Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.6 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹28.7 L+₹2.4 L (9.17%)Rejected-Finance | L2 | Rejected-Finance Rejected | |
| 3 | L3₹28.9 L+₹2.6 L (9.91%)Rejected-Finance | L3 | Rejected-Finance Rejected | |
| 4 | L4₹29.4 L+₹3.1 L (11.9%)Rejected-Finance | L4 | Rejected-Finance Rejected | |
| 5 | L5₹29.9 L+₹3.6 L (13.9%)Rejected-Finance | L5 | Rejected-Finance Rejected |
Tender Value
₹33 L
EMD Value
₹66,000
Closing Date
19 Sept 2022, 6:00 pmClosed
GE Faridkot
GE Faridkot Military Station
Spl repair/replacement of BER electrical items and Provn of high mast security light at MT park of FD Regt at Faridkot Mil Stn
2022_MES_542626_2
GE FRD-38/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE Faridkot
Class D Category b i
8 documents required · 8 mandatory
₹500
GE Faridkot
₹66,000
Yes
26 Sept 2022
26 Aug 2022
21 Sept 2022
26 Aug 2022
19 Sept 2022
5 Sept 2022
Amount
Supply & fixing Energy efficient Ceiling fan complete with blades, down rods, electronic type regulator & accessories, 230 V,1200mm sweep, minimum air delivery 245 CFM with service value 6.00 BEE, 5 star rated with brushless direct current motor (BLDC) complete all as specified and directed
S&F ceiling fastner (D Hook) for ceiling fans complete all as specified and directed .
M&L for Writing letters or figures (Block, Roman, Italic or Indian) n.exc 30cm high with synthetic enamel paint complete all as specified and directed
Taking down carefully existing aluminium/copper point wiring for light, fan, socket or power bell complete with fittings such as Switches, sockets, ceiling roses, holders, call bells & making good the disturbed surfaces of walls, matching the colour with existing surface complete all as specified and directed. Note : Rate for making good shall be deemed to be included in above item rate.
Point wiring complete with 1.5 sqmm single core PVC insulated unsheathed cable(ISI marked) 1100 volts grade FRLS with multistranded copper conductor, drawn through concealed / surface in wall / roof/ceiling surface and its accessories on the surface etc drawn into existing PVC rigid concealed conduit of suitable size , MS junction boxes, 2mm thick galvanised steel pressed sunken terminal boxes of suitable sizes for mounting of switches, sockets, fan regulator etc, covered with 2.8mm thick plastic laminate Hylem / Anchor top cover sheet of required colour, fixed with brass screws and cup washers, painting terminal boxes inside and outside with one coat of red oxide primer including continuous earth wire of size 1.5 Sqmm PVC stranded copper conductor unsheathed, insulated, stranded (Green colour) connected to common earth point dolly for for one light point/fan point/exhaust fan, 230 volts controlled by one switch complete all as specified and directed .
All as per Srl item No. 05 here-in-before for Switch socket combination (multi purpose) 6 Pin 15 Amps 230 volts point to be controlled by one switch and wiring with 2.5Sqmm FRLS PVC unsheathed copper conductor and FRLS cable 2.5 Sqmm PVC insulated earth wire on independent board.complete all as specified and directed
S&F switch piano, flush type, single pole, one way, 5 /6 Amp,230 V,AC supply complete all as specified and directed .
S & F exhaust fan ,steel body, AC single phase, 4 blades with louver shutter suitable for operation on 220/230 volts of 300mm sweep and all fixing arrangements like wall hole, material etc complete all as specified & directed
Supplying and fixing and commissioning of electric water heater (Gyser) storage type ABS body of capacity 25 ltrs, BEE appreoved 5 star rating, 230V,single Phase, AC supply inner tank made out of heavy duty stainless steel sheet (Designed with single weld line, factory tested with hydraulic pressure as per latest IS code) with glass lined quoting complete with all accessories such as safety valve thermostate NRV, connection piece PVC connection for hot and cold water 3 core PVC insulated PVC sheated copper conductor flexible cable including 15 Amp plug suitable for existing socket and fixing material, 04 Nos nut bolt grouting in wall in PCC(1:2:4) using 12.5mm graded stone aggregate for hanging the geyser and making good the disturbed surface complete all as specified and directed by Eng-in-Charge.
S&F in replacement Sheet Metal Enclosures Plug metal clad SP&N with a two pin and earth plug and socket with MCB SP 20 Amps suitable for working on 230 volts AC complete all as specified & directed.
S&F in replacement MCB SP 5 to 32 amps 240V 'B' curve with breaking capacity 10 KA in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
S&F in replacement bib tap, cast copper alloy with crutch or butter fly handle, screwed down, screwed for 15mm bore pipe & fixed complete all as specified and directed
S&F in replacement Stop valve, cast copper alloy,fancy type, chromium plated,screwed down for high pressure with crutch or butter fly handle, screwed both ends for iron pipe of 15mm bore complete all as specified and directed .
S&F in replacement three core copper flexible wire of size 23/0.0076 complete all as specified and directed. Note:- 0.80 metre wire will be considered as one job
S&F in replacement GI tubing,15mm bore, medium grade with all fittings , fixed to wall/ceiling and laid in trenches/under road complete all as specified and directed .
Supply, install, commissioning of 16 metre high 20 sided polygon highmast lighting system fabricated out of BS-EN 10025 or equivalent 355 Mpa material in two sections, hot dip galvanised (single dip) internally & externally having uniform coating thickness of 85/ 65 micron for bottom & top section respectively as per BS 729 and with one longitudinal weld and having no circumferential weld suitable for wind velocity of 180 Km/hr as per IS -875 (Part-3) duly provided with accessories like head frame, steel wire rope 6mm dia (7/19 construction with central core SS) trailing cable double drum winch, galvanised lantern carriage arrangement suitable for 09 luminaires symmetrically and end finial. The mast shall have an integral power tool installed inside the base compartment for its operation as per manufacturers design/ details complete all as specified and directed . Make : CG Cat No. HM-1116 A or eqivelant in Philips/Bajaj/Wipro of 16 M height suitable for design condition specified above. Highmast light includes the following : -(i) Supply, and fixing of foundation bolts manufactured from special steel alongwith nuts, washers, anchor plates and templates etc as required as manufacturers recommendations suitable for design life not less than 25 years.(ii) Erection and commissioning of high mast with the help of suitable equipments and wiring of luminaries with all copper conductor, cable of suitable size & providing flexible steel conduit pipe ¾” for protection of cable. (iii) Drawing, design and casting of suitable shallow foundation with RCC M-25 mix concrete for high mast considering the safe bearing capacity of soil as 10 tonne/ Sqm at 2.50 metre depth duly approved by GE - 01 Job each. (iv) Casting of suitable foundation with RCC M-25 mix concrete for panel as per manufacturers recommendations. (v) Supply and fix LED flood light fitting luminarie 160 W with LED lamp, secondary optics made in pressure die cast housing and heat sink in aluminium extursion type with IP65 protection class - 09 Nos each Make Bajaj or equivelant in Crompton, CG/Philips/Halonex . (vi) Supply and fix integral aviation obstruction light comprising of aluminium housing with polycarbonite enclosures - LED type - 02 Nos Each Make : Bajaj or equivelant in Crompton Greaves, Philips & GE (vii) Supply and installaton of control panel (KIOSK) (out door, double door) with auto control timer switch unit with digitial time switch of capacity 63 Amps tripple pole & neutral (TP&N) MCB incomer housing suitable for circuit for operation of mast including suitable control circuit for power tool motor complete as per manufacturer recommendations- 01 Jobs Each. (viii) All necessary Excxavation and earthwork in any type of soil including returning, filling and removal of surplus soil to distance not exceeding 50 metre completed all as specified and directed by Engineer-in-Charge. (ix) Contractor shall submit Manufacturer defect guarantee certificate for a period not less than 05 years.
Excavation in trenches in soft/loose soil, n. exc 1.5 m wide and n. exc 1.5 m in depth for foundation, laying of underground cable etc or n. exc 10 Sqm on plan and n. exc 1.5 m in depth for foundations of poles, struts, stays etc.& getting out including trimming the sides and forming bottom surfaces to required level complete all as specified and directed.
Returning, filling in including spreading, leveling, watering & and well ramming in layers n.exc 25 cm in soft/loose soil complete all as specified and directed .
Removing excavated material to a distance n.exc 50 m & depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed .
M&L for sand cushioning with a layer of dry river sand, 80mm thick before laying of cable and 150mm thick (punned down to 100mm thick) after laying of cables, in trenches/ducts, complete all as specified and directed. Note : Punned down thickness (overall 18cm), shall be considered for measurement and payment.
Material & labour, for cutting existing road for taking out/laying of underground cable through GI pipe of dia 40mm to 100mm including necessary earth work and making good to match with the existing surface with PCC 1:2:4 type B-1 using 20mm graded stone aggregates complete all as specified and directed
Supplying and laying, factory made unreinforced precast concrete cable cover LV type-1, flat, of size 250x150x40mm, laid flat and dry in trenches over the cable for protection, length perpendicular to the direction of cable adjacent to each other, complete all as specified and directed.
Supply and laying / fixing , GI pipe, light grade, 40mm dia bore for cable protection fixed to pole/wall with MS clamps, nuts, bolts etc or laid under floor/road/pavement, including taking out old unserviceable pipe complete all as specified and directed. Note : (i) Excavation and earth work shall be measured and paid separately.
Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated, armoured, heavy duty, electric power cable, cross sectional area 25 Sqmm, 4 core, aluminum conductor, 1100 volts grade under ground cable including both side connection with lugs/thimbles of suitable size etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, complete all as specified and as directed. Note: (i) Returning filling, earth work, sand cushioning and cable cover for protection of cable shall be measured and paid separately.
Supply, fixing & fabricated distribution box of size 450 mm x 450mmx 300mm in sheet metal enclosure 3.0 mm thick, outdoor type ,Powder coated CRCA sheet metal enclosure angle mounted angle Iron ( 50mmx50mmx5 mm) frame, hight 0.45 RM suitable for MCCB 40 Amps, 16 KA - 1 No, complete all as specified and directed.
M&L for Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.00mm thick, buried directly in ground vertically (depth of pit not less than 2.25m below normal ground level), with top edge of the plate not less than 1.5m below normal ground level, earth plate surrounded by 15cm thick and packed alternate layers of charcoal dust and common salt, connected with and including GI strip 32x6mm by means of bolts, nuts, check nuts and washers of galvanized iron or thimbles and other end of the earth wire connected to electrical equipment/GOD/LA and protected by galvanized iron pipe light grade 40mm dia bore including watering pipe 20mm dia bore GI medium grade (ISI marked) with funnel and wire mesh, including all necessary excavation and earth work, PCC chamber in plain cement concrete (1:3:6) type C-1 and pit cover of precast RCC with MS frame etc and all as shown in electrical plate No 3 of MES Schedule Part-I (2009), complete all as specified and directed. Note(s):- (i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with TMT bar 8mm dia both ways @100c/c. (ii) PCC chamber shall be constructed 500 mm away from the edge of earth pit. (iii) Rate shall include earth lead and protection pipe of length 7.5m, excess beyond 7.5m length required at site shall be measured and paid separately. (iv) Earth resistance should be less than 3Ohm. In case the test results are not found below 3Ohm, complete earthing will be redone without any extra cost to Govt. (v) Quoted lump sum / rate shall be inclusive of above all provisions. Note :- A Sum of Rs. 68,632.00 will be deducted on account of credit for dismantling/demolished/taking down material. Please refer detail on srl page No 19(Schedule of credit) of Tender Documents.
Vinod Kumar Bajaj
M/S BSS AND SONS
NEW AMRITSAR CONSTRUCTION COMPANY
M/s Manoj Construction Co.
Singla Electricals
HARSH CONSTRUCTION CO.
OBEROI CONSTRUCTION CORPORATION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .