Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.7 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹19.2 L+₹40,853 (2.18%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹20.5 L+₹1.7 L (9.09%)Admitted-Finance | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Vaish Electricals L1 | ELECTROCONTROL INDIA L3 | Bajrang Electric Works L2 |
|---|---|---|---|---|---|---|
| 1.00Power capacitors | ||||||
| 1.01 | Supply, installation, testing and commissioning of ultra heavy duty power capacitor, 480Volt, 25KVAR for replacement of existing and defective capacitors including making good of all the necessary connections along with materials and manpower etc as required. | 15 | Set | 8,500 ₹1,27,500 Lowest | 10,000 ₹1,50,000 | 9,200 ₹1,38,000 |
| 2.00 | Supply, installation, testing and commissioning of 3 pole power contractor (3TF50, 110 Amps, Coil Voltage-220-240Volt, 50Hz, AC) along with auxiliary contact block ( 3TF50/Second 1NO + 1NC Left & Second 1NO + 1NC Right/Type-3TY7561-1KA008K) for replacement of existing and defective contractor including making good of all the necessary connections along with materials and manpower etc as required. | 1 | Set | 23,000 ₹23,000 Lowest | 25,000 ₹25,000 | 24,000 ₹24,000 |
| 3.00 | Supply, installation, testing and commissioning of 3 pole, 33KV, 800 or 630 or 400 Amps Off-load Type Manual operated Isolator with earth switch complete set for replacement of existing and defective isolator switch, including dismantling of defective unit, inclusive of all the requisite materials and manpower for successful operation of the said isolator etc. as required. | 1 | Set | 1,75,000 ₹1,75,000 Lowest | 1,88,000 ₹1,88,000 | 1,80,000 ₹1,80,000 |
| 4.00 | Supply, istallation, testing and commissioning of axial flow fan of 8 inch diameter (220X220X60mm), single phase 230Volt AC, 2400 RPM having aluminium housing with plastic impeller, AC frame type, 360CFM, static pressure -22mmH2O, noise level-56dB(A) in the existing 33KV substation MT panel, etc as required. | 15 | Set | 2,000 ₹30,000 Lowest | 2,500 ₹37,500 | 2,100 ₹31,500 |
| 5.00Supply, istallation, testing and commissioning of following spares for Siemens make air circuit breaker, including dismantling of defective spares, fixing of new spares, making good of all the necessary connections along with materials and manpoweretc as required: | ||||||
| 5.01 | a) CIRCUIT BREAKER AUXILIARY CONNECTOR DRAWOUT VERSION | 2 | Each | 8,600 ₹17,200 Lowest | 9,150 ₹18,300 | 8,780 ₹17,560 |
| 5.02 | b) Accessory 3WA/3WL Base part for secondary disconnect terminals | 1 | Each | 16,195 ₹16,195 Lowest | 17,275 ₹17,275 | 16,500 ₹16,500 |
| 5.03 | c) 3WT FRONT FACIA FOR DRAWOUT BREAKERS | 1 | Each | 32,096 ₹32,096 Lowest | 34,235 ₹34,235 | 32,440 ₹32,440 |
| 5.04 | d) CIRCUIT BREAKER SHUTTER FOR GUIDE FRAME, 4POLE F. RATED CURRENT UP TO 1600A | 2 | Each | 11,446 ₹22,892 Lowest | 12,210 ₹24,420 | 11,700 ₹23,400 |
Tender Value
₹17.8 L
EMD Value
₹35,671
Closing Date
24 Dec 2025, 10:00 amClosed
Sr. S.E./E, CSIR-CDRI LUCKNOW
Director CSIR-CDRI Lucknow
Retrofitting, alignment of incoming and outgoing bus bars, repairing of air circuit breakers, outdoor isolator in 33KV switch yard, replacement of defective capacitors etc. of APFC panel installed in 33KV substation at CDRI
2025_CSIR_257731_1
2/24/2025-Engg.
Open Tender
Electrical Works
Item Rate
120 days
CSIR-CDRI LUCKNOW
No
5 documents required · 5 mandatory
₹0
₹35,671
Yes
7 Jan 2026
3 Dec 2025
26 Dec 2025
3 Dec 2025
24 Dec 2025
3 Dec 2025
Amount
Power capacitors
Supply, installation, testing and commissioning of ultra heavy duty power capacitor, 480Volt, 25KVAR for replacement of existing and defective capacitors including making good of all the necessary connections along with materials and manpower etc as required.
Supply, installation, testing and commissioning of 3 pole power contractor (3TF50, 110 Amps, Coil Voltage-220-240Volt, 50Hz, AC) along with auxiliary contact block ( 3TF50/Second 1NO + 1NC Left & Second 1NO + 1NC Right/Type-3TY7561-1KA008K) for replacement of existing and defective contractor including making good of all the necessary connections along with materials and manpower etc as required.
Supply, installation, testing and commissioning of 3 pole, 33KV, 800 or 630 or 400 Amps Off-load Type Manual operated Isolator with earth switch complete set for replacement of existing and defective isolator switch, including dismantling of defective unit, inclusive of all the requisite materials and manpower for successful operation of the said isolator etc. as required.
Supply, istallation, testing and commissioning of axial flow fan of 8 inch diameter (220X220X60mm), single phase 230Volt AC, 2400 RPM having aluminium housing with plastic impeller, AC frame type, 360CFM, static pressure -22mmH2O, noise level-56dB(A) in the existing 33KV substation MT panel, etc as required.
Supply, istallation, testing and commissioning of following spares for Siemens make air circuit breaker, including dismantling of defective spares, fixing of new spares, making good of all the necessary connections along with materials and manpoweretc as required:
a) CIRCUIT BREAKER AUXILIARY CONNECTOR DRAWOUT VERSION
b) Accessory 3WA/3WL Base part for secondary disconnect terminals
c) 3WT FRONT FACIA FOR DRAWOUT BREAKERS
d) CIRCUIT BREAKER SHUTTER FOR GUIDE FRAME, 4POLE F. RATED CURRENT UP TO 1600A
e) 3WT LAMINATION BLOCK, UPTO 1600A
f) 3WT HORIZONTAL TERM, 1600A
g) 3WT Ruckwand 4 POLE, Size I <=1600A
h) 3WL FRONT FACIA
i) Mounting set Cover Bg.II left side 4pole
j) Mounting set Cover BG II 3pole right or left side/4pole right side
k) 3WA Door sealing frame
l) 3WL COIL MOUNTING PLATE FOR SIZE II & SIZE III
m) ACCESSORIES CIRCUITBREAKER 3WL KIT FOR CONV. FIXEDMOUNTED TO WITHDRAWABLE SIZE 2, 4POLE (AUX.CURRENT SHIFT MODULES AND GUIDE FRAMES ARE TO BE ORDERED INDIVIDUALLY)
n) Accessory 3WA/3WL Charging Motor (M) 208-240 V AC /220-250 V DC
o) Accessory 3WA/3WL Closing coil (CC) / Shunt trip (ST), 100% OP208-240 V AC / 220-250 VDC for continuous duty
p) Accessory 3WA/3WL Undervoltage release (UVR) Instantaneous (0,08 s) and short-delay (0,2s), 380-415 V AC
Retrofitting of 50mmx6mm aluminium basbar connected with air circuit breakers incoming and its outgoing including all the consumable materials like insulation of all requisite colours, post insulators along with bolt etc as required:
a) 1600 Amps, 4 Pole air circuit breaker
Bajrang Electric Works (BID ID -945911)
ELECTROCONTROL INDIA (BID ID -947808)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Document
0.99 MB
Tender Documents
Tender Documents • 0.86 MB
BOQ
BOQ • 0.37 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .