Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.6 LAccepted-AOC | L1 | Accepted-AOC Found lowest and reasonable | |
| 2 | L2₹36.9 L+₹1.4 L (4.03%)Rejected-Finance | L2 | Rejected-Finance In order but L2 | |
| 3 | L3₹38.3 L+₹2.8 L (7.92%)Rejected-Finance 164 197 NEWAJPUR DASAULI KURSI ROAD LUCKNOW UTTAR PRADESH 226026 | LUCKNOW | UTTAR PRADESH | 226026 | L3 | Rejected-Finance In order but L3 | |
| 4 | L4₹38.9 L+₹3.4 L (9.54%)Rejected-Finance H NO 206 RAJAPUR DUJANIA MOHALLA DASNA DEHAT VILLAGE TOWN INDERGARHI CITY GHAZIABAD GHAZIABAD UTTAR PRADESH 201002 INDIA | GHAZIABAD | UTTAR PRADESH | 201002 | L4 | Rejected-Finance In order but L4 | |
| 5 | L5₹39.4 L+₹3.9 L (11.0%)Rejected-Finance 289 KASERU KHERA MAWANA ROAD MEERUT 250001 U P | MEERUT | UTTAR PRADESH | 250001 | L5 | Rejected-Finance In order but L5 |
| Sl No | Description | Qty | Unit | janta tradrers L6 | Shikha Enterprises L5 | NITHYA INFRATECH L1 | SIYA ASSOCIATES L3 | PRABHAT ENGINEERING SOLUTION AND SERVICES L7 | KUKREJA BROTHERS L8 | PARADISE INFRA POWER COMPANY L4 | M/S ROORKEE ENGINEERING L2 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply, installing, testing and commissioning, factory made and tested, LT Panel (KIOSK), outdoor type, minium size 1200 x 600x 900mm and platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated aluminum bus bars 1000 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof, IP 65 class protection and SMC/made of 3.15mm MS sheet and 50x50x5mm thick angle iron frame work, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, both side front opening type, with aprons for cable entry, with double door shutter and locking arrangement , back side grill support internal wiring with PVC insulated, stranded copper conductor, FRLS cables, IS-694 marked of adequate size but not less than 2.5 Sqmm. The platform shall be such that it is of a height 45 cm above the nearest road level. complete all as specified and directed including connections of all out going/in coming existing cables of size 25 to 240 sqmm by drawing /digging out cable from loops in trenches out side the Bldg including of necessary excavation and earth work as required and relaying the cables with retrieved bricks and providing new sand cushioning and crimping suitable size lugs for terminal connections of cables, necessary brick foundation with plastering to the Panel board, All out going feeders shall be connected and both side fixing danger notice plate made of 1.6mm thick mild steel sheet, vitreous enameled white, of size 20 x 15cm with letter, figures and conventional skull bones in signal red colour and fixed front & back door pillar box etc with voltage and danger indiated in Hindi and English complete all as specified including taking out of old unsv any type panel with control switches complete all as specified and as directed by Engr-in-Charge , The scope of work includes the following: (NOTE:-LT Panel board should be as per IS/ICE 61439-part I&II Type Test certificates for 4000 Amp with breaking capacity not less than 65 KVA and panels Builder should submit all Certificates before executing the job.) | 1 | Each | 2,35,000 ₹2,35,000 Lowest | 2,74,333 ₹2,74,333 | 2,63,500 ₹2,63,500 | 2,85,111 ₹2,85,111 | 5,60,000 ₹5,60,000 | 2,70,000 ₹2,70,000 | 2,53,750 ₹2,53,750 | 3,25,000 ₹3,25,000 |
| 1.01 | (A) Incoming :-
(i) ACB 4 Pole, Thermal Magnetic adjustable type based 630 A, Breaking capacity 50 KA, 415 V, 50 Hz with OL, SC protection, -01 No
(ii) Digital Amps/volt /PF meter 0-650 volts with selector switch - 01 No
(iii) Indicator lamp LED type (R, Y, B) complete with fuse -01 Set | - | - | - | - | - | - | - | - | - | - |
| 1.02 | (B) Outgoing :-
(i) MCCB 4 Pole, Thermal Magnetic Based 315 A, Breaking capacity 36 KA, 415 V, 50 Hz with OL, SC protection, -01 No along with Spreader terminals.
(ii) MCCB 4 Pole, Thermal Magnetic Based 250 A, Breaking capacity 36 KA, 415 V, 50 Hz with OL, SC protection protection, -01No along with Spreader terminals.
(iii) MCCB 4 Pole, Thermal Magnetic Based 200 A, Breaking capacity 25 KA, 415 V, 50 Hz with OL, SC protection protection, -01No along with Spreader terminals.
(iv) MCCB 4 Pole, Thermal Magnetic Based 160 A, Breaking capacity 25 KA, 415 V, 50 Hz with OL, SC protection protection, -01No along with Spreader terminals.
(v) MCCB 4 Pole, Thermal Magnetic Based 160 A, Breaking capacit 25 KA, 415 V, 50 Hz with OL, SC protection protection, -01No along with Spreader terminals.
(vi) Indicator lamp LED type (R, Y, B) complete with fuse -05 Set. | - | - | - | - | - | - | - | - | - | - |
| 2.00 | Supply, installing, testing and commissioning, factory made and tested , LT Panel (KIOSK), outdoor type, minium size 1200 x 600x 900mm and platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated aluminum bus bars 640 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof, IP 65 class protection and SMC/made of 3.15mm MS sheet and 50x50x5mm thick angle iron frame work, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, both side front opening type, with aprons for cable entry, with double door shutter and locking arrangement , back side grill support internal wiring with PVC insulated, stranded copper conductor, FRLS cables, IS-694 marked of adequate size but not less than 2.5 Sqmm. The platform shall be such that it is of a height 45 cm above the nearest road level. complete all as specified and directed including connections of all out going/in coming existing cables of size 25 to 240 sqmm by drawing /digging out cable from loops in trenches out side the Bldg including of necessary excavation and earth work as required and relaying the cables with retrieved bricks and providing new sand cushioning and crimping suitable size lugs for terminal connections of cables, necessary brick foundation with plastering to the Panel board, All out going feeders shall be connected and both side fixing danger notice plate made of 1.6mm thick mild steel sheet, vitreous enameled white, of size 20 x 15cm with letter, figures and conventional skull bones in signal red colour and fixed front & back door pillar box etc with voltage and danger indiated in Hindi and English complete all as specified and as directed by Engr-in-Charge , The scope of work includes the following: (NOTE:-LT Panel board should be as per IS/ICE 61439-part I&II Type Test certificates for 4000 Amp with breaking capacity not less than 65 KVA and panels Builder should submit all Certificates before executing the job.) | 1 | Each | 1,21,000 ₹1,21,000 | 1,48,155 ₹1,48,155 | 1,35,000 ₹1,35,000 | 1,55,111 ₹1,55,111 | 2,25,000 ₹2,25,000 | 1,24,000 ₹1,24,000 | 1,07,500 ₹1,07,500 Lowest | 1,50,000 ₹1,50,000 |
| 2.01 | (A) Incoming :-
(i) MCCB 4 Pole, Thermal Magnetic adjustable type based 400 A, Breaking capacity 36 KA, 415 V, 50 Hz with OL, SC protection, -01 No along with Spreader terminals.
(ii) Digital Amps/volt /PF meter 0-500 volts with selector switch - 01 No
(iii) Indicator lamp LED type (R, Y, B) complete with fuse -01 Set. | - | - | - | - | - | - | - | - | - | - |
| 2.02 | (B) Outgoing :-
(i) MCCB 4 Pole, Thermal Magnetic adjustable type based 300 A, Breaking capacity 36 KA, 415 V, 50 Hz with OL, SC protection, -02 No along with Spreader terminals.
(ii) MCCB 4 Pole, Thermal Magnetic Based 100 A, Breaking capacity 16 KA, 415 V, 50 Hz with OL, SC protection, -02No along with Spreader terminals.
(iii) MCB TPN 40 Amp C-Curve - 1 No | - | - | - | - | - | - | - | - | - | - |
| 3.00 | Supply, installing, testing and commissioning, factory made and tested , LT Panel (KIOSK), outdoor type, minium size 1200 x 600x 900mm and platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated aluminum bus bars 500 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof, IP 65 class protection and SMC/made of 3.15mm MS sheet and 50x50x5mm thick angle iron frame work, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, both side front opening type, with aprons for cable entry, with double door shutter and locking arrangement , back side grill support internal wiring with PVC insulated, stranded copper conductor, FRLS cables, IS-694 marked of adequate size but not less than 2.5 Sqmm. The platform shall be such that it is of a height 45 cm above the nearest road level. complete all as specified and directed including connections of all out going/in coming existing cables of size 25 to 240 sqmm by drawing /digging out cable from loops in trenches out side the Bldg including of necessary excavation and earth work as required and relaying the cables with retrieved bricks and providing new sand cushioning and crimping suitable size lugs for terminal connections of cables, necessary brick foundation with plastering to the Panel board, All out going feeders shall be connected and both side fixing danger notice plate made of 1.6mm thick mild steel sheet, vitreous enameled white, of size 20 x 15cm with letter, figures and conventional skull bones in signal red colour and fixed front & back door pillar box etc with voltage and danger indiated in Hindi and English complete all as specified and as directed by Engr-in-Charge , The scope of work includes the following: (NOTE:-LT Panel board should be as per IS/ICE 61439-part I&II Type Test certificates for 4000 Amp with breaking capacity not less than 65 KVA and panels Builder should submit all Certificates before executing the job.) | 1 | Each | 99,800 ₹99,800 | 1,13,333 ₹1,13,333 | 99,500 ₹99,500 | 98,111 ₹98,111 | 1,60,000 ₹1,60,000 | 1,00,000 ₹1,00,000 | 90,000 ₹90,000 Lowest | 1,25,000 ₹1,25,000 |
| 3.01 | (A) Incoming :-
(i) MCCB 4 Pole, Thermal Magnetic Based 315 A, Breaking capacity 36 KA, 415 V, 50 Hz with OL, SC protection, -01 No along with Spreader terminals.
(ii) Digital Amps/volt /PF meter 0-350 volts with selector switch - 01 No.
(iii) Indicator lamp LED type (R, Y, B) complete with fuse -01 Set. | - | - | - | - | - | - | - | - | - | - |
| 3.02 | (B) Outgoing :-
(i) MCCB 4 Pole, Thermal Magnetic adjustable type Based 160 A, Breaking capacity 25 KA, 415 V, 50 Hz with OL, SC protection, -02 No along with Spreader terminals.
(ii) MCCB 4 Pole, Thermal Magnetic Based 100 A, Breaking capacity 16 KA, 415 V, 50 Hz with OL, SC protection, -01No along with Spreader terminals.
(iii) MCB TPN 40 Amp C-Curve - 1 No. | - | - | - | - | - | - | - | - | - | - |
| 4.00 | Supply, installing, testing and commissioning, factory made and tested , LT Panel (KIOSK), outdoor type, minium size 1200 x 600x 900mm and platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated aluminum bus bars 320 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof, IP 65 class protection and SMC/made of 3.15mm MS sheet and 50x50x5mm thick angle iron frame work, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, both side front opening type, with aprons for cable entry, with double door shutter and locking arrangement , back side grill support internal wiring with PVC insulated, stranded copper conductor, FRLS cables, IS-694 marked of adequate size but not less than 2.5 Sqmm. The platform shall be such that it is of a height 45 cm above the nearest road level. complete all as specified and directed including connections of all out going/in coming existing cables of size 25 to 240 sqmm by drawing /digging out cable from loops in trenches out side the Bldg including of necessary excavation and earth work as required and relaying the cables with retrieved bricks and providing new sand cushioning and crimping suitable size lugs for terminal connections of cables, necessary brick foundation with plastering to the Panel board, All out going feeders shall be connected and both side fixing danger notice plate made of 1.6mm thick mild steel sheet, vitreous enameled white, of size 20 x 15cm with letter, figures and conventional skull bones in signal red colour and fixed front & back door pillar box etc with voltage and danger indiated in Hindi and English complete all as specified and as directed by Engr-in-Charge , The scope of work includes the following: (NOTE:-LT Panel board should be as per IS/ICE 61439-part I&II Type Test certificates for 4000 Amp with breaking capacity not less than 65 KVA and panels Builder should submit all Certificates before executing the job.) | 1 | Each | 65,000 ₹65,000 Lowest | 78,333 ₹78,333 | 79,800 ₹79,800 | 77,111 ₹77,111 | 1,40,000 ₹1,40,000 | 78,000 ₹78,000 | 70,000 ₹70,000 | 1,25,000 ₹1,25,000 |
Tender Value
₹46.7 L
EMD Value
₹93,400
Closing Date
14 Aug 2025, 6:00 pmClosed
GE (U) Meerut Cantt
Roorkee road Meerut Cantt
SPL REPAIR/ REPLACEMENT OF UNSV SOLAR STREET LIGHT OF 40 NOS WITH INBUILT BATTERY SOLAR LIGHT OF 336 FD REGT AND SPL REPAIR REPLACEMENT OF LT OH LINE OLD U/S LT CABLE AND ALLIED WORKS AT RVC CENTRE AND COLLAGE OFFR MESS AREA UNDER GE(U) MEERUT CANTT.
2025_MES_720905_1
8714/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Meerut Cantt
Please refer Tender documents.
12 documents required · 12 mandatory
₹500
GE (U) Meeerut Cantt
₹93,400
Yes
4 Oct 2025
17 Jul 2025
21 Aug 2025
17 Jul 2025
14 Aug 2025
31 Jul 2025
Amount
Supply, installing, testing and commissioning, factory made and tested, LT Panel (KIOSK), outdoor type, minium size 1200 x 600x 900mm and platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated aluminum bus bars 1000 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof, IP 65 class protection and SMC/made of 3.15mm MS sheet and 50x50x5mm thick angle iron frame work, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, both side front opening type, with aprons for cable entry, with double door shutter and locking arrangement , back side grill support internal wiring with PVC insulated, stranded copper conductor, FRLS cables, IS-694 marked of adequate size but not less than 2.5 Sqmm. The platform shall be such that it is of a height 45 cm above the nearest road level. complete all as specified and directed including connections of all out going/in coming existing cables of size 25 to 240 sqmm by drawing /digging out cable from loops in trenches out side the Bldg including of necessary excavation and earth work as required and relaying the cables with retrieved bricks and providing new sand cushioning and crimping suitable size lugs for terminal connections of cables, necessary brick foundation with plastering to the Panel board, All out going feeders shall be connected and both side fixing danger notice plate made of 1.6mm thick mild steel sheet, vitreous enameled white, of size 20 x 15cm with letter, figures and conventional skull bones in signal red colour and fixed front & back door pillar box etc with voltage and danger indiated in Hindi and English complete all as specified including taking out of old unsv any type panel with control switches complete all as specified and as directed by Engr-in-Charge , The scope of work includes the following: (NOTE:-LT Panel board should be as per IS/ICE 61439-part I&II Type Test certificates for 4000 Amp with breaking capacity not less than 65 KVA and panels Builder should submit all Certificates before executing the job.)
(B) Outgoing :- (i) MCCB 4 Pole, Thermal Magnetic Based 315 A, Breaking capacity 36 KA, 415 V, 50 Hz with OL, SC protection, -01 No along with Spreader terminals. (ii) MCCB 4 Pole, Thermal Magnetic Based 250 A, Breaking capacity 36 KA, 415 V, 50 Hz with OL, SC protection protection, -01No along with Spreader terminals. (iii) MCCB 4 Pole, Thermal Magnetic Based 200 A, Breaking capacity 25 KA, 415 V, 50 Hz with OL, SC protection protection, -01No along with Spreader terminals. (iv) MCCB 4 Pole, Thermal Magnetic Based 160 A, Breaking capacity 25 KA, 415 V, 50 Hz with OL, SC protection protection, -01No along with Spreader terminals. (v) MCCB 4 Pole, Thermal Magnetic Based 160 A, Breaking capacit 25 KA, 415 V, 50 Hz with OL, SC protection protection, -01No along with Spreader terminals. (vi) Indicator lamp LED type (R, Y, B) complete with fuse -05 Set.
Supply, installing, testing and commissioning, factory made and tested , LT Panel (KIOSK), outdoor type, minium size 1200 x 600x 900mm and platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated aluminum bus bars 640 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof, IP 65 class protection and SMC/made of 3.15mm MS sheet and 50x50x5mm thick angle iron frame work, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, both side front opening type, with aprons for cable entry, with double door shutter and locking arrangement , back side grill support internal wiring with PVC insulated, stranded copper conductor, FRLS cables, IS-694 marked of adequate size but not less than 2.5 Sqmm. The platform shall be such that it is of a height 45 cm above the nearest road level. complete all as specified and directed including connections of all out going/in coming existing cables of size 25 to 240 sqmm by drawing /digging out cable from loops in trenches out side the Bldg including of necessary excavation and earth work as required and relaying the cables with retrieved bricks and providing new sand cushioning and crimping suitable size lugs for terminal connections of cables, necessary brick foundation with plastering to the Panel board, All out going feeders shall be connected and both side fixing danger notice plate made of 1.6mm thick mild steel sheet, vitreous enameled white, of size 20 x 15cm with letter, figures and conventional skull bones in signal red colour and fixed front & back door pillar box etc with voltage and danger indiated in Hindi and English complete all as specified and as directed by Engr-in-Charge , The scope of work includes the following: (NOTE:-LT Panel board should be as per IS/ICE 61439-part I&II Type Test certificates for 4000 Amp with breaking capacity not less than 65 KVA and panels Builder should submit all Certificates before executing the job.)
(B) Outgoing :- (i) MCCB 4 Pole, Thermal Magnetic adjustable type based 300 A, Breaking capacity 36 KA, 415 V, 50 Hz with OL, SC protection, -02 No along with Spreader terminals. (ii) MCCB 4 Pole, Thermal Magnetic Based 100 A, Breaking capacity 16 KA, 415 V, 50 Hz with OL, SC protection, -02No along with Spreader terminals. (iii) MCB TPN 40 Amp C-Curve - 1 No
Supply, installing, testing and commissioning, factory made and tested , LT Panel (KIOSK), outdoor type, minium size 1200 x 600x 900mm and platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated aluminum bus bars 500 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof, IP 65 class protection and SMC/made of 3.15mm MS sheet and 50x50x5mm thick angle iron frame work, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, both side front opening type, with aprons for cable entry, with double door shutter and locking arrangement , back side grill support internal wiring with PVC insulated, stranded copper conductor, FRLS cables, IS-694 marked of adequate size but not less than 2.5 Sqmm. The platform shall be such that it is of a height 45 cm above the nearest road level. complete all as specified and directed including connections of all out going/in coming existing cables of size 25 to 240 sqmm by drawing /digging out cable from loops in trenches out side the Bldg including of necessary excavation and earth work as required and relaying the cables with retrieved bricks and providing new sand cushioning and crimping suitable size lugs for terminal connections of cables, necessary brick foundation with plastering to the Panel board, All out going feeders shall be connected and both side fixing danger notice plate made of 1.6mm thick mild steel sheet, vitreous enameled white, of size 20 x 15cm with letter, figures and conventional skull bones in signal red colour and fixed front & back door pillar box etc with voltage and danger indiated in Hindi and English complete all as specified and as directed by Engr-in-Charge , The scope of work includes the following: (NOTE:-LT Panel board should be as per IS/ICE 61439-part I&II Type Test certificates for 4000 Amp with breaking capacity not less than 65 KVA and panels Builder should submit all Certificates before executing the job.)
(B) Outgoing :- (i) MCCB 4 Pole, Thermal Magnetic adjustable type Based 160 A, Breaking capacity 25 KA, 415 V, 50 Hz with OL, SC protection, -02 No along with Spreader terminals. (ii) MCCB 4 Pole, Thermal Magnetic Based 100 A, Breaking capacity 16 KA, 415 V, 50 Hz with OL, SC protection, -01No along with Spreader terminals. (iii) MCB TPN 40 Amp C-Curve - 1 No.
Supply, installing, testing and commissioning, factory made and tested , LT Panel (KIOSK), outdoor type, minium size 1200 x 600x 900mm and platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated aluminum bus bars 320 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof, IP 65 class protection and SMC/made of 3.15mm MS sheet and 50x50x5mm thick angle iron frame work, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, both side front opening type, with aprons for cable entry, with double door shutter and locking arrangement , back side grill support internal wiring with PVC insulated, stranded copper conductor, FRLS cables, IS-694 marked of adequate size but not less than 2.5 Sqmm. The platform shall be such that it is of a height 45 cm above the nearest road level. complete all as specified and directed including connections of all out going/in coming existing cables of size 25 to 240 sqmm by drawing /digging out cable from loops in trenches out side the Bldg including of necessary excavation and earth work as required and relaying the cables with retrieved bricks and providing new sand cushioning and crimping suitable size lugs for terminal connections of cables, necessary brick foundation with plastering to the Panel board, All out going feeders shall be connected and both side fixing danger notice plate made of 1.6mm thick mild steel sheet, vitreous enameled white, of size 20 x 15cm with letter, figures and conventional skull bones in signal red colour and fixed front & back door pillar box etc with voltage and danger indiated in Hindi and English complete all as specified and as directed by Engr-in-Charge , The scope of work includes the following: (NOTE:-LT Panel board should be as per IS/ICE 61439-part I&II Type Test certificates for 4000 Amp with breaking capacity not less than 65 KVA and panels Builder should submit all Certificates before executing the job.)
(B) Outgoing :- (i) MCCB 4 Pole, Thermal Magnetic adjustable type Based 160 A, Breaking capacity 25 KA, 415 V, 50 Hz with OL, SC protection, -01 No along with Spreader terminals. (ii) MCCB 4 Pole, Thermal Magnetic Based 100 A, Breaking capacity 16 KA, 415 V, 50 Hz with OL, SC protection, -01No along with Spreader terminals. (iii) MCB TPN 40 Amp C-Curve - 1 No.
Supply, installing, testing and commissioning, factory made and tested , LT Panel (KIOSK), outdoor type, minium size 1200 x 600x 900mm and platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated aluminum bus bars 400 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof, IP 65 class protection and SMC/made of 3.15mm MS sheet and 50x50x5mm thick angle iron frame work, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, both side front opening type, with aprons for cable entry, with double door shutter and locking arrangement , back side grill support internal wiring with PVC insulated, stranded copper conductor, FRLS cables, IS-694 marked of adequate size but not less than 2.5 Sqmm. The platform shall be such that it is of a height 45 cm above the nearest road level. complete all as specified and directed including connections of all out going/in coming existing cables of size 25 to 240 sqmm by drawing /digging out cable from loops in trenches out side the Bldg including of necessary excavation and earth work as required and relaying the cables with retrieved bricks and providing new sand cushioning and crimping suitable size lugs for terminal connections of cables, necessary brick foundation with plastering to the Panel board, All out going feeders shall be connected and both side fixing danger notice plate made of 1.6mm thick mild steel sheet, vitreous enameled white, of size 20 x 15cm with letter, figures and conventional skull bones in signal red colour and fixed front & back door pillar box etc with voltage and danger indiated in Hindi and English complete all as specified and as directed by Engr-in-Charge , The scope of work includes the following: (NOTE:-LT Panel board should be as per IS/ICE 61439-part I&II Type Test certificates for 4000 Amp with breaking capacity not less than 65 KVA and panels Builder should submit all Certificates before executing the job.)
(B) Outgoing :- (i) MCCB 4 Pole, Thermal Magnetic adjustable type Based 200 A, Breaking capacity 25 KA, 415 V, 50 Hz with OL, SC protection, -01 No along with Spreader terminals. (ii) MCCB 4 Pole, Thermal Magnetic Based 100 A, Breaking capacity 16 KA, 415 V, 50 Hz with OL, SC protection, -01No along with Spreader terminals. (iii) MCB TPN 63 Amp C-Curve - 1 No.
Supply, installing, testing and commissioning of LT out door type factory made(CPRI Approved ), junction box of size 750mmX600mmX500mm (over all dimension )with mild steel angle iron of size 50X50X6mm vertical frame and legs with mild steel Angel iron 50x50X6 mm in horizontal sides of the frame LT Junction box (KIOSK), outdoor type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system,The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15mm MS sheet and 50x50x6 mm thick angle iron frame work, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, front & back opening type, both side with aprons for cable entry, and fixing danger notice plate made of 1.6mm thick mild steel sheet, vitreous enameled white, of size 20 x 15cm with letter, figures and conventional skull bones in signal red colour and fixed front & back door pillar box back side grill support etc with voltage and danger indicated in Hindi and English complete all as specified and directed.with double door shutter and locking arrangement. Aluminium bus bar (LxWxH) 400 x 10x50 mm with drilled holes for incoming /out going cable core connection including aluminium lugs, GI bolts, Nuts and washers of suitable size . Porcelain / synthetic bridge insulators, heavy duty with necessary steel / GI screws, bolts, nuts and washers, complete all as specified and as directed. The platform shall be such that it is of a height 45 cm above the nearest road level. complete all as specified and directed including connections of all out going/in coming existing cables of size 25 to 300 sqmm by drawing /digging out cable from loops in trenches out side the Bldg inclusive of necessary excavation and earth work as required and relaying the cables with retrieved bricks and providing new sand cushioning and crimping suitable size lugs for terminal connections of cables, necessary brick foundation with plastering to the Panel board complete all as specified and as directed by Engr-in-Charge (NOTE:-LT Panel board should be as per IS/ICE 61439-part I&II Type Test certificates for 4000 Amp with breaking capacity not less than 65 KVA and panels Builder should submit all Certificates before executing the job.)
M&L for earthing for LT panel complete with galvanised mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.5 m below normal ground level) with the top edge of the earth plate at a depth not less than 1.5 m below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and incl GI earth strip 32 x 6 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth plate at one end and connected to metallic bodies of LT equipments etc at the other, earth strip encased in and including 40mm bore GI light grade pipe with all fittings from top of electrode to body of equipment fixed with and including 25 x 3mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from bottom of earth pit to top of electrode complete with earth pit in PCC 1:2:4 type B-O using 12 mm graded crushed stone aggregate excavation & earth work and RCC cover complete all specified and shown in electrical plate No 3 of SSR Pt-I.
Supply, laying, jointing, testing and commissioning LT underground cables, 1100 volts grade, XLPE insulated and PVC sheathed, heavy duty armoured, with multistranded aluminium conductors, IS-7098 (ISI marked) laid in trenches / ducts / fixed on poles / walls / laid under roads / paths / drain / culverts or encased in GI pipe complete all as specified and directed. Cables of the following sizes:-(Note:- (i) Rate quotted includes terminal Lugs / road cutting/ wall cutting/ floor cutting and making good damged portion matching with existing surface with all existing finishes (ii) Excavation & earth work, sand cushioning, brick cover & protection pipe etc shall be measured and paid separately .
16 Sqmm 4core
50 Sqmm 4 core
95 Sqmm 3.5 core
120 Sqmm 3.5 core
150 Sqmm 3.5 core
185 Sqmm 3.5 core
240 Sqmm 3.5 core
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and getting out in Soft/Loose soil including trimming sides and bottom of trenches complete all as specifiedand directed.
All as per item srl No 09 but in depth beyond 1.5 Mtr and n. exc 3.00 Mtr and taking out in any type of soil complete all as specified and directed.
Returning, filling-in, including spreading, watering and well ramming in layers not exceeding 25 cm thick each, in soft /loose soil complete all as specified in the following type of soils complete all as specified and directed.
Removing excavated surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Material and labour for river washed and screened, dry sand for filling in trenches below 8 cm laid before laying of cable & 15 cm laid after laying the cable and around underground cables for cushioning of cables complete all as specified and directed. Note:- Punned thickness shall be measured for payment.
M & L Bricks for protection cover to under ground cable (with standard size fly ash bricks) with width equal to length of brick laid dry and flat abutting each other with gaps between adjacent brick not exceeding 10mm complete all as specified and directed.
Supply and laying galvanised steel tubing, light grade, IS-1239 marked with all fittings (IS marked) and laid in trenches / under roads / in drains / fixed to poles/walls ( with required size flat iron clamp bolts, nuts and washers ) pipes of the following sizes :-
50 mm bore
80 mm bore
100 mm bore
M&L for auguring of hole suitable for passing 40mm to 100mm bore pipe in true horizontal position under road, PCC paths etc., by means of mechanical ring/ auger after doing ultrasound to prevent any damage to existing cables pipe line specified and directed coming in the route not exceeding 1.5 m in depth below existing surface level of road and not excd 30M in length complete all as specified. Note: Pipe shall be measured and paid separately under appropriate items and any damage to existing cables of anytype shall be made good by the Bidder without any extra cost to department complete all as specified and directed.
Cutting of worn-out / burnt aluminium cable terminal lugs from the HT/LT cable , crimping of new aluminium cable core and fixing with transformer/ Panel MCCB terminal/ FPB/ JB/ pole/DBs/ stud including cutting/ dressing of cable, disconnecting under ground / OH line cable conductor , cutting down worn-out portion and refixing with suitable lugs complete , including under ground cables of any type and size for repairs including taking out underground cable loop from ground and making connections of restoration of electric supply complete all as specified and directed Engr-in-Charge .
S&F service main distribution (SMC JUNCTION BOX ) box minimum inside size 395 x 235 x 150 mm with Bus bar 200 amps 4 pole for distribution of multiple nos of service connection, (ISI marked )weather and moisture-proof, nuts and bolted bus bar system, 200 Amps capacity and fixing on pole/wall with suitable FI clamp nuts and bolt complete all as specified and directed.
S&F pole mounting type junction box factory made of size 300x200x100mm of FRP sheet duly powder coated with front openable hinged door , locking arrangements, with 4 Nos aluminium bus bars 40 Amps rating mounted on porcelain insulator, cable glands and lugs consisting DIN type rails for fixing MCB DP 6 Amps, 10 kA C -curve -01 no. including mild steel flat iron clamp made out of 40x4mm FI, nuts, bolts and washers duly painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed Engr in Charge.
Supply and fixing copper three core 1.5 Sqmm x3 core (nominal area) Confirming to FRLS cables, IS-9098 (part-I), PVC insulated and PVC sheathed multi stranded unarmed conductor cable LT 1100 volt grade including removed unsv any type cable complete all as specified and as directed by Engr in charge
Supplying and fixing street light timing switch having lighting control (ON-OFF) through Analise timer switch Calculation of Sun rise/ sun set by setting date, time and degree of longitude and latitude without separate light sensors and prewired with suitable size of copper conductor single core PVC insulated and sheathed cable and all mechanism fitted into panel, outdoor type , pole mounted with FI 25x4mm clamps , nuts, bolts and washers dully painted, connecting and testing factory made , epoxy powder coated, Single Phase street light panel, digital 24 hrs, suitable for 6KW (max) complete with 63 Amps TP Contactor, and 63 Amps TPN MCBs and fixed on pole/ wall/ feeder pillar complete all as specified and directed by Engr in Charge
Relaying, jointing, testing and commissioning LT underground cables any size , 1100 volts grade, XLPE insulated and PVC sheathed, heavy duty armoured, with multistranded aluminium conductors, ( laid in trenches / ducts / fixed on poles / walls / laid under roads / paths / drain / culverts or encased in GI pipe complete all as specified and directed. -(Note:- (i) Rate quotted includes terminal Lugs / road cutting/ wall cutting/ floor cutting and making good damged portion matching with existing surface (ii) Excavation & earth work, sand cushioning, brick cover & protection pipe etc shall be measured and paid separately .
Taking down old unsv LT underground cables, any type and size from trenches / ducts / poles / walls /roads / paths / drain / culverts or encased in GI pipe a complete all as specified and directed. (Note;- Rate quotted includes Excavation/ road cutting/ wall cutting/ floor cutting and making good damged portion matching with existing surface with all existing finishes.)
Dismantling old existing ACSR conductor of any type/size.
Dismantling old existing MS cross arms of any type/shape.
Dismantling old existing Insulators of any type/shape.
Dismantling old existing LT stay complete
Supply, installing,commissioning and testing 100W Solar AIO LED Street Light on existing Pole with luminair efficacy of 150 lm/W with minimum lumen output of 15000 lumens.The solar panel should of 150W with Monocrystalline cells with 78Ah LiFePO4 battery pack. Manufacturers Logo/name must be engraved/Embossed on luminaire Housing. Manufacturer must have In-House NABL accredited laboratory with scope of testing & callibration of Electrical, Mechanical & Photometry Parameters as per IS10322:2012, IS16104, IS16106, IEC60598-1, IEC62262:2002,IEC60068-2-75, IEC60529, IES LM79, IS16102 (Part 2, Clause 8).Solar light fitting should be reliable to fit on any size of GI Pipe/Wall compleate all as directed by Engr-in-charge. Note:- The bidder should submitt below documents along with Technical bidd 1) LM79 Report from NABL Accredited Lab of Light supplied. 2) Technical Data Sheet of Solar Street Light. 3) Type Test Report of Solar Street Light. 4) BIS Certificate of Battery. 5) LM80 Report of LED Chip used in fixture. 6) Datat Sheet of LED Chip used in fixture.
M&L for PCC (1:3:6) type C2 using 40mm graded stone aggregated as in foundation, filling and mass concrete using necessary form work for existing light poles damaged foundation complete all as specified and directed by Engr-in-Charge.
M&L for PCC (1:4:8) type D2 using 40mm graded stone aggregated as in foundation, filling and mass concrete using necessary form work for existing light poles damaged foundation complete all as directed by Engr-in-Charge.
M&L for plain cement concrete type B1 ( 1:2:4) using 20 mm graded stone aggregate as cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railing upto 60 cm in height, copings, kneelers, apex stones, bed plates, coping/ plinth to existing light poles damaged coping and the like including weathering , slightly rounded or chamfered angles and throating and painting the same as directed including necessary formwork complete all as specified and directed.
M&L for earthing complete with galvanised steel earth Coil of 50 mm dia have 115 turns, burried directly in to ground ( earth pit size should be 1500mm X 600mm + size of coil) not less than 1500 mm + Coil Size deep below GL with top edge of earth coil not less than 1500mm below ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 600mm all around the coil, connected to GI lead wire of 4 mm dia (1.75 m Long) by means of nuts, bolts and washers, checknuts of GI and distance of the earthing bore from the pole should be 1200mm Minimum compleate all as specified and directed by engineer-in-charge.
M/S ROORKEE ENGINEERING (BID ID -3384306)
SIYA ASSOCIATES (BID ID -3386453)
PARADISE INFRA POWER COMPANY (BID ID -3385080)
Shikha Enterprises (BID ID -3393779)
janta tradrers (BID ID -3386009)
PRABHAT ENGINEERING SOLUTION AND SERVICES (BID ID -3393920)
KUKREJA BROTHERS (BID ID -3385596)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .