaking / making capacity of 50 KA and rated service breaking/making capacity of 45 KA with thermal magnetic release complete all as specified & directed by Engr-in-Charge.
Supply & Fix in repair Battery Manuel charger Unit of Rating 30 V, 20 A and AC input 230 V, 50 Hz single phase, DC output 34.5 V, 20 A including Dry type sealed maintenance free batteries rating of each battery 12 volt 100 AH with analog voltmeters, Ammeters etc all are fitted in suitable MS sheet enclosures hinged front operated type suitable for the operation of existing HT 33/11 KV VCB Outdoor/Indoor Panels.
S & F in repairs HT/LT cable route indicator standard size made out of MS disc size 4" size with MS Flat iron fixed with two nos of nut, bolt and washres and provision of PCC 1 : 4 : 8 type D-2 using 40 mm grade stone aggregate of not less than 0.05 cum in each at base buried under the ground incl necessary earth work complete all as specified and directed by Engr-in-charge
M&L for ACSR Conductor ( Reccon class) as per required of side for LT/HT connection all as specified and as directed.
Dismantling the RMU/VCB panel of 11 KV at Varunapuri power house/main receiving station with the help of proper HT switch gears and insulating the coating of bus bar after cleaning the VCB panel CT & PT and HT bus bar, applying anti tracking spary after application of HT tape (EPR high Vaoltage insulation tape) at the joints of HT cables and then apply insulating coat mixture alternate layer one by one i.e- super hydrophobic anti Track #906 Provar anti track-red, Tough deposit cleaner -carbon cleaner#8480, offline contact cleaner # SP98E2 safe klens (ELT), Part A high breakdown voltage solvent free EPOXY insulative STANGARD1311 INSULKOTE (Class A), Part B high breakdown voltage solvent free EPOXY insulative STANGARD1311 INSULKOTE (Class A), including providing new tripping coil and installation of the same complete all as specified & directed by Engr-in-Charge.
Shree Ram Enterprises (BID ID -3064639)
Shine Enterprises (BID ID -3067705)
Mahamaya Engineers Services (BID ID -3083095)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .