Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance 5 32 PANNA LAL ROAD INDIAN PRESS CROSSING ALLAHABAD UTTAR PRADESH 211011 | PRAYAGRAJ | UTTAR PRADESH | 211011 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance 249 LIG PREETAM NAGAR ALLAHABAD UTTAR PRADESH PIN 211011 | ALLAHABAD | ALLAHABAD | UTTAR PRADESH | 211011 | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
Refer Docs
Closing Date
7 Aug 2020, 3:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Director
MNNIT Allahabad, Prayagraj-211004
Extension and repairing of electrical wiring in the faculty quarters no.A-12, C-06, C-39 and H-51.
2020_MNNIT_572667_1
02/ESWM/2020-21/04
Limited
Electrical Works
Item Rate
180 days
Residential Campus
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Director
Exempted
10 Aug 2020
23 Jul 2020
10 Aug 2020
23 Jul 2020
7 Aug 2020
23 Jul 2020
120 days
Extension and repairing of electrical wiring in the faculty quarters no. A-12, C-06, C-39 and H-51.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Wire Make- KEI,R.R Kable, Kalinga Premium. HPL, Havells.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. Make- L&T, Havells, KEI, Rallision, Kalinga, R.R Kable. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. Make- L&T, Havells, KEI, Rallision, Kalinga, R.R Kable. 2 X 4.0 sq. mm + 1 X 4.0 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. Make- L&T, Havells, KEI, Rallision, Kalinga, R.R Kable. 4 X 10.0 sq. mm + 2 X 6.0 sq. mm earth wire
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. Make- Anchor Roma, Havells crabtree, Philips, C&S.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. Make- Anchor Roma, Havells crabtree,C&S.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. Make- Anchor Roma, Havells crabtree, Philips, C&S, L&T Note- 2 nos. switch and 2nos. socket on each boards.
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. Make-L&T, Simens, Legrand, HPL, Havells, C&S
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supply and fixing of two number 8 SWG Copper wire in 15 dia G.I. pipe for earthing, laid in ground or in wall duly concealed including the cost of cement, sand, labour, T&P other material required for proper completion of the work as directed at site with 2 Nos. 8 SWG Copper wire. complete in all respect.
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) Make- L&T, Havells, Legrand, HPL, C&S, Schnider,Siemens. 4 WAY (4+12 ), Double Door
Supply & fixing of 63 A. 4 pole MCB (10KA) C Curve. CAT A . Make- Havells, Legrand, HPL, C&S, ABB, L&T
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Make- L&T, Havells, Legrand, HPL, C&S Single pole
Supply and fixing of following plain or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tape and making connection.Complete in all respect as per Engineer-Incharge. 10 sq mm
Dismantaling of old installation with proper finishing of dismantaled portion including cost of wireman, labour, T&P for proper finishing of work. Complete in all respect.
Sai Enterprises
Allied Refrigeration and Electrical Works
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .