Executive Engineer
Office of the Executive Engineer Mechanical and Hospital Division Anantnag
Repairs of Oxygen Flow Meter, Oxygen Outlet Point and Vacuum Jars at District Hospital Pulwama.
2025_PWDJK_295042_1
MHDA/TS/E-TENDER/66 OF 2025-26
Open Tender
Repair and Maintenance Works
Item Rate
10 days
DH Pulwama
Refer NIT
5 documents required · 5 mandatory
₹200
Executive Engineer M and H Division Anantnag
₹4,700
29 Nov 2025
13 Nov 2025
26 Nov 2025
13 Nov 2025
25 Nov 2025
13 Nov 2025
Providing, fitting and testing of new BPC oxygen flow meter with humidifier bottles connected to the self sealing valves of oxygen and compatible probe. BPC oxygen flow meter shall be offering the latest technical improvements for a precise measuring of the flow with +/-5% accuracy. The body of the flow meter shall be chrome plated Brass, graduated flow tubes and cover made of polycarbonate. The flow meters shall have adjustable flow by needle valve with micro metrical regulation. The flow meter shall be able to compensate back pressure and shall have a standard flow of 0-15 LPM. The inlet filter of flow meter shall be made of stainless steel wire net and is be connected to the outlet of self sealing valve with humidifier bottles. This includes providing and fitting of necessary copper fittings complete in all respects.
Replacement of damaged Oxygen outlet points by way of supply, installation, testing & commissioning of Oxygen PB type Gas outlets properly cleaned for medical gas service.Each outlet will have less than 3 psi (21KPa) pressure drop through the outlet @ 120 l/min. and 50 psig (345KPa) inlet pressure. For outlets providing positive pressure gas, the outlet will be equipped with a primary and secondary check valve wil be rated for 200psi (1,379 kPa) allowing the primary check valve to be removed for services without isolating the entire zone. The wall outlets will have a gas specific back body with steel mounting plate, which allows outlets to be ganged together with a center line spacing of 5" (127mm). Each back body will be equipped with a 6½" (165mm) length type "K" copper pipe stub which is brazed to the outlet body. The inlet pipe can be swiveled 360 degrees for ease of installation.
Providing,fitting and testing of Vaccum jars of capacity 800 ml of polycarbonate or polypropylene ,wall mountable compatable with standard suction catheter with a graduation unit of measuring vaccum pressure along with the inlet and oulet pipe
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.41 MB
BOQ_954730.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .